PRCM Series Cylindrical Connector Type Proximity Sensor Features Improved the noise immunity with dedicated IC Built-in reverse polarity protection circuit (DC -wire type) Built-in surge protection circuit Built-in over-current protection circuit (DC type) IP67 protection structure (IEC standard) for connector part Replaceable for micro switches and limit switches Please read Safety Considerations in operation manual before using. Specifications DC -wire type Model PRCMT-DO PRCMT-DC PRCMT-DO-I PRCMT-DC-I PRCMT-DO PRCMT-DC PRCMT-DO-I PRCMT-DC-I PRCMT8-DO PRCMT8-DC PRCMT8-DO-I PRCMT8-DC-I PRCMT8-8DO PRCMT8-8DC PRCMT8-8DO-I PRCMT8-8DC-I PRCMT0-0DO PRCMT0-DO PRCMT0-0DC PRCMT0-DC PRCMT0-0DO-I PRCMT0-DO-I PRCMT0-0DC-I PRCMT0-DC-I distance mm mm mm 8mm 0mm mm Hysteresis Max. 0% of sensing distance Standard sensing mm (iron) 8 8 mm (iron) mm (iron) 0 0 mm (iron) mm (iron) Setting distance 0 to.mm 0 to.8mm 0 to.mm 0 to.6mm 0 to 7mm 0 to 0.mm Power supply (operating voltage) -VDCᜡ (0-DCᜡ) Leakage current Max. 0.6mA Response frequency.khz 00Hz 0Hz 00Hz 00Hz Residual voltage Max..V Affection by Temp. Max. ±0% for sensing distance at ambient temperature 0 Control output to 00mA Insulation resistance Over 0MΩ (at 0DC megger) Dielectric strength,0ac 0/60Hz for minute Vibration mm amplitude at frequency 0 to Hz (for min) in each X, Y, Z directions for hours Shock 00m/s² (approx. 0G) in each X, Y, Z directions for times : Red LED Ambient - to 70, storage: -0 to 80 Environment temperature Ambient humidity to 9%RH, storage: to 9%RH Protection circuit Surge protection circuit, Over-current protection Protection structure Material Approval IP67 (IEC standard) Case/Nut: Nickel plated brass, Washer: Nickel plated iron, surface: Polybutylene terephthalate ᜢ Weight Approx. 8g (approx. 6g) Approx. 60g (approx. 8g) Approx. g (approx. g) : The response frequency is the average value. The standard sensing is used and the width is set as times of the standard sensing, / of the sensing distance for the distance. : The weight includes packaging. The weight in parenthesis in for unit only. There is IEC standard connector cable. Refer to the G-6 about IEC standard connector wires and specifications. Environment resistance is rated at no freezing or condensation. D-8
Cylindrical Connector type Specifications DC -wire type Model AC -wire type PRC-DN PRC-DP PRC-DN PRC-DP PRC-DN PRC-DP PRC-DN PRC-DP PRCM8-DN PRCM8-DP PRCM8-DN PRCM8-DP PRCML8-DN PRCML8-DP PRCML8-DN PRCML8-DP PRCM8-8DN PRCM8-8DP PRCM8-8DN PRCM8-8DP PRCML8-8DN PRCML8-8DP PRCML8-8DN PRCML8-8DP PRCM0-0DN PRCM0-0DP PRCM0-0DN PRCM0-0DP PRCML0-0DN PRCML0-0DP PRCML0-0DN PRCML0-0DP distance mm mm mm 8mm 0mm mm Hysteresis Max. 0% of sensing distance PRCM0-DN PRCM0-DP PRCM0-DN PRCM0-DP PRCML0-DN PRCML0-DP PRCML0-DN PRCML0-DP Standard sensing mm (iron) 8 8 mm (iron) mm (iron) 0 0 mm (iron) mm (iron) distance 0 to.mm 0 to.8mm 0 to.mm 0 to.6mm 0 to 7mm 0 to 0.mm Power supply (operating voltage) -VDCᜡ (0-DCᜡ) Current consumption Max. 0mA Response frequency.khz 00Hz 00Hz 0Hz 00Hz 00Hz Residual voltage Max..V Affection by Temp. Max. ±0% for sensing distance at ambient temperature 0 Control output Insulation resistance Dielectric strength Vibration Shock Protection circuit Max. 00mA Over 0MΩ (at 0DC megger),0ac 0/60Hz for minute mm amplitude at frequency 0 to Hz (for min) in each X, Y, Z directions for hours 00m/s² (approx. 