ES210. Animal & Vet Scale User s Manual (V1611) Anyload Transducer Co. Ltd

Similar documents
EC100. Counting Scale. Operations Manual (V1611)

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

805HP. Handheld Digital Weight Indicator User s Manual (v1703) Anyload Transducer Co. Ltd Website:

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

EB300 Weighing Scale Operation Manual

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:


CONTENTS. PRECAUTIONS Introduction Installation... 7

MWP SERIES. High Precision

9. FUNCTION MENU SETTINGS -TION FUNCTION DESCRIPTION DEFAULT. VALUE F0 H-L SEt Lo Set a value for the Low

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED

AELP PALLET BEAMS SCALES

Copyright Western Scale Co. Limited. All rights reserved.

EHC-WF. User/Technical Manual. Contents subject to change without notice

WUNDER SA.BI.SRL EN USER MANUAL. MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED. User Manual

KW serial. User s guide. Bench Scales UGKW-E0302

IDS-801 Series Compact Bench Counting Scale. User Manual

Oxford E Series. Instruction Manual

Trade Approved Version NMI: S520

1.0 Description. 2.0 Unpacking. 3.0 Installation

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual

NB/NHB Precision Balance

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

Totalcomp TLI Indicator. Operation and Maintenance Manual Manual

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050

PLATINUM PRO1001DXP DIGITAL COUNTERTOP / PORTABLE BALANCE

Division Services. Model: DPAS-300. Division Portable Bulk Load Accumulator Scale INDUSTRIAL PH (901) FAX (901)

INTRODUCTION INSTALLATION

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

Warning. Warning. Warning. Pay Attention to Static Electricity. Ask professional personnel to debug, detect. and repair controller.

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Technical Parameter... 4 Installation and Connection... 5

1. Introduction Specifications Operation Guide Trouble-shooting Note... 13

FG-7000 Digital Force Gauge Operation Manual

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

SERVICE MANUAL iforks

NOTE. This is warning & caution mark. This is hazard alert mark. This is useful information mark

Digital Weight Indicator Setup / Operation Manual

Model SRV411i Small Animal Floor Scale Service Manual Part No. MANSRV411i_ Page 1 of 16. Small Animal Floor Scale. Operating and Service Manual

What s In The Box. Key Descriptions. - ON/OFF - Turns the scale MOXIE ON or OFF. PCS - Enter counting mode. Hold to set sample quantity for average

CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 DISPLAY AND KEY: 7.0 DEALER S SETTING CAUTIONS PREPARATION DISPLAY

AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct.

BW/BWS Weighing Indicator

OMEGA SERIES COUNTING SCALE

uline.com OVERVIEW OF CONTROLS. k g. Tare Menu. Exit. Print. Units PRINT

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5

SAC / SHC / SHC-CH SERIES

Multi-Function Smart Indicator User Manual

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.

PS-IN202 Weighing Indicator User Manual

BBA-Series Precision Balances

Weighing Indicator M701. Handrail scales. REV: M1, April,05,2014 (v )

Bright Advance Corporation USER INSTRUCTIONS

BATTERY MAINTENACE ERROR MESSAGE SPECIFICATIONS... 22

PC 150. Digital Bench Scale. Operation Manual

Digital Weighing Indicator XK3190-A12 User Manual

Counting Scale. HC-3Ki. HC-15Ki HC-6Ki WM+PD

TWP series. Weighing Indicator Service Manual

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.

Cảm ơn các bạn đã tham khảo tài liệu cân điện tử từ CÂN ĐIỆN TỬ GIA PHÁT!

Model Bulk Sampling Scale. User s Manual

TWP-W. Weighing Indicator Service Manual

User s Manual. Digital Baby Scales. Hopkins Featherweight Baby Scale # Hopkins Featherweight XL Baby Scale # # #688340

! User Manual Rev. 1

YH-T8 Weighing Indicator

DL Series NEWDOLBO OWNER S MANUAL. Simple Weighing Scale 9002-DL

CW Series Check Weighing Scales. Instruction Manual

CAUTIONS... 4 INTRODUCTION...

