1500V - Vacuum Rated

Similar documents
Mercury Manual No. IM-M1000 Rev G

O.P.S. Series Encoders

ChipEncoder Series. Installation Manual and Reference Guide. Sensor Installation Manu >CELERAMOTION

Performance and Value Optical Encoder System. Specifications. Benefits

SDG1400 User s Guide

Resolver to Digital Expansion Board

Linear Positioning Stage Reference Manual

Operating Instruction for IQ Series laser diode module Instructions for IQ1C, IQ2C, IQ4C, IQ6, IQ7, IQ1A, IQ2A, IQ4A, IQ1H, IQ2H and IQ4H

MTE Series Encoders. Performance and Value Compact Linear Encoder. Specifications. Benefits

Operation Instruction for CNI Model with PSU-III-LCD

Optira Series Encoders

PLD Series +5V Laser Diode Drivers

Mercury II 1900 The Next Generation of High Performance Encoders High Performance Analog 1Vpp Output with Linear Tape or Glass Scales

Precision Piezo Stage Reference Manual (Open and Closed Loop Versions)

RT209 OEM Scan Engine. RT209 Integration Guide. Integration Guide

StingRay and BioRay FEATURES

VT-50. Linear Positioning Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

PR-32. Piezo Rotation Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

MulTI-Touch Projected Capacitive Touch Screen Integration Guide

Keysight M8000 Series BER Test Solutions

SENC 150 REFERENCE MANUAL

DF-60 Rotary Electric Encoder

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Lyte-MV Analogue Userguide Red & IR Versions

Package Options. Transmitter (TX) PLD-1315TM PLD-1315M

OTEB-CO-B Series. Booster EDFA OPERATING MANUAL

Module Connectors and Cable Specifications

Models 1417 and 1437 User s Manual. High-Speed Photodetector Modules

600 mw Fiber Bragg Grating Stabilized 14xx nm Pump Modules with Ultra-Low Power Consumption. S35 Series

LegacyPlus 7-OR SERIES RETURN TRANSMITTER INSTRUCTION MANUAL 7-OR-RT/xxx

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

Installing Your 1394 Drive Interface Module

LIMO LM Medical Series Version March 01, 2010 HIGH-POWER DIODE LASER

Optira Series. Encoders. MicroE NANO. Miniature Precision Encoders for the World s Smallest Spaces. Encoders PRODUCT DATA SHEET

MINISCALE PLUS Product Overview

PPS-28. Precision Piezo Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

SF10 SF10. Features: The SF10 laser altimeter is ideal for automated landings and precision hovering.

Installing the Cisco MDS 9020 Fabric Switch

Lyte-MV Digital Userguide Red & IR Versions

2201 Rack Chassis User Manual

MODEL 8000MP LEVEL SENSOR

Ground Master Monitor Installation, Operation and Maintenance

and Network Interface Modules Installation Instructions

Technical Manual SMART TRAC PG Card

BRIGHTBOX-E1 LASER DIODE ENGINE

Up to 200 mw Uncooled 980 nm Pump Modules. TO T13 Series

Model 2657A-LIM-3 LO Interconnect Module

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

0,25 mm false pulse suppression 4 program options 4 program options on/off switchable 4 preset levels or level set by customer.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

ENC 125 T/E REFERENCE MANUAL. Acu-Rite Companies Inc.

SpectraTec X. Multi- λ Laser Light Source BLUE SKY RESEARCH WAVELENGTHS

EH-RIO IP67 Profibus-DP I/O modules

Ruger SR22. Operator s Manual RUGER SR22 SR9C SR40C 9E LMS-RMSR

Survival Laser SL-005PB Laser Parts Bundle Assembly & Operation Instructions

PowerFlex 755 Common DC Input Drives, Frames Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Model 7705 Control Module

PCM-7140 Pulsed Current Source Operation Manual

Transmission Media. Criteria for selection of media. Criteria for selection of media 2/17/2016. Chapter 3: Transmission Media.

