Express5800/320Ma: System Administrator s Guide

Size: px
Start display at page:

Download "Express5800/320Ma: System Administrator s Guide"

Transcription

1 Express5800/320Ma: System Administrator s Guide NEC Solutions (America), Inc. NR014W

2 Notice The information contained in this document is subject to change without notice. UNLESS EXPRESSLY SET FORTH IN A WRITTEN AGREEMENT SIGNED BY AN AUTHORIZED REPRESENTATIVE OF NEC, NEC MAKES NO WARRANTY OR REPRESENTATION OF ANY KIND WITH RESPECT TO THE INFORMATION CONTAINED HEREIN, INCLUDING WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PURPOSE. NEC assumes no responsibility or obligation of any kind for any errors contained herein or in connection with the furnishing, performance, or use of this document. Software described in NEC (a) is the property of NEC and/or its licensees, (b) is furnished only under license, and (c) may be copied or used only as expressly permitted under the terms of the license. NEC documentation describes all supported features of the user interfaces and the application programming interfaces (API) developed by NEC and/or its licensees. Any undocumented features of these interfaces are intended solely for use by NEC personnel and are subject to change without warning. This document is protected by copyright. All rights are reserved. No part of this document may be copied, reproduced, or translated, either mechanically or electronically, without the prior written consent of NEC Solutions (America), Inc. VERITAS, VERITAS SOFTWARE, the VERITAS logo, Business Without Interruption, VERITAS The Data Availability Company, and VERITAS Volume Manager are trademarks or registered trademarks of VERITAS Software Corporation in the U.S. and/or other countries. The NEC Solutions (America), Inc. logo, Express5800/320Ma, and the Express5800/320Ma logo, are trademarks of NEC Solutions (America), Inc. ActiveService Network is a trademark of Stratus Technologies Bermuda, Ltd. All other trademarks and trade names are the property of their respective owners. Manual Name: Express5800/320Ma: System Administrator s Guide Part Number: NR014W Express5800/320Ma Software Release Number: Publication Date: January 2006 NEC Solutions (America), Inc Gold Center Drive, Suite 200 Rancho Cordova, CA NEC Solutions (America), Inc. All rights reserved.

3 Contents Preface xi 1. Introduction to System Administration 1-1 System Administration Tools 1-1 Active Upgrade 1-1 ftserver Management Console 1-2 Software Availability Manager 1-2 ActiveService Network 1-2 Virtual Technician Module 1-3 VTM Console 1-3 Disk-Management Tools 1-4 System Software Features 1-4 Fail-Safe Software 1-4 Services 1-4 Open Driver Architecture 1-4 Rapid Disk Resync Disk Mirroring 1-5 Initial Configuration 1-6 Documentation 1-6 Express5800/320Ma Help System 1-6 Windows Documentation Operating and Monitoring Your System 2-1 System Startup and Shutdown 2-1 Enabling the System Power Button 2-2 Managing CPU Element Resynchronization 2-3 Managing CPU Element Bringup 2-3 Connecting Serial Port 1 to the Modem 2-4 Controlling the Modem 2-5 Remote Access to Your System Desktop 2-5 Remote Desktop 2-5 Running ftsmc Remotely 2-6 Using VTM Console 2-6 Using the VTM 2-6 Contents iii

4 Contents Setting Up a VTM Administrator Account 2-6 Configuring VTM Administrator Paging 2-7 Configuring the SMTP and SNMP Settings 2-7 Setting Paging-Severity Levels 2-8 Windows System Event Logs 2-8 Setting the Size of Event Log Files 2-9 Archiving Event Log Files 2-9 Monitoring Stratus Services 2-9 BIOS Settings 2-10 Determining the BIOS Version 2-10 Enabling IMAPI for Writing to CDs 2-10 Floppy Disk Drive Volume Letter 2-11 Serial Ports 2-11 Uninterruptible Power Supplies 2-12 System Shutdown with UPS Battery Rundown 2-12 Changing the IP Address of Systems with a UPS 2-12 SNMP Traps 2-13 Installing Hotfixes and Security Updates 2-13 Important Things to Avoid ftserver Management Console 3-1 CPU and I/O Enclosures and Elements 3-1 ftsmc Overview 3-2 Running ftsmc 3-2 Running ftsmc Directly on Your Express5800/320Ma System 3-2 Running ftsmc on a Remote Computer 3-3 Adding the ftserver Management Console Snap-in to MMC 3-3 Virtual Modems 3-4 Using VTMs to Troubleshoot Systems 3-5 Determining the Value of the Send Alarms By Property 3-6 Opening a Previously Saved MMC Console 3-6 Running ftsmc by Remote Access 3-6 Performing ftsmc Tasks 3-6 ftsmc Interface 3-6 Details Pane 3-8 Icons Used in ftsmc 3-9 Refreshing the ftsmc Display 3-11 Viewing and Changing Properties 3-12 Required Operational States for Commands 3-13 iv Express5800/320Ma: System Administrator s Guide

5 Contents 4. Disk Storage Management 4-1 Data Fault Tolerance 4-1 Guidelines for System Disks 4-2 Using RDR for Fault Tolerance 4-2 Automatic Virtual Disk Expansion 4-3 Managing RDR Disks 4-4 Notes on Using RDR to Mirror Disks in Internal Storage 4-5 Disk Failures during Resynchronization 4-5 Write Caching 4-6 Read-load Balancing 4-6 Mirroring Dynamic Disks with RDR 4-10 Setting the Active RDR Disk (Plex) 4-10 Deleting the RDR Configuration on a Physical Disk 4-11 Removing a Physical Disk from an RDR Virtual Disk 4-12 Deporting a Physical Disk from an RDR Virtual Disk 4-13 Creating a Spare Bootable RDR Disk 4-14 Breaking a Physical Disk from an RDR Virtual Disk 4-14 Setting or Clearing the MTBF for Disks 4-15 Setting the MTBF Faultcount Limit for Disks 4-15 Booting a System with a Backup RDR Boot Disk 4-16 Reusing Data Disks 4-16 Reusing a Stored-Data Disk 4-16 Removing the RDR Configuration from a Stored-Data Disk 4-16 Resynchronizing RDR Disks 4-17 Resynchronizing a Backup Boot RDR Disk 4-18 Recovering and Replacing RDR Disks 4-18 Verifying RDR Disks 4-19 Configuring the Priority of RDR Virtual Disk Resynchronization 4-20 Using Volume Mirroring for Fault Tolerance 4-20 Mirrored Volume Resynchronization 4-21 Volume Resynchronization After Rebooting 4-21 Inserting or Removing More Than One Disk at a Time 4-22 ftsmc Interface for Storage Enclosures and Subsystems 4-22 Storage Enclosure Node 4-23 Slot Node 4-23 Disk Node 4-23 Sensor Nodes 4-23 EMC Attached Storage 4-24 Mirroring Disks in Your Express5800/320Ma System 4-24 Mirroring Disks in Internal Storage 4-25 Configuring and Creating RDR Disks 4-25 Contents v

6 Contents Finding a Physical Disk 4-25 Finding an Internal Physical Disk 4-25 Finding an External Physical Disk Troubleshooting 5-1 MTBF Statistics 5-1 Clearing the MTBF 5-2 Changing the MTBF Threshold 5-2 Taking Components Offline and Bringing Them Online 5-2 Hard Disks 5-2 Recovering a Disk 5-2 Replacing a Failed Disk in Windows Disk Management 5-3 Replacing a Failed Disk with an Uninitialized Disk 5-4 Replacing a Failed Disk with an Initialized Disk 5-4 Hardware Installation Wizard 5-5 Determining That a Component Has Failed 5-5 Using LEDs to Troubleshoot Hardware 5-5 Using ftsmc to Troubleshoot Hardware 5-5 Locating Components 5-6 Device IDs and Device Paths 5-6 Diagrams of Component Locations 5-8 System Elements and Internal Storage Disk Locations 5-8 When Windows Does Not Respond 5-9 Delayed System Restart 5-9 Unresponsive Mouse and Keyboard 5-10 Remote Event Notification and Service 5-10 Remote Reporting of Events 5-10 Autonomous Call Home 5-10 System Inventory Reports 5-10 SNMP Traps 5-10 Event-Log Entries 5-11 Remote Service 5-11 Making Dump Files 5-11 Using the Dump Button 5-12 System Memory Dumps 5-12 Dump and Go 5-13 Online Diagnostic Codes 5-13 Disaster Recovery 5-14 Safe Mode 5-14 Booting From a Spare System Disk 5-14 WinPE 5-15 Windows Hotfixes Distributed by NEC Solutions (America), Inc vi Express5800/320Ma: System Administrator s Guide

7 Contents Appendix A. Advanced Topics A-1 Disabling Hyperthreading A-1 Using Windows Headless Mode and Console Redirection A-2 Security Configuration Wizard A-2 Appendix B. Online Diagnostic Codes B-1 Online Diagnostic Test Codes B-1 CPU Diagnostic Test Codes B-1 I2C Bus Diagnostic Test Codes B-3 Primary I/O Element Diagnostic Test Codes B-4 Secondary I/O Element Diagnostic Test Codes B-10 Index Index-1 Contents vii

8 Figures Figure 3-1. ftsmc Tree 3-4 Figure 3-2. Virtual Modems 3-5 Figure 3-3. ftsmc User Interface 3-7 Figure 3-4. Details Pane 3-8 Figure 3-5. System Inventory Icons 3-9 Figure 3-6. Simplexed Icon for Invalid Configuration 3-10 Figure 3-7. Warning and Error Icons 3-10 Figure 3-8. Warning and Inventory Error Icons 3-11 Figure 3-9. Threshold Warning Icon 3-11 Figure ftsmc Details Pane Refresh Options 3-12 Figure Properties Command in Shortcut Menu 3-12 Figure 4-1. Mirroring RDR Virtual Disks 4-8 Figure 5-1. Warning and Error Icons 5-6 Figure 5-2. Component Levels 5-7 Figure 5-3. CPU-I/O Enclosure, and Disk Slot Labeling 5-9 viii Express5800/320Ma: System Administrator s Guide

9 Tables Table 3-1. ftsmc User Interface Key Elements 3-7 Table 3-2. ftsmc Warning and Error Icons 3-10 Table 3-3. Operational State for Associated Commands 3-13 Table 4-1. RDR Disk Numbering 4-7 Table 4-2. FC Host Bus Adapter State and Reason Property Values 4-24 Table 5-1. System Devices and Device IDs 5-7 Tables ix

10 Tables x Express5800/320Ma: System Administrator s Guide

11 Preface Purpose of This Manual Audience The Express5800/320Ma: System Administrator s Guide documents tasks and information for system administrators of Express5800/320Ma systems. This manual is intended for anyone who administers or troubleshoots Express5800/320Ma systems. Notation Conventions This document uses the notation conventions described in this section. Warnings, Cautions, and Notes Warnings, cautions, and notes provide special information and have the following meanings:! WARNING A warning indicates a situation where failure to take or avoid a specified action could cause bodily harm or loss of life.! CAUTION A caution indicates a situation where failure to take or avoid a specified action could damage a hardware device, program, system, or data. NOTE A note provides important information about the operation of an Express5800/320Ma system. Typographical Conventions The following typographical conventions are used in ftserver documents: Preface xi

12 Preface The bold font emphasizes words in text or indicates text that you type, the name of a screen object, or the name of a programming element. For example: Before handling or replacing system components, make sure that you are properly grounded by using a grounded wrist strap. In the System Properties dialog box, click the Hardware tab. Call the RegisterDeviceNotification function. The italic font introduces new terms and indicates programming and command-line arguments that the user defines. For example: Many hardware components are customer-replaceable units (CRUs), which can be replaced on-site by system administrators with minimal training or tools. copy filename1 filename2 Pass a pointer for the NotificationFilter parameter The monospace font indicates sample program code and output, including message text. For example: #include <iostream.h> The operation completed successfully. Getting Help If you have a technical question about Express5800/320Ma hardware or software, try these online resources first: Online support from NEC Technical Support. You can find the latest technical information about an Express5800/320Ma through online product support at the NEC Technical Support Web site: Online product support for Microsoft products. Your primary source for support is the computer manufacturer who provided your software, or an authorized Microsoft Support Provider. You can also find the latest technical information about Microsoft Windows and other Microsoft products through online product support at the Microsoft Help and Support Web site: If you are unable to resolve your questions with the help available at these online sites, and the Express5800/320Ma system is covered by a service agreement, please contact NEC Technical Support ( ). xii Express5800/320Ma: System Administrator s Guide

13 Preface Notices All regulatory notices are provided in the site planning guide for your system. Although this guide documents modem functionality, modems are not available for all systems. Ask your sales representative about modem availability. ActiveService Network (ASN) is not currently available, but may be ordered in the future. Preface xiii

14 Preface xiv Express5800/320Ma: System Administrator s Guide

15 Chapter 1 Introduction to System Administration1- The following topics provide an introduction to Express5800/320Ma system administration. System Administration Tools on page 1-1 System Software Features on page 1-4 Initial Configuration on page 1-6 Documentation on page 1-6 Windows Documentation on page 1-7 Features of Express5800/320Ma system software further support system fault-tolerance for properly configured systems. If you have a service contract, NEC Solutions (America), Inc. or an authorized service representative provides continuous, remote, system monitoring and diagnosis for ActiveService Network (ASN) management. Disk-management tools are also available on your Express5800/320Ma system. System Administration Tools System administration tools enable you to monitor system performance and system-component status, diagnose errors, and identify failed components. Using the tools, you can take failed components offline and put replacement components online. These features include Active Upgrade, ftserver Management Console, Software Availability Manager (SAM), ActiveService Network (ASN), Virtual Technician Module (VTM), the VTM console, and disk-management tools. Active Upgrade Optional Active Upgrade technology enables you to upgrade your Express5800/320Ma system and application software with minimal downtime. Instead of taking your system offline to run upgrade procedures, you can use the Active Upgrade process to split the system into two independently-running systems, one Introduction to System Administration 1-1

16 System Administration Tools side of which you upgrade while the other side continues to run your applications without interruption. See the Express5800/320Ma: Active Upgrade User s Guide or the Active Upgrade online help for more information. To use Active Upgrade, your system requires a VTM. ftserver Management Console The ftserver Management Console (ftsmc) is a graphical user interface that enables you to monitor and manage your system s fault-tolerant software and hardware. See Chapter 3 for details. Software Availability Manager The Software Availability Manager (SAM) performs predictive software availability management. SAM monitors system activity to predict possible software failures and to alert you to take action. SAM is a Microsoft Management Console (MMC) snap-in supplied by NEC Solutions (America), Inc. See the Express5800/320Ma Software Availability Manager User s Guide for complete information. ActiveService Network Your Express5800/320Ma systems offers an optional, secure network, the ActiveService Network (ASN). ASN enables NEC Technical Support or your authorized service representative to provide remote monitoring, diagnosis, troubleshooting, and problem-resolution services to your systems 24 hours a day, 7 days a week. Access to the ASN requires a service contract with NEC Solutions (America), Inc. or an authorized service representative and is implemented across a modem or over the Internet. Having ASN connectivity enables: Your system to send alerts (call-home alarm messages) to NEC Technical Support or your authorized service representative when unusual events occur on the system NEC Technical Support or your authorized service representative to access the system through a connection to the ASN Your system can connect to the ASN through: A modem connected to the system The VTM or an ftgateway system (a system configured as a gateway for ASN connectivity) The Internet 1-2 Express5800/320Ma: System Administrator s Guide

17 System Administration Tools Internet-based ASN connects over a secure path to your authorized service representative. Internet-based ASN does not support ftgateway. After verifying a hardware problem, your authorized service representative can send out a replacement CRU. See the Express5800/320Ma ActiveService Network Configuration Guide for more information. Virtual Technician Module The Virtual Technician Module (VTM) is a system-management module supported on your Express5800/320Ma system. VTMs provide remote-management capabilities using the VTM console (a Web-based console), including: Advanced Video Redirection (AVR) Access to attached storage Diagnosis of a system that is without power Power-cycling of a system VTM is required for the use of Active Upgrade. AVR enables you to manage the host computer remotely over the Web-based console. Using AVR, you can view the remote system desktop and redirect its local keyboard and mouse. VTM supports Dynamic Host Configuration Protocol (DHCP). DHCP dynamically assigns IP addresses to the VTMs, and also supports static IP addresses. The two VTMs on each VTM-equipped system require a total of four IP addresses. VTM Console The VTM console is the Web-based interface for systems that support VTM. The VTM console enables you, NEC Technical Support, or your authorized service representative to control, monitor, and diagnose the system. You can access the VTM console over a LAN or modem. Because the VTM console is Web-based, you can use it in a Web browser from any location. You can use the VTM console even if the host system s operating system is out of operation and its network connections are lost. Introduction to System Administration 1-3

18 System Software Features Disk-Management Tools Disk-management tools enable you to monitor disk status, mirror entire physical disks, create logical volumes, mirror volumes across multiple disks, and perform other data-storage operations. For information, see Chapter 4 and the Windows Server 2003 documentation. See also Rapid Disk Resync Disk Mirroring on page 1-5. System Software Features Express5800/320Ma System Software has features designed to support fault-tolerant operation and high availability. These features include fault-tolerant, fail-safe software, services, open architecture drivers, and Rapid Disk Resync disk mirroring. Fail-Safe Software Services Express5800/320Ma System Software works in conjunction with lockstep technology to prevent many software errors. Fail-safe software features capture issues and report them to NEC Technical Support or your authorized service representative. Even data in memory can be constantly protected and maintained. NEC Solutions (America), Inc. also provides drivers that increase the fault tolerance and manageability of third-party drivers for other adapters in the system. NEC Solutions (America), Inc. provides software fault-tolerant services that run on your system as Windows-based services. These services constantly monitor for, and respond to, hardware problems. Applications do not need customization to support the services. These services start automatically when the system boots and remain running during normal operation. If a situation requires system administrator intervention, you can use Computer Management to manually start and stop system services. See Monitoring Stratus Services on page 2-9 for details. See the Express5800/320Ma: Technical Reference Guide for descriptions of the Stratus services. Open Driver Architecture Your Express5800/320Ma system supports both vendor-supplied drivers and NEC-supplied drivers for PCI adapters. For PCI adapters that you supply, your Express5800/320Ma system supports vendor-supplied drivers. For PCI adapters that NEC Solutions (America), Inc. provides, NEC Solutions (America), Inc. supplies drivers that it has enhanced with support for surprise removal. 1-4 Express5800/320Ma: System Administrator s Guide