0G) in each X, Y, Z directions for times : Red LED Ambient temperature - to 70, storage: -0 to 80 Ambient humidity Protection structure Material Approval to 9%RH, storage: to 9%RH Surge protection circuit, Reverse polarity protection circuit, Over-current protection IP67 (IEC standard) Case/Nut: Nickel plated brass, Washer: Nickel plated iron, surface: Polybutylene terephthalate ᜢ Weight Approx. 8g (approx. 6g) Model PRC-AO PRC-AC PRC-AO PRC-AC PRCM: Approx. 6g (approx. 9g) PRCML: Approx. 8g (approx. 7g) PRCM8-AO PRCM8-AC PRCML8-AO PRCML8-AC PRCM8-8AO PRCM8-8AC PRCML8-8AO PRCML8-8AC PRCM: Approx. 6g (approx. g) PRCML: Approx. 8g (approx. 69g) PRCM0-0AO PRCM0-0AC PRCML0-0AO PRCML0-0AC distance mm mm mm 8mm 0mm mm Hysteresis Max. 0% of sensing distance PRCM0-AO PRCM0-AC PRCML0-AO PRCML0-AC Standard sensing mm (iron) 8 8 mm (iron) mm (iron) 0 0 mm (iron) mm (iron) distance 0 to.mm 0 to.8mm 0 to.mm 0 to.6mm 0 to 7mm 0 to 0.mm Power supply (operating voltage) Leakage current Response frequency Residual voltage 00-ACᜠ (8-6VACᜠ) Max..mA 0Hz Max. Affection by Temp. Max. ±0% for sensing distance at ambient temperature 0 Control output to 0mA to 00mA Insulation resistance Over 0MΩ (at 0DC megger) Dielectric strength,0ac 0/60Hz for minute Vibration mm amplitude at frequency 0 to Hz (for min) in each X, Y, Z directions for hours Shock 00m/s² (approx. 0G) in each X, Y, Z directions for times : Red LED Environment Environment Ambient temperature - to 70, storage: -0 to 80 Ambient humidity to 9%RH, storage: to 9%RH Protection circuit Surge protection circuit Protection structure IP67 (IEC standard) Insulation type Double insulation or reinforced insulation (Mark:, dielectric strength between the measuring input part and the power part: kv) Material Approval Case/Nut: Nickel plated brass, Washer: Nickel plated iron, surface: Polybutylene terephthalate ᜢ Weight Approx. g (approx. 0g) PRCM: Approx. 66g (approx. g) PRCML: Approx. 78g (approx. 66g) PRCM: Approx. g (approx. g) PRCML: Approx. 9g (approx. 8g) : The response frequency is the average value. The standard sensing is used and the width is set as times of the standard sensing, / of the sensing distance for the distance. : The weight includes packaging. The weight in parenthesis in for unit only. Environment resistance is rated at no freezing or condensation. (A) Photoelectric (B) Fiber Optic (C) Door/Area (D) Proximity (E) Pressure (F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature (I) SSRs / Power (J) Counters (K) Timers (L) Panel (M) Tacho / Speed / Pulse (N) Display Units (O) Sensor (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & (R) Graphic/ Logic Panels (S) Field Network Devices (T) Software D-9
PRCM Series Dimensions PRC-D / PRCMT-D (-I) Ø.8 7. PRC-D / PRCMT-D (-I) Ø.8 7 7. (unit: mm) PRCM8-D / PRCMT8-D (-I) Ø9. 9. PRCM8-8D / PRCMT8-8D (-I) Ø9.8 0 9 M8 M8 PRCM0-0D / PRCMT0-0D (-I) PRCM0-D / PRCMT0-D (-I) Ø 6.8 Ø 6.8 8 0 8 M0. M0. PRC-A Ø 7 7.8 8. PRC-A Ø 7 7 7.8. PRCM8-A Ø9.8 60.6 PRCM8-8A Ø9 0 60.. PRCM0-0A Ø 8 6.8 PRCM0-A Ø 0 8 6.8 M0. M0. PRCML8-D / PRCML8-A Ø9 87. 6. PRCML8-8D / PRCML8-8A Ø9 0 86.8 M8 M0. PRCML0-0D / PRCML0-0A PRCML0-D / PRCML0-A Ø 8.8 Ø 60 0 8.8 0 M0. M0. D-0