ACL 350 Digital Static Locator

Description. Applications

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

Laser Diode Controller Instruction Manual

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION INSTRUCTION MANUAL FMX-125

Butterfly Laser Diode Mount

Ultra Low Noise Laser 1550nm

SUM-40 OPERATING MANUAL. Ma0 DYNAMIC STRUCTURES AND MATERIALS, LLC REV

SCIENCEWORKSHOP 750 INTERFACE. Instruction Sheet for the PASCO Model CI Introduction

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Print Mechanism Maintenance Kit

Cutter Option Installation Instructions

Model GHz 50 Ohm RF Module

INSTRUCTION MANUAL HIGH CURRENT DRIVER BOARD STAND ALONE

OPLC Installation Guide

SynJet PAR25 LED Cooler with Heat Sink

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

FL MC 2000E (SM40) LC

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

PCI 2 Axis Servo Card

MV SERIES MACHINE VISION STROBOSCOPE. Operating Manual

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Installation Job Aid for Ethernet Routing Switch 3600 Series

EMC Installation Guide

Survival Laser SL-002PB Laser Parts Bundle w/g-1 Lens Assembly & Operation Instructions

LASER PLUS OPERATING INSTRUCTIONS

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

SPECIFICATIONS. Laser Diode GH0652AA2G

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

4100/ VDC Converter Installation Instructions

Installation Job Aid for Ethernet Routing Switch 5900 Series

5.0X6.0mm SURFACE MOUNT LED LAMP. Features. Description. Package Dimensions

PCI 2 Axis Servo Card

Genesis MX STM-Series

Appendix D. EMC Installation Guidelines. Safety Considerations. Ferrite Absorbers and P-Clips. General Product Philosophy

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

Transcription:

Preliminary 8/20/2008 Mercury Digital Output Encoder System Installation Manual and Reference Guide 1500V - Vacuum Rated Customer Controller Vacuum Wall Manual No. IM-M1500V Rev S7

Introduction MicroE Systems was founded to advance encoder technology to a level never before achieved. Our objective was to design encoder systems that would be small enough to fit into densely packed OEM equipment designs, affordable enough for cost-sensitive applications and easy enough to enable installation, setup and alignment by assemblers with little training. We are pleased to say that all of these goals have been realized with the introduction of the Mercury family of encoders. M10 Sensor shown actual size Precautions 1 2 Follow standard ESD precautions. Turn power off before connecting the sensor. Do not touch the electrical pins without static protection such as a grounded wrist strap. Do not touch the glass scale unless you are wearing talc-free gloves or finger cots. Please read this installation manual for full instructions. LASER SAFETY INFORMATION: Mercury & ChipEncoder This product is sold solely for use as a component (or replacement) in an electronic product; therefore it is not required to, and does not comply with, 21 CFR 1040.10 and 1040.11 which pertain to complete laser products. The manufacturer of the complete system-level electronic product is responsible for complying with 21 CFR 1040.10 and 1040.11 and for providing the user with all necessary safety warnings and information. MicroE encoders contain an infrared laser diode or diodes. Emitted invisible laser radiation levels have been measured to be within the CDRH Class 1 range, which is not considered hazardous; however, to minimize exposure to the diverging beam, the encoder sensor should be installed in its operational configuration in close proximity to the encoder scale before power is applied. INVISIBLE LASER RADIATION DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS (MICROSCOPES, EYE LOUPES OR MAGNIFIERS) Invisible laser radiation; wavelength: 850 nm Max power 2.4 mw CW (4.8 mw CW for Mercury II ) CAUTION The use of optical instruments with this product will increase eye hazard. DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS (MICROSCOPES, EYE LOUPES OR MAGNIFIERS). All maintenance procedures such as cleaning must be performed with the MicroE encoder turned off. Do not insert any reflective surface into the beam path when the encoder is powered. Do not attempt to service the MicroE encoder. Patents Covered by the following patents: US 5,991,249; EP 895,239; JP 3,025,237; US 6,897,435; and EP 1,451,933. Additional patents and patents pending may apply.

Table of Contents SYSTEM ILLUSTRATION PAGE Encoder with Linear scale 2 Encoder with Rotary scale 3 INSTALLATION INSTRUCTIONS Using SmartPrecision Alignment Tool - Linear Scales Mounting Encoder System 4 Alignment of Encoder System 5 Using SIN/COS Signals - Linear Scales Mounting Encoder System 6 Alignment of Encoder System 7 Establishing an Index 7 Using SmartPrecision Alignment Tool - Rotary Scales Mounting Encoder System 8 Alignment of Encoder System 9 Using SIN/COS Signals - Rotary Scales Mounting Encoder System 10 Alignment of Encoder System 11 Establishing an Index 11 REFERENCE SECTION Installation of Linear Scales 12 Grounding Instructions 13 Recommendations for Power 13 Customer Interface Cable Requirements 14 Output Signal description 15 ENCODER TROUBLESHOOTING Selected Topics 16 Cleaning Scales 16 Contact MicroE Systems Back Cover Page 1

