1 R&S TSMA Release Notes Firmware Version Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, Munich, Germany Phone: Fax: Internet: Subject to change R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. The firmware of the instrument makes use of several valuable open source software packages. For information, see the "Open Source Acknowledgement" document, which is available for download from the R&S TSMA product page at The following abbreviations are used throughout this document R&S TSMA is abbreviated as R&S TSMA Release Notes PAD-T-M: /02.01/CI/1/EN

2 Information on the Current Version and History Contents 1 Information on the Current Version and History Version Version Version Version Version Version Version Version Version Version Version Version Firmware Update Preparing Installation Choosing the Way of Installation Preparation for Local Installation Preparation for Remote Installation Preparation for TSMA Web-GUI based Installation Setting Mode of Operation Performing Firmware Update Local Installation Remote Installation Using the R&S TSMA Web-GUI Installation of Remote ViCom Server Preparation ViCom Server Installation Software Installation R&S NESTOR Software Preparation NESTOR Installation QualiPoc Software Preparation...24 Release Notes

3 Information on the Current Version and History QualiPoc Installation R&S ROMES Software Preparation ROMES Installation Customer Support Release Notes

4 Information on the Current Version and History 1 Information on the Current Version and History 1.1 Version Improvements Version Improvements New version of TsmeTools (TsmeTools v ) Solved Problems Version Solved Problems Accidental power cycle in Stand-by Mode Mode selection via Web-GUI does not work, when the folder C:\Temp was deleted 1.2 Version Improvements Version Improvements Restart via web-gui triggers power cycle of scanner sub. component New version of TsmeTools (TsmeTools v ) Watchdog time out triggers power cycle Solved Problems Version Solved Problems TSMA6-BP STATE LEDs not operated in stand-by mode 1.3 Version Improvements Version Improvements NET is part of the firmware setup Successful ROMES license file installation is confirmed in the web-gui Release Notes

5 Information on the Current Version and History Solved Problems Version Solved Problems Hang-up in battery communication when battery pack is connected Power on via power button sometimes not possible 1.4 Version Firmware package contents Version Contents Bluetooth configuration in Web-GUI in Win Additional mode Smart Monitor supported in Web-GUI Auto-Power On mode with TSMA-BP power supply Charge indication with TSMA-BP in STB mode ROMES Probe Mode removed Backup / Recovery Win Updated online help Improvements Version Improvements Auto-Refresh off all dynamic Web-GUI contents Remote Shutdown with power on delay 30 s Solved Problems Version Solved Problems NESTOR mode not loaded after restart when activated in Web-GUI 1.5 Version Firmware package contents Version Contents Reboot button in web-gui TSME service adaptations for Win Support Challenger TSME Tools v ViCom Server v15.80 Improvements Version Improvements Release Notes

6 Information on the Current Version and History Only installed SW packages are offered in mode selection of the web-gui Solved Problems Version Solved Problems Device hang-ups (power button and battery pack communication) ViCom Server does not start after power up Unsynchronized launch of QualiPoc and ROMES Probe processes at device startup Bluetooth adapter disabled after firmware update ViCom SampleApp not selectable in web-gui for download Failed user backups due to small partition size Wrong device identity with connected TSME in a MIMO setup Known Issues Version Known-Issues 1.6 Version Firmware package contents Version Contents Support for QualiPoc v16.2 (Windows service) Improvements Version Improvements Online Help updated Reboot requests are indicated in web-gui status text. Solved Problems Version Solved Problems NESTOR mode service is not started after restart MeasurementConfigVicom.xml not evaluated Web-GUI password protection does not work Firmware not downward compatible with TSMA Access-DLL Mode changes from ROMES Probe mode don t end ROMES satellite application Watchdog initiated restarts when not initialized. Release Notes

7 Information on the Current Version and History Known Issues Version Known-Issues Bluetooth adapter disabled after firmware update / initial activation via web-gui requires a restart ViCom Sample App setup for Android devices is not selectable in File Transfer/Update menu of the web-gui. This is only valid for the TSMA ViCom setup v Will be solved in a higher version of the TSMA rvicom setup (TSMA-rViCom-Setup-<Version>.exe) Version Firmware package contents Version Contents Support for various ROMES modes in web-gui Configurable start-up delay in web-gui Auto power off feature in case of DC IN absence configuration via web-gui User image creation from web-gui / requires image version 1.03 / Tool chain to create & deploy a master image Windows tray icon for battery charge TsmeTools update to v System restart button via web-gui Remote shut-down support Version info table of all installed SW applications / web-gui WLAN permanent off configurable via web-gui Improvements Version Improvements Auto-refresh of dynamic web-gui contents (battery power, temperatures) Charging indication off battery pack via LEDs Battery charge indication of battery pack when TSMA powered off / STB WLAN AP is now indicated via the STATE LED Power on hysteresis in case off low power battery state File size limitation for web-gui based downloads increased to 4 GB Solved Problems Version Solved Problems Firmware installation blockings when TsmeTools were updated manually Hang-ups when changing the operation mode in web-gui Changing band options via Web-GUI Installation / query of NESTOR licenses via Web-GUI Known Issues Version Known-Issues Release Notes

8 Information on the Current Version and History 1.8 Version Firmware package contents Version Contents Update TsmeTools v Updated Online Help v Default keyboard layout English US Indication of failed scanner link via STATE LED Indication of Scanner Only Mode via STATE LED Progress of software installation is indicated by blinking STATE LED Improvements Version Improvements Auto-Shutdown with low battery power Status feedback in Web-GUI while firmware / software installation Minor changes in Web-GUI usability Selected NESTOR setup is displayed in the Web-GUI Solved Problems Version Solved Problems Instable / missing WLAN access point after power up Diversity start in PC mode when executing setup Known Issues Version Known-Issues Web-GUI does not support installation and query of NESTOR licenses 1.9 Version Firmware package contents Version Contents Support of NESTOR Measurement Probe Installation of NESTOR option keys via Web-GUI added Update TsmeTools v Improvements Version Improvements LAN port setting via Web-GUI Bluetooth binding via Web-GUI Release Notes

9 Information on the Current Version and History SCPI Support (Date, Time) Reliability of WLAN access point if enabled via Web-GUI Solved Problems Version Solved Problems Incomplete firmware setups due to hardware watchdog Known Issues Version Known-Issues Diversity setup alters default WLAN key / manual correction necessary NESTOR setup 1.4 requires manual setting of Windows firewall permissions Sporadic absence of WLAN access point after power up 1.10 Version 1.07 Firmware package contents Version Contents 1.07 Configurable Power On Mode ( Auto Power On / Remember Last State) 1.07 Default paths for measurement applications (NESTOR, rvicom Server, Diversity) are configured with a MeasurementConfig.xml file 1.07 Configuration of TSMA as WLAN client via Web-GUI 1.07 Configuration of NESTOR auto-start mode with selectable workspace via Web-GUI Improvements Version Improvements 1.07 Matching of LAN/WLAN settings in Web-GUI and in Windows OS 1.07 WLAN Access Point: default on 1.07 Web-GUI now reports absolute state of charge Known Issues Version Known-Issues 1.07 NESTOR slave mode configuration in Web-GUI not supported yet 1.07 Applying fixed IP address und subnet mask of LAN port via Web-GUI initializes of LAN Gateway and DNS server address to Version 1.05 Firmware package contents Version Contents 1.05 No changes to previous version Release Notes