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice.

COMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery.

FG-3000R Digital Force Gauge Operation Manual

Sartorius Research. R 160 P Electronic Semi-Microbalance

Chapter III Operation Instruction I. Start II. Key Operation III. Weighing Operation

PRECAUTIONS...4 PREFACE...6 NAMES AND FUNCTIONS...6 INSTALLATIONS...8 OPERATIONS...11 ERROR MESSAGE...13 SPECIFICATIONS...13

FG-3000 Digital Force Gauge Operation Manual

FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale

FG-7000L Digital Force Gauge Operation Manual

Model SRV945-BT 24 X 36 Platform Scale App-Enabled Operating and Service Manual Part No.: MAN945-BT_ Page 1 of 16.

Simple Weighing Scale. SW-1S / 1C Series OWNER S MANUAL 9002-SW

The ultimate multi-purpose digital scale Ideal for letters, parcels and large boxes

TL-Series. User Manual. American Weigh Scales. TL-330 (330lb x 0.2lb) TL-440 (440lb x 0.5lb)

This document courtesy of:

G2 Series Multi-Function Weighing Scales

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

MODEL PS-11 DIGITAL PORTION SCALE

Operating instructions METTLER TOLEDO BD balances

BW/BWS/VW/CW/NTW/NSW. Weighing Indicator

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

Pennsylvania Scale Company Model 400B Battery Powered Digital Indicator Operation & Calibration Manual

S2 USER MANUAL. AL Manual 110ES WL S2 En 103

CONTENTS. 1. Preface Features Technical Specifications Application of Dummy Plate Usage of Connector & Roller...

TI-500 Plus DIGITAL WEIGHT INDICATOR Setup / Operation Manual

Transcription:

ES210 Animal & Vet Scale User s Manual (V1611) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com Fax: +1 866 612 9088 North America Toll Free: 1-855-ANYLOAD (269 5623)

TABLE OF CONTENTS 1. Introduction 2 2. Safety Recommendations 2 3. Structure and Installation 3 4. Packing List 3 5. Buttons and Functions 3 6. Operation 4 6.1 Turn on 4 6.2 Turn off 4 6.3 Weighing 4 6.4 Calibration Methods 4 6.5 Switching Unit 6 6.6 Keeping Function Hold 6 6.7 Print output function 6 6.8 Counting Sample 6 6.9 Serial Port Printout 7 7. Parameters Settings 8 8. Cue Codes 10 9. Maintenance 10 10. Troubleshooting 11 11. Specifications 11 1 ANYLOAD ES210 Animal & Vet Scale User s Manual (V1611)

1. Introduction Thank you for purchasing the Anyload ES210 series Animal and Vet Scale. The ES210 animal & Vet Scale measures force and weighs of an object through the use of a high-precision load cell, processes data by microcomputer, and displays data by LCD indicator. Features include simplicity of operation, quick measurement, high precision and stability, etc. The scale includes a removable rubber mat preventing animals from slipping while also featuring a side handle for easy portability. Its platter is made of stainless steel for easy clean up and is ideal for veterinarian clinics or agricultural settings. These Vet scales series include a digital indicator with multiple functions such as auto shut off, auto calibration, auto zero tracking and stability indication. Additionally, the ES210 vet scales also have a unit button to switch among kilograms, pounds and counting function as well as adjustable feet to ensure accurate weighing. Anyload ES210 animal and veterinary platform scales are used for weighing small and medium sized animals and applicable in veterinary hospitals as well. This manual provides the user s guide in using the product, safety, installation, features and technical specifications, calibration procedures, configurations and other technical related in using the scale. 2. Safety Recommendations When using this weighing equipment the following recommendations shall be observed for safety: The weighing machine may only be used with the power adapter supplied exclusively for use with the weighing machine. Before inserting the power adapter, the user must ensure that the operating voltage stated on the power adapter agrees with the mains voltage. If not, please contact Customer Service at the address above. If the power adapter or its cable is damaged, the weighing machine must immediately be disconnected from the electricity supply (pull out the power adapter). The weighing machine may only be operated from mains electricity supply with a power adapter which is in perfect condition. 2 ANYLOAD ES210 Animal & Vet Scale User s Manual (V1611)