Mercury TM with Linear scale 1500V Encoder System System View Shown with linear scale Vacuum wall Sensor 15 pin standard D-sub connector Linear glass scale (shown mounted on a linear slide) SmartPrecision Alignment Tool SSAT1500-V Expanded View Mounting screws & flat washers (2 needed per screw) Optional sensor benching pins (3) Sensor mounting holes (2) Typical user-supplied sensor mounting bracket Atmospheric Cable Vacuum wall Double shielded cable Bracket mounting holes (2) Scale reference datum; example shown with benching pins End locator pin Page 2

Mercury 1500V Encoder System with Rotary scale System View Shown with rotary scale sensor Vacuum wall 15 pin standard D-sub connector Rotary glass scale SmartPrecision Alignment Tool SSAT1500-V Expanded View Vacuum compatable cable Mounting screws & flat washers (2 needed per screw) Vacuum wall Atmospheric Cable Double shielded cable Flying leads Top reflective rotary scale Page 3

Installation Instructions Linear Encoders - Using Alignment Tool - Mounting 1 Attach the scale to the base slide. Reference the preferred datum on the interface drawing for either end or center index orientation. Depending on the mounting method, attach the scale to the slide with adhesive. Refer to pg. 12 for details. Be sure the grating surface of the scale faces the sensor. Insure that there is no contact between these surfaces or damage may result. 2 Install the sensor on your mounting surface referencing the appropriate datum surface as shown on the interface drawing. Use 2 washers per mounting screw. Benching pins may be used to locate the sensor if the system mechanical tolerances are adequate. See data sheet for alignment tolerances, or keep mounting screws loose for sensor alignment if benching pins are not used. 3 Be sure the source power is off before connecting the SmartPrecision TM II Alignment Tool. Connect the M1500V to the SmartPrecision II Alignment Tool. (The M1500V-AC Atmospheric Cable shown in the illustration above is optional. A customer-supplied cable may be used.) To Power Supply 4 Connect the Alignment Tool to the Computer Interface Adapter. Turn on the power. To M1500V encoder Page 4

Installation Instructions Linear Encoders - Using Alignment Tool - Alignment 5 Proper sensor alignment may require minor adjustments to the sensor position with respect to the scale. This can be performed easily using the SmartPrecision Alignment Tool as illustrated below. The red, yellow, or green LED will light depending on sensor alignment. Slowly move the sensor by allowing it to slide on the mounting surface until the green LED, is illuminated. Optimal alignment will be displayed as a Bright Green LED. IMPORTANT: Confirm that the green LED blinks when passing over the index. If not, readjust the sensor in the Y direction and repeat the above procedure. When alignment is completed, tighten the sensor mounting screws. x θ z Y Z To align the sensor, move it in the Y or θ z directions. SmartPrecision Alignment Tool Power/ Calibration Power/ Calibration Power/ Calibration Improper Alignment LED Red SmartPrecision Alignment Tool SSAT1000 15 pin D connector to sensor Improved Alignment LED Yellow SmartPrecision Alignment Tool SSAT1000 15 pin D connector to sensor Proper Alignment LED Green Optimal Alignment LED Bright Green SmartPrecision Alignment Tool SSAT1000 15 pin D connector to sensor 6 Confirm green over the full range of motion by sliding the scale past the sensor. The green LED must remain on over the entire range. If not aligned over the entire range of motion, loosen the sensor mounting screws and repeat step 5. Page 5

Installation Instructions Linear Encoders - Using Sin/Cos Signals - Mounting 1Attach the scale to the base slide. Reference the preferred datum on the interface drawing for either end or center index orientation. Depending on the mounting method, attach the scale to the slide with adhesive. Refer to pg. 12 for details. Be sure the grating surface of the scale faces the sensor. Insure that there is no contact between these surfaces or damage may result. 2 Install the sensor on your mounting surface referencing the appropriate datum surface as shown on the interface drawing. Use 2 washers per mounting screw. Benching pins may be used to locate the sensor if the system mechanical tolerances are adequate. See data sheet for alignment tolerances, or keep mounting screws loose for sensor alignment if benching pins are not used. 3Be sure power is off before connecting the sensor. Connect the M1500V to your interface electronics using the wire color/signal assigments described on the interface drawing. Tighten the connector screws. Power up the system. Page 6

