DATA SHEET TM COEX 3000 TriMode Series 6 Ex d Camera Station The COEX 3000 TriMode camera station 6 series has a unique compact and lightweight design specifically developed for hazardous area applications. Combined with the latest thermal imaging technology with a day / night (colour / mono) camera module the C3000 TriMode camera stations ensure unprecedented visual feedback in all light conditions. Utilised around the world to assist with: Pipeline monitoring Navigation during night time and foggy conditions Ice Detection Piracy Detection Man-overboard Safety Environmental Protection Intruder Detection Safety and Security Protection Even during daylight the C3000 TriMode can provide increased visibility over conventional camera stations with human detection at over 1100 m *3/4 COEX Series 6 camera stations are fitted with a 640 x 480 thermal imaging camera and a high resolution analogue day / night camera with removable IR cut filter. Features ATEX II 2 GD Certification IECEx Certification Ex d IIC, T4, T5 or T6 DNV Type Approval IP66 & 68 Rated completely protected against dust & water ingress, for the most extreme environments Electro-polished 316L stainless steel, for maximum corrosion resistance TriMode Operation Day (colour), Night (mono) and Thermal Imaging Low Voltage Operation Preset accuracy and repeatability of <0.05 Advanced Mechanical Design to minimise size and weight Pre-Heat Mode for safe start up in freezing conditions Smart Move Technology assists target acquisition and tracking Germanium and Toughened Glass Options Continuous Rotation [C] Absolute Positioning Integral Wiper [W] COEX FEWS Ex Pressurised Wash System Integral Fibre Optic Transmission (via alternative base) Fibre Optic Transmission (via associated junction box) IP within the Camera Housing COEX Wall Mount Bracket COEX Range of Tilt Down Towers and accessories
COEX TM 3000 TriMode Series 6 Ex d Camera Station DATA SHEET Specifications CERTIFICATIONS / RATINGS Certifications / Ratings ENVIRONMENTAL Operating Temperature MECHANICAL Material Pan Operation Tilt Operation Mounting Dimensions (W x D x H) Pan Turning Circle Weight Ex d IIC T4 / T5 / T6 Gb; Ex tb IIIC T4 / T5 / T6 Db; ATEX II 2GD IECEx DNV Type Approval CE Compliant to EMC Directive IP66 & IP68 to IEC 60529 (30m Submersion for 4 hrs) -55 C to +60 C -45 C to +60 C Electro-polished 316L Stainless Steel Germanium and Toughened Glass, Thermostatically Operated Demister [Wiper for Day / Night View only] 362 rotation @ 0 to 42 /sec; Mechanical Limits; Programmable Soft-stops; Preset Positioning [Continuous Rotation] 180 rotation @ 0 to 21 /sec; Mechanical Limits; Programmable Soft-stops; Preset Positioning 4 x M8 tapped holes, equispaced on a 4 (101.6 mm) P.C.D. 429 x 310 x 368 mm Ø 660 mm 29 kg ELECTRICAL Power Requirements 24Vac 50 / 60Hz or 24Vdc (±10%) Power Consumption 92VA Maximum TELEMETRY Interface Protocols* 2 Day/Night Camera Thermal Camera OSD RS485 serial asynchronous data Synectics, Pelco, and other industry standard protocols available Pan, Tilt, Zoom, Aux1, [Aux2] and Aux in On / Off Selection of: Digital Zoom, BLC, Autofocus; Auto / Manual Selection of: Focus, Colour / Mono Operation, Frame Integration, White Balance Continuous Electronic Zoom, Multiple Colour Palettes (including Inverted), Multiple Contrast Display, Contrast and Level Control, Hot and Cold Spot, Auto / Manual Shuttering Password protected on-screen menu system for camera station configuration and diagnostics CAMERA / LENS C3000-2V36-T6>>[2C36] [W] *5 C3000-2V10-T6>>[2C10] [W] *5 Video Output 1.0 Vpk-pk CVBS into 75Ω; Colour PAL 50Hz [NTSC 60Hz] Image Sensor ¼ EXview HAD CCD 1 3 Super HAD CCD II Resolution >550TVL >530TVL S/N Ratio >50dB Zoom Range 36x zoom (up to 432x with digital zoom) 10x zoom (up to 120x with digital zoom) Minimum Illumination 1.4 lux 0.1 lux (with 1 3 sec integration) 0.01 lux mono (with 1 3 sec integration) 0.25 lux 0.015 lux (with 1 3 sec integration) 0.0004 lux mono (with 1 3 sec integration) Focal