19 System Software Features In addition, your Express5800/320Ma system uses other drivers developed by NEC Solutions (America), Inc. These drivers allow the system and all PCI devices to integrate with the ASN, and provide management of all system devices and device fault-tolerance. ASN integration provides: Automatic reporting of device failures to the NEC Technical Support Notification to you by the NEC Technical Support when a device fails Inventory reporting to the NEC Technical Support that lists all PCI devices in the system Comprehensive debug information about all devices in the system for use by the NEC Technical Support in troubleshooting your system Management of PCI devices includes: On your Express5800/320Ma system, hot-plug support alerts the plug-and-play manager to bring a device into service or take it out of service. You can initiate bring-up or bring-down from ftsmc. Hot-plug support also initiates discovery of newly attached or removed devices. NOTE You must remove the CPU- I O enclosure from the system in order to remove a PCI adapter. Display of information so that you know whether removing a device will compromise the system. The drivers can set LEDs and values in ftsmc that let you know whether you can safely remove a component. Display of information about the device in ftsmc. Device fault-tolerance includes: Automatic restart of failed devices. The device will be restarted after transient faults, until it falls below its mean-time-between faults (MTBF) threshold. Tracking the MTBF of a device and management of the device when it experiences faults. You can set parameters to take the device out of service when the device experiences an unacceptable MTBF. You can configure the rules for MTBF management. Rapid Disk Resync Disk Mirroring Rapid Disk Resync (RDR) disk-mirroring technology provides faster resynchronization of mirrored disks than other mirroring methods after transient failures or when a single Introduction to System Administration 1-5

20 Initial Configuration disk is briefly removed from service. For optimal performance, use RDR to mirror disks in internal storage. Initial Configuration Configure the following items before you use your system: System Software. See the Express5800/320Ma: Software Installation and Configuration Guide for software installation and configuration details. Disk storage. Create a backup system disk and mirror the disks in your system. If you are implementing RDR disk mirroring, see the Express5800/320Ma: Software Installation and Configuration Guide for details. If you are implementing volume mirroring, see your disk-management tool documentation. Network connections. Configure Ethernet adapters in teams to achieve increased throughput and fault tolerance. In a team, one adapter is primary and the other adapters in the team are secondary. See the Express5800/320Ma: Software Installation and Configuration Guide and the Express5800/320Ma: PCI Adapter Guide for details about configuring Ethernet adapter teams. Uninterruptible power supply. See your system s hardware installation guide for information about connecting a UPS to a system. See the Express5800/320Ma: Software Installation and Configuration Guide for information about how to configure a UPS for use with your system. Documentation The Express5800/320Ma: Site Planning Guide provides lists of Express5800/320Ma system documentation. You can find additional information in the online Help system. Express5800/320Ma Help System The Express5800/320Ma Help system consists of the following: General Help. You can access this help from the Help button on an application s menu bar, or by pressing F1. Context-Sensitive Help. This help is available for certain items within help-enabled applications (such as the ftsmc snap-in). To access this help, select an icon in the ftsmc system inventory tree and press F1. Alternatively, right-click an ftsmc system inventory tree icon, and in the shortcut menu, click Help. What s This? Help for ftsmc. This help is available for items in the details pane of the ftsmc snap-in. To access this help, right-click the question mark (?) icon in front of the item, and in the shortcut menu, click What s this?. See Figure 3-4 for an example. This help is also available from certain dialog boxes having the What s this? help icon (?) in their upper-right corner. For example, in a Properties 1-6 Express5800/320Ma: System Administrator s Guide

21 Windows Documentation dialog box in ftsmc, click the help icon (?), then click a box, and a pop-up window is displayed. Windows Documentation This manual does not document system administration tasks that you perform as an administrator of a Windows-based server unless there are associated tasks that are specific to your systems. System administration tasks include: Configuring networks and managing access to network resources Configuring Windows Server 2003 services Configuring domain controllers Implementing and managing Active Directory Setting up user accounts and managing users Setting up and configuring printers Managing server security Backing up and restoring data For help with these kinds of tasks, see the associated Microsoft Help system and the Microsoft documentation provided with Windows Server Introduction to System Administration 1-7

22 Windows Documentation 1-8 Express5800/320Ma: System Administrator s Guide

23 Chapter 2 Operating and Monitoring Your System2- For information about system operation, see the following topics: System Startup and Shutdown on page 2-1 Controlling the Modem on page 2-5 Remote Access to Your System Desktop on page 2-5 Using the VTM on page 2-6 Windows System Event Logs on page 2-8 Monitoring Stratus Services on page 2-9 BIOS Settings on page 2-10 Enabling IMAPI for Writing to CDs on page 2-10 Floppy Disk Drive Volume Letter on page 2-11 Serial Ports on page 2-11 Uninterruptible Power Supplies on page 2-12 SNMP Traps on page 2-13 Installing Hotfixes and Security Updates on page 2-13 Important Things to Avoid on page 2-14 System Startup and Shutdown For normal system startup and shutdown, and to completely remove power from the system, see the operation and maintenance guide for your system.! CAUTION Always shut down the operating system before turning the system power off. Operating and Monitoring Your System 2-1

24 System Startup and Shutdown NOTES 1. Give the system time to recover automatically from problems. If the system hangs for any reason while it is booting, wait at least ten minutes before intervening manually. 2. If a system contains failed components, it may attempt to boot for an extended period of time. This is because the system makes up to six attempts to boot, each time trying with a different combination of components. You can monitor the boot process on the screen or in a VTM console session. You can accomplish an orderly shutdown of the system from a remote computer by accessing the Windows desktop and choosing Shut Down from the Start menu. You must physically be at the system to see the message indicating that it is safe to power off the system. To turn off power, use the power button, the standby circuit-breaker switches, or the VTM console. Note, however, that the Windows Shut Down command automatically powers down the system. Enabling the System Power Button The system power button performs an orderly shutdown when pressed once. However, if no one is currently logged onto the system, the power button may not work properly on all versions of the Windows operating system. You may need to enable the system power button to operate correctly in the event that no one is logged onto a system. To enable the system power button to shut down a system onto which no one has yet logged, enable the following Windows Security option: Shutdown: Allow system to be shutdown without having to log on For information about enabling this option, refer to the Windows Help topic To edit a security setting on a Group Policy object and follow the instructions for a Local computer or a Group Policy object. 2-2 Express5800/320Ma: System Administrator s Guide

25 System Startup and Shutdown Managing CPU Element Resynchronization On systems running Windows Server 2003 Standard Edition, a CPU element returning to service must resynchronize with the functioning CPU element. A CPU element requires resynchronization: After bringing down and then bringing up a CPU element After a transient CPU element error After powering down a system and then powering it up During online BIOS upgrade During the resynchronization period, the system will not respond to network connections. Therefore, it is important to set the timeout period and/or number of retries for network applications to be large enough to prevent timeouts during resynchronization. The length of the resynchronization period is proportional to the amount of system memory configured. By default, resynchronization occurs as soon as the CPU element that was taken out of service is determined to be operational or the failed enclosure is replaced. However, you can defer resynchronization to a more convenient time, such as an off-peak period. See the ftsmc help for information about scheduling CPU bringup. Managing CPU Element Bringup You can specify two times of day at which to enable, or to which to defer, the return to service of CPU elements that have been removed from service (shot). You use two commands Enable CpuBoard Bringup and Defer CpuBoard Bringup which the Windows Scheduler executes. Along with the commands, you specify two times of day: one time when an offline CPU element can be brought up, and another time to which CPU Bringup is deferred. See the ftsmc snapin Help for instructions in setting these commands. When Scheduler executes the commands, Enable CpuBoard Bringup changes the CpuBringUpPolicy property under the Srabid driver to Enable Bringup. This setting enables CPU elements that were removed from service to come back into service. It also brings up any CPUs that are in the Removed from Service state for a reason of Deferred BringUp, as long as they don't exceed the MTBF threshold. When Scheduler executes the Defer CpuBoard Bringup command, it changes the CpuBringUpPolicy property under the Srabid driver to Defer Bringup. With this setting, if a CPU element is removed from service, the CPU elements come back into service at different times. For example, consider the situation in which Defer CpuBoard Bringup is scheduled for every day at 8 a.m., and Enable CpuBoard Bringup is scheduled for every day at 9 p.m. In this case, if any CPU element gets removed from service after 8 a.m., it will not be Operating and Monitoring Your System 2-3

26 System Startup and Shutdown allowed to come back into service until after 9 p.m., when Scheduler executes Enable CpuBoard Bringup. At that time, Enable CpuBoard Bringup will automatically bring up any CPU element that has been deferred between 8 a.m. and 9 p.m. Connecting Serial Port 1 to the Modem On systems that have modems and no VTMs, you must change a BIOS setting to enable Serial Port 1 (also known as Serial Port A) to connect to the modem. Without this change in the BIOS settings, the system will not allow the internal modem to use Serial Port 1, and the port will remain available for any other serial port connection. When performing this procedure from the ftserver Setup utility, use the arrow keys to navigate within the utility. You can also change the BIOS setting from ftsmc while the system is running by performing the procedure that follows this one. To change the BIOS setting during a system reboot 1. Shutdown and reboot the system. 2. While the system is rebooting, press the F2 key to enter the ftserver Setup utility. The system may take a minute or so to display the ftserver Setup utility Main menu. 3. On the ftserver Setup menu, select the Advanced tab. 4. On the Advanced tab, select I/O Device Configuration, then press Enter. 5. Select Serial PortA Connection, then press Enter. 6. Use the plus key (+) to toggle to Internal Modem, then press Enter. 7. Press Esc, then select Exit Saving Changes and press Enter. 8. At the Setup Confirmation dialog box (with Yes highlighted), press Enter to return to the system boot process. To change the BIOS setting from ftsmc with the system running 1. In ftsmc, expand ftserver (Local), ftserver Drivers, right-click the BIOS Setup node, and select Properties. 2. In the BIOS Setup Properties page, set the ComAModem property to True, and click OK. 3. Restart the system to enable the BIOS update to take effect. 2-4 Express5800/320Ma: System Administrator s Guide

27 Controlling the Modem Controlling the Modem! CAUTION When you replace or install a modem, you must turn power to the modem connector off to prevent damage to the modem and the system. Use the following procedure to change the power state of the modem while the system remains online. Otherwise, shut down the system and remove the power cords, as described in the Express5800/320Ma: Operation and Maintenance Guide. Powering the modem on or off while the system is online 1. In ftsmc, expand ftserver (Local) and ftserver Call Home Modem. 2. Refer to the PowerState property in the details pane, or the state of the power (green) LED on the modem, to verify that the power is on or off. 3. If the modem power is on, select Initiate BringDown to turn it off. If the modem power is off, select Initiate BringUp to turn it on. Remote Access to Your System Desktop You can remotely access your system s Windows desktop in different ways, depending on how your system is set up. Remote Desktop and VTM console enable remote access to the Windows desktop from a remote computer. Remote Desktop Microsoft Remote Desktop is installed by default on your system. However, it is not enabled by default. To enable Remote Desktop 1. Right-click My Computer and select Properties. 2. In System Properties, click the Remote tab. 3. Select the check box under Remote Desktop to enable users to connect remotely to the computer. 4. The Remote Sessions dialog box will appear, stating that some local accounts might not have passwords. Click OK. Operating and Monitoring Your System 2-5

28 Using the VTM NOTE Users must have passwords to access remote desktops with the Remote Desktop application. See Microsoft documentation for details. Running ftsmc Remotely See Running ftsmc on a Remote Computer on page 3-3 or Running ftsmc by Remote Access on page 3-6 for details about running ftsmc on a remote system. Using VTM Console If your system has VTMs, you can use VTM console to remotely access the server desktop to turn off system power and boot the host system. See the Express5800/320Ma Virtual Technician Module User s Guide for more details.! CAUTION Before using the VTM console to turn off system power, always attempt to perform an orderly shutdown of the operating system. Using the VTM Using the VTM includes the following major procedures: Setting Up a VTM Administrator Account on page 2-6 Configuring VTM Administrator Paging on page 2-7 Configuring the SMTP and SNMP Settings on page 2-7 Setting Paging-Severity Levels on page 2-8 See Using VTMs to Troubleshoot Systems on page 3-5 for related information. Setting Up a VTM Administrator Account You set up a VTM administrator account, which enables you to log on to the VTM Console, from the ftsmc. (Note that the VTM administrator account is separate from your Windows administrator account.) 2-6 Express5800/320Ma: System Administrator s Guide

29 Using the VTM To set up a VTM administrator account 1. In ftsmc, expand ftserver (Local), ftserver Configuration, right-click ActiveService Network, and select Properties. 2. On the dialog box, click the SMM tab. 3. Enter values into the following fields: SMM Admin ID. Your VTM administrator login name. SMM Admin Password. Your VTM administrator password. SMM Admin Dialback Number. The phone number you use to dial in to the VTM adapter. After you dial in and are authenticated as the Admin, the VTM hangs up the connection and dials the dialback number to reestablish the connection. 4. Click OK. Configuring VTM Administrator Paging You can configure your VTM to you VTM alerts. Verify that your SMTP server IP address is correct if you are enabling paging. To configure VTM administrator paging 1. In ftsmc, expand ftserver (Local), ftserver Configuration, right-click ActiveService Network node, and select Properties. 2. In the properties page, click the SMM tab. 3. In the SMM Admin Enable box, set the value to False to disable or True to enable the sending of VTM alerts. 4. In the SMM Admin Address box, enter your address. 5. Click OK. Configuring the SMTP and SNMP Settings Configure the Simple Mail Transfer Protocol (SMTP) and Simple Network Management Protocol (SNMP) settings to indicate the IP addresses to use for VTM notification and for communication between the VTM and the SMTP/SNMP servers. Contact your network administrator for the correct addresses. To configure SMTP and SNMP settings 1. In ftsmc, expand ftserver (Local), ftserver Configuration, right-click VTM Network Config node, and select Properties. 2. On the VTM Network Config Properties page, click the SMTP/SNMP tab. 3. Enter values for the following properties: Operating and Monitoring Your System 2-7

30 Windows System Event Logs SMTP Server IP. A required value: The IP address of your server. SNMP Community. A required value: A filter for incoming SNMP messages and outgoing SNMP traps. SNMP Server 1 7 IP. The IP addresses of the SNMP servers that receive VTM SNMP traps. 4. Click OK. Setting Paging-Severity Levels Set the paging-severity level to notify users when entries are made in the VTM system event log (SEL). Use the settings to indicate how severe an error must be before you receive a notification about it. These are errors that relate to a particular area of the VTM adapter; for example, power, temperature sensors, and so on. The available security levels are: None. The user notification for this group is inactive. Warning. The VTM notifies users when SEL entries in this group exceed warning thresholds. Critical. The VTM notifies users when SEL entries of the group exceed critical thresholds. All. The VTM notifies users of every SEL entry of events in the group. After you set or change the paging-severity levels, the VTM reboots. To set paging-severity levels 1. In ftsmc, expand ftserver (Local), ftserver Configuration, right-click VTM Network Config, and select Properties. 2. On the VTM Network Config Properties page, click one of the Paging Severity tabs and set values, as desired, for the displayed properties. Set values on the other Paging Severity tab the same way. 3. Click OK. Windows System Event Logs The system maintains logs of application and system events. These event logs can help you, or the NEC Technical Support, if problems occur on the system. In the Windows Administrative Tools, you can use Event Viewer to view the different logs and to set the size of the application and system event logs. To prevent loss of event log data, maintain a regular schedule for manually archiving event log files or obtain a third-party tool that performs automated event-log archiving. 2-8 Express5800/320Ma: System Administrator s Guide

31 Monitoring Stratus Services Setting the Size of Event Log Files Specify the size of the event log files on your system. To set the size of the application and system event logs 1. Right-click the log in Event Viewer and click Properties. 2. In the Log size section, set the maximum log size in KB. The system default size for the application and system event logs is 2048 KB.! CAUTION Data will be overwritten if one of these event logs reaches its maximum log size. Archiving Event Log Files In the unlikely event that your system experiences problems, take a snapshot of the system event log and the application event log, and save each of these to a file in order to capture important details relevant to the problem. To save log files 1. Right-click the log file in Event Viewer. 2. Select Save Log File As. 3. In the Save Log File As dialog box: In the Save In: box, accept the default or enter a new path name. In the File name: box, enter the file name. In the Save as type: box, accept the default type, Event Log (*.evt). This allows you to view the saved file in Event Viewer. 4. Click Save to save the file. 5. After you archive the log file, you can clear it. To clear the log, click Action, and then click Clear all Events. Archiving the log file has no effect on the current contents of the active log. Monitoring Stratus Services ftserver Manager includes a number of Stratus services that run on your system as Windows services. If any of these services is not running, the system does not function as designed. The Express5800/320Ma: Technical Reference Guide describes these services. Operating and Monitoring Your System 2-9

32 BIOS Settings To check the status of a service 1. Click Start, point to Programs, point to Administrative Tools, and then click Computer Management. 2. Double-click Services and Applications, and then click Services. 3. In the right-hand pane, in the Status column, the Stratus services should all be listed as Started. In the Startup Type column, they should all be listed as Automatic. If a service s status is Stopped or blank, attempt to start the service by right-clicking it, and then clicking Start. If the service fails to start, check the event log for any messages related to the service. NOTE The Sysmgt Startup service runs only when the system first starts. This service starts the other system services. After the other services have started, it stops running and its status is blank. BIOS Settings To manage BIOS settings, your Express5800/320Ma system uses the ftserver Setup utility. To start the BIOS setup utilities 1. Turn on or reboot your system. When the logo screen appears, press F2 to enter the BIOS setup utility. 2. After executing some power-on self-test (POST) procedures, the system displays the setup utility s Main menu. See the Express5800/320Ma: Technical Reference Guide for cautions and details about using the BIOS Setup utilities. Determining the BIOS Version Use ftsmc to determine the BIOS version. Click a CPU Enclosure node and look at the value of the BIOS: Stratus Version property in the details pane. Enabling IMAPI for Writing to CDs Your Express5800/320Ma system supports optional DVD±RW drives. Before writing to the DVD±RW drive, enable the Image Mastering Applications Programming Interface (IMAPI), which is turned off by default Express5800/320Ma: System Administrator s Guide