Installation Instructions Linear Encoders - Using Sin/Cos Signals - Alignment 4 MAIN TRACK ALIGNMENT If benching dimensions cannot be provided, proper sensor alignment may require minor adjustments to the sensor position with respect to the scale. This can be performed by maximizing the sine signal from the M1500V. Using an oscilloscope, monitor the sine or cosine signal (refer to the interface drawing for pinouts) while moving the sensor over the scale. Align the sensor until 0.8 volts peak-to-peak +/- 25% is obtained. When alignment is completed, tighten the sensor mounting screws (0.37Nm [3.3 inch-lbs.] maximum torque). x θ z Y Z To align the sensor, move it in the Y or θ z directions. 1.7 V offset (nominal) 1.2 0.6 0.8 V pp 0 5 INDEX TRACK ALIGNMENT The M1500V must be aligned for both the main and index tracks. When properly aligned, the sensor will produce an index window as the sensor passes over the index mark. The index window is approximately one fringe wide (20µm). To verify proper index track alignment, use a digital oscilloscope triggered on the index window. Refer to the interface drawing for the index window pinout. Confirm proper alignment of the main track over the full range of motion. If not aligned over the entire range of motion, loosen the sensor mounting screws and repeat steps 4 and 5. Page 7

Installation Instructions Rotary Encoders - Using Alignment Tool - Mounting 1 Attach your hub/scale assembly to the rotary device. Refer to the interface drawing. The reflective surface of the scale must face the sensor. 2 Install the sensor on your mounting surface referencing the appropriate datum surface as shown on the interface drawing. Use 2 washers per mounting screw. Benching pins may be used to locate the sensor if the system mechanical tolerances are adequate. See data sheet for alignment tolerances, or keep mounting screws loose for sensor alignment if benching pins are not used. To Power Supply 3Be sure the source power is off before connecting the SmartPrecision Alignment Tool. (The M1500V-AC Atmospheric Cable shown above is optional. A customer-supplied cable may be used.) Connect the M1500V encoder to the SmartPrecision Alignment Tool. 4Connect the Alignment Tool to the Computer Interface Adapter. Turn on the power. To M1500V encoder Page 8

Installation Instructions Rotary Encoders - Using Alignment Tool - Alignment 5Proper sensor alignment may require minor adjustments to the sensor position with respect to the scale. This can be performed easily using the SmartPrecision Alignment Tool as illustrated below. The red, yellow, or green LED will light depending on sensor alignment. Slowly move the sensor by allowing it to slide on the mounting surface until the green LED, is illuminated. Optimal alignment will be displayed as a Bright Green LED. IMPORTANT: Confirm that the green LED blinks when passing over the index. If not, readjust the sensor in the Y direction and repeat the above procedure. When alignment is completed, tighten the sensor mounting screws. x θ z Y Z To align the sensor, move it in the Y or θ z directions. SmartPrecision Alignment Tool Power/ Calibration Power/ Calibration Power/ Calibration Improper Alignment LED Red SmartPrecision Alignment Tool SSAT1000 15 pin D connector to sensor Improved Alignment LED Yellow SmartPrecision Alignment Tool SSAT1000 15 pin D connector to sensor Proper Alignment LED Green Optimal Alignment LED Bright Green SmartPrecision Alignment Tool SSAT1000 15 pin D connector to sensor 6 Confirm green over the full range of motion by sliding the scale past the sensor. The green LED must remain on over the entire range. If not aligned over the entire range of motion, loosen the sensor mounting screws and repeat step 5. Page 9

Installation Instructions Rotary Encoders - Using Sin/Cos Signals - Mounting 1Attach your hub/scale assembly to the rotary device. Refer to the interface drawing. The reflective surface of the scale must face the sensor. 2Install the sensor on your mounting surface referencing the appropriate datum surface as shown on the interface drawing. Use 2 washers per mounting screw. Benching pins may be used to locate the sensor if the system mechanical tolerances are adequate. See data sheet for alignment tolerances, or keep mounting screws loose for sensor alignment if benching pins are not used. 3Be sure power is off before connecting the sensor. Connect the M1500V to your interface electronics using the wire color/signal assignments described on the interface drawing. Tighten the connector screws. Power up the system. Page 10