If there should be any reason to believe that it is no longer possible to operate the weighing machine without danger, the weighing machine is to be immediately unplugged from the electricity supply (pull out power adapter) and secured against inadvertent operation. 3. Structure and Installation 4. Packing List 1 Animal Scale 1 piece 2 AC Adapter 1 piece 3 InstrucIon 1 copy 4Guarantee Statement 1 copy 5. Buttons and Functions Key Button Function Menu Function Serial port order code Power Button Turn on/off Null O Unit Button Hold Button Enter Button Switch the unit Hold / Print function Tare Go Down on menu or parameters Go Up on menu or parameters Enter menu or confirm the change of parameters U H T 3 ANYLOAD ES210 Animal & Vet Scale User s Manual (V1611)

6. Operation 6.1 Turn on Adapter: Insert the plug of AC Adapter into the power supply hub which is on the left of the Display Indicator, and insert the AC Adapter into AC socket. Battery:Open the battery cover which is on the right of the Display Indicator, load 4 x AAA alkaline cells into the cell box (note the polarity) and then close the battery cover. Empty the platform, press button once, it will show all the characters then the Maximum Capacity and Division. After the screen displays 0, you can begin to measure the object. 6.2 Turn off When power-on, press button to turn off the scale. 6.3 Weighing When power-on, with nothing on the platform, press button once, the instrument will then display 0. Place an object on the platform. After the kg, lb or pcs character stops flashing, which means that the data is stable, you can begin to read it. 6.4 Calibration Methods 6.4.1 Random Single-point Calibration a) At weighing mode, press and hold button until the window displays ----- - ; b) Press or button to enter calibration mode; c) Press button to make sure enter the calibration mode; d) After entering the calibration mode, the window will display Load and 0.0kg alternately,which means that the weight 0.0kg should be loaded on the platform; e) After making sure that there is nothing on the platform, press button to confirm so that the scale begins 0.0kg calibration. In the process of 0.0kg calibration, 0.0kg will flicker rapidly on the display window;keep the platform calm, stable, and without other interference factors which will 4 ANYLOAD ES210 Animal & Vet Scale User s Manual (V1611)

influence the weighing performance. If the weighing remains stable for longer than 2s, the scale will finish 0.0kg calibration automatically, it will then begin the next calibration point; otherwise, 0.0kg will keep flickering to wait for the scale to stabilize. f) Suppose that the next calibration point should be xx.xkg, the window will display Load and xx.xkg alternately,which means that the weight xx.xkg ( WEIGHT)should be loaded on the platform. If you have to change this weight, you can press or button to enter the modify menu; then press button to change the flashing position and press button to make the flashing position s number plus 1, and press button to make sure the modification is finished; g) After making sure the weight on the platform is xx.xkg, press button to confirm so that the scale begins the xx.xkg calibration. In the process of xx.xkg calibration, xx.xkg flickers rapidly on the display window;keep the platform calm, stable, and without other interference factors which will influence the weighing performance. If the weighing remains stable for more than 2s, the scale will finish xx.xkg calibration and save the calibrated parameters, then will return to the weighing mode; otherwise, xx.xkg will keep flickering until the scale stable 6.4.2 Standard Two Point Weight Calibration a) At weighing mode, press and hold button until the window displays -- ---- ; b) Press or button cycle the display until the window displays Line ; c) Press button to begin calibration procedure; d) After the scale begins to calibrate, the window will display Load and 0.0kg alternately; e) After you confirm that there is nothing on the platform, press button to confirm and begin the zero calibration when the window displays 0.0kg. In the process of zero calibration, 0.0kg flickers rapidly on the display window; please keep the platform calm, stable, and without other interference factors which will influence the weighing performance. If the weighing keeps stable exceeding 2s, the scale will finish zero calibration automatically, and then it will 5 ANYLOAD ES210 Animal & Vet Scale User s Manual (V1611)