10 Information on the Current Version and History Improvements Version Improvements 1.05 LAN/WLAN configuration in the Web-GUI improved Known Issues Version Known-Issues 1.05 NESTOR mode selection / configuration via Web-GUI not supported 1.05 Web interface displays wrong software version 1.05 TSMA configuration as WLAN client via Web-GUI not supported 1.05 DHCP setting in Web-GUI does not set DNS Server to "obtain DNS server automatically 1.05 Fix IP LAN configuration in Web-GUI sets Gateway and DNS server to Web interface displays ASOC for batteries in overview page 1.12 Version 1.04 Firmware package contents Version Contents 1.04 TSMA Firmware 1.04 ViCom Server v Microcontroller v Installation Assistant Service v Compass Platform v Compass Platform LXI v Visa Runtime v MDNS Service v TSME Tools v New Functionality Version Functions 1.04 Initial release Known Issues Version Known-Issues 1.04 LAN/WLAN configuration via Web-GUI might sometimes work not properly 1.04 NESTOR mode configuration in Web-GUI not yet supported 1.04 IP address settings in Web-GUI sometimes not applied in Windows Release Notes

11 Firmware Update 2 Firmware Update Firmware update packages for the R&S TSMA could be downloaded from the Rohde & Schwarz web page The firmware setup file is named TSMA-Setup-<Version>.exe. Remote ViCom Server Update Remote ViCom Server (rvicom server) is a supplementary firmware package. This package is only necessary when the R&S TSMA is operated in rvicom Server mode. After firmware installation, please proceed with rvicom server installation, see Installation of Remote ViCom Server. For Firmware Version 1.07 and Lower The local installation, see chapter Local Installation, is the recommended way to upgrade devices with firmware 1.07 and lower. 2.1 Preparing Installation Choosing the Way of Installation There are several ways how to upgrade R&S TSMA firmware / software. Select the preferred way Local execution of the setup file on the R&S TSMA Requires to connect mouse, keyboard and monitor to the R&S TSMA und to execute the setup file on the device, see Chapter 2.1.2, Preparation for Local Installation Remote execution of the setup file from a distant PC The R&S TSMA need to be connected via LAN / WLAN to the remote PC. The setup is executed and controlled from the remote PC (Windows 7 / 10). There is no need to interface the R&S TSMA, see Chapter 2.1.3, Preparation for Remote Installation Web-GUI based upgrade from a handheld device using an USB stick Requires the setup file to be available on a USB memory stick. The memory stick need to be connected to an USB socket of the R&S TSMA. The web-gui could be called locally on the R&S TSMA or from a remote device (Windows PC) or handheld device (Android), see Chapter 2.1.4, Preparation for TSMA Web-GUI based Installation. Release Notes

12 Firmware Update Preparation for Local Installation 1. Connect mouse, keyboard to the USB ports and a monitor to the mini display port. Display Port Adapter DVI2HDMI: R&S TSPC-DPDH (R&S No ) 2. Switch on the R&S TSMA via power button. 3. Copy the setup file: a) For firmware installation: Copy the firmware setup file TSMA-Setup- <Version>.exe into a temporary directory on the local disk of the R&S TSMA. b) For rvicom server / software installation: Copy the corresponding setup file into a temporary directory on the local disk of the R&S TSMA. 4. Proceed with section Setting Mode of Operation Preparation for Remote Installation 1. Copy the setup file: a) For firmware installation: Copy the firmware setup file TSMA-Setup- <Version>.exe into a temporary directory on the remote PC. b) For rvicom / software installation: Copy the corresponding setup into a temporary directory on the remote PC. 2. Establish a LAN respectively WLAN connection between the remote PC and the R&S TSMA, see following section Using LAN Connection 1. Connect the LAN port (R&S TSMA) with the host PC LAN port. The default LAN setting of the R&S TSMA is DHCP client. Ask your network administrator for details on how to configure the remote PC. 2. Switch on the R&S TSMA via power button. 3. Proceed with section Setting Mode of Operation Using WLAN Connection 1. Switch on the R&S TSMA via power button. 2. On the remote PC search for the TSMA WLAN and connect to the network. The necessary access parameters can be found on a label at the bottom of the device. WLAN SSID: TSMA-<xxxxxx> xxxxxx: individual serial number WLAN key: instrument Per default the WLAN access point is enabled. See in the Release Notes

13 Firmware Update R&S TSMA User Manual how the enable the WLAN access point when disabled. 3. Proceed with section Setting Mode of Operation Preparation for TSMA Web-GUI based Installation 1. Switch on the R&S TSMA via power button. 2. Copy the setup file onto a USB memory stick a) For firmware installation: Copy the firmware setup file TSMA-Setup- <Version>.exe into the root directory of the stick. b) For rvicom / software installation: Copy the corresponding setup file into the root directory of the stick. 3. Proceed with section Setting Mode of Operation Setting Mode of Operation 1. The R&S TSMA Web-GUI has to be loaded to check the mode of operation a) Remote installation from a WLAN connected device Start the web browser and enter the following URL: b) Remote installation from a LAN connected device Enter the URL into the browser. TSMA-xxxxxx = R&S TSMA host name. This information can be found on a label at the bottom of the device. c) Local installation Open the Internet Explorer. The Web-GUI should be loaded automatically. If not, enter the URL into the browser. 2. The mode of operation is displayed in the overview page. If the mode is already PC Mode you can proceed with step If a different mode is activated, go to the System page and select PC Mode. Press the Submit button to activate this setting. You are asked if you want to change to mode. Acknowledge with OK. The R&S TSMA will reboot. Release Notes

14 Firmware Update A status text is displayed at the bottom of the Web-GUI. The reboot is finished when No error is displayed again. Double check that PC Mode is now activated. 4. The R&S TSMA is ready for firmware update / software installation. Proceed with 2.2, Performing Firmware Update respectively 2.3.2, ViCom Server Installation or 3, Software Installation. 2.2 Performing Firmware Update Local Installation 1. Consider the instruction in the chapter 2.1.2, Preparation for Local Installation. 2. Open the Windows Explorer and execute the setup file TSMA-Setup-<Version>.exe. 3. The R&S Software Distributor window comes up. Select "Local Installation" and press Next. 4. The package dialog lists all the available packages in the setup. Normally, this dialog can be skipped without any changes. Automatic Reboot should be selected. Release Notes

