DP500IP 1AC/ DP500IP 3AC Manual

Similar documents
Power supply CP-C 24/5.0

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

MINI-PS AC/10-15DC/8

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

PV Rapid Shutdown device

QUINT-PS/ 1AC/24DC/ 5

STEP-PS/1AC/24DC/1.75

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Operating instructions Evaluation system for flow sensors VS / / 2013

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

QUINT-PS AC/24DC/10

Redundancy unit CP-A RU

Industrial motor controller for brushed DC motors 24 VDC

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Serial PROFIBUS Interface

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

High Power Electronic Gear Installation and operation Guide

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

QUINT-BUFFER/24DC/24DC/40

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

The LED display (1) turns green when the load is switched on.

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

RТTH DUAL ROOM SWITCH

Hardware Manual RM Display 2401

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

SINCOS. Linear Stepper Motor Power Stage. Manual 2066-A006 GB

Industrial motor controller for brushed DC motors 24 VDC

Operating instructions. Speed monitor D / / 2014

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Type ME43. Quickstart

Power supply CP-D 12/2.1 Primary switch mode power supply

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Industrial Power Supplies

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Power supply CP-E 48/1.25 Primary switch mode power supply

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

Power supply CP-E 24/0.75 Primary switch mode power supply

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

EC Series. Safety Guide

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

MC 11 EB-2 Power supply cabinet with external bus, AC version

Siemens Industrial s

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

QUINT-PS/ 1AC/24DC/20/CO

3700 SERIES USER MANUAL

Manual. The 24V single-channel circuit breaker system

Documentation. AL225x Connector-Box. Accessory for servo drives of the series AX5000 and AX2000. Version: Date:

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

PSR UC/ESAM4/3X1/1X2/B

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Blitzer Strobe. User Manual. Order code: EQLED366

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

PanelView Plus/VersaView CE Terminals and Display Modules

Masterswitch 25kW 230V-125A Automatic AC transfer switch

Installation Instructions

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

Flexoled FTP3HP RGB LED DMX Driver

50W 0-10V LED Driver with Smooth Dimming to 1%

TRIO-DIODE/12-24DC/2X10/1X20

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

SOLOdrive AC, 100W, DALI, 1 control channel, constant current, 4x 57V outputs, side feed, square metal

PSR DC/ESP4/2X1/1X2

icore Kiosk system Installation Guide

User Guide. Control Box. RoscoLED TM.

Power supply CP-E 24/10.0 Primary switch mode power supply

PHOENIX CONTACT - 07/2006

Rhino PSM Power Supplies. Operating Instructions

Hardware Manual RM Display 2501 S01..S04

IMPORTANT SAFETY INSTRUCTIONS

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

SMART-e Document Rev1

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

C9900-P223 and C9900-P224

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating instructions. Standstill monitor A / / 2011

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

RADEON /RADEON VE Getting Started...

PRO-1250D CT MID DIN rail three phase four wire energy meter.

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

Transcription:

DP500IP 1AC/ DP500IP 3AC Manual IP67 Power Supply

Content 1) General safety instructions... 4 2) Technical Data... 6 3) Installations... 6 4) Function and Signals... 7 5) Service Center / Rapair... 8 6) Notes... 9 2

Important Note: Only qualified personnel are allowed to use the device for specified application. Read the instruction manual carefully and pay attention to the safety instructions and manufacturers requirements in any case! Features Innovative enclosed IP67-power supply for professional OEM application Usage in rough environmental conditions possible Screw mounting (DIN-Rail adapter available on request Very high efficiency Low Standby-Power (< 0,8 Watt) LED power indicator High transient stability No inrush current, active PFC Compact mounting form 3

1) General safety instructions - The DP500IP-Power Supplies are cable linked, enclosed power supplies for industrial usage. The devices are especially suitable for usage in industrial machinery according to NFPA79. - When electrical devices are activated, certain parts are under dangerous voltage inevitably. - Improper handling of these devices can cause fatal injuries and substantial material damages. - Only qualified personnel are allowed to work on these devices. - The device may not be opened, otherwise the test-certificate as well as the warranty expires. All necessary connections and adjustment elements for operation are accessible from the outside. - In the USA and other valid countries the device must be installed in accordance with the NEC and the UL508 standard. - A separator to disconnect the power supply must be provided. - Before installation or work at the device, turn off the main switch and secure against unauthorized switching. - Never work on applied voltage! 4