33 Floppy Disk Drive Volume Letter To enable IMAPI 1. Right-click My Computer. 2. Click Manage, expand Services and Applications, and click Services. 3. In the Services window, double-click IMAPI CD-Burning COM Service. The IMAPI CD-Burning COM Service Properties dialog box appears. 4. In the dialog box, under Service Status: Stopped, click the Start button. A message stating that Windows is attempting to start the IMAPI service appears. When the service is started, the Service Status value changes to Started. 5. On the General tab under Startup type, select Automatic. 6. Click OK. Floppy Disk Drive Volume Letter The operating system generally assigns the drive letter A to the optional floppy disk drive when the drive is first connected to a USB port. If you subsequently connect the drive to a different USB port or if the I/O element or element fails over, the operating system may assign the drive letter B to the floppy disk drive. Serial Ports On your system: Serial Port 1 is generic if: The system uses VTMs. (In this case, the BIOS setting in the Advanced menu, under I/O Device Configuration, Serial PortA Connection is set to Serial.) The system does not have VTMs, and you have set the Serial PortA Connection to Serial and disabled the ASN. (The ASN is disabled when the ASN Call-home Enable and Call-in Enable properties are both set to False. See the ActiveService Network node properties in ftsmc under the ftserver Configuration node.) Serial Port 1 is not generic if: The Serial PortA Connection setting is Internal Modem. There is no VTM in the system and the ASN is enabled. Serial Port 2 is always generic. If you have configured Serial Port 1 or Serial Port 2 on your system to function as a modem or as a communications cable between two computers, use Windows Device Manager (see Figure 3-2) to verify that Serial Port 1 or Serial Port 2 functions as you Operating and Monitoring Your System 2-11

34 Uninterruptible Power Supplies expect after you install VTMs. You may need to reconfigure the COM port after installing the VTMs. See Virtual Modems and Using VTMs to Troubleshoot Systems on page 3-5 for related information. Uninterruptible Power Supplies Your Express5800/320Ma system supports the use of uninterruptible power supplies (UPSs) to power the system without interruption during short outages, and to gracefully shut the system down during longer power outages. As part of your fault-tolerant strategy, obtain and use a UPS qualified by NEC Solutions (America), Inc. For information about qualified UPS models, see the site planning guide for your system. For UPS installation details, see the Express5800/320Ma: Software Installation and Configuration Guide. System Shutdown with UPS Battery Rundown When you use a UPS qualified by NEC Solutions (America), Inc., you connect that UPS to one half of the system. If a failure occurs in the UPS or in the UPS power source (for example, if the UPS is unplugged) and the backup battery runs low, the system initiates a shutdown, even if the power to the non-ups half of the system is unaffected by the failure. If you have independent sources of AC power available for your system, you can minimize the possibility of this kind of shutdown by connecting the UPS to the more reliable power source. However, failure of the more reliable power source can shut down the system even if the less reliable source is still operational. Changing the IP Address of Systems with a UPS If you change the IP address on the system, update the configuration on the UPS with the new IP address. If you do not update the UPS, and power to the system is automatically removed after a power failure, the system does not restart when power is restored. NOTE Assign a static IP address to the network interface that provides the connection to the UPS Express5800/320Ma: System Administrator s Guide

35 SNMP Traps To change the IP address of systems with a UPS 1. On your system, use Add or Remove Programs to remove PowerChute Network Shutdown (PCNS). 2. Remove the old IP address from the configuration on the UPS. a. In a Web browser, enter and the IP address of the UPS; for example, b. If prompted for a password, supply a valid password for the UPS. c. In the left column of the Network Management Card page, click the name of the UPS. d. In the left column, click PowerChute. e. In the right column, next to Configured Client IP Addresses, click the old IP address and click Remove. 3. Install PCNS on the system again to register the new IP address of the system with the UPS. See the instructions for installing PCNS in the Express5800/320Ma: Software Installation and Configuration Guide. SNMP Traps Your Express5800/320Ma system supports the Microsoft SNMP Agent, which enables third-party Enterprise Management consoles to remotely monitor the systems. The ftserver SNMP Agent provides a standard mechanism for monitoring the status of systems and for receiving alarms from the systems. During instances of system malfunction or in response to a system event, such as a firmware update, you may see multiple traps in third-party management consoles for various devices. For instance, if a PCI adapter fails, the SNMP agent may send traps not only for the adapter but also for its slot. You may safely disregard these traps. See the Express5800/320Ma: Software Installation and Configuration Guide for SNMP configuration information. Installing Hotfixes and Security Updates Use caution when applying hotfixes from any source. Applying updates indiscriminately may introduce serious problems to your Express5800/320Ma system. Refer to the following guidelines before updating your system: Do not install other types of hotfixes, such as Microsoft patches that fix a particular problem, before obtaining validation from NEC Solutions (America), Inc. You can use Windows Automatic Update to download hotfixes, but do not allow Windows to install them automatically. Operating and Monitoring Your System 2-13

36 Important Things to Avoid You can greatly reduce application downtime when you upgrade software by installing and using the optional Active Upgrade software. If you do plan to install and use Active Upgrade software, be sure to keep system files on a separate disk from data files. See the Express5800/320Ma: Active Upgrade User s Guide for more information. For more information about evaluating hotfixes for Express5800/320Ma systems, see the following web page: Important Things to Avoid To take full advantage of your system s fault-tolerant features, observe the following when setting up and operating your system: Do not attempt to boot the system from a network drive. Booting the system from a network drive is not supported. Do not use Windows Device Manager to disable devices except in documented special situations. Using Windows Device Manager to disable devices can interfere with the proper operation of your system. The correct way to take devices out of service and return them to service is through the ftsmc snap-in. However, to handle special situations, the system documentation may instruct you to use the Windows device manager. Do not enable hardware acceleration for your video adapter. For your system, the Hardware acceleration is set to None. Do not change this setting. Enabling hardware acceleration makes your video adapter non-fault-tolerant. (To verify the setting, right-click the desktop and click Properties. On the Settings tab, click Advanced and then click the Troubleshooting tab.) Do not install devices unless they have been tested and certified ftserver-compatible. Installing devices that have not been tested and certified ftserver-system-compatible can reduce the fault tolerance of your system. If you want to install a device that has not been certified, contact your account team Express5800/320Ma: System Administrator s Guide

37 Chapter 3 ftserver Management Console3- For information about using ftserver Management Console (ftsmc), see the following topics: CPU and I/O Enclosures and Elements on page 3-1 ftsmc Overview on page 3-2 Running ftsmc on page 3-2 Performing ftsmc Tasks on page 3-6 For information about the Virtual Technician Module (VTM), see the Express5800/320Ma Virtual Technician Module User s Guide and ftsmc snapin help. CPU and I/O Enclosures and Elements Each system houses two CPU- I O enclosures. Each enclosure contains a CPU element and an I/O element joined to the same board. You can monitor each CPU element and I/O element separately. ftsmc represents these elements in the following nodes: CPU Enclosure - 0 and CPU Enclosure - 1 I/O Enclosure - 10 and I/O Enclosure - 11 Discussions of CPU enclosures and I/O enclosures apply equally to the correspinding parts of CPU- I O enclosures, unless otherwise specified. ftserver Management Console 3-1

38 ftsmc Overview ftsmc Overview ftsmc, an MMC snap-in, is the system management tool you use to monitor and control the operation of your system. ftsmc works with ftserver Manager (ftsm) to present a list of the system components in the console tree and properties of the component in the details pane. ftsm gathers information about the system hardware and software components. ftsmc presents the information that ftsm gathers. ftsm runs only on Express5800/320Ma systems. ftsmc runs on Express5800/320Ma systems and on systems running Windows 2000, Windows Server 2003, or Windows XP. Running ftsmc You can run ftsmc: NOTES 1. Use ftsmc to disable devices. Do not use Windows Device Manager to disable devices except in documented special situations. 2. MMC snap-ins, including ftsmc, do not lock edit sessions to prevent simultaneous users from editing the same parameters. Directly on Your Express5800/320Ma system On a remote computer From a remote computer by accessing your Express5800/320Ma system desktop remotely Running ftsmc Directly on Your Express5800/320Ma System Click the ftserver Management Tools shortcut on your system s desktop. Or, do the following: 1. Click the Start button, and then click Run. 2. Click Browse, navigate to C:\Program Files\Stratus\management, and then click ftserver.msc. 3. Click OK. 3-2 Express5800/320Ma: System Administrator s Guide

39 Running ftsmc Running ftsmc on a Remote Computer You can manage your system by running ftsmc on a remote system or on any system running Windows 2000, Windows Server 2003, or Windows XP. 1. Install ftsmc on a supported computer: Use the Remote Management Installation (RMI) procedure described in the Express5800/320Ma: Software Installation and Configuration Guide. 2. Add the ftsmc snap-in to MMC, specify a system to manage, and save the console that contains the snap-in. To manage systems you have added to a console, open a previously saved MMC console that contains ftsmc. Adding the ftserver Management Console Snap-in to MMC 1. From the Start menu of the remote computer, click Run, type mmc in the Open box, and click OK. 2. In MMC, click the Console menu item, and click Add/Remove Snap-in. 3. In the Add/Remove Snap-in dialog box, click Add. The Add Standalone Snap-in dialog box appears with a list of snap-ins. 4. Click ftserver Management Console and click Add. The Connect dialog box appears. 5. Type the servername.domainname or the IP address of the server (for example, usbos01.wtcus.com or ), and select or clear the Connect as current user check box. If you clear the check box, type the user name and password that will be used to make the connection. Click Finish. NOTES 1. The user name that you enter must be in the Windows Administrators group for the computer that you want to manage. 2. You can select any remote Express5800/320Ma 3.2 GHz, 3.6 GHz or Dual-Core system to manage, as long as you have appropriate access to it. 6. Click Close in the Add Standalone Snap-in dialog box. 7. Click OK in the Add/Remove Snap-in dialog box. The name of the system appears in MMC. The ftsmc snap-in displays information about the system and you can use the ftsmc snap-in to manage the system. ftserver Management Console 3-3

40 Running ftsmc 8. Save this console, with ftsmc added, for later use by clicking Save As in the Console menu. In the Save As dialog box, type a file name in the File Name box, and click Save. The ftsmc snap-in tree includes an ftserver Call Home Modem node (as shown in Figure 3-1), which presents the operational status of the call-home modem. Figure 3-1. ftsmc Tree Virtual Modems The two modems that appear in Windows Device Manager on your Express5800/320Ma system (see Figure 3-2) represent virtual modems that the VTMs use to communicate with the system.! CAUTION Do not use applications or devices that try to connect to any modem involved in communicating with the ASN, especially on systems that send alarms by phone only. 3-4 Express5800/320Ma: System Administrator s Guide

41 Running ftsmc Figure 3-2. Virtual Modems Using VTMs to Troubleshoot Systems Although you may dial in to the VTM to troubleshoot the system, be aware that call-home support and alarm transmission through the ASN modem will be blocked for the duration of the connection. However, if your system is configured to send alerts by the following options (see Determining the Value of the Send Alarms By Property on page 3-6), use of the ASN modem will not block alarms or call-home support, which continue over the Internet: Internet with phone line as backup Phone line with Internet as backup Internet only See the Express5800/320Ma ActiveService Network Configuration Guide for configuration information. ftserver Management Console 3-5

42 Performing ftsmc Tasks Determining the Value of the Send Alarms By Property 1. In ftsmc, expand ftserver (Local) and ftserver Configuration. 2. Click ActiveService Network. 3. In the details pane, check the value of the Send Alarms By property. Opening a Previously Saved MMC Console 1. Click Start, and then click Run. 2. In the Run window, type mmc in the Open box, and then click OK. 3. In the Console menu, click Open, and then click the name of the previously saved MMC console. 4. In the Connect dialog box, click Finish. Running ftsmc by Remote Access You can run ftsmc from a remote computer by accessing a target system s desktop from the remote computer. See Remote Access to Your System Desktop on page 2-5 for methods you can use to access the system s desktop remotely. Once you have accessed the system s desktop, perform the procedure described in Running ftsmc Directly on Your Express5800/320Ma System on page 3-2 to run ftsmc. Performing ftsmc Tasks Detailed instructions for using ftsmc are available in the online Help for ftsmc. Before interacting with ftsmc, observe the following cautions.! CAUTION Before using ftsmc to interact with the NEC Technical Support, perform the tasks described in the Express5800/320Ma ActiveService Network Configuration Guide.! CAUTION When working in ftsmc, generally do not change the configured values of properties unless directed to do so in documentation or by the NEC Technical Support. ftsmc Interface The details pane, the icons used in ftsmc, and the ftsmc display refresh options are features of the ftsmc interface. Figure 3-3 shows the ftsmc user interface. 3-6 Express5800/320Ma: System Administrator s Guide

43 Performing ftsmc Tasks To expand all nodes, press the asterisk (*) key on the number pad. Figure 3-3. ftsmc User Interface Table 3-1 describes the key elements in the ftsmc user interface. Table 3-1. ftsmc User Interface Key Elements Item Description Function 1 Action band The Action menu contains MMC snap-in commands. The View menu contains console viewing options. 2 Console tree Lists all system component nodes. Each node represents a manageable object. 3 Details pane Displays the properties related to the node selected in the console tree. For an explanation of a property, right-click the property and select What s this? from the shortcut menu. (Not all properties have What s this? help.) The Express5800/320Ma: Technical Reference Guide includes information about properties. 4 Status bar Displays ftsmc status messages. ftserver Management Console 3-7

44 Performing ftsmc Tasks Details Pane The names and values of the properties of the components in the ftsmc tree are displayed in the details pane. A question mark (?) icon in front of a property name indicates that What s this? Help is available. Right-click the property name and click in the shortcut menu that appears. See Figure 3-4. Figure 3-4. Details Pane 3-8 Express5800/320Ma: System Administrator s Guide

45 Performing ftsmc Tasks Icons Used in ftsmc Figure 3-5 shows and describes the icons used in the system inventory. Figure 3-5. System Inventory Icons A dimmed folder icon indicates that the node does not contain any information. It is empty. A plain, yellow folder icon indicates that the node is online and contains information or child nodes. This icon indicates online simplex components. A tools icon indicates that the node is offline, possibly for maintenance. A dual-monitor icon indicates that the node is duplexed (partnered) with another node (for example, two CPU elements). NOTE It is safe to remove a duplexed component. A magnifying glass icon indicates that the node is offline and undergoing diagnostic testing. A single-monitor icon indicates that the component is operating simplexed (unpartnered). NOTE It is unsafe to remove a simplexed component from the system. Removing a simplexed component causes loss of that component function to the system. The simplexed icon can also indicate an invalid configuration. For instance, the simplexed icon next to Ethernet Controller - 2, shown in Figure 3-6, indicates that Network Port - 0 and Network Port - 1 beneath the Ethernet Controller - 2 are duplexed, but that Ethernet Controller - 2 is simplexed, which makes it a single point of failure, an illegal configuration. ftserver Management Console 3-9

46 Performing ftsmc Tasks Figure 3-6. Simplexed Icon for Invalid Configuration ftsmc displays warning and error icons described in Table 3-2. Table 3-2. ftsmc Warning and Error Icons Icon Type Description Indication Warning Exclamation point inside a yellow triangle A node whose child node has an error. Error White X inside a red circle The node is offline, in testing, or has failed. No inventory found Threshold warning White X inside a gray circle Exclamation point inside a red triangle ftsmc cannot retrieve inventory information for that device. The ftsmc status bar displays a message indicating that the properties cannot be retrieved. The current reading of a sensor value exceeds the specified threshold. Parent nodes display the yellow warning icon. Figure 3-7 shows an error icon next to the Ethernet Adapter, indicating an error on that node. Warning icons precede the names of all parent nodes that have nodes with an error. Figure 3-7. Warning and Error Icons 3-10 Express5800/320Ma: System Administrator s Guide

47 Performing ftsmc Tasks Figure 3-8 shows a no inventory found icon next to the CPU Enclosure icons. Figure 3-8. Warning and Inventory Error Icons Figure 3-9 shows a threshold warning icon at the Voltage Sensor. Its parent nodes display the yellow warning icon. Figure 3-9. Threshold Warning Icon Refreshing the ftsmc Display You can right-click the ftserver (Local) root node to enable or disable each of three refresh options. These options cause ftsmc to refresh, or update, the information in the details pane when the specified event occurs. You should enable these options so that the details pane and the node icons update when you complete an action or when a state change occurs. When enabled, a check mark appears in front of the option, as shown in Figure ftserver Management Console 3-11

48 Performing ftsmc Tasks Figure ftsmc Details Pane Refresh Options Viewing and Changing Properties To view the properties of a system inventory component, click the component s node in the console tree. The names and values of that component s properties are displayed in the details pane, as shown in Figure 3-4. Some components properties are configurable. Components with configurable properties have a Properties command in their shortcut menu. See Figure See the ftsmc online help for details. Figure Properties Command in Shortcut Menu 3-12 Express5800/320Ma: System Administrator s Guide

49 Performing ftsmc Tasks Required Operational States for Commands Table 3-3 presents the operational state that a device must be in to carry out the associated command. Table 3-3. Operational State for Associated Commands Command Valid States CPU Element Initiate BringUp Initiate BringDown Initiate Diagnostics Set Priority Removed, Broken, Shot, Firmware update complete, Diagnostics passed. Broken, Firmware update complete, Diagnostics passed, Duplex. Removed, Broken, Firmware update complete, Diagnostics passed. CPU element must be online and duplexed. I/O Element Initiate BringUp Initiate BringDown Initiate Diagnostics Removed, Broken, Shot, Diagnostics passed. Broken, Diagnostics passed, Duplex. Removed, Broken, Diagnostics passed. ftserver Management Console 3-13

50 Performing ftsmc Tasks 3-14 Express5800/320Ma: System Administrator s Guide

51 Chapter 4 Disk Storage Management4- The following disk-management topics apply to your Express5800/320Ma system: Data Fault Tolerance on page 4-1 Guidelines for System Disks on page 4-2 Using RDR for Fault Tolerance on page 4-2 Using Volume Mirroring for Fault Tolerance on page 4-20 Mirroring Disks in Your Express5800/320Ma System on page 4-24 Finding a Physical Disk on page 4-25 Data Fault Tolerance Your Express5800/320Ma system offers two methods of ensuring data fault tolerance and continuous availability of its disk media: Rapid Disk Resync (RDR), a disk-replicating technology, is supported only on the internal disk drives. To create striped volumes across the mirrored internal disks, refer to the documentation for your disk-management tool. You choose to implement RDR, for internal disk drives, or volume-mirroring, for all disks, during the software installation and configuration procedure. However, you can upgrade your disks to RDR after software installation. Disk Storage Management 4-1