15 Firmware Update 5. Press Install to start setup. The STATE LED starts blinking blue. Important Note Do not switch off or unplug from power while running firmware update! Several reboot cycles may be executed automatically while running the update. 6. Setup is finished when the R&S TSMA comes up after a reboot. The R&S distributor dialog is closed automatically. The STATE LED changes into constant green or amber. 7. Reload the R&S TSMA Web-GUI and double check the displayed firmware version in the Overview menu. The correct version number need to be indicated. The R&S TSMA is ready for operation Remote Installation 1. Consider the instruction in chapter 2.1.3, Preparation for Remote Installation. 2. Execute the firmware setup file on the connected remote PC. The R&S Software Distributor dialog box is coming up. Release Notes

16 Firmware Update 3. Select "Remote Installation" and click "Next >". 4. The package dialog lists all the available packages to install. All packages, which you need to install are already pre-selected. 5. Click Next >. 6. After a while any detected R&S TSMA in the network is listed in the Device List dialog. Tick the device(s) to update. If the column serial number is not filled move the mouse pointer over the listed items to get related device information. 7. Click "Install". Do not switch off or remove power from the R&S TSMA while executing this update! 8. The state of the installation process is displayed in the Status column. The process is finished when the status indicates Ready. 9. Press Exit. 10. Reload the R&S TSMA Web-GUI and verify the installed firmware version in the Overview The R&S TSMA is ready for operation. Release Notes

17 Firmware Update Using the R&S TSMA Web-GUI 1. Consider the instructions in chapter 2.1.4, Preparation for TSMA Web-GUI based Installation. 2. In the R&S TSMA Web-GUI navigate to the File Transfer / Update menu. Open the Select Firmware Setup File select box. 3. Select the appropriate firmware setup file TSMA-Setup-<Version>.exe and press the Execute Setup next to the select box. 4. A confirmation dialog box appears. Confirm with OK to start the update. 5. The firmware installation starts. The Web-GUI displays Installation in progress. The STATE LED is blinking blue for the whole update process. During firmware upgrade the device may run several reboot cycles. Release Notes

18 Firmware Update Do not switch off or remove power from the R&S TSMA while executing this update! 6. At the end of the installation the status text in the R&S TSMA Web-GUI changes to Installation finished system is rebooting. 7. After the reboot the R&S TSMA Web-GUI is refreshed automatically. The upgrade is finished when the status text changes to No error and the STATE LED changes into constant green or amber. 8. The Overview page in the Web-GUI need to display the installed firmware version. Release Notes

19 Firmware Update The R&S TSMA is ready for operation. 2.3 Installation of Remote ViCom Server The Remote ViCom Server package is supplementary for the R&S TSMA. This package is pre-installed on any shipped R&S TSMA. An upgrade of the Remote ViCom package is only necessary when operating the R&S TSMA in rvicom Server mode. This installation could be neglected when running the R&S TSMA in any other mode of operation (NESTOR, ROMES, QualiPoc). The installed version on the R&S TSMA need to match with the applied version of the rvicom client API on the remote Android device. So be careful to update. In cases of a client / server version mismatch there are the following possibilities: a) Downgrade the rvicom server version on the R&S TSMA to match with the applied rvicom client version on the Android device. b) Upgrade the rvicom client version on the connected tablet / smartphone to comply with the installed rvicom server version on the R&S TSMA Preparation 1. Download the firmware setup file TSMA-rViCom-Setup-<Version>.exe from the product support database 2. Choose the way of installation and follow the instructions how to prepare, see Chapter 2.1.1, Choosing the Way of Installation. Release Notes

20 Firmware Update ViCom Server Installation ViCom Server Local Installation 1. Open the Windows Explorer and execute the setup file TSMA-rViCom-Setup-<Version>.exe. 2. The R&S Software Distributor window comes up. Select "Local Installation" and press Next. 3. All subsequent steps are similar to local firmware installation, see Chapter 2.2.1, Local Installation step 4. Do not switch off or remove power from the R&S TSMA while executing this update! 4. Setup is finished when the STATE LED changes from blinking blue to constant green or amber (firmware version ) ViCom Server Remote Installation 1. Execute the setup file TSMA-rViCom-Setup-<Version>.exe on the remote PC. 2. The R&S Software Distributor comes up. Select "Remote Installation" and press Next >. Release Notes

21 Firmware Update 3. All subsequent steps are similar to remote firmware installation, see Chapter 2.2.2, Remote Installation step ViCom Server Installation via Web-GUI 1. Select the appropriate firmware setup file TSMA-rViCom-Setup- <Version>.exe and press the Execute Setup next to the select box. 2. All subsequent steps are similar to firmware installation via web-gui, see Chapter 2.2.3, Using the R&S TSMA Web-GUI step 4. Release Notes

22 Software Installation 3 Software Installation Only use the dedicated TSMA setups for software installation. 3.1 R&S NESTOR Software Only execute the dedicated NESTOR setup for TSMA. The setup file is named: TSMA-NESTOR-Setup-<Version>.exe Preparation 1. Download the software setup file TSMA_NESTOR_Setup-<Version>.exe from the Rohde & Schwarz FTP server respectively NESTOR CD-ROM. 2. Choose the way of installation and follow the instructions how to prepare, see Chapter 2.1.1, Choosing the Way of Installation NESTOR Installation NESTOR Local Installation 1. Open the Windows Explorer and execute the NESTOR setup file TSMA_NESTOR_Setup-<Version>.exe. 2. The R&S Software Distributor window comes up. Select "Local Installation" and press Next. Release Notes

23 Software Installation 3. All subsequent steps are similar to local firmware installation, see Chapter 2.2.1, Local Installation step 4. Do not switch off or remove power from the R&S TSMA while executing this update! 4. Setup is finished when the STATE LED changes from blinking blue to constant green or amber (firmware version ) NESTOR Remote Installation 1. Execute the setup file TSMA_NESTOR_Setup-<Version>.exe on the remote PC. 2. The R&S Software Distributor comes up. Select "Remote Installation" and press Next >. 3. All subsequent steps are similar to remote firmware installation, see Chapter 2.2.2, Remote Installation step 4. Release Notes

24 Software Installation Do not switch off or remove power from the R&S TSMA while executing this update! NESTOR Installation via Web-GUI 1. Select the appropriate NESTOR setup file TSMA_NESTOR_Setup- <Version>.exe and press the Execute Setup next to the select box. 2. All subsequent steps are similar to firmware installation via Web-GUI, see Chapter 2.2.3, Using the R&S TSMA Web-GUI step QualiPoc Software Only execute the dedicated QualiPoc setup for TSMA. The setup file is named: DiversityProbe4QP-DeploymentKit-<Version>.exe Preparation 1. Download the QualiPoc setup file DiversityProbe4QP-DeploymentKit- <Version>.exe from the Rohde & Schwarz FTP server respectively QualiPoc CD-ROM. Release Notes