begin the next calibration point, otherwise, 0.0kg will keep flickering to wait for the stable weighing f) Repeat the step d) and step e) above, calibrate the half capacity range point and the Full capacity range point orderly, save the calibrated parameters automatically and return to the weighing mode. 6.5 Switching the Unit Press the button to switch the unit of measurement, kg --- lb--- pcs--- kg. 6.6 Keeping Function Hold Once the key is pressed: 6.6.1 The CPU will send the weight data into RS232 socket. 6.6.2 The weight will remain on the display for 120 seconds after the item has been removed from the scale so the weight can easily be read. a) Place the item on the scale platform. b) Wait for the stable weights to be displayed. c) Press the key. The hold indicators will turn-on. d) Remove the item from the scale platform. The item s weight reading will remain on the display for 120 seconds. e) Quit to hold function: Once an item is weighed and the hold function is enabled; when you want to quit to hold function, press the key again to cancel the hold indicator and return the scale to weight value 6.7 Print output function Press and hold the for 2 seconds, then the buzzer will sound, and the weight data will output to the computer or the serial printer. 6.8 Counting Sample a. During counting mode, remove unrelated objects on the platform, then press button to revert to zero; b. Press button to switch the unit into PCS, and the window will display ADD10. 6 ANYLOAD ES210 Animal & Vet Scale User s Manual (V1611)

c. ADD10 means that 10 objects to be weighed should be added onto the platform. Attention: The weight of each sample should be higher than the scale s minimum division value; otherwise, the window will display wrong cue no. d. If you want to change the sampling quantity, please press the button to change the quantity; if you do not need to sample again, press the button to cancel the sampling, and the scale will adopt last sampling value to count ; e. After you confirm the quantity of objects on the platform and the data displayed on the LCD are the same, short press to confirm, and then begin to sample and count; f. During the process of sampling and counting, the screen will display the sampling data by rapidly flickering; keep the platform calm, stable, and without other interference factors which will influence the weighing performance. If the weighing stays stable longer than 2s, the sampling and counting will be automatically finished, the parameter will be saved automatically and the scale will return to counting mode; if not, the screen will keep flickering the data and waiting for the stability of measuring. 6.9 Serial Port Printout a. Connect the serial port with the scale according to the drawing below. Baud Rate=9600,without parity digit, sent stop bit 1 (The serial connection diagram is omitted); PS Scale PC or Printer b. Open the serial communication software, for example, HyperTerminal in windows. Select the connected portal number COM and set the baud rate as 9600bps, the parity bit as NONE, the data bit as 8Bit, and the stop bit as 1Bit. c. You can select the serial output modes according to your own needs. The output modes include 3 types: output by pressing button, automatic output after the weight keeps stable, and continuous output. You can set though the out in Parameter setting. 7 ANYLOAD ES210 Animal & Vet Scale User s Manual (V1611)

d. Output Data Form: 8 bytes data bit + 3 bytes unit code + 2 bytes ending code. The above-mentioned characters are all ASCII codes, and the unit can be kg, lb or pcs. e. The serial ports order can be f0und in Chapter 2 button function. Example of Output Data Display Data Bit Unit Code Ending Code 1 2 3 4 5 6 7 8 9 10 11 12 13 123.45kg Blank Blank 1 2 3. 4 5 k g Blank CR LF -123.45lb Blank - 1 2 3. 4 5 l b Blank CR LF 123.0pcs Blank Blank Blank 1 2 3. 0 p c s CR LF 6.10 When the scale is on, press and hold key until the display "0FF" or "ON", then release. That means open or close the function of animal weighing. When the action symbol which is above the units symbol flashes, that means the current mode is animal mode. in this state, once the weighing is locked, it will automatically remain locked weighs for about 10 seconds 7. Parameters Settings a) When the scale is off, please press button together with the button to turn on the scale. Do not release the button until the screen displays ----- ; b) Press the or button to switch the menu; c) Press the button to enter the display menu; d) After entering the display menu, press the or button to select the parameter; e) Press the button to confirm the parameter, and return to the menu; f) After all the parameters have been set, switch the menu to -End-,and press the button to finish the setting and save the parameters, then return to the weighing or counting mode. 8 ANYLOAD ES210 Animal & Vet Scale User s Manual (V1611)