52 Guidelines for System Disks NOTE Create a backup of the system disk with which to restart the system in the unlikely event of a system failure. See the Express5800/320Ma: Software Installation and Configuration Guide. Guidelines for System Disks Observe the following guidelines when configuring the system disks. On the system disk, the IPL procedure creates a boot partition, which contains the operating system and all of its components. You can greatly reduce application downtime when you upgrade software by installing and using the optional Active Upgrade software. If you do plan to install and use Active Upgrade software, be sure to keep system files on a separate disk from data files. See the Express5800/320Ma: Active Upgrade User s Guide for more information. Using RDR for Fault Tolerance Use RDR disk mirroring to configure and create managed disks in the internal storage. With RDR disk mirroring, you can mirror pairs of physical disks to create RDR virtual disks. Each pair of mirrored disks constitutes one RDR virtual disk. RDR offers faster resynchronization of mirrored disks than other mirroring methods after transient failures or when a single disk is briefly removed from service. NOTE In RDR terminology, an individual physical disk is also called a plex, and an RDR virtual disk is also called a LUN, for logical unit. The data on one disk of the RDR virtual disk pair is replicated in full that is, mirrored or duplex on its corresponding partner disk, irrespective of volume or partition layout. However, an RDR virtual disk may also be simplex; that is, consisting of only one physical disk. A simplex RDR virtual disk may contain mirrored volumes created using third-party disk management facilities. If all volumes on a simplex RDR disk are mirrored with other disks in the system, then the simplex RDR disk is effectively duplex (mirrored). If you are upgrading a system s internal disks from a non-rdr to an RDR configuration, the existing internal disks must provide adequate space for metadata. Metadata is 4-2 Express5800/320Ma: System Administrator s Guide

53 Using RDR for Fault Tolerance data about data that the RDR software stores on disks to implement disk management. When you configure a disk for RDR, the system displays an error message if the disk does not have adequate space. The disk being upgraded should be a basic disk. Use RDR to mirror internal disks. To create large striped volumes, use your disk-management tool to create striped volumes across the mirrored internal disks. Automatic Virtual Disk Expansion An RDR virtual disk includes an automatic disk-capacity expansion feature. If you replace the physical disks (plexes) of an RDR virtual disk with larger physical disks, RDR automatically recognizes the resulting larger virtual disk, which enables the system to use the added disk capacity. Note, however, that a virtual disk cannot be larger than the smaller of its two physical disks. For example, if each physical disk of an RDR virtual disk is 80 gigabytes (GB), the virtual disk is an 80-GB virtual disk. If you replace one 80-GB physical disk with a 160-GB physical disk, the virtual disk remains an 80-GB disk, the smaller of the two physical disks. But if you replace the other 80-GB physical disk with another 160-GB physical disk, the RDR virtual disk automatically updates to 160 GB. Disk Storage Management 4-3

54 Using RDR for Fault Tolerance ftsmc reports the capacity of physical disks and virtual disks in the Capacity property in two different locations: The physical disk Capacity property appears in the ftsmc details pane under I/O Enclosure - 10, Storage Enclosure - 40, Slot - n, Disk - n. The virtual disk Capacity property appears in the ftsmc details pane under Logical Disk Information, RDR Virtual Disk - n. The virtual disk value is slightly lower than the physical disk value because the virtual disk value is reduced by the space reserved for metadata. NOTE Automatic virtual disk expansion does not work on dynamic virtual disks; that is, RDR virtual disks that have been converted to dynamic disks by Windows Disk Management Managing RDR Disks Managing RDR-configured disks can include any of the following tasks: Using RDR to mirror disks in internal storage Enabling write caching and read-load balancing Setting the active RDR disk (plex) Deleting RDR configuration on a physical disk Removing a physical disk from and RDR virtual disk Deporting a physical disk from an RDR virtual disk Creating a Spare Bootable RDR Disk Breaking a Physical Disk from an RDR Virtual Disk Converting disks from dynamic to basic Setting or clearing the mean-time between failure (MTBF) threshold Resynchronizing a physical disk from the RDR virtual disk Setting the MTBF faultcount limit Making a backup of a boot disk Booting with a backup disk 4-4 Express5800/320Ma: System Administrator s Guide

55 Using RDR for Fault Tolerance Reusing dynamic disks Recovering a disk Verifying disk integrity Prioritizing resynchronization To use RDR to mirror dynamic disks, see the Express5800/320Ma: Software Installation and Configuration Guide. You can also set disk parameters from the SCSI Port Duplex Driver - Sradisk_Driver node shortcut menu in the ftsmc. Notes on Using RDR to Mirror Disks in Internal Storage The procedure used to mirror disks with RDR is the same used to upgrade a disk to RDR. If you are upgrading disks to use RDR, be sure that the disks are basic disks. If the disks have been configured as dynamic disks, convert the disks to basic disks before upgrading them to RDR. Although you can only create RDR disks from basic disks, you can make RDR disks dynamic if your policies require it. If you insert a non-rdr-configured disk into a slot whose partner slot is occupied by an RDR virtual disk, the system automatically adds the inserted disk to the RDR virtual disk. Not all RDR commands and procedures are valid on all physical disks. Error messages appear if you attempt an invalid RDR command. Error messages also suggest possible corrective actions, where applicable. Some RDR configuration changes, especially those made on simplex RDR virtual disks, may require the operating system to restart, in order to complete. When the Windows restart warning appears, you can restart the system immediately or defer restart until a more convenient time. An RDR disk is brought online as Unconfigured if you insert it into a slot whose companion slot contains an RDR configured disk that is not the inserted disk s partner. An RDR disk is brought online normally if you insert it into a slot whose companion slot either is empty or contains an unconfigured disk. Disk Failures during Resynchronization In RDR resynchronization, the partnered RDR virtual disks relate as source and target disks. The source is the disk from which the target disk is being resynchronized. If a source disk fails or is removed from service during resynchronization, the target disk is removed from the system and treated as a deported disk. If the target disk fails Disk Storage Management 4-5

56 Using RDR for Fault Tolerance or is removed from service during resynchronization, the source disk continues operating in simplex mode. If the system starts to shut down while an RDR virtual disk is resynchronizing, RDR records the state of the resynchronization and, upon system reboot, resumes resynchronization from that point. Write Caching To optimize system performance, you can enable write caching on RDR virtual disks. By default, write caching is disabled, except during disk resynchronization, when it is automatically enabled. Write caching does not work on a simplex RDR virtual disk (except when it is resynchronizing), even if it is enabled. However, if you enable write caching on a simplex disk that is later duplexed, write caching will work. To enable write caching 1. Right-click My Computer on the desktop, select Manage, select Device Manager, and then expand Disk Drives. 2. Select the target disk, select Properties, and click the Policies tab. 3. Check Enable write caching on the disk, and click OK. Read-load Balancing When you enable read-load balancing, read operations on duplex RDR virtual disks alternate between the two physical disks, which improves performance. By default, read-load balancing is enabled on all RDR physical disks. You can enable or disable read-load balancing either for each physical disk or globally, for all RDR physical disks across the system. To enable or disable read-load balancing for a single physical disk 1. In ftsmc, expand ftserver I/O Enclosures and Logical Disk Information. 2. Right-click the target RDR Virtual Disk. 3. Select Set Rdr Lun Load Balancing. 4. In the dialog box, set the Rdr Lun Load Balancing field to On or Off, and click Finish. NOTE Global read-load balancing settings do not overwrite read-load balancing settings on individual RDR physical disks. 4-6 Express5800/320Ma: System Administrator s Guide

57 Using RDR for Fault Tolerance To enable or disable read-load balancing globally 1. In ftsmc, expand ftserver Drivers, right-click SCSI Port Duplex Driver - Sradisk_Driver, and select Properties. 2. On the dialog box, click the right-most Properties tab. 3. In the GlobalRdrPlexLoadBalancing field, select On or Off, and click OK. NOTE Global settings do not overwrite settings made on individual RDR physical disks. To add a physical disk to an RDR virtual disk 1. Insert and latch disks (see Figure 4-1) into corresponding slots in the enclosures. (See Finding a Physical Disk on page 4-25 for an explanation of the numeric values in the figures.) In your Express5800/320Ma system, the internal storage disks are numbered from top to bottom in a rack-mounted system. See Table 4-1 and Figure 4-1. Table 4-1. RDR Disk Numbering ftsmc Console Pane Node Storage Enclosure - 40 ftsmc Details Pane ObjectName Property Location in System Slot-1, Disk-0 Harddisk0 Bottom disk drive Slot-2, Disk-1 Harddisk1 Middle disk drive Slot-3, Disk-2 Harddisk2 Top disk drive Logical Disk Information RDR Virtual Disk 1 Harddisk0 Bottom disk drive RDR Virtual Disk 2 Harddisk1 Middle disk drive RDR Virtual Disk 3 Harddisk2 Top disk drive Disk Storage Management 4-7

58 Using RDR for Fault Tolerance Figure 4-1. Mirroring RDR Virtual Disks I/O Element 10 Slot Number: 3 Device ID: 10/40/3/2 RDR virtual disk 3 Slot Number: 2 Device ID: 10/40/2/1 RDR virtual disk 2 Slot Number: 1 Device ID: 10/40/1/0 RDR virtual disk 1 I/O Element 11 Slot Number: 3 Device ID: 11/40/3/2 RDR virtual disk 3 Slot Number: 2 Device ID: 11/40/2/1 RDR virtual disk 2 Slot Number: 1 Device ID: 11/40/1/0 RDR virtual disk 1 sysad003a 2. Double-click ftserver Management Tools on the Windows desktop to start ftsmc. 3. In ftsmc, select the target disk in I/O element 10. For example, expand ftserver I/O Enclosures, I/O Enclosure - 10, Storage Enclosure - 40, Slot - 1, and then click Disk Right-click the target disk, and click Add Physical Disk To RDR Virtual Disk. 4-8 Express5800/320Ma: System Administrator s Guide

59 Using RDR for Fault Tolerance NOTE If you receive an error message when using the Add Physical Disk To RDR Virtual Disk command, the disk you are trying to add may not have sufficient free space for the metadata. Be sure the disk has a minimum of 10MB free space. A System Shutdown message may appear, stating that the system will reboot in two minutes. If the message appears, let the system restart. NOTES 1. If you have added a system disk to an RDR virtual disk, a message notifies you that the system will reboot. The message gives you the option of confirming or cancelling the request. The system also restarts if you add a data disk to an RDR virtual disk and the software cannot unmount all data volumes on the disk. 2. You cannot add a physical disk to RDR if the disk is dynamic or a nonblank data disk. 5. In the Device Configuration Change dialog box, click Yes. 6. Repeat steps 3 5 for the corresponding disk in I/O element 11. For example, expand ftserver I/O Enclosures, I/O Enclosure - 11, Storage Enclosure - 40, Slot - 1, and then click Disk Allow time for the two disks to synchronize. While the disks are resynchronizing, LEDs blink to indicate read and write operations and ftsmc displays a value of OpState: State Syncing in the details pane for the disk. To view the progress of the synchronization in ftsmc, expand Logical Disk Information under ftserver I/O Enclosures, and select the virtual disk (for example, RDR Virtual Disk 1). In the details pane, the progress is noted as a percentage, as follows: Status: Resync: 20 percent When the disks are synchronized, the LEDs on both disks are lit steady green and ftsmc displays a value of OpState: State: Duplex in the details pane for the disk and for the virtual disk. The value next to Status for the virtual disk is None. Disk Storage Management 4-9

60 Using RDR for Fault Tolerance 8. For each additional virtual disk to be created, repeat steps 3 7, mirroring: The disk in slot 2 of I/O element 10 with the disk in slot 2 of I/O element 11 to create virtual disk 2 The disk in slot 3 of I/O element 10 with the disk in slot 3 of I/O element 11 to create virtual disk 3 Mirroring Dynamic Disks with RDR This procedure turns dynamic disks into basic disks before mirroring them with RDR. To use RDR to mirror dynamic disks themselves, see Chapter 3 in the Express5800/320Ma: Software Installation and Configuration Guide. Mirroring a dynamic disk with RDR involves two steps: Converting the disk to basic Upgrading the disk to RDR Converting a Dynamic Disk to a Basic Disk! CAUTION Converting a dynamic disk to a basic disk removes all data from the disk. So that you can recover the data, back it up to backup media before you convert the disk to a basic disk. 1. Right-click My Computer, and click Manage. 2. Expand Computer Management and Storage. 3. Click Disk Management. 4. Right-click the icon of the target disk in the lower portion of the Disk Management details pane. 5. Select Convert to Basic Disk. 6. If necessary, recover the information from backup media. To upgrade the basic disks to RDR, see Notes on Using RDR to Mirror Disks in Internal Storage on page 4-5. Setting the Active RDR Disk (Plex) The Set As Active RDR Plex command makes the physical disk on which this command is issued the "active" disk. The active disk is the disk: From which data is read From which a partner disk is resynchronized 4-10 Express5800/320Ma: System Administrator s Guide

61 Using RDR for Fault Tolerance That survives a failover (the failure of one of two, duplex components) To which the data traffic goes when disk utilities, like chkdsk, are run You might use Set As Active RDR Plex, for example, when using the chkdsk command to check the performance of a particular physical disk in an RDR virtual disk. To do this, issue the Set As Active RDR Plex command for the physical disk you want to check; this makes it the active disk. Then disable read-load balancing on the RDR virtual disk, and run chkdsk on the active disk. In the following procedure, n indicates a component number that appears in ftsmc. 1. In ftsmc, expand I/O Enclosure - 10 (or 11), Storage Enclosure, Slot - n, and then right-click on Disk - n. 2. Select Set As Active RDR Plex. A message reports that the operation was successful. Deleting the RDR Configuration on a Physical Disk Deleting the RDR configuration removes a physical disk from the RDR virtual disk. You delete one physical disk at a time. After you delete the RDR configuration on a physical disk: The RDR metadata is deleted, but other data remains on the disk. The disk is no longer an RDR disk and is not part of an RDR virtual disk. You can reconfigure the disk as an RDR disk again, using the Add Physical Disk To RDR Virtual Disk command. You can delete the RDR configuration only from basic data disks, not from dynamic disks, boot disks, or data disks with one or more paging files. To delete the RDR configuration on a physical disk 1. In ftsmc, right-click the target disk. 2. Select Delete RDR Configuration on Physical Disk for disk 0 (or 1 or 2). 3. Optionally, repeat steps 1 and 2 on the disk with which the deleted disk was mirrored. When the second of the mirrored disks is removed from the RDR virtual disk, the RDR virtual disk is removed. 4. If desired, repeat steps 1 3 for each physical disk to be removed. Disk Storage Management 4-11

62 Using RDR for Fault Tolerance NOTE Disregard any Unsafe Removal of Device messages that appear when you remove an internal physical disk from the enclosure. Removing a Physical Disk from an RDR Virtual Disk! CAUTION Removing a physical disk from an RDR virtual disk deletes all of the data from the target disk. Executing the Remove a Physical Disk from RDR Virtual Disk command on a partnered (duplex) RDR virtual disk (comprising two physical disks): Erases all of the data on the disk, including all Windows Disk Management, and all RDR metadata. Returns the physical disk to a basic, non-rdr-configured, blank disk. The system does not warn you when you issue this command because the target disk has a surviving partner physical disk that still contains all of the data. For that reason, the system does not need to restart. If you execute the Remove a Physical Disk from RDR Virtual Disk command on an unpartnered (simplex) RDR virtual disk (comprising one physical disk), the system prompts you to remove all partition and volume data on the disk before the command can continue. The prompt alerts you that this operation may result in the loss of all data on this virtual disk since there is only one physical disk. You cannot remove: The only unmirrored boot disk The only unmirrored disk containing a paging file An unmirrored disk containing data A resynchronizing disk To remove a physical disk from an RDR virtual disk 1. In ftsmc, right-click the target disk. 2. Select Remove Physical Disk from RDR Virtual Disk Express5800/320Ma: System Administrator s Guide

63 Using RDR for Fault Tolerance Deporting a Physical Disk from an RDR Virtual Disk Deporting a physical disk from an RDR virtual disk makes the deported disk a clone of its RDR virtual disk partner. You use the Deport Physical Disk from RDR Virtual Disk command to create backup disks and spare, bootable, RDR virtual disks. Once a disk is deported, it is hidden from the system and is inaccessible from ftsmc. It does not become accessible again until it is removed from and reinserted into the system. You can physically remove and then reinsert the disk, or you can issue the InitiateBringdown and InitiateBringup commands for the disk slot. If you insert a disk deported from one system into another system, the disk appears in ftsmc as Active, Configured, Deported. A deported disk inadvertently left in the system or reinserted into its original slot remains an intact backup. It is not automatically resynchronized or overwritten by the primary RDR virtual disk. You cannot deport: The last physical disk of an RDR virtual disk if it is bootable or contains a paging file An unmirrored boot disk A dynamic disk A resynchronizing disk The Deport a Physical Disk from an RDR Virtual Disk command should be grayed out if the physical disk is not in the valid state (for example, if it is a dynamic disk or a simplex boot disk) for this command to work properly. A valid deport operation should rarely fail. If the Deport a Physical Disk from an RDR Virtual Disk operation requires that the system reboot, a system-restart dialog box appears, giving you the option to restart the system immediately or later. If the operation succeeds without requiring a reboot, a message box indicating success appears. If Deport a Physical Disk from an RDR Virtual Disk fails, a dialog box indicating the reason for the failure appears. In this case, the RDR virtual disk is not deported and the system does not reboot. After a successful Deport a Physical Disk from an RDR Virtual Disk command, no drive letters or mount points associated with volumes on the deported disk are preserved. To deport a physical disk from an RDR virtual disk 1. In ftsmc, right-click the target disk. 2. Select Deport Physical Disk from RDR Virtual Disk. Disk Storage Management 4-13

64 Using RDR for Fault Tolerance A message reports that you may have to reboot the system if you continue with this command. You must restart only if the deport command fails. If it succeeds, a message reports the successful operation. 3. Click OK. A message appears, telling you to remove the deported disk. 4. Remove the deported disk. The deported disk disappears from ftsmc. Creating a Spare Bootable RDR Disk 1. Be sure that the system (boot) disk is mirrored. 2. Deport the disk that is the mirror of the system disk. 3. Physically remove the deported disk from the system. Label and store this disk, which is now the spare bootable hard disk, in a safe place.! CAUTION If the original boot disk is still in a system into which you insert a spare (deported) boot disk, the original boot disk loses its RDR configuration and is no longer an RDR-enabled disk. For more details, see the discussion of creating a spare bootable disk in the Express5800/320Ma: Software Installation and Configuration Guide. Breaking a Physical Disk from an RDR Virtual Disk The following procedure isolates an RDR virtual disk plex for backup, backs up the volumes, and then resynchronizes the broken plex with its original partner, adding it back to the RDR virtual disk. You cannot perform this procedure on: dynamic disks simplex RDR virtual disks RDR virtual disks while they are resynchronizing RDR virtual disks if their verify interval is set to 0; that is, if RDR verify is disabled Express5800/320Ma: System Administrator s Guide