25 Software Installation 2. Choose the way of installation and follow the instructions how to prepare, see Chapter 2.1.1, Choosing the Way of Installation QualiPoc Installation QualiPoc Local Installation 1. Open the Windows Explorer and execute the QualiPoc setup file DiversityProbe4QP-DeploymentKit-<Version>.exe. 2. The R&S Software Distributor window comes up. Select "Local Installation" and press Next. 3. All subsequent steps are similar to local firmware installation, see Chapter 2.2.1, Local Installation step 4. Do not switch off or remove power from the R&S TSMA while executing this update! 4. Setup is finished when the STATE LED changes from blinking blue to constant green or amber (firmware version ) QualiPoc Remote Installation 1. Execute the QualiPoc setup file DiversityProbe4QP-DeploymentKit- <Version>.exe on the remote PC. 2. The R&S Software Distributor comes up. Select "Remote Installation" and press Next >. Release Notes

26 Software Installation 3. All subsequent steps are similar to remote firmware installation, see Chapter 2.2.2, Remote Installation step 4. Do not switch off or remove power from the R&S TSMA while executing this update! QualiPoc Installation via Web-GUI 1. Select the appropriate QualiPoc setup file DiversityProbe4QP- DeploymentKit-<Version>.exe and press the Execute Setup next to the select box. 2. All subsequent steps are similar to firmware installation via Web-GUI, see Chapter 2.2.3, Using the R&S TSMA Web-GUI step 4. Release Notes

27 Software Installation 3.3 R&S ROMES Software Preparation 1. Download the ROMES setup file TSMA_ROMES_Setup-<Version>.exe from the Rohde & Schwarz FTP server respectively ROMES CD-ROM. 2. Choose the way of installation and follow the instructions how to prepare, see Chapter 2.1.1, Choosing the Way of Installation ROMES Installation ROMES Local Installation 1. Open the Windows Explorer and execute the ROMES setup file TSMA_ROMES_Setup-<Version>.exe. 2. The R&S Software Distributor window comes up. Select "Local Installation" and press Next. 3. All subsequent steps are similar to local firmware installation, see Chapter 2.2.1, Local Installation step 4. Do not switch off or remove power from the R&S TSMA while executing this update! 4. Setup is finished when the STATE LED changes from blinking blue to constant green or amber (firmware version ) ROMES Remote Installation Release Notes

28 Software Installation 1. Execute the ROMES setup file TSMA_ROMES_Setup-<Version>.exe on the remote PC. 2. The R&S Software Distributor comes up. Select "Remote Installation" and press Next >. 3. All subsequent steps are similar to remote firmware installation, see Chapter 2.2.2, Remote Installation step 4. Do not switch off or remove power from the R&S TSMA while executing this update! ROMES Installation via Web-GUI 1. Select the appropriate ROMES setup file TSMA_ROMES_Setup- <Version>.exe and press the Execute Setup next to the select box. Release Notes

29 Software Installation 2. All subsequent steps are similar to firmware installation via Web-GUI, see Chapter 2.2.3, Using the R&S TSMA Web-GUI step 4. Release Notes

30 Customer Support 4 Customer Support Technical support where and when you need it For quick, expert help with any Rohde & Schwarz equipment, contact one of our Customer Support Centers. A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation, programming or applications of Rohde & Schwarz equipment. Up-to-date information and upgrades To keep your instrument up-to-date and to be informed about new application notes related to your instrument, please send an to the Customer Support Center stating your instrument and your wish. We will take care that you will get the right information. Europe, Africa, Middle East Phone customersupport@rohde-schwarz.com North America Phone TEST-RSA ( ) customer.support@rsa.rohde-schwarz.com Latin America Phone customersupport.la@rohde-schwarz.com Asia/Pacific Phone customersupport.asia@rohde-schwarz.com China Phone / customersupport.china@rohde-schwarz.com Release Notes

R&S TSMAx Release Notes Firmware Version

R&S TSMAx Release Notes Firmware Version R&S TSMAx Release Notes Firmware Version 03.00.11.00 2019 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S ESU EMI Test Receiver. Release Notes. Firmware Version V5.74 SP1. Only an ESU with Windows 7 Operating System is supported

R&S ESU EMI Test Receiver. Release Notes. Firmware Version V5.74 SP1. Only an ESU with Windows 7 Operating System is supported Release Notes Test and Measurement PAD-T-M: 3574.3288.02/02.00/CI/1/EN R&S ESU EMI Test Receiver Release Notes Firmware Version V5.74 SP1 These Release Notes are for following models of the R&S EMI Test

More information

R&S RTC1002 Digital Oscilloscope Release Notes Firmware Version

R&S RTC1002 Digital Oscilloscope Release Notes Firmware Version R&S RTC1002 Digital Oscilloscope Release Notes Firmware Version 06.100 These Release Notes describe the following models and options of the R&S Digital Oscilloscope: R&S RTC1002 Digital Oscilloscope, order

More information

R&S RTA4000 Digital Oscilloscope Release Notes Firmware Version

R&S RTA4000 Digital Oscilloscope Release Notes Firmware Version Digital Oscilloscope Release Notes Firmware Version 01.100 These Release Notes describe the following models and options of the R&S Digital Oscilloscope: R&S RTA4004, Digital Oscilloscope order no. 1335.7700K04

More information

R&S GNSS Test Automation Release Notes Software Version 1.3.2

R&S GNSS Test Automation Release Notes Software Version 1.3.2 R&S GNSS Test Automation Release Notes Software Version 1.3.2 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S ESR EMI Test Receiver Release Notes Firmware Version V3.36 SP2

R&S ESR EMI Test Receiver Release Notes Firmware Version V3.36 SP2 R&S ESR EMI Test Receiver Release Notes Firmware Version V3.36 SP2 These Release Notes are for following models of the R&S EMI Test Receiver: R&S ESR3, order no. 1316.3003K03 R&S ESR7, order no. 1316.3003K07

More information

R&S VISA Release Notes Software Version 5.8.6

R&S VISA Release Notes Software Version 5.8.6 R&S VISA Release Notes Software Version 5.8.6 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S AVG Pattern Import Release Notes Firmware Version 02.25

R&S AVG Pattern Import Release Notes Firmware Version 02.25 R&S AVG Pattern Import Release Notes Firmware Version 02.25 2010-2015 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

How to Apply MS17-10 to prevent WannaCrypt Attacks

How to Apply MS17-10 to prevent WannaCrypt Attacks How to Apply MS17-10 to prevent WannaCrypt Attacks Document date: 8.8.2017 This document describes the procedure how to apply the Microsoft patches to R&S devices running Windows XP or Win7 operating systems

More information

R&S CMW Bluetooth Release Notes Software Version V3.2.70

R&S CMW Bluetooth Release Notes Software Version V3.2.70 R&S CMW Bluetooth Release Notes Software 2014 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S ESW Test Receiver Release Notes Firmware Version V1.40 SP1