Parameters Table: Menu 1.codE 2.ASt 3.out 4.LEd 5.OFF 6.-LL- 7.-HH- -End- Meaning of Menu Check the internal code Zero tracking range Printout method Backlight control method Automatic shutdown control Set Lower limit alarm Set upper limit alarm Finish measuring and save the parameters Selectable Parameter null 0.5/1/2/3d key/auto/conti OFF/Auto/on no/3/510/15/30 /60 min xxxx(lower limit value) xxxx(upper limit value) null Meaning of Parameter Check the internal code for debugging by manufacturer. Set automatic zero tracking range. key:printout while press the key,auto:printout automatically,conti: printout continuously OFF:backlight is turned off,auto:backlight is automatic,on:backlight is turned on. no:no automatic shutdown; 3~60min:if there is not any action of weighing objects or pressing buttons, the instrument will automatically turn off. If the lower limit value is set to 0, the lower limit alarm function is canceled. If the upper limit value is set to 0, the upper limit alarm function is canceled. 9 ANYLOAD ES210 Animal & Vet Scale User s Manual (V1611)

8. Cue Codes Display Code no Meaning of Code 1. The calibration weight value is not loaded according to the display when calibrating. 2. The quantity of objects is not loaded according to the quantity of sampling. Solution 1. Load the weight value according to the show value. 2. Load the quantity according to the show value. AC The batteries are brownout. 1. Use new batteries. 2. Use power adapter. Err-0 The calibration data is lost 2. The load cell or main board maybe damaged. Re-calibrate. 2. Change the Loadcell or main board. Err-1 1. The weight is over the max capacity. 2. Lost the calibration data. 3. The load cell or main board maybe damaged. 1. Remove the objects on the platform. 2. Re-calibrate. 3. Change the loadcell or main board. --L-- Lower limit alarm 1. cancel lower limit alarm --H-- Upper limit alarm 1. cancel upper limit alarm 9. Maintenance In order to keep the scale s normal operating, the crust of indicator and the platform of scale should be kept clean and prevented from corrosion by foreign substance. If necessary, you should use a piece of cloth with mild washing agent to clean them. When you don t use the scale, pull out the A/C plug. If not being used in a long time, please take out the batteries 10 ANYLOAD ES210 Animal & Vet Scale User s Manual (V1611)

10. Troubleshooting Cause Reason Solution No display The power plug is not inserted in the right place. Insert the plug in right place. Use the new batteries. The batteries are expired. Low-voltage indication The batteries power is low. Use the new batteries. Error in weighing data-reading False calibration The scale didn t back to zero before using. The scale is not calibrated. The calibration weight is not precise. Do not put objects on the platform, press button, and then begin to weight. Re-calibrate. Use the precise calibration weight. 11. Specifications Model ES210 Capacity x Readability 200 0.05kg Pounds (lb) 440 0.1lb Parts counting Standard Repeatability (std.dev) 0.05kg Linearity ±0.05kg T range To capacity by subtraction Over range capacity Capacity + 9d Stabilization time 2sec Sensitivity drift (%) 0.01 Operation 10~40 C temperature Power requirements 110 or 220V 50/60Hz AC adapter (included); Or 4 AAA batteries Platform size (mm) 900 600 Dimensions 900 600 85 (W L D) (mm) Net weight (kg) 12.5 Shipping weight (kg) 14.6 11 ANYLOAD ES210 Animal & Vet Scale User s Manual (V1611)