Length 3.4 to 122.4 mm 5.1 to 51 mm Angle of View 57.8 to 1.7 52 to 5.4 Aperture F1.6 to 4.5 F1.8 to 2.1 THERMAL IMAGER C3000-2V<<-T650 [2C<<] [W] *5 C3000-2V<<-T625 [2C<<] [W] *5 Image Sensor Amorphous Silicon Microbolometer Spectral Response 8 14 µm Thermal Sensitivity 70mK [50mK] Refresh Rate <9Hz [25Hz] Resolution 640 x 480 Fixed Focal Length 50 mm 25 mm Angle of View 12.4 x 9.3 25 x 18.7 Human Detection* 3/4 ~1100 m ~560 m [options] NOTE: *1 Dependant on equipment fitted. *2 Refer to Synectics for availability and compatibility with other control systems *3 Based on Johnson Criteria. *4 Actual range may vary depending on camera set-up, user experience, environmental conditions and type of monitor or display used. *5 >> replace with thermal camera module and << replace with day / night camera module. Synectic Systems sales@synecticsglobal.com synecticsglobal.com Specifications subject to change. E & OE. Copyright Synectic Systems Group Ltd, Synectic Systems, Inc. 2014. All Rights Reserved ISO 9001 Registered Quality Management 015 BS EN ISO 9001 CERTIFICATE No. 0956 Reference Numbers: 03GF0614_2 C3000T2S6/0414/A4 Iss 2
DATA SHEET TM COEX 3000 TriMode Series 3 Ex d Camera Station The COEX 3000 TriMode camera station 3 series has a unique compact and lightweight design specifically developed for hazardous area applications. Combined with the latest thermal imaging technology with a day / night (colour / mono) camera module the C3000 TriMode camera stations ensure unprecedented visual feedback in all light conditions. Utilised around the world to assist with: Navigation during night time and foggy conditions Ice Detection Piracy Detection Man-overboard Safety Environmental Protection Intruder Detection Safety and Security Protection Even during daylight the C3000 TriMode can provide increased visibility over conventional camera stations with human detection at over 1100 m *3/4 COEX Series 3 camera stations are fitted with a 384 x 288 analogue thermal imaging camera and a high resolution analogue day / night camera with removable IR cut filter Features ATEX II 2 GD Certification IECEx Certification Ex d IIC, T4, T5 or T6 DNV Type Approval IP66 & 68 Rated completely protected against dust & water ingress, for the most extreme environments Electro-polished 316L stainless steel, for maximum corrosion resistance TriMode Operation Day (colour), Night (mono) and Thermal Imaging Low Voltage Operation Preset accuracy and repeatability of <0.05 Advanced Mechanical Design to minimise size and weight Pre-Heat Mode for safe start up in freezing conditions Smart Move Technology assists target acquisition and tracking Germanium and Toughened Glass Options Continuous Rotation [C] Absolute Positioning Integral Wiper [W] COEX FEWS Ex Pressurised Wash System Integral Fibre Optic Transmission (via alternative base) Fibre Optic Transmission (via associated junction box) IP within the Camera Housing COEX Wall Mount Bracket COEX Range of Tilt Down Towers and accessories
COEX TM 3000 TriMode Series 3 Ex d Camera Station DATA SHEET Specifications CERTIFICATIONS / RATINGS Certifications / Ratings ENVIRONMENTAL Operating Temperature MECHANICAL Material Pan Operation Tilt Operation Mounting Dimensions (W x D x H) Pan Turning Circle Weight *1 Ex d IIC T4 / T5 / T6 Gb; Ex tb IIIC T4 / T5 / T6 Db; ATEX II 2GD IECEx DNV Type Approval CE Compliant to EMC Directive IP66 & IP68 to IEC 60529 (30m Submersion for 4 hrs) -55 C to +60 C -45 C to +60 C Electro-polished 316L Stainless Steel Germanium and Toughened Glass, Thermostatically Operated Demister [Wiper for Day / Night View only] 362 rotation @ 0 to 42 /sec; Mechanical Limits; Programmable Soft-stops; Preset Positioning [Continuous Rotation] 180 rotation @ 0 to 21 /sec; Mechanical Limits; Programmable Soft-stops; Preset Positioning 4 x M8 tapped holes, equispaced on a 4 (101.6 mm) P.C.D. 429 x 310 x 368 mm Ø 660 mm 29 kg ELECTRICAL Power Requirements 24Vac 50 / 60Hz or 24Vdc (±10%) Power Consumption 92VA Maximum TELEMETRY