R&S ESW Test Receiver Release Notes Firmware Version V1.40 SP1 R&S ESW Test Receiver Release Notes Firmware Version V1.40 SP1 These Release Notes are for following models of the R&S ESW EMI Test Receiver: R&S ESW8, order no. 1328.4100.08 R&S ESW26, order no. 1328.4100.26

More information

R&S SGT100A RF Source Base Unit Release Notes FW Version

R&S SGT100A RF Source Base Unit Release Notes FW Version R&S SGT100A RF Source Base Unit Release Notes FW Version 3.50.124.71 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: mailto:info@rohde-schwarz.com

More information

How to Apply MS17-10 to prevent WannaCrypt Attacks

How to Apply MS17-10 to prevent WannaCrypt Attacks How to Apply MS17-10 to prevent WannaCrypt Attacks For Video Tester R&S VTC, R&S VTE, R&S VTS and Video Generator R&S DVSG. Document date: 2017-08-03 This document describes the procedure how to apply

More information

R&S RECAL + Release Notes Software Version 4.01

R&S RECAL + Release Notes Software Version 4.01 R&S RECAL + Release Notes Software Version 4.01 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S Spectrum Rider FPH Release Notes Firmware Version V1.50

R&S Spectrum Rider FPH Release Notes Firmware Version V1.50 R&S Spectrum Rider FPH Release Notes Firmware Version V1.50 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S SMB100B Release Notes Firmware Version

R&S SMB100B Release Notes Firmware Version R&S SMB100B Release Notes Firmware Version 4.50.074.45 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S Spectrum Rider FPH Release Notes Firmware Version V1.40

R&S Spectrum Rider FPH Release Notes Firmware Version V1.40 R&S Spectrum Rider FPH Release Notes Firmware Version V1.40 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S SMA100B Release Notes Firmware Version

R&S SMA100B Release Notes Firmware Version R&S SMA100B Release Notes Firmware Version 4.30.040.33 The Release Note is for the following model of the R&S SMA100B RF and Microwave Signal Generator: R&S SMA100B, order no. 1419.8888K02 2018 Rohde &

More information

R&S NRP-Z51/-Z52/-Z55/-Z56/- Z57/-Z58 Thermal Power Sensors Release Notes

R&S NRP-Z51/-Z52/-Z55/-Z56/- Z57/-Z58 Thermal Power Sensors Release Notes R&S NRP-Z51/-Z52/-Z55/-Z56/- Z57/-Z58 Thermal Power Sensors Release Notes 2016 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to change Data without tolerance limits is

More information

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.6

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.6 R&S Pulse Sequencer DFS Software Release Notes Software Version 1.6 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S ELEKTRA Release Notes Software Version V2.10

R&S ELEKTRA Release Notes Software Version V2.10 R&S ELEKTRA Release Notes Software V2.10 ELEMI-E 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version

R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version 3.70.1.0 These Release Notes are for following models of the R&S RTO and R&S RTE: R&S RTO 2002, order no. 1329.7002K02, R&S RTO 2004, order

More information

R&S Broadcast Drive Test Release Notes Software Version 03.13

R&S Broadcast Drive Test Release Notes Software Version 03.13 R&S Broadcast Drive Test Release Notes Software Version 03.13 2015 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.7

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.7 R&S Pulse Sequencer DFS Software Release Notes Software Version 1.7 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

Firmware Release V1.83 SP3

Firmware Release V1.83 SP3 Test and Measurement Division Release Notes for R&S ESL EMI Test Receivers with order number: 1300.5001.xx Release Note Revision: 7 Printed in the Federal Republic of Germany Contents History... 3 General

More information

R&S DSA DOCSIS Signal Analyzer Release Notes Firmware Version 2.2.1

R&S DSA DOCSIS Signal Analyzer Release Notes Firmware Version 2.2.1 R&S DSA DOCSIS Signal Analyzer Release Notes Firmware Version 2.2.1 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S RTB2000 Oscilloscope Release Notes Firmware Version

R&S RTB2000 Oscilloscope Release Notes Firmware Version Oscilloscope Release Notes Firmware Version 02.202 These Release Notes describe the following models and options: R&S RTB2004 Oscilloscope, order no. 1333.1005K04 R&S RTB2002 Oscilloscope, order no. 1333.1005K02

More information

R&S AVBrun Sequencer Software. Release Notes. Firmware Version Release Notes. Broadcasting

R&S AVBrun Sequencer Software. Release Notes. Firmware Version Release Notes. Broadcasting Release Notes Broadcasting PAD-T-M: 3574.3288.02/02.00/CI/1/EN/ R&S AVBrun Sequencer Software Release Notes Firmware Version 01.93 2012-2016 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich,

More information

R&S Power Meter NRP Release Notes Firmware Version

R&S Power Meter NRP Release Notes Firmware Version R&S Power Meter NRP Release Notes Firmware Version 06.03.020 2011 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to change Data without tolerance limits is not binding.

More information

How to deal with the effects of CVE

How to deal with the effects of CVE How to deal with the effects of CVE-2018-0886 Restore Remote Access to R&S instruments V 2.10 Document date: 26.06.2018 This document describes possible ways to access R&S instruments after the security

More information

R&S FSL Spectrum Analyzer Resolving Security Issues When Working in Secure Areas

R&S FSL Spectrum Analyzer Resolving Security Issues When Working in Secure Areas Spectrum Analyzer Resolving Security Issues When Working in Secure Areas Based upon the user s security requirements, this document describes the Rohde&Schwarz options available to address the user s spectrum

More information

R&S NRP-Z27/-Z37 Power Sensor Module Release Notes Firmware Version 04.18a

R&S NRP-Z27/-Z37 Power Sensor Module Release Notes Firmware Version 04.18a R&S NRP-Z27/-Z37 Power Sensor Module Release Notes Firmware Version 04.18a 2010 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to change Data without tolerance limits is

More information

R&S NRPV Virtual Power Meter Release Notes Application Version 3.2

R&S NRPV Virtual Power Meter Release Notes Application Version 3.2 R&S NRPV Virtual Power Meter Release Notes Application Version 3.2 2011-2017 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Subject to change Data without tolerance limits is not binding. R&S is a

More information

TopSec Mobile Secure voice encryption for smartphones and laptops

TopSec Mobile Secure voice encryption for smartphones and laptops Secure Communications Product Brochure 02.00 TopSec Mobile Secure voice encryption for smartphones and laptops TopSec Mobile At a glance The TopSec Mobile is a mobile encryption device for secure worldwide

More information

R&S LXI Class C Support V1.21 (XP)

R&S LXI Class C Support V1.21 (XP) Test and Measurement Division Release Notes for R&S LXI Class C Support V1.21 (XP) R&S FSP Spectrum Analyzers R&S FSU Spectrum Analyzers R&S FSG Signal Analyzers R&S FSQ Signal Analyzers Printed in the

More information

BitLocker White Paper Windows 10

BitLocker White Paper Windows 10 BitLocker White Paper Windows 10 This white paper gives detailed instructions how to enable BitLocker on a measurement device. BitLocker White Paper Windows 10 7.2018 1178.8859.02-01 Table of Contents

More information

LabVIEW driver history for the R&S HMC8012 Driver Documentation

LabVIEW driver history for the R&S HMC8012 Driver Documentation LabVIEW driver history for the R&S HMC8012 Driver Documentation Products: R&S HMC8012 Driver history for LabVIEW Miloslav Macko July 26, 2017 Table of Contents Table of Contents 1 Supported Instruments...