65 Using RDR for Fault Tolerance 1. Verify the RDR virtual disk that you are going to backup to ensure that both plexes of the RDR virtual disk are healthy. 2. In ftsmc, expand I/O Enclosure, Storage Enclosure, and then select Slot 1, 2, or 3 to access Disk 0, 1, or Right click on the target disk and select Break Physical Disk from RDR Virtual Disk. This command splits the plex from the RDR virtual disk, creates an exact copy of its volumes, and adds them to Disk Management. 4. Use backup software to make a copy of these volumes created in Disk Management; then remove the volumes from Disk Management. 5. To add the removed plex back to the RDR virtual disk, in ftsmc, right-click the disk you broke in step 2, and select Add Physical Disk to RDR Virtual Disk. The plex is now synchronized with its active partner and is again a partner in an RDR virtual disk. Setting or Clearing the MTBF for Disks Clearing the MTBF resets the MTBF to infinity, the number of faults to 0, and the time of last fault to never. Setting the MTBF Threshold sets the MTBF threshold and views the current count (seconds), number of faults, and date and time of last fault. NEC Solutions (America), Inc. presets the MTBF threshold; you should not change it unless instructed to do so by your support representative. See MTBF Statistics on page 5-1 for an explanation of MTBF. To set or clear the MTBF for disks 1. In ftsmc, right-click the target disk. 2. Select either Set MTBF Threshold or Clear MTBF. If you select Set MTBF Threshold, specify the desired threshold value in the Threshold field of the dialog box that appears, and then click Finish. A message appears, indicating a successful operation. If you select Clear MTBF, the MTBF is cleared and a message appears, indicating a successful operation. Setting the MTBF Faultcount Limit for Disks The MTBF faultcount limit defines the number of times certain errors can occur before the system sends threshold events that generate alarms. Disk Storage Management 4-15

66 Using RDR for Fault Tolerance! CAUTION Do not change the MTBF faultcount limit value, except when advised to by NEC Technical Support. 1. In ftsmc, right-click the target disk. 2. Select Set MTBF Faultcount Limit. 3. In the dialog box, enter the desired limit value and click Finish. A message appears, indicating a successful operation. Booting a System with a Backup RDR Boot Disk 1. Remove power from the system. 2. Remove all boot disks from the internal storage enclosure, if any are installed. 3. Insert the backup boot disk. 4. Press the system power button. Reusing Data Disks If you have stored a copy of a data disk that was created with RDR disk mirroring, use the following procedures to reuse the disk in the system. Reusing a Stored-Data Disk After you perform this procedure: The data on the stored-data disk is overwritten with the data on the disk in its companion slot. The stored-data disk remains an RDR disk. To reuse a stored-data disk 1. Make sure the original partner of the stored disk is in the companion slot. 2. Insert the stored disk into its original slot. The system automatically resynchronizes the stored disk with the partner disk. Wait for the disk to be fully resynchronized before removing the stored disk or before removing power from the system. Removing the RDR Configuration from a Stored-Data Disk This procedure removes the RDR configuration from a stored-data disk and deletes all of its data Express5800/320Ma: System Administrator s Guide

67 Using RDR for Fault Tolerance NOTE To delete the RDR configuration from a stored-data disk but retains its data, see Deleting the RDR Configuration on a Physical Disk on page Make sure no disk occupies the slot that is the partner slot to the disk whose RDR configuration you are removing. 2. If your disk was a dynamic disk, use your disk-management tool to convert the disk to basic, deleting all data on the disk. If your disk was a basic disk, use your disk-management tool to delete all volumes and partitions. 3. In ftsmc, select and right-click the disk, and click Remove Physical Disk From RDR Virtual Disk.! CAUTION You must complete the final step. Otherwise, if the former RDR virtual disk partner of the newly erased disk is inserted into the partner slot of the erased (but not deleted) disk, the newly inserted disk is mirrored to the empty disk, deleting the data on the newly inserted disk. Resynchronizing RDR Disks The system automatically resynchronizes disks that are reinserted into the system and when I/O elements are returned to service. You can also issue a command to resynchronize a disk with its partner from the ftsmc. When RDR disks are resynchronizing, the Logical to Physical Mapping details pane shows the disk that is resynchronizing as SYNCING, and shows the partner disk as SIMPLEX. NOTE If you insert a blank disk into the companion slot of an RDR virtual disk, the blank disk is automatically configured and synchronized to the existing RDR disk. To resynchronize RDR data disks 1. In ftsmc, under the Logical Disk Information icon, right-click the target RDR virtual disk; that is, the disk that might not be synchronized with its mirror disk. Disk Storage Management 4-17

68 Using RDR for Fault Tolerance 2. Select Resynchronize This Physical Disk From RDR Virtual Disk. A message appears, indicating a successful start of the command. See step 7 in Read-load Balancing on page 4-7 for a description of how to verify completion of the resynchronization process. See Disk Failures during Resynchronization on page 4-5 for instructions on what to do if the source RDR virtual disk fails during resynchronization. Resynchronizing a Backup Boot RDR Disk 1. Verify that the original partner disk of the backup boot disk is inserted into its original slot in the storage enclosure. 2. Reinsert the backup boot disk into its original slot in the storage enclosure. The backup boot disk automatically resynchronizes with the original partner. The command takes some time to run. See step 7 in Read-load Balancing on page 4-7 for a description of how to verify completion of the resynchronization process. Recovering and Replacing RDR Disks In your disk-management tool, if the status of an RDR disk appears as Offline, Missing, or Online (Errors), you can try to recover the disk manually. Verify that the disk is securely seated in the enclosure and that it has power. Perform the following procedures to recover the disk. To recover an RDR disk 1. Delete the RDR configuration on the disk, and then physically remove it from the enclosure. NOTE Disregard any Unsafe Removal of Device messages that appear when you remove an internal physical disk from the enclosure. 2. Replace the defective disk and add the disk to an RDR virtual disk. In the unlikely event of a system failure resulting from disk failures, restore the system by performing one of the following procedures, as appropriate: Restore the system by using a backup system disk. See the discussion of creating spare bootable hard disks in the Express5800/320Ma: Software Installation and Configuration Guide for information. Reload the Express5800/320Ma System software, as described in the Express5800/320Ma: Software Installation and Configuration Guide Express5800/320Ma: System Administrator s Guide

69 Using RDR for Fault Tolerance To replace a failed physical RDR disk 1. Remove the failed disk. 2. Insert a blank replacement disk. Verifying RDR Disks RDR disk verification verifies the integrity of RDR disk mirrors. Specifically, it: 1. Reads all sectors on both disks. If it detects a read error, it recovers the degraded sector from the good partner disk. This safeguards the integrity of both disks. 2. Compares the data from each sector on both disks. If it detects a discrepancy, it logs an error to the event log. In the unlikely event that this happens, contact NEC Technical Support or your authorized service representative, or log an issue under their maintenance contract. To verify an RDR disk 1. In ftsmc, expand ftserver I/O Enclosures and click Logical Disk Information. 2. Right-click the appropriate RDR virtual disk. 3. Select Verify RDR Virtual Disk. A message appears, stating that the operation completed successfully, meaning that the command has been executed. To stop verifying an RDR disk Use the following procedure to stop RDR verification. 1. In ftsmc, expand ftserver I/O Enclosures and click Logical Disk Information. 2. Right-click the appropriate RDR virtual disk. 3. Select Stop Verify RDR Virtual Disk. A message appears, stating that the operation completed successfully, meaning that the command has been executed. To set the interval for automatic RDR disk verification 1. In ftsmc, expand ftserver Drivers, right-click SCSI Port Duplex Driver - Sradisk_Driver, and select Properties. 2. In the dialog box, click the third Properties tab from the left. 3. Set the LunVerifyInterval property to the desired value and click OK. The default value is minutes (7 days), meaning minutes from the time of the last verification command. The nonzero minimum value cannot be less than 60 minutes. A value of 0 disables automatic RDR disk verification. Disk Storage Management 4-19

70 Using Volume Mirroring for Fault Tolerance Configuring the Priority of RDR Virtual Disk Resynchronization The resynchronization priority establishes the portion, expressed in megabytes per second (Mbps) in the details pane, of I/O bandwidth that is used for the RDR disk resynchronization operation. To prioritize resynchronization for all RDR disks in the system 1. In ftsmc, expand ftserver Drivers, right-click SCSI Port Duplex Driver - Sradisk_Driver, and select Properties. 2. In the dialog box, click the third Properties tab from the left. 3. Set GlobalResyncPriority to Low, Normal, or High and click OK. To prioritize resynchronization for individual RDR disks 1. In ftsmc, expand the appropriate I/O Enclosure node and click Logical Disk Information. 2. Right-click the target RDR virtual disk. 3. Select Set Resync Priority. 4. Select Low, Medium, or Normal and click OK. Using Volume Mirroring for Fault Tolerance When using Windows Disk Management to implement data fault tolerance, format volumes as NTFS volumes. Configure disks as dynamic disks. Dynamic disks organize data within volumes on a disk and support fault-tolerant operation and disk migration between systems. Mirror each volume (the boot volume on the system disk and all data volumes) on two or more physical disks. See Mirroring Disks in Your Express5800/320Ma System on page 4-24 for details. Assign system disks and data disks to the same disk group.! CAUTION Failure to set up your disk storage as required results in storage that is not fault tolerant. System disk usage topics include mirroring disks, mirror resynchronization, and information about inserting more than one disk at time. A mirror is an identical copy of data that you can access if your primary data becomes unavailable. NEC Solutions (America), Inc. requires that you mirror the boot volume on the system disk. The resulting mirrored pair of disks work together to provide a 4-20 Express5800/320Ma: System Administrator s Guide

71 Using Volume Mirroring for Fault Tolerance fault-tolerant volume. If one disk fails, the volume automatically uses the data from the other disk. Mirror all data volumes. Mirroring volumes as documented provides fault tolerance, because volumes are mirrored on separate physical disks on separate FC buses. When mirroring volumes, pair identical physical disks (same capacity, model, and manufacturer) so that in the event of a disk failure, an entire physical disk can be replaced without any data loss. See Mirroring Disks in Your Express5800/320Ma System on page 4-24 for details. Mirrored Volume Resynchronization When a volume is mirrored across two physical disks, and one of the disks fails or is brought offline for any reason, the remaining good disk continues to operate. However, the data on the mirrored volumes is no longer synchronized. After a disk is replaced or brought back online, the mirror between it and the disk that remained in operation must be resynchronized. During resynchronization, the system copies the format and the contents of the good mirrored volume(s) to their mirror(s) on the disk most recently brought back online. NOTE Because mirror resynchronization can severely affect performance, you should resynchronize mirrors when the system is least busy. Mirror resynchronization can occur automatically, or, in some cases, you must resynchronize the mirror manually: If you insert a replacement disk without a disk signature into the same slot as the failed disk, the system automatically attempts to resynchronize the disk. If you replace a failed disk with a blank basic or dynamic disk that contains a signature, you must resynchronize the disks manually. The system automatically attempts to resynchronize the disks if: An I/O element is removed and inserted. An I/O element goes offline and returns online. Volume Resynchronization After Rebooting After rebooting the system, and depending on the circumstances under which the system was shut down, you may need to explicitly reactivate a failed mirrored partner to resynchronize a volume. Disk Storage Management 4-21

72 ftsmc Interface for Storage Enclosures and Subsystems For example, if the system was shut down normally, but it was shut down while synchronization was in progress, you need to explicitly reactivate the mirror. On the other hand, if the system shutdown was due to an unexpected event like a power failure, the disks begin the remirroring process automatically after booting. NOTE Before mirroring system disks with a disk management tool (such as Windows Disk Management, make sure either that both disks are plexes of an RDR virtual disk or that neither disk is. Do not partner RDR and non-rdr system disks in a mirror. Otherwise, the disks will fully resynchronize after every reboot. The boot disks do not require resynchronization if the RDR disk is the primary boot volume from which the system is booted. Inserting or Removing More Than One Disk at a Time You may remove disks from or insert disks into the internal storage as needed. ftsmc Interface for Storage Enclosures and Subsystems The Storage Enclosure node represents the internal storage subsystem and the EMC attached storage systems are not directly represented in ftsmc. The Fibre Channel Controller node represents the adapter associated with an attached EMC storage subsystem Express5800/320Ma: System Administrator s Guide

73 ftsmc Interface for Storage Enclosures and Subsystems Storage Enclosure Node The Storage Enclosure node contains some or all of the following nodes: Slot Disk Sensors Module Slot Node The Slot node represents the slots where disks reside. System disks must reside in certain slots (see Mirroring Disks in Your Express5800/320Ma System on page 4-24 for details). NOTE In ftsmc, the storage Slot nodes display the Start Slot Identification and Stop Slot Identification commands. Although these commands appear in the context menu for slots in internal storage, the driver for those slots does not support them. Disk Node Each Disk node represents a hard disk that resides in a slot in a storage enclosure. You use the DevicePathID property to locate a physical disk. See Finding a Physical Disk on page 4-25 for details. Sensor Nodes The Sensor Node include the following subnodes: Temperature sensors monitor the ambient temperature within the enclosures. Fan Speed sensors monitor the rotational speed of the fans within the enclosures. Voltage sensors monitor the voltage level of power within the enclosures.! CAUTION NEC Solutions (America), Inc. presets the configurable threshold property values of these sensors. Do not change them unless instructed to do so by the NEC Technical Support. Disk Storage Management 4-23

74 Mirroring Disks in Your Express5800/320Ma System EMC Attached Storage If an optional EMC CLARiiON, EMC Symmetrix, or EMC CLARiiON AX100 Storage System is installed in your system, Fibre Channel Controller nodes will appear beneath the PCI Slot Info nodes in which the adapters are installed. NOTE System disks cannot reside in an EMC attached storage system. See Mirroring Disks in Your Express5800/320Ma System on page 4-24 for details. The values that the Op State: State and Op State: Reason properties can take vary depending on whether EMC PowerPath software is running. See Table 4-2 for details. Table 4-2. FC Host Bus Adapter State and Reason Property Values With PowerPath software running Without PowerPath software running Op State: State Simplex Duplex Broken Broken Online Broken Op State: Reason None None Media Disconnect None None Media Disconnect When you reattach a cable between your EMC storage system and the PCI adapters in your system, the connection state may not be immediately reflected in ftsmc. To update ftsmc, issue the command powermnt restore in PowerPath, from Run on the Start menu, or from a command prompt. The information in ftsmc should be updated after about 15 seconds. Mirroring Disks in Your Express5800/320Ma System Your Express5800/320Ma system supports the following storage systems: Internal SATA disk drives EMC storage systems The various disk-mirroring schemes are outlined in the following sections. See EMC documentation for information about EMC disk-mirroring configurations Express5800/320Ma: System Administrator s Guide

75 Finding a Physical Disk Mirroring Disks in Internal Storage Your Express5800/320Ma system internal storage supports only SATA disks. Its disks are located in a disk tray that connects to the system backplane. For non-rdr disk-mirroring configurations, mirror the volumes on disks in two separate disk trays. For RDR disk mirroring, mirror the internal storage disks as shown in Figure 4-1. Only internal storage enclosures support RDR disks. NOTES 1. The system disk and its mirrored partner must both reside in the same storage location. 2. The system disk and its mirrored partner are located in slot 1 of each enclosure. See Finding a Physical Disk on page 4-25 for details about physically locating a volume s hard drive. Configuring and Creating RDR Disks You can mirror disks in system internal storage enclosures as RDR disks. Figure 4-1 shows how disks are mirrored in your Express5800/320Ma system. The arrows in the figures indicate the required mirroring scheme. Finding a Physical Disk You find the location of internal physical disks by using the ftsmc. You find disks located in external storage using both Windows Disk Management and ftsmc. You can use the Logical to Physical Mapping node in ftsmc to physically locate the disk members of RDR virtual disks, or the non-rdr disk on which a particular volume resides. Finding an Internal Physical Disk System internal disks are identified in the Logical to Physical Mapping node details pane. The information differs somewhat for RDR and non-rdr disks. To use the Logical to Physical Mapping node 1. In ftsmc, expand ftserver I/O Enclosures and then Logical Disk Information. 2. Click Logical to Physical Mapping. Disk Storage Management 4-25

76 Finding a Physical Disk For RDR virtual disks, the detail pane presents information in the following format:the Harddisk0-LUN1-PLEX2 (Basic) 11/40/1 (DUPLEX) Harddisk0-LUN1-PLEX1 (Basic) 10/40/1 (DUPLEX) information for non-rdr disks is the same, except that it does not include LUN (RDR virtual disk) or PLEX (physical disk) information, which pertains only to RDR disks. In the details pane: Harddisk0 refers to the Windows disk name. LUN1 refers to RDR virtual disk 1. (Your Express5800/320Ma system can support a maximum of three RDR virtual disks: LUN 1, LUN 2, and LUN 3.) PLEX1 and PLEX2 refer to the two physical disks that together make up RDR virtual disk 1 (LUN 1). Basic refers to type of disk. The other possible value is Dynamic. 10/40/1 indicates the following: 10 indicates I/O element 10. NOTE In rack-mounted systems, I/O element 10 is in the top enclosure and I/O element 11 is in the bottom enclosure. Pedestal systems (not available in Express5800/320Ma Dual-Core systems) are rotated 90 degrees clockwise, so that I/O element 11 is on the left side (from the front) of the system and I/O element 10 is on the right side. 40 indicates the internal storage enclosure within the I/O element. 1 indicates the bottom disk slot in rack-mounted systems. For RDR disks, Duplex indicates that the two physical disks of the RDR virtual disks are partnered. If the two physical disks were not partnered, the displayed value would be Simplex. For non-rdr disks, the values in this position indicate the disk s operating status. RDR virtual disks list DevicePath[1] and DevicePath[2] properties that indicate the device ID of the disks that make up the virtual disk. However, the DevicePathID for an RDR virtual disk does not indicate a hardware component, but instead identifies the virtual disk to system-management software Express5800/320Ma: System Administrator s Guide

77 Finding a Physical Disk Finding an External Physical Disk For disks in external storage systems, the operating system assigns letter designations to the logical volumes on the physical disks. Windows Disk Management assigns a disk name to each physical disk in an external storage system and displays which logical volumes reside on each named disk. For a particular volume, you can use the disk name in conjunction with ftsmc to identify the location of the physical disk that contains that volume. NOTE The disks of EMC storage systems do not appear in ftsmc. To find a volume s physical disk 1. In the Windows Disk Management tool (accessed from My Computer), find the disk name that contains the volume in question. These disk names may or may not be numeric; however, they do not correspond to disk locations. Volume information is displayed along with the disk name. 2. Note the disk name that contains the volume you want to physically locate; for example, Disk In ftsmc, expand Storage Enclosures, then Logical Disk Information, and then click Logical to Physical Mapping. 4. In the Name column of the ftsmc details pane, find the disk name you noted in step 2. Look up its corresponding device path ID in the Value column. This identifies the physical location of the disk within the system. (See Device IDs and Device Paths on page 5-6 for details.) For example, Disk 3 may have the disk name Harddisk3 in ftsmc and have a device path ID of 70/12/3. This disk would appear in ftsmc under the Storage Enclosures node as Disk 3 in Slot 12 of Storage Enclosure Use the device path ID determined in step 4 with the labels on the system to identify the disk location. You can also use Diagrams of Component Locations on page 5-8 to help locate the disk. NOTE When external disks are resynchronizing, the Logical to Physical Mapping details pane shows the disk that is resynchronizing as SIMPLEX and includes the percentage of the disk that has resynchronized: for example, SIMPLEX (%20). Disk Storage Management 4-27