Interface Protocols* 2 Day / Night Camera Thermal Camera OSD RS485 serial asynchronous data Synectics, Pelco, and other industry standard protocols available Pan, Tilt, Zoom, Aux1, [Aux2] and Aux in On / Off Selection of: Digital Zoom, BLC, Autofocus Auto / Manual Selection of: Focus, Colour / Mono Operation, Frame Integration, White Balance Continuous Electronic Zoom, Multiple Colour Palettes (including Inverted), Multiple Contrast Display, Contrast and Level Control, Hot and Cold Spot, Auto / Manual Shuttering Password protected on-screen menu system for camera station configuration and diagnostics CAMERA / LENS C3000-2V36-T3>>[2C36] [W] *5 C3000-2V10-T3>>[2C10] [W] *5 Video Output 1.0 Vpk-pk CVBS into 75Ω; Colour PAL 50Hz [NTSC 60Hz] Image Sensor ¼ EXview HAD CCD 1 3 Super HAD CCD II Resolution >550TVL >530TVL S/N Ratio >50dB Zoom Range 36x zoom (up to 432x with digital zoom) 10x zoom (up to 120x with digital zoom) Minimum Illumination 1.4 lux 0.1 lux (with 1 3 sec integration) 0.01 lux mono (with 1 3 sec integration) 0.25 lux 0.015 lux (with 1 3 sec integration) 0.0004 lux mono (with 1 3 sec integration) Focal Length 3.4 to 122.4 mm 5.1 to 51 mm Angle of View 57.8 to 1.7 52 to 5.4 Aperture F1.6 to 4.5 F1.8 to 2.1 THERMAL IMAGER C3000-2V<<-T345 [2C<<] [W] *5 C3000-2V<<-T315 [2C<<] [W] *5 Image Sensor Amorphous Silicon Microbolometer Spectral Response 8 14 µm Thermal Sensitivity 50mK Refresh Rate <9Hz [25Hz] Resolution 384 x 288 Fixed Focal Length 45 mm 15 mm Angle of View 12 x 9.3 35 x 26 Human Detection* 3/4 ~1000 m >200 m [options] NOTE: *1 Dependant on equipment fitted. *2 Refer to Synectics for availability and compatibility with other control systems *3 Based on Johnson Criteria. *4 Actual range may vary depending on camera set-up, user experience, environmental conditions and type of monitor or display used. *5 >> replace with thermal camera module and << replace with day / night camera module. Synectic Systems sales@synecticsglobal.com synecticsglobal.com Specifications subject to change. E & OE. Copyright Synectic Systems Group Ltd, Synectic Systems, Inc. 2014. All Rights Reserved ISO 9001 Registered Quality Management 015 BS EN ISO 9001 CERTIFICATE No. 0956 Reference Numbers: 03GF0584_2 C3000T2S3/0414/A4 Iss 2
DATA SHEET TM COEX 2000 TriMode Series 6 Camera Station The COEX 2000 TriMode camera station 6 series has been specifically developed for marine applications and demanding environments. Combining the latest thermal imaging technology with a day / night (colour / mono) camera module the C2000 TriMode camera stations ensure unprecedented visual feedback in all light conditions. Utilised around the world to assist with: Pipeline monitoring Navigation during night time and foggy conditions Ice Detection Piracy Detection Man-overboard Safety Environmental Protection Intruder Detection Safety and Security Protection Even during daylight the C2000 TriMode can provide increased visibility over conventional camera stations with human detection at over 1100 m *3/4 COEX Series 6 camera stations are fitted with a 640 x 480 thermal imaging camera and a high resolution analogue day / night camera with removable IR cut filter. Features IP66 & IP67 rated completely protected against dust & water ingress, for the most extreme environments Electro-polished 316L stainless steel, for maximum corrosion resistance TriMode Operation Day (colour), Night (mono) and Thermal Imaging Low Voltage Operation Preset accuracy and repeatability of <0.05 Advanced Mechanical Design to minimise size and weight Pre-Heat Mode for safe start up in freezing conditions Smart Move Technology assists target acquisition and tracking Germanium and Toughened Glass Options Continuous Rotation [C] Absolute Positioning Integral Wiper [W] COEX MEWS Pressurised Wash System Synectics IP and Fibre Optic Transmission (via associated junction box) COEX Wall Mount Bracket COEX Range of Tilt Down Towers and accessories