More information

R&S CMW500 CDMA2000 1XRTT and 1xEV-DO Release Notes Software Version

R&S CMW500 CDMA2000 1XRTT and 1xEV-DO Release Notes Software Version R&S CMW500 CDMA2000 1XRTT and 1xEV-DO Release Notes Software Version 3.2.81 2014 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail:

More information

Resolving Security Issues When Working with the R&S ESIB in Secure Areas

Resolving Security Issues When Working with the R&S ESIB in Secure Areas Products: R&S EMI Test Receiver ESIB Resolving Security Issues When Working with the R&S ESIB in Secure Areas Based upon the user s requirements, this document describes the Rohde&Schwarz options available

More information

Release Notes. R&S FSC Spectrum Analyzer

Release Notes. R&S FSC Spectrum Analyzer Release Notes Revision: 02 R&S FSC Spectrum Analyzer Firmware Release 2.20 These Release Notes describe the following models and options of the R&S FSC Spectrum Analyzer: R&S Spectrum Analyzer FSC3, order

More information

R&S DigIConf Software Release Notes Firmware Version Build 170 SP1

R&S DigIConf Software Release Notes Firmware Version Build 170 SP1 R&S DigIConf Software Release Notes Firmware Version 2.20.360.86 Build 170 SP1 2012 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to change Data without tolerance limits

More information

Firmware Version Build 170 SP1

Firmware Version Build 170 SP1 Test and Measurement Release Notes R&S DigIConf Software Release Notes Firmware Version 2.20.360.86 Build 170 SP1 2012 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to

More information

R&S WinIQSIM2 Simulation Software Release Notes Firmware Version

R&S WinIQSIM2 Simulation Software Release Notes Firmware Version R&S WinIQSIM2 Simulation Software Release Notes Firmware Version 4.00.048.23 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail:

More information

R&S QuickStep Test Executive Software Flexibility and excellent performance

R&S QuickStep Test Executive Software Flexibility and excellent performance Product Brochure Version 05.00 R&S QuickStep Test Executive Software Flexibility and excellent performance QuickStep_bro_en_3607-2249-12_v0500.indd 1 21.12.2017 16:45:09 R&S QuickStep Test Executive Software

More information

Wireless Network Video Recorder

Wireless Network Video Recorder LD2R/LD2R500 Wireless Network Video Recorder User Guide Version 1.0 PREFACE Thank you for purchasing the Wireless Network Video Recorder, an IP based device that installed on your network, which can be

More information

R&S Browser in the Box Release Notes

R&S Browser in the Box Release Notes R&S Browser in the Box 2017-07-07 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com Internet:

More information

User Manual PDUTracker

User Manual PDUTracker User Manual PDUTracker Management Software for PDU Table of Contents 1. Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. Install and Uninstall... 1 2.1. System Requirement... 1 2.2. Software

More information

Software Upgrade Online Help

Software Upgrade Online Help Welcome! Digital Lightwave, Inc. is pleased to present the Network Information Computer (NIC) Software Upgrade Online Help To view and select topics, press the folder icons and topics on the left. Have

More information

Print Server. User s Manual. Rev. 01 (April, 2004) Made In Taiwan

Print Server. User s Manual. Rev. 01 (April, 2004) Made In Taiwan Print Server User s Manual Rev. 01 (April, 2004) Made In Taiwan TABLE OF CONTENTS ABOUT THIS GUIDE... 4 INTRODUCTION... 5 PACKAGE CONTENTS... 6 SYSTEM REQUIREMENTS... 6 GENERAL FEATURES... 7 PRODUCT VIEW...

More information

Wireless USB Port Multi-Functional Printer Server. Model # AMPS240W. User s Manual. Ver. 1A

Wireless USB Port Multi-Functional Printer Server. Model # AMPS240W. User s Manual. Ver. 1A Wireless USB 2.0 1-Port Multi-Functional Printer Server Model # AMPS240W User s Manual Ver. 1A Table of Contents 1 Introduction...3 1.1 Package Contents... 3 1.2 System Requirements... 3 2 Multi-Functional

More information

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0

Network USB over IP Server With 1-USB2.0 Port. User Manual V1.0 Network USB over IP Server With 1-USB2.0 Port User Manual V1.0 1 2 TABLE OF CONTENTS COPYRIGHT...4 1. INTRODUCTION...5 PRODUCT OVERVIEW...5 COMPONENTS AND FEATURES...5 HARDWARE INSTALLATION...5 2. THE

More information

USB2.0 LAN DISK User s Manual

USB2.0 LAN DISK User s Manual 1.0 Product overview USB2.0 LAN DISK User s Manual Thank you for purchasing USB2.0 LANDISK the network storage device. Now you can easily add USB2.0 LANDISK into your Network. Before using this device

More information

ADDENDUM. NetworkAIR FM. Contents. Management Card Wizard--1. File Transfers--10

ADDENDUM. NetworkAIR FM. Contents. Management Card Wizard--1. File Transfers--10 Contents Management Card Wizard--1 Introduction....................................... 1 Overview 1 System requirements 2 Configuring Air Conditioner settings 2 Installing the Wizard 2 Online Help 2 Quick

More information

R&S TSMA6 Autonomous Mobile Network Scanner User Manual

R&S TSMA6 Autonomous Mobile Network Scanner User Manual Autonomous Mobile Network Scanner User Manual (a0þç2) 4900805702 User Manual Version 01 This manual describes the following R&S TSMA6 models: R&S TSMA6 (4900.8005.02) 2018 Rohde & Schwarz GmbH & Co. KG

More information

PMS 138 C Moto Black spine width spine width 100% 100%

PMS 138 C Moto Black spine width spine width 100% 100% Series MOTOROLA and the Stylized M Logo are registered in the US Patent & Trademark Office. All other product or service names are the property of their respective owners. 2009 Motorola, Inc. Table of

More information

Release Notes Revision: 01

Release Notes Revision: 01 Release Notes Revision: 01 R&S FSH4/FSH8/FSH13/FSH20 Handheld Spectrum Analyzer Firmware Release 2.81 These Release Notes describe the following models and options of the R&S Handheld Spectrum Analyzer:

More information

R&S SMW200A Vector Signal Generator Instrument Security Procedures

R&S SMW200A Vector Signal Generator Instrument Security Procedures Vector Signal Generator Instrument Security Procedures (;ÚÜÅ2) 1176.7855.02 03 Instrument Security Procedures Contents Contents 1 Overview... 2 2 Instrument Models Covered...2 3 Security Terms and Definitions...