78 Finding a Physical Disk 4-28 Express5800/320Ma: System Administrator s Guide

79 Chapter 5 Troubleshooting5- The following topics can help you troubleshoot your Express5800/320Ma system: MTBF Statistics on page 5-1 Taking Components Offline and Bringing Them Online on page 5-2 Hard Disks on page 5-2 Determining That a Component Has Failed on page 5-5 Locating Components on page 5-6 When Windows Does Not Respond on page 5-9 Delayed System Restart on page 5-9 Unresponsive Mouse and Keyboard on page 5-10 Remote Event Notification and Service on page 5-10 Making Dump Files on page 5-11 Online Diagnostic Codes on page 5-13 Disaster Recovery on page 5-14 MTBF Statistics The fault-tolerant services software automatically maintains mean-time-between-failure (MTBF) statistics for many system components. Administrators can view this information in ftsmc at any time and can reconfigure the MTBF parameters that affect how the fault-tolerant services respond to component problems. The system stores the current MTBF values associated with each device in Windows registry keys. Whenever any of the MTBF values change, the registry reflects the change. Therefore, when the driver stops and restarts, or the system restarts, the system retains the current MTBF information. For procedures explaining how to set these settings, see the online ftsmc snap-in help. Troubleshooting 5-1

80 Taking Components Offline and Bringing Them Online Clearing the MTBF Clearing the MTBF sets the MTBF to 0 (Unknown) and erases the record of all faults. NOTE Clearing the MTBF does not bring a device back into service automatically. If the device that you cleared is in the Broken state, you must correct the state. Changing the MTBF Threshold The MTBF threshold is expressed in seconds. If a device s MTBF falls beneath this threshold, the system takes the device out of service and changes the device state to Broken.! CAUTION NEC Solutions (America), Inc. presets the MTBF thresholds. You should not modify them unless instructed to do so by NEC Technical Support or your authorized service representative. Taking Components Offline and Bringing Them Online You can use ftsmc to take a component offline or bring a component online. Before you take a component offline, verify that it is safe to do so. For a description of the procedures, see the online help for ftsmc. Hard Disks If a disk s status is not healthy, you may be able to recover the disk, or you may need to replace the disk. Recovering a Disk In your disk-management tool, try to recover the disk manually if: A failed volume (non-rdr only) appears as Failed Redundancy The RDR or non-rdr disks appear as Offline, Missing, or Online (Errors) 5-2 Express5800/320Ma: System Administrator s Guide

81 Hard Disks Verify that the system does not have a problem that is causing the mirror to break on an internal or external disk. Ensure that the disk is securely seated in the drive and that it has power. Perform the following procedures to recover the disk. To recover an RDR disk 1. Logically and then physically remove the physical disk from the RDR virtual disk. NOTE Disregard any Unsafe Removal of Device messages that appear when you remove an internal physical disk from the enclosure. 2. Replace the defective disk and make the disk an RDR disk. In the unlikely event of a system failure resulting from disk failures, restore the system by performing one of the following procedures, as appropriate: Restore the system by using a backup system disk. See the discussion of creating spare bootable hard disks in the Express5800/320Ma: Software Installation and Configuration Guide for information. Reload Express5800/320Ma System software, as described in the Express5800/320Ma: Software Installation and Configuration Guide. To recover a disk in Windows Disk Management 1. Go to Windows Disk Management in Computer Management. 2. Right-click the disk icon corresponding to the disk that has the Offline, Missing, or Online (Errors) status, and in the option menu, click Reactivate Disk. 3. After the mirror regenerates (this may take several minutes), verify that the status of the disk has returned to Healthy.! CAUTION If a disk continues to have the status of Online (Errors), replace it as soon as possible. If the recovery procedures fail to reactivate the disk, or if the status does not return to Healthy, you must physically replace the failed disk. Replacing a Failed Disk in Windows Disk Management You can replace a failed disk with an uninitialized disk (a disk that has no signature written on it). This is the quickest and easiest option. If your only spare disk is initialized (it has a signature written on it), you can replace the failed disk with an initialized disk. Troubleshooting 5-3

82 Hard Disks Replacing a Failed Disk with an Uninitialized Disk Follow this procedure to replace a failed disk with an uninitialized disk. To physically locate a disk, see Finding a Physical Disk on page To replace a failed disk with an uninitialized disk 1. Physically remove the failed disk and replace it with an uninitialized disk. 2. Disk-management software automatically resynchronizes the replacement disk with the remaining good disk, creating volumes on the replacement disk and mirroring the disks. Replacing a Failed Disk with an Initialized Disk Perform the following procedure to replace a failed disk with an initialized disk using Windows Disk Management. To physically locate a disk, see Finding a Physical Disk on page To use Windows Disk Management to replace a failed disk with an initialized disk 1. Physically remove the failed disk and replace it with an initialized disk. For details, see the operation and maintenance guide for your system. 2. Examine the type of the initialized replacement disk: If the replacement disk s type is Foreign Dynamic, go to step 3. If the replacement disk s type is Basic, go to step In Disk Management, right-click the foreign dynamic replacement disk, and then click Convert to Basic. The replacement disk should now appear as a basic disk. 4. If the basic replacement disk has any volumes, delete them. Right-click the volume on the replacement disk, and then click Delete Partition. Repeat for each volume on the replacement disk. Verify that the basic replacement disk now appears as a single unallocated space. 5. Right-click the replacement disk and click Convert to Dynamic. 6. Remove the mirrors from the missing disk that was physically removed in step 1. Right-click a volume on the missing disk and then click Remove Mirror. In the Remove Mirror dialog box, select the missing disk and click the Remove Mirror button.! CAUTION Be sure to select the missing disk, not the remaining good disk. You will lose data if you select the remaining good disk. Repeat this step for each volume on the missing disk. 5-4 Express5800/320Ma: System Administrator s Guide

83 Determining That a Component Has Failed 7. Right-click the missing disk, and then click Remove Disk. 8. On the remaining good disk, right-click a volume and click Add Mirror. In the Add Mirror dialog box, select the replacement disk and click the Add Mirror button. Repeat this step for all other volumes on the remaining good disk. Hardware Installation Wizard Occasionally, after a system reboot or after hot-plugging an I/O element or a disk, a hardware-installation wizard may appear, indicating that a Express5800/320Ma disk device has been found. Continue through the wizard steps, but click Cancel at the end rather than rebooting. Determining That a Component Has Failed Component LEDs and ftsmc provide indicators that a component has failed. See the operation and maintenance guide for your system for general troubleshooting information related to system hardware. ftsmc indicates a failed component by showing a white X inside a red box next to the icon of a failed component. Using LEDs to Troubleshoot Hardware LEDs, where present, indicate the status of components. The LEDs can help you locate a failing or failed component. The LED status is also shown by ftsmc in the details pane of components that have LEDs. The LED State properties indicate the state of an LED in the system. On your Express5800/320Ma system, the LEDs are green, amber, and white. For detailed information about LEDs and particular components, see the operation and maintenance guide for your system. Using ftsmc to Troubleshoot Hardware You can view component icons in ftsmc to see if a component has failed. To use ftsmc to determine that a component has failed 1. In ftsmc, expand the System Inventory by clicking the ftserver node in the console tree and pressing the asterisk (*) key on the numeric keypad. 2. Look for Warning (an exclamation point inside a yellow triangle) or Error (a white X inside a red circle) icons. If you see a Warning icon, click the plus sign (+) in front of nodes that have a Warning icon until you see an Error icon. For example, in Figure 5-1, Warning icons appear in three nodes, and the Error icon appears beside the slot that has a problem. Troubleshooting 5-5

84 Locating Components Figure 5-1. Warning and Error Icons 3. Click the problem node and check the MTBF: Current value in the details pane. If it is less than the MTBF: Threshold value, that node has failed and the system removes it from service. For example: MTBF: Time of Last Fault May 30, :07:24 MTBF: Threshold 300 seconds MTBF: Number of Faults 2 MTBF: Current 220 second Locating Components ftsmc displays device IDs and device paths for system components that it monitors. Components that have a dual-initiated bus have dual device paths. Component location diagrams show the device IDs of major elements, enclosures, and internal disks. Two commands assist you in locating select system components: Start Slot Identification. Causes the LEDs on the component to flash so that you can physically locate it. Stop Slot Identification. Stops the LEDs on the component from flashing after you have physically located it. Disk slots on CPU- I O enclosure slots, PCI adapter slots, and modems support these slot identification commands. Device IDs and Device Paths Hardware components in the system inventory are organized hierarchically. Level 1 components (for example, CPU elements and I/O elements, represented by the CPU Enclosure nodes and I/O Enclosure nodes, respectively) have Level 2 child components, such as DIMMs and processors, which may have Level 3 and Level 4 components. For example, I/O enclosures (elements), which are Level 1, have storage enclosures (Level 2), which have slots (Level 3), which have disks (Level 4). Hardware devices in the system inventory have device ID numbers. For example, the device ID of the I/O element in Figure 5-2 is 11. Figure 5-2 illustrates the following hierarchically presented components and their device IDs: 5-6 Express5800/320Ma: System Administrator s Guide

85 Locating Components Level 1: I/O Enclosure - 11 Level 2: Mass Storage Controller - 0 and SATA Controller - 1 Level 3: Ports 0 through 2 Figure 5-2. Component Levels A device path is a slash-separated sequence of device IDs that identifies the location of a component in the system. Device paths appear in the details pane of ftsmc. They use the following syntax: Level-1 device ID/Level-2 device ID/Level-3 device ID/Level-4 device ID For example, referring to Figure 5-2, the device path 11/1/2 indicates: I/O Enclosure - 11/SATA Controller - 1/Port - 2 Table 5-1 presents the system device IDs. Table 5-1. System Devices and Device IDs Component Level Device Device ID 1 Call-Home Modem CPU Enclosure (element) I/O Enclosure (element) 0 0, 1 10, 11 Troubleshooting 5-7

86 Locating Components Table 5-1. System Devices and Device IDs Component Level Device Device ID 2 DIMM Processor Storage Enclosure (internal) BMC Mass Storage Controller SATA Controller USB Controller VGA Controller VTM Adapter Ethernet Controller PCI to PCI Bridge First PCI-X slot on riser card PCI Slot Info 3 Port Network Port Slot , , Disk (internal) 0 2 Device IDs and device paths apply only to hardware components. Logical devices (for example, two physical Ethernet ports partnered to provide a single fault-tolerant path to the network) and software components do not have device IDs even if they appear in the ftsmc interface. Diagrams of Component Locations See Figure 5-3 to locate I/O and CPU elements for your Express5800/320Ma system. If a component is shown as failed or failing in ftsmc, note its device ID and then use the following information to locate that component within the system. All top-level components have a physical label that includes their device ID. System Elements and Internal Storage Disk Locations Figure 5-3 shows the locations of the CPU and I/O elements and disk slots. The internal storage is housed in an enclosure located above the CPU- I Oenclosure. 5-8 Express5800/320Ma: System Administrator s Guide

87 When Windows Does Not Respond Figure 5-3. CPU-I/O Enclosure, and Disk Slot Labeling Slot 3 Slot 2 Slot 1 Slot 3 Slot 2 Slot 1 Top CPU 0 I/O 10 CPU 1 I/O 11 Bottom When Windows Does Not Respond If Windows does not respond (that is, if the system appears hung), use the VTM console or the power button (for systems without VTM console) to restart the system. Related information can be found in the Express5800/320Ma Virtual Technician Module User s Guide. Delayed System Restart When you restart a system that contains certain models of adapters, the system appears to hang for approximately 10 seconds while the drivers for the adapter are installed. Allow several seconds for restart to proceed. Troubleshooting 5-9

88 Unresponsive Mouse and Keyboard Unresponsive Mouse and Keyboard If your system contains VTMs, the mouse and keyboard may appear unresponsive at some point after the system has restarted. This is normal behavior while the operating system finds the virtual mouse and keyboard as new hardware. Responsiveness returns after a short period of time. Remote Event Notification and Service The ASN provides the following features: Event reporting to your NEC Technical Support or your authorized service representative (dial-out) Remote service to your system by service support personnel (dial-in) You use the ASM Web site to configure all remote event reporting and remote service features of the ASN. See the Express5800/320Ma ActiveService Network Configuration Guide for details. Remote Reporting of Events When the system s fault-tolerant software detects a hardware or software problem, the system generates alarm messages that can be: Sent to NEC Technical Support or other authorized service representative Sent to a customer contact by way of or pager Written to the Windows system event log Autonomous Call Home For systems with VTMs, the VTM can send an alarm when a fault-resilient boot fails to bring up the Windows operating system. System Inventory Reports An alarm message can include a full system inventory, a partial system inventory, or no inventory at all, depending on the message type. A system inventory consists of an enumeration of all of the properties of the manageable hardware devices tracked by the Inventory Service. SNMP Traps Most alarms can also generate SNMP traps. Device state alarms generate an SNMP trap whenever a device state transitions to or from an online, broken, or offline state. Sensor threshold alarms generate an SNMP trap whenever a sensor status improves or worsens to normal, warning, and critical states Express5800/320Ma: System Administrator s Guide

89 Making Dump Files Event-Log Entries ftserver Manager may generate an alarm in response to a sequence of several events. To indicate what these events are, an alarm message may include event-log entries. These event-log entries contain items that represent an event from both the System and Application event logs. The number of event-log entries included with an alarm message is determined by specifying how many seconds of the event log to include. ftserver Manager may configure this time differently for each type of alarm, or it may exclude some event-log entries. Remote Service If you have a service contract with NEC Technical Support or your authorized service representative, to connect to your system, your service representative first dials the system. For systems with VTMs, the adapter validates that the call is from a permitted source, disconnects the incoming call, and calls back to make a connection to the validated NEC Technical Support. For systems without VTMs, the Windows RAS service authenticates the call and allows NEC Technical Support user to log on. NOTE Do not change the SMM ASN Hub ID, SMM ASN Hub Password, Dial-in User Name, Dial-in Password, or PPP Password properties without first contacting NEC Technical Support or your authorized service representative. You can configure the system to allow the NEC Technical Support to connect to your system, either through a dialup modem or over the Internet, to diagnose problems and perform data-transfer functions. These accesses are subject to validation by NEC Technical Support database, by the VTMs on your system, and by you as the system administrator. NEC Technical Support or your authorized service representative may contact you to determine the seriousness of the condition. If a CRU has failed, the NEC Technical Support will ship a new part to your site. On systems equipped with VTMs, ftserver Manager continuously copies a limited number of Windows system event-log messages to a log on VTMs so that support personnel can retrieve the log if your system fails. Making Dump Files Dump files are snapshots of either a system s memory or a particular component s firmware memory. Dump files enable NEC Technical Support to diagnose system or component problems. You can create dump files in the following ways. Troubleshooting 5-11

90 Making Dump Files To create system memory dumps, you can: Press a button. Configure your system to create memory dumps. In ftsmc, right-click a CPU Enclosure, and select the Dump and Go command. In ftsmc, right-click a certain component, and select either the Dump and Go command or the Dump command. (These commands are not available for all components.) The Dump command dumps a snapshot of the corresponding component. While dumping, the component is not available. When the dump is complete, the component returns to service. You can also use Windows commands to configure the creation of memory dumps. See Windows documentation. Using the Dump Button! CAUTION Making a dump file of an entire system automatically takes the operating system offline and then restarts it. With a firm, fine-tipped object, like a pushpin, press the Dump button, which is actually a small circular opening. Press the Dump button on the primary enclosure. The primary enclosure is the enclosure on which the power switch LED is lit. The Dump button is located at the center rear panel of each enclosure. It is labeled DUMP. System Memory Dumps Memory dumps are enabled through the Board Instance driver s DumpQuickEnabled and DumpNumberOfFilesToSave properties. To enable system memory dumps 1. In ftsmc, expand ftserver (Local), ftserver Drivers, and then Board Instance Driver - srabid. 2. Right click Board Instance Driver - srabid, Properties, and set DumpQuickEnabled to True. 3. Set DumpNumberOfFilesToSave to the number of dump files you want to save to disk Express5800/320Ma: System Administrator s Guide

91 Online Diagnostic Codes Dump files beyond this number overwrite the existing saved dump files. For instance, if the value is 3, then the fourth saved dump file overwrites the first, existing dump file. If, at the time of a system crash, the DumpQuickEnabled property of the Board Instance Driver node is True and the CPU element is duplex, the system creates a memory dump and stores the dump in the memory of one CPU element. The system restarts with the remaining CPU element. After the system restarts, the dump is automatically copied to a disk file. After a system reboot where a dump has been generated, do not attempt to read or copy the Memory.dmp file created. After the system has completed writing the Memory.dmp file, it renames the file Memoryn.dmp, where n is a numeral. You can read or copy the Memoryn.dmp file. It may take up to five minutes after the reboot to complete writing the Memory.dmp file before it is renamed and can be read.! CAUTION If you attempt to read or copy the Memory.dmp file while the system is writing it, you may corrupt the file. The normal Windows dump mechanism is used if the DumpQuickEnabled parameter is False (disabled) or if the CPU element is in simplex mode. Dump and Go The Dump and Go command captures a snapshot dump of a running system or a particular component without significantly interfering with the system s or component s operation. The system must be running duplex in order to use this method. To capture a snapshot dump, right-click the CPU Enclosure node of interest in the ftsmc console tree and select Dump and Go from the Action menu. The system: Takes the selected CPU element offline with its memory intact Dumps a snapshot of the memory to C:\sradumps\Memoryn.dmp Displays the status of the operation Returns the CPU element back to online status A Dump and Go command on a BMC controller dumps a snapshot of the BMC firmware s memory, and then restores the BMC to service. Online Diagnostic Codes The Virtual BMC LCD displays online diagnostic codes (described in Appendix B) only when a diagnostic test is running on an operative system. Troubleshooting 5-13