Installation Instructions Rotary Encoders - Using Sin/Cos Signals - Alignment` 4 MAIN TRACK ALIGNMENT If benching dimensions cannot be provided, proper sensor alignment may require minor adjustments to the sensor position with respect to the scale. This can be performed by maximizing the sine signal from the M1500V. Using an oscilloscope, monitor the sine or cosine signal (refer to the interface drawing for pinouts) while moving the sensor over the scale. Align the sensor until 0.8 volts peak-to-peak +/- 25% is obtained. When alignment is completed, tighten the sensor mounting screws (0.37Nm [3.3 inch-lbs.] maximum torque). x θ z Y Z To align the sensor, move it in the Y or θ z directions. 1.7 V offset (nominal) 1.2 0.6 0.8 V pp 0 5INDEX TRACK ALIGNMENT The M1500V must be aligned for both the main and index tracks. When properly aligned, the sensor will produce an index window as the sensor passes over the index mark. The index window is approximately one fringe wide (20µm). To verify proper index track alignment, use a digital oscilloscope triggered on the index window. Refer to the interface drawing for the index window pinout. Confirm proper alignment of the main track over the full range of motion. If not aligned over the entire range of motion, loosen the sensor mounting screws and repeat steps 4 and 5. Page 11

Reference Section Installation of Linear Scales Positioning the Scale Note: Before beginning mounting procedure, use talc-free gloves or finger cots to handle the scales. Also use vacuum compatible handling procedures and materials. "Benching" the scale to the system means aligning the scale by means of benching pins. Pin locations are described on the appropriate interface drawing. Two benching pins are recommended on the long side of the scale and one at the end as shown. This is marked datum A on the interface drawing. 1 Position the benching pins in from either end. 20% of the overall scale length is the recommended location from the edge. Be sure the benching pins do not extend too high in the Z direction to 2 prevent mechanical interference with the sensor or sensor mount. End Benching Pin 0.2L 0.6L 0.2L L Benching pins MicroE Systems Mounting the Scale Suggested Epoxy and Clamp Mounting 1 Make sure the mounting surface is clean and dry. 3 Scale clamps (customer supplied) may be used to mechanically secure the scale. The clamps should allow for thermal expansion of the scale and mounting surface. Make sure that the clamps do not interfere with the sensor or sensor mount. Note: adhesive used on clamps supplied by MicroE is not vacuum rated. End Benching Pin Mounting clamp L Mounting clamp Scale clamp Hard epoxy at one corner, this end only. Mounting clamp Benching pins MicroE Systems Side view showing suggested scale clamps and scale. Space clamps every 75mm on scales over 150 mm in length. 2Align the scale by placing the edges against the benching pins. 4 Apply a hard, vacuum compatible epoxy to the end of the scale at the end benching pin. Page 12

Grounding Instructions for Mercury 1500V Encoder Systems Installation Reference Guide Correct grounding can be implemented in several ways depending on how the customer implements the connections through the vacuum chamber wall. The diagram below is suitable where: The outer cable shields are electrically isolated from each other at the vacuum chamber wall. The sensor is mounted with good electrical contact to a well-grounded surface. (Note that an electrical path through bearings will not result in a well-grounded sensor.) Connector pins Power Supply 5 Volts 0 Volts Electrically conductive mechanical connection (as supplied by MicroE Systems). Do not ground shroud. Vacuum Chamber wall Note: specific Specific applications may require may require a different a different grounding grounding scheme. Contact scheme. MicroE Please Systems contact for applications MicroE support. Systems Application grouip with details for assistance. Shielding Instructions Customer-installed connectors at the vacuum chamber wall must electrically shield the signal wires from Electro Magnetic Interference, Radio Frequency Interference and Electro Static Discharge. The connectors' shielding must completely surround the wires with no gaps, including intimate electrical contact 360 degrees around the outer cable shields at the ends of the cables supplied with flying leads. The inner shield of the cable that is attached to the SmartPrecision electronics module must be electrically isolated from the outer shield. Important Note MicroE Systems recommends testing the motion subsystem after the Mercury 1500V encoders are installed using your vacuum throughwall connectors. The testing should prove that the motion system has sufficient immunity to Electro Magnetic Interference, Radio Frequency Interference and Electro Static Discharge according to the application requirements. Recommendations for Power Mercury encoders require a minimum of 4.75V DC continuously. When designing circuits and extension cables to use Mercury encoders, be sure to account for voltage loss over distance and tolerances from the nominal supply voltage so that at least 4.75V DC is available to the Mercury encoder under all operating conditions. The input voltage should not exceed 5.25V DC. Page 13