More information

Solution Integration Guide for Multimedia Communication Server 5100/WLAN/Blackberry Enterprise Server

Solution Integration Guide for Multimedia Communication Server 5100/WLAN/Blackberry Enterprise Server Solution Integration Guide for Multimedia Communication Server 5100/WLAN/Blackberry Enterprise Server NN49000-302 Document status: Standard Document version: 0101 Document date: 24 May 2007 All Rights

More information

Installation and Configuration Guide

Installation and Configuration Guide CYBERSECURITY, EVOLVED EdgeWave iprism Web Security Installation and Configuration Guide V8.0 15333 Avenue of Science, Suite 100 San Diego, CA 92128 Give us a call 1-855-881-2004 Send us an email: info@edgewave.com

More information

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver www.longshine.de TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3

More information

Longshine Technologie Europe GmbH

Longshine Technologie Europe GmbH Longshine Technologie Europe GmbH www.longshine.de TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5

More information

WAP6405. User s Guide. Quick Start Guide. 5GHz AC1750 Gigabit Wireless Bridge. Default Login Details. Version 1.00 Edition 1, 06/2016

WAP6405. User s Guide. Quick Start Guide. 5GHz AC1750 Gigabit Wireless Bridge. Default Login Details. Version 1.00 Edition 1, 06/2016 WAP6405 5GHz AC1750 Gigabit Wireless Bridge Version 1.00 Edition 1, 06/2016 Quick Start Guide User s Guide Default Login Details LAN IP Address http://192.168.1.2 (AP Mode) http://192.168.1.5 (Repeater

More information

Software Release Notice TimeScan For Windows 2000/XP/Vista Release 8.7

Software Release Notice TimeScan For Windows 2000/XP/Vista Release 8.7 Software Release Notice TimeScan For Windows 2000/XP/Vista Release 8.7 Introduction Thank you for choosing Symmetricom as your solution provider for carrier-class synchronization network management. This

More information

R&S MSD Modular System Device Flexible antenna switching and rotator control

R&S MSD Modular System Device Flexible antenna switching and rotator control MSD_bro_en_3606-7082-12_v0300.indd 1 Product Brochure 03.00 Radiomonitoring & Radiolocation Modular System Device Flexible antenna switching and rotator control 28.10.2015 12:46:19 Modular System Device

More information

Installation Guide CONTROL MICROSYSTEMS

Installation Guide CONTROL MICROSYSTEMS Installation Guide CONTROL MICROSYSTEMS 48 Steacie Drive n Kanata, Ontario Canada K2K 2A9 Telephone: 613-591-1943 n Facsimile: 613-591-1022 Technical Support: 888-226-6876 (888-2CONTROL) ClearSCADA Getting

More information

R&S SMB100A RF and Microwave Signal Generator Instrument Security Procedures

R&S SMB100A RF and Microwave Signal Generator Instrument Security Procedures RF and Microwave Signal Generator Instrument Security Procedures (;ÚèY2) 1176.9041.02 03 Instrument Security Procedures Contents Contents 1 Overview... 2 2 Instrument Models Covered...2 3 Security Terms

More information

B5021 Ethernet Base Supplemental User Guide

B5021 Ethernet Base Supplemental User Guide B5021 Ethernet Base Supplemental User Guide Overview This is a supplemental user guide for the B5021 Ethernet Base and covers the differences between the B5011 and the B5021. Refer to the B5011 manual

More information

Part No. P May 4, Business Communications Manager. BCM Imaging Tool User Guide

Part No. P May 4, Business Communications Manager. BCM Imaging Tool User Guide Part No. P0609711 01.01 May 4, 2004 Business Communications Manager BCM Imaging Tool User Guide 2 Copyright 2004 Nortel Networks All rights reserved. May 4, 2004. The information in this document is subject

More information

Upgrading Software and Firmware

Upgrading Software and Firmware APPENDIXB This appendix describes how to upgrade or reinstall the Cisco PAM server software, desktop client software, and Gateway module firmware. Contents Upgrade Notes for Release 1.1.0, page B-2 Upgrading

More information

.NET programming interface for R&S GTSL and R&S EGTSL

.NET programming interface for R&S GTSL and R&S EGTSL Application Note 2.2016 SE001_0e.NET programming interface for R&S GTSL and R&S EGTSL Application Note Products: ı R&S CompactTSVP ı R&S PowerTSVP ı R&S GTSL ı R&S EGTSL This application note describes

More information

R&S FSVA and R&S FSV Signal and Spectrum Analyzer Release Notes Firmware Version V3.40

R&S FSVA and R&S FSV Signal and Spectrum Analyzer Release Notes Firmware Version V3.40 R&S FSVA and R&S FSV Signal and Spectrum Analyzer Release Notes Firmware Version V3.40 These Release Notes are for following models of the R&S FSVA Signal and Spectrum Analyzer: Running operating system

More information

XL-NAS-400SA. User s Guide

XL-NAS-400SA. User s Guide XL-NAS-400SA User s Guide Table of Contents Chapter 1 Hardware devices 1.1 1.2 1.3 Accessories and XL-NAS-400SA at a glance LCD message and light indicators Hardware installation Chapter 2 Initial setup

More information

How to install the software of ZNS8022

How to install the software of ZNS8022 How to install the software of ZNS8022 1. Please connect ZNS8022 to your PC after finished assembly. 2. Insert Installation CD to your CD-ROM drive and initiate the auto-run program. The wizard will run

More information

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5 PREPARATION...5 CONFIGURATION SOLUTION TABLE...5

More information

Congratulations on purchasing Hawking s HWPS12UG 1-Port Parallel + 2 USB Ports Wireless G Print Server. The Hawking HWPS12UG is a powerful and

Congratulations on purchasing Hawking s HWPS12UG 1-Port Parallel + 2 USB Ports Wireless G Print Server. The Hawking HWPS12UG is a powerful and Congratulations on purchasing Hawking s HWPS12UG 1-Port Parallel + 2 USB Ports Wireless G Print Server. The Hawking HWPS12UG is a powerful and convenient network printing solution that will connect your

More information

Trend Micro Incorporated reserves the right to make changes to this document and to the product described herein without notice. Before installing and using the product, please review the readme files,

More information

R&S SMBV100A Vector Signal Generator Instrument Security Procedures

R&S SMBV100A Vector Signal Generator Instrument Security Procedures Vector Signal Generator Instrument Security Procedures (;ÚèÔ2) 1176.9070.02 02 Instrument Security Procedures Contents Contents 1 Overview... 2 2 Instrument Models Covered...2 3 Security Terms and Definitions...

More information

NET-DYN USB Dual Band (Mediatek) Installation Guide. This manual is divided into three parts: Windows XP, Windows 7 / 8 / 8.