92 Disaster Recovery Disaster Recovery Safe Mode To help you to log on and access system resources after a computer disaster has occurred, you can restart the system in safe mode, boot from a spare disk, or use the Windows WinPE command shell. You use the Safe Mode startup options to start the system with only the minimal necessary services. Safe Mode options include Last Known Good Configuration, Safe Mode, Safe Mode with Networking, and Safe Mode with Command Prompt. For more information, see Safe Mode startup options in Windows Help.! CAUTION You must disable the Watchdog Timer by disabling boot monitoring in the BIOS before attempting to boot in Safe Mode. See the Express5800/320Ma: Software Installation and Configuration Guide for a description of how to disable boot monitoring. Booting From a Spare System Disk To boot from a spare system hard disk, you need a spare hard disk that was prepared during your initial system configuration process. Refer to the Express5800/320Ma: Software Installation and Configuration Guide for information about how to prepare this hard disk. Typically, you boot from a backup hard disk only to recover from an unlikely disaster situation where all redundant system disks suffered simultaneous failure. To boot a system from an RDR boot disk, see Booting a System with a Backup RDR Boot Disk on page The following procedure explains how to boot a system from a non-rdr system disk. To boot from a previously prepared non-rdr spare system disk 1. Shut down the operating system. 2. Physically remove one of the original system disks. 3. Insert the spare system disk into the empty slot created in step Unlatch the other original system disk. 5. Power up the system. 6. After the system has booted, insert (latch) the original disk that you unlatched in step Express5800/320Ma: System Administrator s Guide

93 Disaster Recovery WinPE 7. Use your disk-management tool s Delete Volume command to delete the volume on the original disk you inserted in step 6. When this step is complete, the disk is set to Unallocated space. 8. Create a mirror of the spare system disk s C: volume on the original disk you inserted in step 6. Using Windows Disk Management, right-click the spare system disk s C: volume. In the shortcut menu, click Add Mirror. A wizard prompts you through the rest of the mirroring process. 9. When the disk is 100% resynchronized, verify that the original system disk and the upgraded system disk are healthy, resynching, dynamic, mirrored volumes. Note that the drives are not duplexed until the resynchronization activity is complete. 10. After all resynchronization activity has finished, verify that all dynamic disks are healthy, dynamic, mirrored volumes. 11. Start all applications to verify that your system and applications are working properly. WinPE (Windows Pre-Installation Environment) provides a command shell from which you can perform system recovery using operating system commands. To access the WinPE command shell, you must boot from the ExpressBuilder CD (1 of 2). Select the Use WinPE to repair a corrupted hard drive command when the Express5800/320Ma System software presents that option. WinPE is recommended for advanced users or administrators only. See Microsoft documentation for information about WinPE. Windows Hotfixes Distributed by NEC Solutions (America), Inc. To create a file that lists the Windows hotfixes distributed with your Express5800/320Ma System software release and installed on your system by an IPL or upgrade to the release, use the following procedure. To obtain a list of Windows hotfixes 1. Insert your ExpressBuilder CD (1 of 2) in the CD-ROM drive. 2. If the Express5800/320Ma System software installation wizard runs automatically and asks if you want to install Express5800/320Ma System Software, click Cancel. 3. In a command-prompt window, change to a directory in which to save the file. 4. Enter a command in the following format: dir cddrive:\bin\hotfix\*lg* > outputfile Troubleshooting 5-15

94 Disaster Recovery In the command format: cddrive is the drive letter for your CD-ROM drive LG is the language code for your Windows version outputfile is the name of the file to hold the results. You can specify any name for the file. 5. Eject the CD-ROM. For example, the following command produces a file named hotfixlist.txt in the current directory of your command prompt window. The file contains a list of all hotfixes for the English versions of Windows Server 2003: dir D:\Bin\Hotfix\*EN* > hotfixlist.txt 5-16 Express5800/320Ma: System Administrator s Guide

95 Appendix A Advanced TopicsA- This appendix presents the following advanced topics: Disabling Hyperthreading Using Windows Headless Mode and Console Redirection Security Configuration Wizard These procedures require that you change settings in the BIOS. For further information about BIOS settings, see the Express5800/320Ma: Technical Reference Guide. Disabling Hyperthreading Some system installations may disable hyperthreading to facilitate application execution.! CAUTION Disable hyperthreading only if your system satisfies the minimum BIOS version requirements. Contact NEC Technical Support or your authorized service representative to confirm that you have the correct BIOS version. To disable hyperthreading, you enter the ftserver Setup utility. To disable hyperthreading 1. Turn on or restart your system. When the logo screen appears, press F2 to enter your system s BIOS setup utility. The BIOS setup utility s Main menu appears after the system completes more of the POST (power-on self-test) process. 2. On the Main menu, use the right-arrow key to select the Advanced tab. 3. Use the down-arrow key to select Advanced Processor Options and press Enter. 4. Select Hyper Threading Technology and press Enter. 5. Change the value from Enabled to Disabled and press Enter. Advanced Topics A-1

96 Using Windows Headless Mode and Console Redirection 6. Press Esc, then select Exit Saving Changes and press Enter. The system resumes booting. Using Windows Headless Mode and Console Redirection In headless mode, Windows Server 2003 can run without a keyboard, mouse, and monitor. You can remotely manage and restart the system through a serial connection. If your system is operating in headless mode, and if the port for both console redirection and Windows headless are set to use the same Serial port, configure the BIOS to stop console redirection when the power-on self-test (POST) has finished processing. To configure the BIOS to stop console redirection after POST 1. When the system is booting and the progress bar has started to fill, press F2 to enter the BIOS setup program and wait for the BIOS setup program to run. 2. Use the RIGHT ARROW key to select the Advanced tab. 3. On the Advanced menu, use the DOWN ARROW key to select Console Redirection. Press ENTER. 4. On the Console Redirection menu, use the DOWN ARROW key to select Continue C.R. after POST. Use the PLUS SIGN key (+) to change the value to OFF. 5. Press F In the Setup Confirmation dialog box, select Yes and press ENTER to save the new settings and exit from the BIOS Setup program. Security Configuration Wizard If you use the Security Configuration Wizard (new in Windows Server 2003 Service Pack 1) to create a security-configuration template on an Express5800/320Ma system, perform the following steps to ensure that the template does not interfere with ftserver services running on the system. The following steps assume that you have selected all the defaults associated with the ftserver services. NOTE The dialog boxes shown in the following steps do not appear in the exact sequence shown. However, they should all appear in the course of running the Security A-2 Express5800/320Ma: System Administrator s Guide

97 Security Configuration Wizard Configuration Wizard. See Windows documentation for more information. 1. Check the Remote access client box in the Select Client Features dialog box, as shown below. 2. In the Open Ports and Approve Application dialog (shown below), if the ftserver SSN service (SRA_SSN.EXE) does not appear in the list, click Add. Advanced Topics A-3

98 Security Configuration Wizard 3. Browse to the location of the SRA_SSN.EXE service, as shown in the dialog box below, and click OK. The service name then appears checked in the list shown in the step 2. A-4 Express5800/320Ma: System Administrator s Guide

99 Security Configuration Wizard 4. In the Open Ports and Approve Application dialog box (shown in step 2), click Add, select SRA_RAS.EXE, and press OK. The service name then appears checked in the list shown in the step 2. Advanced Topics A-5

Express5800/320Ma: Virtual Technician Module User s Guide

Express5800/320Ma: Virtual Technician Module User s Guide Express5800/320Ma: Virtual Technician Module User s Guide NEC Solutions (America), Inc. NR561 Notice The information contained in this document is subject to change without notice. UNLESS EXPRESSLY SET

More information

ftserver 5600 to ftserver 6600 Upgrade Procedure 3/22/04

ftserver 5600 to ftserver 6600 Upgrade Procedure 3/22/04 ftserver 5600 to ftserver 6600 Upgrade Procedure 3/22/04 Notice The information contained in this document is subject to change without notice. UNLESS EXPRESSLY SET FORTH IN A WRITTEN AGREEMENT SIGNED

More information

Stratus ftserver 2600, 4500, and 6300 Systems: Operation and Maintenance Guide

Stratus ftserver 2600, 4500, and 6300 Systems: Operation and Maintenance Guide Stratus ftserver 2600, 4500, and 6300 Systems: Operation and Maintenance Guide Stratus Technologies R639-01A Notice The information contained in this document is subject to change without notice. UNLESS

More information

Quick Setup & Getting Started

Quick Setup & Getting Started Quick Setup & Getting Started HP Compaq Business PC Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and

More information

BCM 4.0 Personal Call Manager User Guide. BCM 4.0 Business Communications Manager

BCM 4.0 Personal Call Manager User Guide. BCM 4.0 Business Communications Manager BCM 4.0 Personal Call Manager User Guide BCM 4.0 Business Communications Manager Document Status: Beta Document Version: 02 Part Code: N0027256 Date: January 2006 Copyright Nortel Networks Limited 2006

More information

Dell PowerVault DL Backup to Disk Appliance and. Storage Provisioning Option

Dell PowerVault DL Backup to Disk Appliance and. Storage Provisioning Option Dell PowerVault DL Backup to Disk Appliance and the Symantec Backup Exec Storage Provisioning Option The software described in this book is furnished under a license agreement and may be used only in accordance

More information

Getting Started. HP Business PCs

Getting Started. HP Business PCs Getting Started HP Business PCs Copyright 2010, 2012-2014, 2016 HP Development Company, L.P. Windows is a registered trademark or trademark of Microsoft Corporation in the United States and/or other countries.

More information

Express5800/320La System Release Notes

Express5800/320La System Release Notes System Release Notes Express5800/320La System Release Notes PN: 455-01623-003 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

ftserver 6600 Upgrade Procedure 3/11/04

ftserver 6600 Upgrade Procedure 3/11/04 ftserver 6600 Upgrade Procedure 3/11/04 1 Notice The information contained in this document is subject to change without notice. UNLESS EXPRESSLY SET FORTH IN A WRITTEN AGREEMENT SIGNED BY ANAUTHORIZEDREPRESENTATIVE

More information

EXPRESSBUILDER 3.005b-G Update Notes

EXPRESSBUILDER 3.005b-G Update Notes Express5800/320Lb Software Notes EXPRESSBUILDER 3.005b-G Update Notes Express5800/320Lb EXPRESSBUILDER 3.005b-G Update Notes Page 1 of 9 Proprietary Notice and Liability Disclaimer The information disclosed

More information

EXPRESS5800/320Lb/320Lb-R EXPRESSBUILDER

EXPRESS5800/320Lb/320Lb-R EXPRESSBUILDER EXPRESS5800/320Lb/320Lb-R EXPRESSBUILDER () User s Guide Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials, is the valuable

More information

Veritas System Recovery 18 Management Solution Administrator's Guide

Veritas System Recovery 18 Management Solution Administrator's Guide Veritas System Recovery 18 Management Solution Administrator's Guide Documentation version: 18 Legal Notice Copyright 2018 Veritas Technologies LLC. All rights reserved. Veritas and the Veritas Logo are

More information

PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000. User Manual. Version 1.3

PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000. User Manual. Version 1.3 PROMISE ARRAY MANAGEMENT ( PAM) FOR FastTrak S150 TX2plus, S150 TX4 and TX4000 User Manual Version 1.3 Promise Array Management Copyright 2003 Promise Technology, Inc. All Rights Reserved. Copyright by

More information

Getting Started. HP Business PCs

Getting Started. HP Business PCs Getting Started HP Business PCs Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Windows is a U.S. registered trademark of

More information

Online Help StruxureWare Data Center Expert

Online Help StruxureWare Data Center Expert Online Help StruxureWare Data Center Expert Version 7.2.7 What's New in StruxureWare Data Center Expert 7.2.x Learn more about the new features available in the StruxureWare Data Center Expert 7.2.x release.

More information

Getting Started. HP Business PCs

Getting Started. HP Business PCs Getting Started HP Business PCs Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, Windows Vista, and Windows

More information

ThinkSystem SR650 Messages and Codes Reference

ThinkSystem SR650 Messages and Codes Reference ThinkSystem SR650 Messages and Codes Reference Machine Types: 7X05 and 7X06 Note Before using this information and the product it supports, be sure to read and understand the safety information and the

More information

Avalanche Remote Control User Guide. Version 4.1

Avalanche Remote Control User Guide. Version 4.1 Avalanche Remote Control User Guide Version 4.1 ii Copyright 2012 by Wavelink Corporation. All rights reserved. Wavelink Corporation 10808 South River Front Parkway, Suite 200 South Jordan, Utah 84095

More information

IBM FlashSystem 720 & FlashSystem 820 Remote Support Overview

IBM FlashSystem 720 & FlashSystem 820 Remote Support Overview IBM FlashSystem 720 & FlashSystem 820 Remote Support Overview Copyright IBM Corporation 2014 i Applicable Products Product: IBM FlashSystem 720 Product Version(s): 6.3.1-p10, 6.3.0 Product: IBM FlashSystem

More information

About Your Software IBM

About Your Software IBM About Your Software About Your Software Note Before using this information and the product it supports, be sure to read Appendix. Viewing the license agreement on page 19 and Notices on page 21. First

More information

About Your Software Windows NT Workstation 4.0 Windows 98 Windows 95 Applications and Support Software

About Your Software Windows NT Workstation 4.0 Windows 98 Windows 95 Applications and Support Software IBM Personal Computer About Your Software Windows NT Workstation 4.0 Windows 98 Windows 95 Applications and Support Software IBM Personal Computer About Your Software Windows NT Workstation 4.0 Windows

More information

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL Copyright 2002, Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced or transmitted

More information

RAID Controller Installation Guide

RAID Controller Installation Guide RAID Controller Installation Guide Document Number 60001075 Second Edition March 2003 The RAID Controller Installation Guide explains how to install and configure a RAID Controller in an Omvia Media Server.

More information

IBM Personal Computer. About Your Software Windows NT Workstation 4.0, Applications, and Support Software

IBM Personal Computer. About Your Software Windows NT Workstation 4.0, Applications, and Support Software IBM Personal Computer About Your Software Windows NT Workstation 4.0, Applications, and Support Software IBM Personal Computer About Your Software Windows NT Workstation 4.0, Applications, and Support

More information

Host Upgrade Utility User Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine

Host Upgrade Utility User Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute Engine Host Upgrade Utility User Guide for Cisco UCS E-Series Servers and the Cisco UCS E-Series Network Compute First Published: August 09, 2013 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive

More information

Stratus Automated Uptime Layer for VMware vsphere -based ftserver Systems: Installation and Configuration

Stratus Automated Uptime Layer for VMware vsphere -based ftserver Systems: Installation and Configuration Stratus Automated Uptime Layer for VMware vsphere -based ftserver Systems: Installation and Configuration Stratus Technologies R004E-03 Notice The information contained in this document is subject to change

More information

FASTTRAK TX4000 QUICK START GUIDE. Version 1.2

FASTTRAK TX4000 QUICK START GUIDE. Version 1.2 FASTTRAK TX4000 QUICK START GUIDE Version 1.2 FastTrak TX4000 Copyright 2002 Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced

More information

Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E

Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E Sidewinder Hardware Guide Models S1104, S2008, S3008 Revision E Table of contents Preface...3 Find product documentation... 3 1 Introducing the appliances... 4 Models and features... 4 Supported software...

More information

Serial ATA PCI RAID Quick Installation Guide

Serial ATA PCI RAID Quick Installation Guide Serial ATA PCI RAID Quick Installation Guide Introducing the Serial ATA PCI RAID The Serial ATA PCI RAID is an ultra high-speed two channel Serial ATA controller board for use in Pentium-class computers.

More information

AlterPath KVM/net Plus Installation, Configuration, and User s Guide

AlterPath KVM/net Plus Installation, Configuration, and User s Guide AlterPath KVM/net Plus Installation, Configuration, and User s Guide Software Version 2.0 Cyclades Corporation 3541 Gateway Boulevard Fremont, CA 94538 USA 1.888.CYCLADES (292.5233) 1.510.771.6100 1.510.771.6200

More information

Virtual Appliance User s Guide

Virtual Appliance User s Guide Cast Iron Integration Appliance Virtual Appliance User s Guide Version 4.5 July 2009 Cast Iron Virtual Appliance User s Guide Version 4.5 July 2009 Copyright 2009 Cast Iron Systems. All rights reserved.

More information

Veritas System Recovery 16 Management Solution Administrator's Guide

Veritas System Recovery 16 Management Solution Administrator's Guide Veritas System Recovery 16 Management Solution Administrator's Guide Documentation version: 2017 Legal Notice Copyright 2017 Veritas Technologies LLC. All rights reserved. Veritas and the Veritas Logo

More information

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide

HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide HP ProLiant Agentless Management Pack (v 3.2) for Microsoft System Center User Guide Abstract This guide provides information on using the HP ProLiant Agentless Management Pack for System Center version

More information

Nortel Quality Monitoring. Maintenance Guide NN

Nortel Quality Monitoring. Maintenance Guide NN NN44480-504 Document status: Standard Document version: 0102 Document date: 6 November 2009 All Rights Reserved While the information in this document is believed to be accurate and reliable, except as

More information

Installing the IBM ServeRAID Cluster Solution

Installing the IBM ServeRAID Cluster Solution Installing the IBM ServeRAID Cluster Solution For IBM Netfinity ServeRAID-4x Ultra160 SCSI Controllers Copyright IBM Corp. 2000 1 2 IBM Netfinity Installing the IBM ServeRAID Cluster Solution Chapter 1.