COEX TM 2000 TriMode Series 6 Camera Station DATA SHEET Specifications CERTIFICATIONS / RATINGS Certifications / Ratings ENVIRONMENTAL Operating Temperature MECHANICAL Material Pan Operation Tilt Operation Mounting Dimensions (W x D x H) Pan Turning Circle Weight IP66 & IP67 to IEC 60529 CE Compliant to EMC and Low Voltage Directives LVD Directive: 2006/95/EC -45 C to +60 C Electro-polished 316L Stainless Steel Germanium and Toughened Glass, Thermostatically Operated Demister [Wiper for Day / Night View only] 360 rotation @ 0 to 42 /sec; Mechanical Limits; Programmable Soft-stops; Preset Positioning [Continuous Rotation] 180 rotation @ 0 to 21 /sec; Mechanical Limits; Programmable Soft-stops; Preset Positioning 4 x M8 x 1.25 tapped holes, equi-spaced on a 4 (101.6 mm) P.C.D. 412 x 310 x 375 mm Ø 626 mm 19 kg ELECTRICAL Power Requirements 24Vac 50 / 60Hz or 24Vdc (±10%) Power Consumption 92VA Maximum TELEMETRY Interface Protocols* 2 Day/Night Camera Thermal Camera OSD RS485 serial asynchronous data Synectics, Pelco, and other industry standard protocols available Pan, Tilt, Wash, Wipe, Aux1, [Aux2] and Aux in On / Off Selection of: Digital Zoom, BLC, Autofocus; Auto / Manual Selection of: Focus, Colour / Mono Operation, Frame Integration, White Balance Continuous Electronic Zoom, Multiple Colour Palettes (including Inverted), Multiple Contrast Display, Contrast and Level Control, Hot and Cold Spot, Auto / Manual Shuttering Password protected on-screen menu system for camera station configuration and diagnostics CAMERA / LENS C2000-2V36-T6>> [2C36] [W] *5 C2000-2V10-T6>> [2C10] [W] *5 Video Output 1.0 Vpk-pk CVBS into 75Ω; Colour PAL 50Hz [NTSC 60Hz] Image Sensor ¼ EXview HAD CCD 1 3 Super HAD CCD II Resolution >550TVL >530TVL S/N Ratio >50dB Zoom Range 36x zoom (up to 432x with digital zoom) 10x zoom (up to 120x with digital zoom) Minimum Illumination 1.4 lux 0.1 lux (with 1 3 sec integration) 0.01 lux mono (with 1 3 sec integration) 0.25 lux 0.015 lux (with 1 3 sec integration) 0.0004 lux mono (with 1 3 sec integration) Focal Length 3.4 to 122.4 mm 5.1 to 51 mm Angle of View 57.8 to 1.7 52 to 5.4 Aperture F1.6 to 4.5 F1.8 to 2.1 [options] THERMAL IMAGER C2000-2V<<-T650 [2C<<] [W] *5 C2000-2V<<-T625 [2C<<] [W] *5 Image Sensor Amorphous Silicon Microbolometer Spectral Response 8 14 µm Thermal Sensitivity 70mK [50mK] Refresh Rate <9Hz [25Hz] Resolution 640 x 480 Fixed Focal Length 50 mm 25 mm Angle of View 12.4 x 9.3 24.6 x 18.6 Human Detection* 3/4 ~1100 m ~560 m NOTE: *1 Dependant on equipment fitted. *2 Refer to Synectics for availability and compatibility with other control systems *3 Based on Johnson Criteria. *4 Actual range may vary depending on camera set-up, user experience, environmental conditions and type of monitor or display used. *5 >> replace with thermal camera module and << replace with day / night camera module. Synectic Systems sales@synecticsglobal.com synecticsglobal.com Specifications subject to change. E & OE. Copyright Synectic Systems Group Ltd, Synectic Systems, Inc. 2014. All Rights Reserved ISO 9001 Registered Quality Management 015 BS EN ISO 9001 CERTIFICATE No. 0956 Reference Numbers: 03GF620_2 C2000T2S6/0414/A4 Iss 1
DATA SHEET TM COEX 2000 TriMode Series 3 Camera Station The COEX 2000 TriMode camera station 3 series has been specifically developed for marine applications and demanding environments. Combining the latest thermal imaging technology with a day / night (colour / mono) camera module the C2000 TriMode camera stations ensure unprecedented visual feedback in all light conditions. Utilised around the world to assist with: Navigation during night time and foggy conditions Ice Detection Piracy Detection Man-overboard Safety Environmental Protection Intruder Detection Safety and Security Protection Even during daylight the C2000 TriMode can provide increased visibility over conventional camera stations with human detection at over 1100 m *3/4 COEX Series 3 camera stations are fitted with a 384 x 288 analogue thermal imaging camera and a high resolution analogue day / night