Important safety instructions 1. SAVE THESE INSTRUCTIONS The manual contains important safety and operating instructions. 2. Only suspend the Power supply to the temperature ranges specified in the datasheet. 3. The use of accessories which is not recommended or sold by the manufacturer can result in a risk of electric shock or personal injury. 4. Do not use the power supply furthermore, when there was a hard blow, fall damage or was damaged in any other way. In this case send the unit to a Deutronic service station. 5. The power supply may not be opened. If a service or a repair is needed, the device must be sent to an official Deutronic service center. Incorrect installation can result in electric shock or fire. 6. To reduce the risk of electric shock, the device must be disconnected from mains before maintenance or cleaning. The device`s switch-off only does not reduce the risk. 5

2) Technical Data For detailed technical data like input voltage, required mains fuse etc. see respective data sheet, which you can get on our product-cd, at our homepage www.deutronic.com or on request direct from Deutronic. 3) Installations The DP500IP power supplies are well suited for screw mounting by its mounting holes in the base plate. To ensure an optimal operation especially flat, thermally conductive mounting surfaces are recommended. For cooling requirements consider the values for overtemperature at the reference point in the appropriate datasheet. An optional adapter for DIN rail mounting is available as an accessory. Mains connection: The connection of N, L, PE (1-phase) or L1, L2, L3, PE (3-phase) is realized via the connectors of the mains cable. The PE connection is designed green/yellow in European countries and in the USA only green or green/yellow. 1AC-Typen sind zum Anschluss an IT-Netze geeignet. 1AC types are applicable in IT-networks. 3AC types are not applicable in IT-networks. Make sure before starting: The mains connection must be carried out professionally and the protection against electric shock must be secured. In accordance with the standards of UL 508 and NEC the device must be switchable in volt-free mode outside the power supply (e.g., by a breaker or the primary-side cable protection) The ground conductor (PE) has to be connected. Output connection: DC-Output: White= +Uout, Black = GND 6

4) Function and Signals The DP500IP/3-24 Power Supply supplies in power boost mode up to 5s with 30A at constant voltage. After the expiration of the 5s the current limit is reduced to 20A. The output voltage is monitored here. If the output voltage differ more than 10% longer than 30s from the nominal output voltage the power supply turns into a locked off condition. A restart is only possible after the input voltage is separated for at least 20s. Furthermore the power boost is not available if the output voltage is outside the tolerance. LED Condition Description Permanent DC-O.K. Uout = 90..110% Unom Blinking (300ms on / 300ms off) DC not OK Uout out of tolerance Flashing (50ms on/ 850ms off) DC Off Locked off condition 7

5) Service Center / Rapair Instructions: Do not open this device! All needed connections and setting elements for operation are accessible from outside. To ensure a fast and smooth processing it is absolutely important that every device sent to Deutronic for repair has a fully filled out return service scripture in which for every device all relevant data (e.g. address, name contact person, phone number etc.) as well as a detailed fault description is included. The needed return service scripture as well as the worldwide service partner addresses you will find on our web page www.deutronic.com in the menu item 'service worldwide'. No liability: The customer is responsible for the use of the device according to the specifications. Regardless of the type, Deutronic is not liable for damage incurred through the use of the device. 8

6) Notes 9

Contact: Deutronic Elektronik GmbH Deutronicstraße 5 D - 84166 Adlkofen / Germany Tel.: +49 (0) 8707 920-0 Document number 33548 All data at nominal input, full load and 25 C ambient temperature, if not marked otherwise. Technical modifications and mistakes reserved. Products are described by information contained in catalogs and data-sheets. It is not be considered as assured qualities. Stresses listed under Maximum Rating (one at a time) may be applied to devices without resulting in permanent damage. The operation of the equipment for extended periods may affect device reliability. Limiting value tolerance are subject to usual fluctuation 10