More information

Quick Setup & Getting Started Business PCs

Quick Setup & Getting Started Business PCs Quick Setup & Getting Started Business PCs Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows

More information

Videoscape Distribution Suite Software Installation Guide

Videoscape Distribution Suite Software Installation Guide First Published: August 06, 2012 Last Modified: September 03, 2012 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800

More information

RemoteWare OS/2 Client

RemoteWare OS/2 Client RemoteWare OS/2 Client User s Guide Version 4.1 Service Pack 1A RemoteWare OS/2 Client User s Guide Version 4.1 Service Pack 1A This document was prepared to assist licensed users of RemoteWare by XcelleNet,

More information

Installation Guide. EventTracker Enterprise. Install Guide Centre Park Drive Publication Date: Aug 03, U.S. Toll Free:

Installation Guide. EventTracker Enterprise. Install Guide Centre Park Drive Publication Date: Aug 03, U.S. Toll Free: EventTracker Enterprise Install Guide 8815 Centre Park Drive Publication Date: Aug 03, 2010 Columbia MD 21045 U.S. Toll Free: 877.333.1433 Abstract The purpose of this document is to help users install

More information

Basic System Administration ESX Server and Virtual Center 2.0.1

Basic System Administration ESX Server and Virtual Center 2.0.1 ESX Server 3.0.1 and Virtual Center 2.0.1 Basic System Administration Revision: 2006105 Item: VI-ENG-Q306-293 You can find the most up-to-date technical documentation on our Web site at http://www.vmware.com/support/

More information

Message Networking 5.2 Maintenance print guide

Message Networking 5.2 Maintenance print guide Page 1 of 304 Maintenance print guide This print guide is a collection of system topics provided in an easy-to-print format for your convenience. Note: The links shown in this document do not work online,

More information

Enterprise Vault.cloud Archive Migrator Guide. Archive Migrator versions 1.2 and 1.3

Enterprise Vault.cloud Archive Migrator Guide. Archive Migrator versions 1.2 and 1.3 Enterprise Vault.cloud Archive Migrator Guide Archive Migrator versions 1.2 and 1.3 Enterprise Vault.cloud: Archive Migrator Guide Last updated: 2018-01-09. Legal Notice Copyright 2018 Veritas Technologies

More information

HOW TO. Stratus Continuous Processing Technology. Automatic %+ Uptime for Red Hat Enterprise Linux Environments

HOW TO. Stratus Continuous Processing Technology. Automatic %+ Uptime for Red Hat Enterprise Linux Environments Stratus Technologies: Uptime. All the time. December, 2010 HOW TO Stratus Continuous Processing Technology Automatic 99.999%+ Uptime for Red Hat Enterprise Linux Environments Abstract Stratus Technologies

More information

IBM Personal Computer. About Your Software Windows 95, Applications, and Support Software

IBM Personal Computer. About Your Software Windows 95, Applications, and Support Software IBM Personal Computer About Your Software Windows 95, Applications, and Support Software IBM Personal Computer About Your Software Windows 95, Applications, and Support Software IBM Note Before using

More information

Codian IP VCR IP VCR 2200 Series

Codian IP VCR IP VCR 2200 Series Codian IP VCR IP VCR 2200 Series Getting Started Codian IP VCR IP VCR 2200 Series Getting Started Copyright Codian 2006. All rights reserved. This Getting Started Guide may not be copied, photocopied,

More information

HPE ProLiant Gen9 Troubleshooting Guide

HPE ProLiant Gen9 Troubleshooting Guide HPE ProLiant Gen9 Troubleshooting Guide Volume II: Error Messages Abstract This guide provides a list of error messages associated with HPE ProLiant servers, Integrated Lights-Out, Smart Array storage,

More information

Utilization of Agilent s Remote Management Cards RMC Plus L/LS 1.0 (N2521A-AT1/N2521A-AT3) in Intel s. Performance Appliance Platform.

Utilization of Agilent s Remote Management Cards RMC Plus L/LS 1.0 (N2521A-AT1/N2521A-AT3) in Intel s. Performance Appliance Platform. Utilization of Agilent s Remote Management Cards RMC Plus L/LS 1.0 (N2521A-AT1/N2521A-AT3) in Intel s Product Note Agilent Technologies offers a complete portfolio of server remote management solutions.

More information

Upgrading the Server Software

Upgrading the Server Software APPENDIXB This appendix describes how to upgrade or reinstall the Cisco PAM server software, desktop client software, and Gateway module firmware. Contents Upgrade Notes for Release 1.5.0, page B-2 Obtaining

More information

ProLiant CL380 Software User Guide. Fourth Edition (December 2000) Part Number Compaq Computer Corporation

ProLiant CL380 Software User Guide. Fourth Edition (December 2000) Part Number Compaq Computer Corporation ProLiant CL380 Software User Guide Fourth Edition (December 2000) Part Number 157839-004 Compaq Computer Corporation Notice 2000 Compaq Computer Corporation COMPAQ and the Compaq logo, Compaq Insight Manager,

More information

Endurance FTvirtual Server Commands

Endurance FTvirtual Server Commands Endurance FTvirtual Server Commands Marathon Technologies Corporation Fault and Disaster Tolerant Solutions for Windows Environments Release 6.1.1 June 2005 NOTICE Marathon Technologies Corporation reserves

More information

Cisco TEO Adapter Guide for Microsoft System Center Operations Manager 2007

Cisco TEO Adapter Guide for Microsoft System Center Operations Manager 2007 Cisco TEO Adapter Guide for Microsoft System Center Operations Manager 2007 Release 2.3 April 2012 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com

More information

EMC Secure Remote Support Device Client for Symmetrix Release 2.00

EMC Secure Remote Support Device Client for Symmetrix Release 2.00 EMC Secure Remote Support Device Client for Symmetrix Release 2.00 Support Document P/N 300-012-112 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05 EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N 300-002-038 REV A05 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2004-2006

More information

CA ehealth Integration for HP OpenView

CA ehealth Integration for HP OpenView CA ehealth Integration for HP OpenView User Guide r6.1 This documentation and any related computer software help programs (hereinafter referred to as the Documentation ) is for the end user s informational

More information

PGP NetShare Quick Start Guide Version 10.2

PGP NetShare Quick Start Guide Version 10.2 PGP NetShare Quick Start Guide Version 10.2 What is PGP NetShare? The PGP NetShare product is a software tool that provides multiple ways to protect and share your data. Use PGP NetShare to: Let authorized

More information

VERITAS NetBackup 6.0 for Microsoft SharePoint Portal Server 2001

VERITAS NetBackup 6.0 for Microsoft SharePoint Portal Server 2001 VERITAS NetBackup 6.0 for Microsoft SharePoint Portal Server 2001 System Administrator s Guide for Windows N152708 September 2005 Disclaimer The information contained in this publication is subject to

More information

SCOM 2012 with Dell Compellent Storage Center Management Pack 2.0. Best Practices

SCOM 2012 with Dell Compellent Storage Center Management Pack 2.0. Best Practices SCOM 2012 with Dell Compellent Storage Center Management Pack 2.0 Best Practices Document revision Date Revision Comments 4/30/2012 A Initial Draft THIS BEST PRACTICES GUIDE IS FOR INFORMATIONAL PURPOSES

More information

Dell DL4300 Appliance Release Notes

Dell DL4300 Appliance Release Notes Dell DL4300 Appliance Release Notes Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential

More information

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Release 3.0 SP1 User Guide P/N 302-000-098 REV 02 Copyright 2007-2014 EMC Corporation. All rights reserved. Published in the

More information

Hardware Installation Guide Installation (x3350)

Hardware Installation Guide Installation (x3350) Title page Nortel Application Gateway 2000 Nortel Application Gateway Release 6.3 Hardware Installation Guide Installation (x3350) Document Number: NN42400-300 Document Release: Standard 04.03 Date: January

More information

SNMP Web Management. User s Manual

SNMP Web Management. User s Manual SNMP Web Management User s Manual Suitable Product: SNMP Web Card SNMP Web Box Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2

More information

HP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide

HP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide HP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide AT459-96002 Part number: AT459-96002 First edition: April 2009 Legal and notice information Copyright 2009 Hewlett-Packard

More information

NEC ESMPRO AlertManager User's Guide

NEC ESMPRO AlertManager User's Guide NEC ESMPRO AlertManager User's Guide Chapter 1 General Description Chapter 2 Installation Chapter 3 Setting Chapter 4 Appendix AM_E-UG-W-001-01-004 NEC Corporation 2014 Contents Contents... 2 Notations

More information

Cisco TEO Adapter Guide for SAP ABAP

Cisco TEO Adapter Guide for SAP ABAP Release 2.3 April 2012 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part

More information

BrightStor ARCserve Backup for Windows

BrightStor ARCserve Backup for Windows BrightStor ARCserve Backup for Windows Volume Shadow Copy Service Guide r11.5 D01191-2E This documentation and related computer software program (hereinafter referred to as the "Documentation") is for

More information

Chapter. Configuring the Windows 2000 Environment MICROSOFT EXAM OBJECTIVES COVERED IN THIS CHAPTER

Chapter. Configuring the Windows 2000 Environment MICROSOFT EXAM OBJECTIVES COVERED IN THIS CHAPTER Chapter 4 Configuring the Windows 2000 Environment MICROSOFT EXAM OBJECTIVES COVERED IN THIS CHAPTER Implement, manage, and troubleshoot disk devices. Install, configure, and manage DVD and CD-ROM devices.

More information

1111 West 35th Street Chicago, IL Customer Support: (773) UPS SNMPWEBCARD

1111 West 35th Street Chicago, IL Customer Support: (773) UPS SNMPWEBCARD 1111 West 35th Street Chicago, IL 60609 Customer Support: (773) 869-1234 www.tripplite.com UPS SNMPWEBCARD USER S GUIDE FCC Radio/TV Interference Notice The SNMPWEBCARD has been tested and found to comply

More information

Veritas NetBackup Backup, Archive, and Restore Getting Started Guide. Release 8.1.2

Veritas NetBackup Backup, Archive, and Restore Getting Started Guide. Release 8.1.2 Veritas NetBackup Backup, Archive, and Restore Getting Started Guide Release 8.1.2 Veritas NetBackup Backup, Archive, and Restore Getting Started Guide Last updated: 2018-09-19 Legal Notice Copyright 2017

More information

NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL. Windows 2000 Platform Description and Installation Instructions

NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL. Windows 2000 Platform Description and Installation Instructions NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL Windows 2000 Platform Description and Installation Instructions This manual has been developed by NEC America, Inc. It is intended for the use

More information

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements Preface SIMATIC HMI Software SIMATIC HMI Software Programming Manual Overview 1 Range of functions of the RemoteOperate software 2 Hardware and software requirements 3 Installing RemoteOperate 4 Server

More information

Virtual Infrastructure Web Access Administrator s Guide ESX Server 3.0 and VirtualCenter 2.0

Virtual Infrastructure Web Access Administrator s Guide ESX Server 3.0 and VirtualCenter 2.0 Virtual Infrastructure Web Access Administrator s Guide ESX Server 3.0 and VirtualCenter 2.0 Virtual Infrastructure Web Access Administrator s Guide Revision: 20060615 Item: VI-ENG-Q206-217 You can find

More information

Web Device Manager Guide

Web Device Manager Guide Juniper Networks EX2500 Ethernet Switch Web Device Manager Guide Release 3.0 Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, CA 94089 USA 408-745-2000 www.juniper.net Part Number: 530-029704-01,

More information

Express5800/320Ma: Site Planning Guide

Express5800/320Ma: Site Planning Guide Express5800/320Ma: Site Planning Guide NEC Solutions (America), Inc. NR573 Notice The information contained in this document is subject to change without notice. UNLESS EXPRESSLY SET FORTH IN A WRITTEN

More information

Serial ATA PCI RAID Quick Installation Guide

Serial ATA PCI RAID Quick Installation Guide Serial ATA PCI RAID Quick Installation Guide Introducing the Serial ATA PCI RAID The Serial ATA PCI RAID is an ultra high-speed two channel Serial ATA controller board for use in Pentium-class computers.

More information

Flexible Array Storage Tool. User s Guide

Flexible Array Storage Tool. User s Guide Flexible Array Storage Tool User s Guide HP Part Number 5969-8465 Printed in January 2001 Copyright Copyright 2001, Hewlett-Packard Company. This document contains proprietary information that is protected

More information

Cisco UCS Diagnostics User Guide for B-Series Servers, Release 1.0

Cisco UCS Diagnostics User Guide for B-Series Servers, Release 1.0 First Published: October 25, 2013 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883

More information

NEC Express5800 Series NEC ESMPRO Agent User's Guide

NEC Express5800 Series NEC ESMPRO Agent User's Guide NEC Express5800 Series NEC ESMPRO Agent User's Guide PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs and related materials, is the valuable

More information

Symantec Workflow Solution 7.1 MP1 Installation and Configuration Guide

Symantec Workflow Solution 7.1 MP1 Installation and Configuration Guide Symantec Workflow Solution 7.1 MP1 Installation and Configuration Guide Symantec Workflow Installation and Configuration Guide The software described in this book is furnished under a license agreement

More information

ExpressCluster X SingleServerSafe 3.2 for Windows. Configuration Guide. 2/19/2014 1st Edition

ExpressCluster X SingleServerSafe 3.2 for Windows. Configuration Guide. 2/19/2014 1st Edition ExpressCluster X SingleServerSafe 3.2 for Windows Configuration Guide 2/19/2014 1st Edition Revision History Edition Revised Date Description First 2/19/2014 New manual Copyright NEC Corporation 2014.

More information

Dell PowerEdge RAID Controller (PERC) S130 User s Guide

Dell PowerEdge RAID Controller (PERC) S130 User s Guide Dell PowerEdge RAID Controller (PERC) S130 User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Cisco TEO Adapter Guide for

Cisco TEO Adapter Guide for Release 2.3 April 2012 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part

More information

Stratus ftserver 2510, 4410, and 6210 Systems: Site Planning Guide

Stratus ftserver 2510, 4410, and 6210 Systems: Site Planning Guide Stratus ftserver 2510, 4410, and 6210 Systems: Site Planning Guide Stratus Technologies R627-03 Notice The information contained in this document is subject to change without notice. UNLESS EXPRESSLY SET

More information

AST2500 ibmc Configuration Guide

AST2500 ibmc Configuration Guide AST2500 ibmc Configuration Guide Version 1.0b Copyright Copyright 2017 MITAC COMPUTING TECHNOLOGY CORPORATION. All rights reserved. No part of this manual may be reproduced or translated without prior

More information

Viewing System Status, page 404. Backing Up and Restoring a Configuration, page 416. Managing Certificates for Authentication, page 418

Viewing System Status, page 404. Backing Up and Restoring a Configuration, page 416. Managing Certificates for Authentication, page 418 This chapter describes how to maintain the configuration and firmware, reboot or reset the security appliance, manage the security license and digital certificates, and configure other features to help

More information

Unified Messenger 4.02 Installation Guide

Unified Messenger 4.02 Installation Guide Unified Messenger 4.02 Installation Guide Your comments on this document are welcome. They can assist us in improving our products. Please address comments to: Unified Messenger Documentation Team Avaya,

More information

Installation and User's Guide

Installation and User's Guide IBM Netfinity High-Availability Cluster Solutions Using the IBM ServeRAID -3H and IBM ServeRAID-3HB Ultra2 SCSI Controllers Installation and User's Guide IBM IBM IBM Netfinity High-Availability Cluster

More information

Veritas SaaS Backup for Office 365

Veritas SaaS Backup for Office 365 Veritas SaaS Backup for Office 365 Documentation version: 1.0 Legal Notice Copyright 2018 Veritas Technologies LLC. All rights reserved. Veritas and the Veritas Logo are trademarks or registered trademarks

More information

Operation. Symmetra MW II. Parallel System with Internal Bypass Static Switch. Normal Normal. UPS Summary. X405 UPS Summary.

Operation. Symmetra MW II. Parallel System with Internal Bypass Static Switch. Normal Normal. UPS Summary. X405 UPS Summary. X008B X010 X007 X021 X022 X012 X008A X014A X011 X405 X013 X017 X014B UPS Summary UPS Summary ~ ~ ~ ~ Normal Normal Normal Normal Operation Symmetra MW II Parallel System with Internal Bypass Static Switch

More information

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide. support.dell.com

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide.   support.dell.com Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5 User s Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better

More information

Cisco TEO Adapter Guide for SAP Java

Cisco TEO Adapter Guide for SAP Java Release 2.3 April 2012 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part

More information

CONTENTS. SysReturn_Manaual Updata 06/4/24. Chapter1 Introducing SysReturn Introduction to SysReturn Features and Functions...

CONTENTS. SysReturn_Manaual Updata 06/4/24. Chapter1 Introducing SysReturn Introduction to SysReturn Features and Functions... CONTENTS Chapter1 Introducing SysReturn... 3 Introduction to SysReturn... 3 Features and Functions... 3 Chapter2 Glossary... 5 Chapter3 System Requirement... 6 Hardware Requirement... 6 Software Requirement...

More information

USER MANUAL. PowerFrame TM Personal. UPS Monitoring Software

USER MANUAL. PowerFrame TM Personal.   UPS Monitoring Software USER MANUAL PowerFrame TM Personal UPS Monitoring Software www.bxterra.com 1 TABLE OF CONTENTS Introduction... Structure... Applications... Features... System Requirements... Supported Operating Systems...

More information

HP-UX Operating System: Fault Tolerant System Administration

HP-UX Operating System: Fault Tolerant System Administration HP-UX Operating System: Fault Tolerant System Administration HP-UX version 11.00.01 Stratus Technologies R1004H-06 Notice The information contained in this document is subject to change without notice.

More information

FCWnx 7.7 Upgrade Manual

FCWnx 7.7 Upgrade Manual FCWnx 7.7 Upgrade Manual P/N 460645003A 09AUG11 Copyright Disclaimer Trademarks and patents Intended use FCC compliance Certification and compliance 2011 UTC Fire & Security. All rights reserved. This

More information

Symantec NetBackup Vault Operator's Guide

Symantec NetBackup Vault Operator's Guide Symantec NetBackup Vault Operator's Guide UNIX, Windows, and Linux Release 7.6 Symantec NetBackup Vault Operator's Guide The software described in this book is furnished under a license agreement and may

More information

Log & Event Manager UPGRADE GUIDE. Version Last Updated: Thursday, May 25, 2017

Log & Event Manager UPGRADE GUIDE. Version Last Updated: Thursday, May 25, 2017 UPGRADE GUIDE Log & Event Manager Version 6.3.1 Last Updated: Thursday, May 25, 2017 Retrieve the latest version from: https://support.solarwinds.com/success_center/log_event_manager_(lem)/lem_documentation

More information

Veritas NetBackup for SQLite Administrator's Guide

Veritas NetBackup for SQLite Administrator's Guide Veritas NetBackup for SQLite Administrator's Guide Windows and Linux Release 8.1.1 Documentation version: 8.1.1 Legal Notice Copyright 2018 Veritas Technologies LLC. All rights reserved. Veritas and the

More information

USER S GUIDE. Integrated RAID for SAS. April Version 1.1 DB

USER S GUIDE. Integrated RAID for SAS. April Version 1.1 DB USER S GUIDE Integrated RAID for SAS April 2007 DB15-000357-01 Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation. The information contained herein is not

More information

OneVision DEFINITY G3 Fault Management Installation and Integration for AT&T OneVision

OneVision DEFINITY G3 Fault Management Installation and Integration for AT&T OneVision 585-229-109 Issue 1 October, 1995 Table of Contents OneVision DEFINITY G3 Fault Management Installation and Integration for AT&T OneVision Graphics AT&T 1988 Blank Page Contents About This Book vii Intended

More information

Commander TM Site Controller

Commander TM Site Controller Commander TM Site Controller Software Installation Guide P/N: DOC149-004-01-B Revision: A00 Commander Site Controller Software Installation Guide VeriFone, Inc. 2099 Gateway Place Suite 600 San Jose,

More information