Cylindrical Connector type Control Output Diagram and DC -wire type DC -wire type Main circuit AC -wire type Operating (red LED) Presence Nothing Return ON OFF N.O. N.C. NPN output type Main circuit 0kΩ Black (brown-black) Output voltage (black-blue) Operating (red LED) Presence None Return H L ON OFF N.O. N.C. (A) Photoelectric (B) Fiber Optic (C) Door/Area (D) Proximity (E) Pressure Main circuit 00- AC 0/60Hz Operating (red LED) Presence None Return ON OFF N.O. The number in a circle is pin no. of connector. N.C. PNP output type Main circuit 0kΩ Black (black-blue) Output voltage (black-blue) Operating (red LED) N.O. Presence None Return H L ON OFF N.C. (F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature (I) SSRs / Power Wiring Diagram DC -wire type (standard type) Normally Open (N.O.) / Normally Closed (N.C.) DC -wire type (IEC standard type) Normally Open (N.O.) Normally Closed (N.C.) (J) Counters (K) Timers (L) Panel (M) Tacho / Speed / Pulse Pin, are not used terminals. For DC -wire type connector cable, it is available to use with black wire (-V DC) and blue wire ()., of N.O. type and, of N.C. type are not used terminals. The pin arrangement of connector applying IEC standard is being developed. Please attach "I" at the end of the name of standard type for purchasing the IEC standard product. E.g.) PRCMT-DO-I The connector cable for IEC standard is being developed. Please attach "I' at the end of the name of standard type. E.g.) CID--I, CLD--I (N) Display Units (O) Sensor (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & DC -wire type AC -wire type NPN output type Black PNP output type Black Please fasten the cleat of connector not to shown the thread. (0.9 to 0.9N. m) Normally Open (N.O.) / Normally Closed (N.C.) ~ In AC inductive type, and, and are connected inside of the connector cable. ~ (R) Graphic/ Logic Panels (S) Field Network Devices (T) Software Please fasten the vibration part with PTFE tape. Refer to the G-6 about IEC standard connector wires and specifications. D-
PRCM Series Distance Feature Data by Target Material and Size Detecting Method distance (X) d One side length PRCMT-D, PRC-A.0.0 PRCMT-D, PRC-A.00 Iron(SS0) Iron(SS0).0.0 0.0 Stainless steel 6 (SUS6).00.0.0 0.0 Stainless steel 6 (SUS6) 8 0 8 0 0 0 0 60 70 7 80 90 00 8 0 8 0 0 0 0 60 70 7 80 90 00 PRCMT8-D, PRCM(L)8-A PRCMT8-8D, PRCM(L)8-8A.00.00 Iron(SS0) Stainless steel 6 (SUS6) 9.00 7.00.00.00 Iron(SS0) Stainless steel 6 (SUS6) 8 0 8 0 0 0 0 60 70 7 80 90 00 8 0 8 0 0 0 0 60 70 7 80 90 00 PRCMT0-0D, PRCM(L)0-0A PRCMT0-D, PRCM(L)0-A Iron(SS0) Iron(SS0).00 Stainless steel 6 (SUS6).00 Stainless steel 6 (SUS6) 8 0 8 0 0 0 0 60 70 7 80 90 00 8 0 8 0 0 0 0 60 70 7 80 90 00 D-
Cylindrical Connector type Distance Feature Data by Target Material and Size Detecting Method distance (X) d One side length (A) Photoelectric (B) Fiber Optic.0.0 0.0 PRCM(L)-D 8 0 8 0 0 0 0 60 70 7 80 90 00 Iron(SS0) Stainless steel 6 (SUS6) PRC-D.0.00.0.00.0.0 0.0 8 0 8 0 0 0 0 60 70 7 80 90 00 Iron(SS0) Stainless steel 6 (SUS6) (C) Door/Area (D) Proximity (E) Pressure (F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature PRCM(L)8-D PRCM(L)8-8D (I) SSRs / Power.00.00 8 0 8 0 0 0 0 60 70 7 80 90 00 Iron(SS0) Stainless steel 6 (SUS6) 9.00 7.00.00.00 8 0 8 0 0 0 0 60 70 7 80 90 00 Iron(SS0) Stainless steel 6 (SUS6) (J) Counters (K) Timers (L) Panel (M) Tacho / Speed / Pulse (N) Display Units PRCM(L)0-0D PRCM(L)0-D (O) Sensor.00 Iron(SS0) Stainless steel 6 (SUS6).00 Iron(SS0) Stainless steel 6 (SUS6) (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & (R) Graphic/ Logic Panels (S) Field Network Devices 8 0 8 0 0 0 0 60 70 7 80 90 00 8 0 8 0 0 0 0 60 70 7 80 90 00 (T) Software D-