NET-DYN USB Dual Band (Mediatek) Installation Guide. This manual is divided into three parts: Windows XP, Windows 7 / 8 / 8. Installation Guide NET-DYN USB Dual Band (Mediatek) Installation Guide This manual is divided into three parts: Windows XP, Windows 7 / 8 / 8.1 /10, and Mac 1.Windows XP Please do the following steps to

More information

R&S ELEKTRA EMC Test Software Swift and reliable measurement of electromagnetic disturbances

R&S ELEKTRA EMC Test Software Swift and reliable measurement of electromagnetic disturbances R&S ELEKTRA EMC Test Software Swift and reliable measurement of electromagnetic disturbances Product Brochure Version 01.01 R&S ELEKTRA EMC Test Software At a glance The R&S ELEKTRA EMC test software is

More information

OLI Engine in Aspen Hysys

OLI Engine in Aspen Hysys OLI Engine in Aspen Hysys This document applies to all versions of Aspen Hysys V7.3 to V8.8 The OLI Engine in Aspen Hysys includes OLI physical property databanks and OLI licensing and security components

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide h-series 800-782-3762 www.edgewave.com 2001 2011 EdgeWave Inc. (formerly St. Bernard Software). All rights reserved. The EdgeWave logo, iprism and iguard are trademarks

More information

R&S FSH4/8/13/20 Spectrum Analyzer Quick Start Guide

R&S FSH4/8/13/20 Spectrum Analyzer Quick Start Guide R&S FSH4/8/13/20 Spectrum Analyzer Quick Start Guide 1309.6269.12 07 Test & Measurement Quick Start Guide The Operating Manual describes the following R&S FSH models and options: R&S FSH4 (1309.6000.04)

More information

SMG-1100/6100 User s Manual

SMG-1100/6100 User s Manual User s Manual First Edition, January 2011 www.moxa.com/product 2011 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. User s Manual The software described in this manual is

More information

R&S SGS100A SGMA RF Source Instrument Security Procedures

R&S SGS100A SGMA RF Source Instrument Security Procedures SGMA RF Source Instrument Security Procedures (;ÙÍP2) 1175.6332.02 04 Instrument Security Procedures Contents Contents 1 Overview... 2 2 Instrument Models Covered...2 3 Security Terms and Definitions...

More information

DBT-120 Bluetooth USB Adapter

DBT-120 Bluetooth USB Adapter DBT-120 Bluetooth USB Adapter Rev.2.1 (09/25/2002) 2 Contents Introduction... 5 Package Contents... 6 Installing Bluetooth Software... 6 Hardware Installation... 8 Introduction to Bluetooth Software...

More information

GV Director Restoring USB Image / Frame and Panel Installation

GV Director Restoring USB Image / Frame and Panel Installation IMPORTANT NOTE: If you have already been provided this update package via USB by a Grass Valley service representative, please skip ahead and begin on page 4. Requirements: 16 GB USB FLASH OR LARGER Mouse

More information

ShareHub Device Server Version 2.00 (English) BEFORE GETTING STARTED

ShareHub Device Server Version 2.00 (English) BEFORE GETTING STARTED ShareHub Device Server Version 2.00 (English) BEFORE GETTING STARTED This UM is designed to aid you to get started with the device. If you experience problems following these guides or need further information

More information

R&S SpycerBox Ultra TL Spec Sheet

R&S SpycerBox Ultra TL Spec Sheet Preliminary Spec Sheet Rohde & Schwraz DVS GmbH 12.2014-

More information

FUJITSU Software ServerView Suite ServerView Installation Manager

FUJITSU Software ServerView Suite ServerView Installation Manager User Guide - English FUJITSU Software ServerView Suite ServerView Installation Manager Edition June 2017 Comments Suggestions Corrections The User Documentation Department would like to know your opinion

More information

Reinstalling the Operating System on the Dell PowerVault 745N

Reinstalling the Operating System on the Dell PowerVault 745N Reinstalling the Operating System on the Dell PowerVault 745N This document details the following steps to reinstall the operating system on a PowerVault 745N system: 1. Install the Reinstallation Console

More information

Addendum to Active Breathing Coordinator R3.0 Installation and Service. Installation Instructions for Windows 10

Addendum to Active Breathing Coordinator R3.0 Installation and Service. Installation Instructions for Windows 10 Addendum to Active Breathing Coordinator R3.0 Installation and Service Installation Instructions for Windows 10 4-16-2019 Laptop software installation A1 Laptop software installation for Windows 10 Contents

More information

Bluetooth Application Note

Bluetooth Application Note Bluetooth Application Note FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits

More information

GigaStor Upgradeable 2U. User Guide

GigaStor Upgradeable 2U. User Guide GigaStor Upgradeable 2U User Guide Table of Contents Chapter 1: Installation...1 Unpacking and inspecting the parts...1 Installing the drives in your GigaStor...1 How to handle hard drives properly...

More information

Replacing R&S CMU200 with R&S CMW500 in 2G and 3G Speech Test Applications Application Note

Replacing R&S CMU200 with R&S CMW500 in 2G and 3G Speech Test Applications Application Note Replacing R&S CMU200 with R&S CMW500 in 2G and 3G Speech Test Applications Thomas Lechner, 1GPM 17-Jul-14- Replacing R&S CMU200 with R&S CMW500 in 2G and 3G Speech Test Applications Application Note Products:

More information

R&S GP-U gateprotect Firewall How-to

R&S GP-U gateprotect Firewall How-to gateprotect Firewall How-to Setting up a VPN SSL Client-to-Site connection to an ios device (T^Wì2) 3646.3994.02 01 Cybersecurity How-to 2017 Rohde & Schwarz Cybersecurity GmbH Muehldorfstr. 15, 81671

More information

Bridge Cable User s Guide

Bridge Cable User s Guide Bridge Cable User s Guide Table of Contents Overview -------------------------------------------------------------------- 2 Driver Installation --------------------------------------------------------

More information

8380 RPC Return Path Combiner. User s Guide

8380 RPC Return Path Combiner. User s Guide 8380 RPC Return Path Combiner User s Guide Notice Every effort was made to ensure that the information in this manual was accurate at the time of printing. However, information is subject to change without

More information

User s Manual CONTENT. Nano NAS Server for USB storages. 1. Product Information Product Specifications System requirements..

User s Manual CONTENT. Nano NAS Server for USB storages. 1. Product Information Product Specifications System requirements.. CONTENT Nano NAS Server for USB storages 1. Product Information...1 2. Product Specifications.2 3. System requirements..3 4. Product Connecting. 4 5. Configuring DN-7023....5 6. Setting... 9 7. Note..

More information

R&S VSE Vector Signal Explorer Release Notes Firmware Version V1.40

R&S VSE Vector Signal Explorer Release Notes Firmware Version V1.40 R&S VSE Vector Signal Explorer Release Notes Firmware Version V1.40 These Release Notes are for following models of the R&S VSE Vector Signal Explorer: R&S VSE, order no. 1320.7500.06 2017 Rohde & Schwarz