Ring Instrumentation and Controls

Similar documents
HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

QUALITROL QTMS Transformer Monitoring System

CDD4 Duct Carbon Dioxide Transmitter

LHe/LN2 Cryogenic Probe Station

General. Remote I/O A4/1.

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

Product Family: Electro Mechanical Relays Number: AN-LC-008

VersaMax Micro and Nano Technical Product Presentation

INSTALLATION INSTRUCTIONS

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

Model HM-535 Power Supply Installation and Service Instructions

A Guide to Management of Change -

CDD4 Series Room CO2 Transmitter Installation Instructions

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

SECTION THERMAL UTILITY METERING INTERFACE

HMISCU6B5. Main. 60 right 40 top 60 bottom

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Intrinsically Safe Barriers

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

CSI 9330 Vibration Transmitter

General information. Display. Supply voltage. Input current

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

General information. Display. Supply voltage. Input current

MGate 5102-PBM-PN Series

General information. Display. Supply voltage. Input current

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

Providing the missing piece in your Condition Based Monitoring platform

VersaPoint I/O. Proficy Machine Edition. Publication Reference Chart

Smoke Detection and AC Power Distribution / Interruption for NOνA Near Detector Surface Building Electronics Racks

GRASSO SYSTEM CONTROL

General information. Display. Supply voltage

Scientech Universal PLC Platform. Features. New

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

HMISCU8B5 5 7 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Deaerator and Surge Tank Control

CDD Carbon Dioxide Transmitter

General information. Display. Supply voltage

APPLICATION GUIDE. Interface Modules IM Series.

Siemens tiastar TM Motor Control Center (MCC)

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

To demonstrate wide range of experiments, applications and advanced control techniques using industry standard instrumentation and controls.

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

General information. Display. Supply voltage

Improving monitoring and control hardware cost at Totten Mine

Server/ Engineering Station. Filed Instrument. Filed Instrument. Filed Instrument. Switches. Fig1: Scheme for micro PLC to Master PLC Interface

FP_D.5_EGAT_THE REVAMP OF PARTIAL UPGRADE EXCITATION CONTROL SYSTEM BY USING THE EGAT s INNOVATION (EGAT-AVR)

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

LC2300 Level Controller Installation and Maintenance Instructions

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

Solutions for Fossil Fuel Energy

Discrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

4-step Chiller and Heat Pump Controller

Practical Programmable Logic Controllers (PLCs) for Automation and Process Control. Contents

Twickenham. Scientific Instruments. The Transfer Control Module (TCM) Instruction manual, release 1.1

General information. Display. Supply voltage. Input current

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

SX90 Process Controller

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

MCM MACHINE CONDITION MONITORING.

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

General information. Display. Supply voltage. Input current. Encoder supply. Output current

FEATURES DESCRIPTION FEATURES

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Hall D Cryotarget Controls

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Control systems. Efficient room control

TPE 1464 Series Pressure Transducer

General information. Display. Supply voltage. Input current. Encoder supply. Output current

RTD. Process Calibrator. User s MANUAL. PDF created with pdffactory Pro trial version

Exercise 5-1. Electrical Circuit and Panel EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Detailed electrical schematic

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Self-Powered Wireless Instrumentation

General information. Display. Supply voltage. Input current

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

General information. Display. Supply voltage. Input current

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Product Specifications

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

NetBiter I/O Extender User Manual

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Transcription:

Chapter 14 Ring Instrumentation and Controls This chapter describes the technical design of the g-2 cryogenic and vacuum control system and other process systems supporting the experiment. This control system will be a copy of the typical Siemens S7-400 PLC (Programmable Logic Controller) control system as deployed by the Fermilab PPD/Mechanical Department. The g-2 cryogenic and vacuum system will be located on the Muon campus in the MC1 building and Muon g-2 experimental hall. This area is classified as ODH Class 0 area and has several large cryogenic and gas components. Cryogens include Liquid Helium and Liquid Nitrogen. This cryogenic system has approximately 600 electronic input sensing devices and 100 output devices. Input devices include temperature sensors, pressure transmitters, vacuum gages, level probes, and strain gages. Output devices include solenoid valves, control valves, and vacuum valves and pumps. All electronic and electrical control system equipment is air cooled and does not require any forced air cooling or water cooling. Cabinet air vents are provided for certain devices where appropriate. The control system equipment components are all commercially available products which are UL listed. The cryogenic control system has been designed and will be built following all the required rules and standards such as the NEC and NFPA 70E. All premises wiring is to be installed by Fermi Electrical contractors and licensed electricians. 14.1 Cryogenic/Vacuum Control System The G-2 process controls also known as the slow controls will have a Siemens S7-400 PLC with S7-300 associated I/O modules as the master control system. There will be sub systems controlled by other PLCs that will report to the Master PLC. The Master PLC will also provide system data and interlocks to these subordinate PLC systems. The DAQ control system known as MIDAS will also be provided data and interlocks from this S7-400 master PLC. See the Control System Architecture drawing shown in figure 14.1. 14.1.1 Piping and Instrumentation Diagram The piping and instrumentation diagram is shown in figure 14.2. 425

426 RING INSTRUMENTATION AND CONTROLS Figure 14.1: G-2 Controls System Architecture. 14.1.2 Programmable Logic Controller The g-2 cryogenic/vacuum system will be controlled by a Siemens S7-400 PLC with S7-300 associated I/O modules (or equivalent industrial controls system) networked on a Profibus

CHAPTER 14 427 Figure 14.2: The G-2 Piping and Instrumentation Diagram.

