Brilliance CT Big Bore.

Similar documents
Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT. AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD

Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for stereotactic body radiation therapy

Helical 4D CT pitch management for the Brilliance CT Big Bore in clinical practice

An investigation of temporal resolution parameters in cine-mode four-dimensional computed tomography acquisition

Retrospective Spiral Respiratory Correlated Imaging with Varian RPM

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT

An automated method for comparing motion artifacts in cine four-dimensional computed tomography images

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

Tumor motion during liver SBRT

Motion artifact detection in four-dimensional computed tomography images

UvA-DARE (Digital Academic Repository) Motion compensation for 4D PET/CT Kruis, M.F. Link to publication

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study

Estimating 3D Respiratory Motion from Orbiting Views

A closer look at CT scanning

Analysis of Acquisition Parameters That Caused Artifacts in Four-dimensional (4D) CT Images of Targets Undergoing Regular Motion

PURE. ViSION Edition PET/CT. Patient Comfort Put First.

2005 IEEE Nuclear Science Symposium Conference Record M10-2

ROBUST OPTIMIZATION THE END OF PTV AND THE BEGINNING OF SMART DOSE CLOUD. Moe Siddiqui, April 08, 2017

Reconstruction of 4D CT data sets acquired during free breathing for the analysis of respiratory motion

Development and Optimization of Fourdimensional Magnetic Resonance Imaging (4D-MRI) for Radiation Therapy

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Digital Image Processing

Patient Set-ups and Tumor Localizations

8/3/2016. MR-guided RT: Commissioning and Quality Control. Topics for MR-guided RT system commissioning & QC

Using a research real-time control interface to go beyond dynamic MLC tracking

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

Moving Metal Artifact Reduction for Cone-Beam CT (CBCT) Scans of the Thorax Region

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

Image Guidance and Beam Level Imaging in Digital Linacs

Respiratory Motion Estimation using a 3D Diaphragm Model

Image Acquisition Systems

Monaco VMAT. The Next Generation in IMRT/VMAT Planning. Paulo Mathias Customer Support TPS Application

Real Time Tumor Motion Tracking with CyberKnife

Computer-Tomography II: Image reconstruction and applications

Advanced Targeting Using Image Deformation. Justin Keister, MS DABR Aurora Health Care Kenosha, WI

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

Automatic Intrinsic Cardiac and Respiratory Gating from Cone-Beam CT Scans of the Thorax Region

Robust Lung Ventilation Assessment

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

Tomographic Reconstruction

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Fundamentals of CT imaging

Novel methods and tools for MR Commissioning and Quality Control

RADIOLOGY AND DIAGNOSTIC IMAGING

Moving stereotactic fiducial system to obtain a respiratory signal: proof of principle

Financial disclosure. Onboard imaging modality for IGRT

UvA-DARE (Digital Academic Repository) Motion compensation for 4D PET/CT Kruis, M.F. Link to publication

Fmri Spatial Processing

Iterative sorting for four-dimensional CT images based on internal anatomy motion

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

7/31/ D Cone-Beam CT: Developments and Applications. Disclosure. Outline. I have received research funding from NIH and Varian Medical System.

A modified McKinnon-Bates (MKB) algorithm for improved 4D cone-beam computed tomography (CBCT) of the lung

Impact of a novel exponential weighted 4DCT reconstruction algorithm

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

The Near Future in Cardiac CT Image Reconstruction

4-D Modeling of Displacement Vector Fields for Improved Radiation Therapy

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

Radiotherapy Plan Competition TomoTherapy Planning System. Dmytro Synchuk. Ukrainian Center of TomoTherapy, Kirovograd, Ukraine

Four-Dimensional MVCT Imaging and Spatial Translation of Helical Tomotherapy Dose Distributions Using Sinogram Modification

[PDR03] RECOMMENDED CT-SCAN PROTOCOLS

Ch. 4 Physical Principles of CT

Digital Tomosynthesis for Target Localization

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Purely Data-Driven Respiratory Motion Compensation Methods for 4D-CBCT Image Registration and Reconstruction