Customer Interface Cable Requirements Customer cables that interface to Mercury series encoders must have the following characteristics: Twisted pair signal wiring. Characteristic impedance of 100-120 ohms. Sufficient wire gauge to meet the minimum voltage requirement at the encoder, for example 24AWG gauge wire for a 2m length cable. Examples of acceptable cables with 24 AWG gauge wire and 4 twisted pairs are Belden 9831, 8104, and 9844 or other manufacturer's equivalents. Single shield cable with a minimum of 90% coverage. Note that a double shielded cable may be required in high-noise applications. Signal Wiring: Each differential signal should be connected to a corresponding twisted pair as follows: Mercury 1500V Signal Twisted Pair A+ Pair 1 A- B+ Pair 2 B- Index+ Pair 3 Index- +5V Pair 4 GND Shield Termination: The customer's cable shield should be in 360 contact with the connector shroud and the connector shell to provide complete shielding. The connector shell should be metal with conductive surfaces. Suggested metal connector shells for use with Mercury 3500, 3000, 3000Si, and 2000 encoders: AMP 748676-1 or equivalent; for Mercury 1000 and 1500V encoders: AMP 745172-3, -2, or -1 where the dash number is dependent on the customer's outside cable diameter. The shield should be terminated as illustrated in the following diagram. Fold braided shield back over jacket. Example shows double-shielded cable. Dimensions shown are for illustration only. Page 14

Output Signal Description SINE+/COSINE+ Analog signal with nominal peak to peak amplitude of 0.8V. The output signal has a source impedance of 1KΩ. This signal is only used to align the sensor using an oscilloscope and is not suitable for feedback in a control system. 1.2 0.8V pp ±25% single ended 1.7 V offset (nominal) 0.6 0-0.6-1.2 Output Signal Description A+/A- B+/B- Digital Quadrature output. Signal is a RS-422 compatible square wave. Pulses are 90 out of phase with B+/B- outputs. Please see below. Digital Quadrature output. Signal is a RS-422 compatible square wave. Pulses are 90 out of phase with A+/A- outputs. Please see below. Index Window The Index Window defines one particular fringe on the grating. Output from 8X encoder shown 1.2 0.6 0-0.6 A+ B+ Index+ A+, B+ and Index Window+ Page 15

Troubleshooting Problem The Power/Calibration indicator will not come on. Solution Make sure the M1500V 15-pin D connector is fully seated and connected. Confirm that +5 Volts DC is being applied to pin 12 on the M1500V 15-pin D connector and that pin 13 is connected to ground. Problem Can't get the SmartPrecision Alignment Tool "Signal" LEDs better than red or yellow; or the green, green indicator doesn't stay illuminated over the full length of the scale. Solution Verify that the sensor has been aligned to the scale and that the mounting screws are tight. Check the dimensions for the mechanical mounting holes (and clamps if any) to make sure that the sensor is correctly located over the scale. Refer to the appropriate interface drawing. Check that the scale is firmly mounted and can't jiggle or move in other than the intended direction. Make sure that the scale is clean over its entire length or circumference. Use the recommended Cleaning Scales procedure. Cleaning Scales General Particle Removal Blow off the contamination with nitrogen, clean air, or a similar gas. Contamination Removal Use a lint-free cleanroom wipe or cotton swab dampened with isopropyl alcohol or acetone only to wipe the surface clean. Handle the scale by the edges. Do not scrub the scale. Page 16

Contact MicroE Systems Thank you for purchasing a MicroE Systems product. You should expect the highest level of quality and support from MicroE. If you want to download the Mercury Encoder Installation Manual, Data Sheet or Interface Drawing, browse www.microesys.com and click on the Mercury Encoders button. World Headquarters: 125 Middlesex Turnpike Bedford MA 01730 USA www.microesys.com info@microesys.com T. [781] 266-5700 F. [781] 266-5112 2008 MicroE Systems