428 RING INSTRUMENTATION AND CONTROLS network. This PLC system will be programmed using the Siemens S7 engineering programming software (or equivalent software meeting IEC 61131-3 standard). Siemens S7-400 PLC systems are currently in use at several Fermilab projects: LAPD, LBNE 35 Ton, Super CDMS, Microboone, and NML/CMTF. 14.1.3 Instrumentation The g-2 cryogenic/vacuum system instrumentation will consist of commercial transducers, transmitters, valves, positioners, strain gauges, and thermometers. These commercial devices will have conventional signals that conform to the normal PLC module input and output signal ranges. The locations of these devices are given in reference [1]. PSIG, PSIA, and differential pressures will be measured by commercial transmitters that provide a 4-20 ma signal when available. A voltage range of 0-10 VDC will be an alternate range. Temperature will be measured by a Platinum 100 ohm RTD when possible, because the PLC system can read them directly. There are a number of Silicon diodes in the detector which will be measured by a Lakeshore temperature transmitter that provides a 4-20mA output to the PLC system. Any Cernox RTDs will also be measured with a Lakeshore temperature transmitter that provides a 4-20 ma signal to the PLC. 14.1.4 Strain Gauges G-2 has strain gauges (full bridge style) mounted on the straps and radial stops, which are inside the cryostats and so are at cryogenic temperatures. Room temperature strain gauges are also mounted on the outer cryostat pushrods. Strain gauges will be used during commissioning to make sure that the forces agree with expectation. It is not necessary to read out all these strain gauges during regular experiment operation. All strain gauges (4 wires per gauge) will be connected to a patch panel in the control room. A select subset of strain gauges will be read out with 2 Vishay D4 units, which will be connected to a Windows PC via USB. 1 Each Vishay D4 unit can read out 4 full-bridge strain gauges. A full description can be found in reference [2]. 14.1.5 Vacuum Pump Control Vacuum Pump stations are used to maintain various vacuum systems. These stations can be controlled by the Master PLC system using discrete I/O. Each pumping station also has isolation control valves. The vacuum pumps for the ring cryostats and beam vacuum chambers are described in tables 14.1.5 and 14.1.5. The pump station remote control interface is shown in figure 14.3. 14.1.6 Programmable Logic Controller Input/Output The g-2 cryogenic/vacuum system will be controlled by a Siemens S7-400 PLC with S7-300 associated I/O modules (or equivalent industrial controls system) networked on a Profibus 1 Any strain gauge can be read out by manually plugging it into one of the Vishay D4 units.

CHAPTER 14 429 Table 14.1: Summary of vacuum pumps for the ring cryostats. The Turbo Molecular Pumps (TMPs) pump helium and air to maintain the cryostat insulating vacuum pressure at less than 1E-4 Torr. Pump Type Location Roots Blower Lead Pot 1 Backup to Roots Blower Upper 11 Position TMP Upper Lead Pot 2 TMP Upper 7 TMP Lower 7 TMP Lower 11 TMP Outer 7 TMP Outer 11 TMP Lower 3 Table 14.2: Summary of vacuum pumps for the ring beam vacuum chambers. The Turbo Molecular Pumps (TMPs) pump helium and air to maintain the cryostat insulating vacuum pressure at less than 1E-7 Torr. Pump Type Location TMP Chamber 6 TMP Chamber 12 TMP Chamber 8 (contains straw tracker) TMP Chamber 10 (contains straw tracker) TMP Chamber 2 (contains trolley drive) Cryo Pump Chamber 3 Cryo Pump Chamber 9 network. The I/O modules convert digital PLC values to the field instrumentation and visa-versa. Table 14.1.6 summarizes the input/outputs. 14.1.7 Human Machine Interface Human Machine Interface (HMI) controls will be provided through GEFANUC s ifix software. ifix connects to the S7-400 through Private Ethernet using an Industrial Gateway Server (IGS) driver included with the ifix software. ifix will handle all operator security, computer alarming, and remote operator controls via the PPD-iFIX server. ifix will also provide historical data through the PPD-iFIX historian. This historical data will be viewable in ifix picture displays or on the web through the ifix Proficy portal server. An example of an HMI for the LAPD experiment is shown in figure 14.4.