PRCM Series Distance Feature Data by Parallel (Left/Right) Movement Detecting Method area (Y) distance (X) PRCMT-D /D, PRC-A /A.0 PRCMT8-D /8D, PRCM(L)8-A /8A 0.8 PRCMT0-0D /D, PRCM(L)0-0A /A.0..0 0.6.0..0 0..0.7...0 0.7 0. 0. 0.0 8.0 6.0 0. 0..0 0. 0..0.0.0.0 0.0 0..0..0 area Y (mm) 0. 0.8 0.6 0. 0. 0.0 0. 0. 0.6 0.8 area Y (mm).0 0.0.0 0.0.0 0.0.0 0.0.0 0.0 area Y (mm) PRCMT-D, PRC-A PRCMT-D, PRC-A PRCMT8-D, PRCM(L)8-A PRCMT8-8D, PRCM(L)8-8A PRCMT0-0D, PRCM(L)0-0A PRCMT0-D, PRCM(L)0-A PRCM(L)-D PRC-D.0 PRCM(L)8-D /8D 0.8 PRCM(L)0-0D /D.0..0 0.6.0..0 0..0.7...0 0.7 0. 0. 0.0 8.0 6.0 0. 0..0 0. 0..0.0.0 0.0.0.0 area Y (mm) 0. 0.0.0 0.0 0. 0.0 area Y (mm).0 0.0.0 0.0.0 0.0.0 0.0.0 0.0 area Y (mm) PRCM(L)-D PRC-D PRCM(L)8-D PRCM(L)8-8D PRCM(L)0-0D PRCM(L)0-D D-
Cylindrical Connector type Proper Usage connections + + - POWER - VDC < DC -wire type & AC -wire type > < DC -wire type > < AC -wire type > When using DC or AC -wire type proximity sensor, the load must be connected, otherwise internal components may be damaged. The load can be connected to either wire. connections AC -wire type DC -wire type Bleeder resistor(r) AC: Min. 0kΩ W AC: Min. 9kΩ 0W Bleeder resistor(r) Vs + Vs - 00- AC 0/60Hz It may cause return failure of load by residual voltage. If the load current is under ma, please make sure the residual voltage is less than the return voltage of the load by connecting a bleeder resistor in parallel with the load as shown in the diagram. Vs R I (kω) [ I:Action current of load, R:Bleeder resistance, P:Permissible power] Please make the current on proximity sensor smaller than the return current of load by connecting a bleeder resistor in parallel. W value of Bleeder resistor should be bigger for proper heat dissipation. Vs R Io-Ioff (kω) Vs: Power supply, Ioff: Return current of load, Vs P > R (W) Vs P > R (W) Io: Min. action current of proximity sensor, P : Number of Bleeder resistance watt [ ] Mutual-interference & Influence by surrounding metals When several proximity sensors are mounted close to one another a malfunction of the may be caused due to mutual interference. Therefore, be sure to keep a minimum distance between the two sensors as below chart indicates. (A) Photoelectric (B) Fiber Optic (C) Door/Area (D) Proximity (E) Pressure (F) Rotary Encoders (G) Connectors/ Connector Cables/ Sensor Distribution Boxes/Sockets (H) Temperature (I) SSRs / Power (J) Counters (K) Timers (L) Panel (M) Tacho / Speed / Pulse (N) Display Units Item Model PRCMT-D PRC-D PRC-A A Face to Face l PRCMT-D PRC-D PRC-A PRCMT8-D PRCM(L)8-D PRCM(L)8-A l Ød Parallel B When sensors are mounted on metallic panel, it is required to protect the sensors from being affected by any metallic object except. Therefore, be sure to provide a minimum distance as below chart indicates. PRCMT8-8D PRCM(L)8-8D PRCM(L)8-8A l m n PRCMT0-0D PRCM(L)0-0D PRCM(L)0-0A A 0 8 60 90 B 6 6 60 90 l 0 0 0 Ød 6 8 0 90 m 6 0 n 8 6 7 90 (unit: mm) PRCMT0-D PRCM(L)0-D PRCM(L)0-A (O) Sensor (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & (R) Graphic/ Logic Panels (S) Field Network Devices (T) Software D-