camera with removable IR cut filter. Features IP66 & IP67 rated completely protected against dust & water ingress, for the most extreme environments Electro-polished 316L stainless steel, for maximum corrosion resistance TriMode Operation Day (colour), Night (mono) and Thermal Imaging Low Voltage Operation Preset accuracy and repeatability of <0.05 Advanced Mechanical Design to minimise size and weight Pre-Heat Mode for safe start up in freezing conditions Smart Move Technology assists target acquisition and tracking Germanium and Toughened Glass Options Continuous Rotation [C] Absolute Positioning Integral Wiper [W] COEX MEWS Pressurised Wash System Synectics IP and Fibre Optic Transmission (via associated junction box) COEX Wall Mount Bracket COEX Range of Tilt Down Towers and accessories
COEX TM 2000 TriMode Series 3 Camera Station DATA SHEET Specifications CERTIFICATIONS / RATINGS Certifications / Ratings ENVIRONMENTAL Operating Temperature MECHANICAL Material Pan Operation Tilt Operation Mounting Dimensions (W x D x H) Pan Turning Circle Weight *1 IP66 & IP67 to IEC 60529 CE Compliant to EMC and Low Voltage Directives LVD Directive: 2006/95/EC -45 C to +60 C Electro-polished 316L Stainless Steel Germanium and Toughened Glass, Thermostatically Operated Demister [Wiper for Day / Night View only] 360 rotation @ 0 to 42 /sec; Mechanical limits; Programmable soft-stops; Preset Positioning [Continuous Rotation] 180 rotation @ 0 to 21 / sec; Mechanical Limits; Programmable Soft-stops; Preset Positioning 4 x M8 x 1.25 tapped holes, equi-spaced on a 4 (101.6 mm) P.C.D. 412 x 310 x 375 mm Ø 626 mm 19 kg ELECTRICAL Power Requirements 24Vac 50 / 60Hz or 24Vdc (±10%) Power Consumption 92VA Maximum TELEMETRY Interface Protocols Day / Night Camera Functions* 2 Thermal Camera OSD RS485 serial asynchronous data Synectics, Pelco, and other industry standard protocols available Pan, Tilt, Wash *2, Wipe *2 Aux1, [Aux2] and Aux in On / Off Selection of: Digital Zoom, BLC, Autofocus Auto / Manual Selection of: Focus, Colour / Mono Operation, Frame Integration, White Balance Continuous Electronic Zoom, Multiple Colour Palettes (including Inverted), Multiple Contrast Display, Contrast and Level Control, Hot and Cold Spot, Auto / Manual Shuttering Password protected on-screen menu system for camera station configuration and diagnostics CAMERA / LENS C2000-2V36-T3>> [2C36] [W] *5 C2000-2V10-T3>> [2C10] [W] *5 Video Output 1.0 Vpk-pk CVBS into 75Ω; Colour PAL 50Hz [NTSC 60Hz] Image Sensor ¼ EXview HAD CCD 1 3 Super HAD CCD II Resolution >550TVL >530TVL S/N Ratio >50dB Zoom Range 36x zoom (up to 432x with digital zoom) 10x zoom (up to 120x with digital zoom) Minimum Illumination 1.4 lux 0.1 lux (with 1 3 sec integration) 0.01 lux mono (with 1 3 sec integration) 0.25 lux 0.015 lux (with 1 3 sec integration) 0.0004 lux mono (with 1 3 sec integration) Focal Length 3.4 to 122.4 mm 5.1 to 51 mm Angle of View 57.8 to 1.7 52 to 5.4 Aperture F1.6 to 4.5 F1.8 to 2.1 [options] THERMAL IMAGER C2000-2V<<-T345 [2C<<] [W] *5 C2000-2V<<-T315 [2C<<] [W] *5 Image Sensor Amorphous Silicon Microbolometer Spectral Response 8 14 µm Thermal Sensitivity 50mK Refresh Rate <9Hz [25Hz] Resolution 384 x 288 Fixed Focal Length 45 mm 15 mm Angle of View 12 x 9.3 35 x 26 Human Detection* 3/4 ~1000 m >200 m NOTE: *1 Dependant on equipment fitted. *2 Refer to Synectics for availability and compatibility with other control systems *3 Based on Johnson Criteria. *4 Actual range may vary depending on camera set-up, user experience, environmental conditions and type of monitor or display used. *5 >> replace with thermal camera module and << replace with day / night camera module. Synectic Systems sales@synecticsglobal.com synecticsglobal.com Specifications subject to change. E & OE. Copyright Synectic Systems Group Ltd, Synectic Systems, Inc. 2014. All Rights Reserved ISO 9001 Registered Quality Management 015 BS EN ISO 9001 CERTIFICATE No. 0956 Reference Numbers: 03GF0583_2 C2000T2S3/0414/A4 Iss 1