430 RING INSTRUMENTATION AND CONTROLS Figure 14.3: The Pump Station Remote Control Interface. 14.1.8 Helium Refrigerator Controls The Helium liquefier system controls were designed and built by the Accelerator Division cryogenic department. This control system also consists of a Siemens S7-400 PLC as the core controller. This system will easily interface with the G-2 experiment master Siemens S7-400. The AD cryo S7-400 and the G-2 S7-400 PLC will share a private network. This private network will allow PLC variables to be shared in either direction and also allow the ifix HMI to control the Helium refrigerator components. 14.1.9 System Communication and Data Sharing Data will need to be shared between multiple systems outside of the Siemens master PLC system. There are a number of methods and protocols that allow data sharing such as OPC, MODBUS TCP/IP, SQL, and others. The Helium refrigerator communication will be

CHAPTER 14 431 Subsystem Table 14.3: Summary of types of input/outputs connections to the PLC 4-20mA 0-10 VDC Analog inputs Silicon Diode inputs RTD (PT100 s) inputs Discrete (digital) 24 VDC inputs Discrete (digital) 24VDC outputs Magnet Cryo 23 68 10 20 8 7 Inflector Cryo 10 10 10 10 10 4 Cryostat Vacuum 10 0 10 40 40 2 ODH 10 0 2 10 6 2 LCW/Chilled Water 10 0 10 10 10 4 Storage Ring 7 0 7 30 30 4 Vacuum Yoke/Pole 10 0 10 10 10 10 Tracker 10 0 10 10 10 10 DC System 10 0 10 10 10 4 Subtotal 100 78 79 150 134 47 Total 588 24 VDC Analog outputs through the private network that links the G-2 Master S7-400 PLC and the AD cryogenic control system S7-400 PLC. The DAQ system HMI is known as MIDAS. The most likely communication path between the G-2 Master Siemens S7-400 PLC and MIDAS will be OPC over Ethernet, but SQL is also possible. The magnet DC control system will be run by a Beckhoff CX5000 PLC. The Beckhoff CX 5000 PLC will be linked to the G-2 Master Siemens S7-400 PLC through PROFINET which is an industrial protocol supported by both systems 14.2 Life Safety and System Reliability ODH System The ODH system will utilize six MSA O2 heads. Two O2 heads will be located near the ceiling of the g-2 experimental hall, with another four O2 sensors located near the floor of the hall. There will be an ODH warning horn and strobe lamp. These will be centrally located in the hall. There will be two ventilation fans used to maintain the ODH risk class zero status in the g-2 hall. One fan will exhaust air out of the g-2 hall at the ceiling venting it outside. The second fan will supply fresh air to the building near the floor outside of the rings. These fans are controlled by the S7 PLC and can also be run locally using a switch mounted at the fan controls. The ODH system is hardwired to both fans such that during an ODH alarm both fans run. The O2 Sensors are MSA model A-UltimaX-PL-A-14-03D2-0000-100 and have a span of 0-25%. Each O2 sensor is to be wired to an MSA electronic controller

432 RING INSTRUMENTATION AND CONTROLS Figure 14.4: Human Machine Interface for the LAPD experiment. which provides an analog output signal wired to the S7 PLC. This MSA electronic unit also provides relays which have three O2 level alarms thresholds, 18.5%, 18%, and 17.5%. The relay output that is set at 18.5% is wired directly to the ODH warning horns and strobe lamps located in MC1 and FIRUS. The MSA electronic unit also provides a trouble relay output which is also wired to the PLC and FIRUS. The trouble output is wired in a failsafe manner, such that loss of power or blown fuse to the ODH controls will generate a trouble alarm. The MSA equipment is wired directly to its own self-contained control circuitry in its own enclosure. This self-contained enclosure has its own power supply which is independent of the PLC control system, allowing the ODH system to function independently of the PLC control system. The power for this ODH system comes from a U.P.S. (Uninterruptible Power Supply). 14.2.1 Uninterruptible Power Supply (U.P.S.) The control system U.P.S. is to be a commercial unit such as those manufactured by Powerware. The U.P.S. input power is fed from a premises powered outlet using the U.P.S. input line cord. This U.P.S. system will be natural gas generator backed. The diesel generator will be auto start with auto switchover on commercial power loss. There will be other loads on this generator as well. The U.P.S. has standard outlets located on the rear of the cabinet. An APC surge protector is located on the U.P.S. and its input power cord is plugged into

CHAPTER 14 433 the U.P.S output outlets. All relevant control system loads are plugged into the APC surge protector output outlets. 14.2.2 PLC Reliability and Redundancy Siemens SIMATIC (S7 PLC and ET200M I/O modules) components meet all relevant international standards and are certified accordingly. Temperature and shock resistance are defined in the SIMATIC quality guidelines, as are vibration resistance or electromagnetic compatibility. The Siemens S7 PLC system equipment can be redundant at many different levels, from the PLC CPU (Hot Backup) to the module and instrument level. We expect to have the redundancy at the PLC level.

References [1] Documentation of Instruments in the g-2 Cryostats, g-2 DocDB note 1653. [2] Strain Gauge Configuration and Cost Estimate, g-2 DocDB note 861. [3] Electrical Design Standards for Electronics to be used in Experiment Apparatus at Fermilab. [4] EED/Infrastructure Doc. No:H011228A. 434