Philips SPECT/CT Systems

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

Significance of time-dependent geometries for Monte Carlo simulations in radiation therapy. Harald Paganetti

Binning Without a Model for Cone-beam CT

Respiratory Motion Compensation for C-arm CT Liver Imaging

View Aliasing Artifacts Reduction Method Based on 4D Cone-Beam CT Reconstruction with Joint Projection Data

Imaging Guide Pancreatic Imaging

Imad Ali 1 Nesreen Alsbou 2 Justin Jaskowiak 1 Salahuddin Ahmad 1. Abstract RADIATION ONCOLOGY PHYSICS

State-of-the-Art IGRT

Some reference material

CLARET: A Fast Deformable Registration Method Applied to Lung Radiation Therapy

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

Fast Dynamic MRI for Radiotherapy

ESTIMATING 3D DEFORMABLE MOTION FROM A SERIES OF FAST 2D MRI IMAGES. Jason M. Brown. Chapel Hill 2016

Motion Artifacts and Suppression in MRI At a Glance

Chapter 32 3-D and 4-D imaging in Obstetrics and Gynecology

Imaging protocols for navigated procedures

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

Carestream s 2 nd Generation Metal Artifact Reduction Software (CMAR 2)

Functional MRI in Clinical Research and Practice Preprocessing

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Image Co-Registration II: TG132 Quality Assurance for Image Registration. Image Co-Registration II: TG132 Quality Assurance for Image Registration

SPM8 for Basic and Clinical Investigators. Preprocessing

Chapter 7 Feasibility Study for 3D Online Motion Compensation

Corso di laurea in Fisica A.A Fisica Medica 4 TC

2 Michael E. Leventon and Sarah F. F. Gibson a b c d Fig. 1. (a, b) Two MR scans of a person's knee. Both images have high resolution in-plane, but ha

SPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing

CBCT: Past, Present and Future. Disclosures. Computed Tomography. ATec Education Course Feb 28-Mar3, Douglas Moseley PhD, DABR

Optimisation of Toshiba Aquilion ONE Volume Imaging

Measurement of inter and intra fraction organ motion in radiotherapy using cone-beam CT projection images

icatvision Quick Reference

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending

Analysis of 4D CT cine images for the characterization of organ motion due to breathing

Comparison of Scatter Correction Methods for CBCT. Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis

Transcription:

1

2

2

There are two methods of RCCT acquisition in widespread clinical use: cine axial and helical. In RCCT with cine axial acquisition, repeat CT images are taken each couch position while recording respiration. An example is shown of a GE multislice CT scanner in combination with the Varian RPM system for monitoring respiration, specifically, abdominal displacement by means of an infrared reflecting block placed on the patient. The data sufficiency condition is such that, acquisition at each couch position is normally 1 s longer than the average breath cycle. The time interval between successive CT images is typically 0.45 s or less, yielding 15 to 20 images per slice location. This is a trade-off between a sufficient number of samples for retrospective sorting and limiting the imaging dose. A 0.5 s gantry rotation yields the highest temporal resolution CT images. In cine-based RCCT, the axial CT slices are reconstructed first, then retrospectively sorted into typically 10 bins across the respiratory cycle, most commonly according to the phase of the respiration trace. 3

The alternative approach uses helical CT acquisition with low pitch and gantry rotation chosen such that each voxel in the patient is viewed by the CT detectors for at least 1 cycle, again while recording respiration. In helical RCCT, CT slices are retrospectively reconstructed, using the sinogram data at the desired respiration phase, e.g. those at end inspiration are selected at the 0% phase, and approximate end expiration at the 50% phase. The requirement that the couch moves slowly enough such that each voxel is viewed at least one cycle determines a maximum pitch which is breathing rate dependent, as shown in the table for the Philips Brilliance CT Big Bore. 4

5

The advantages of RCCT are twofold: first, it reduces respiratory motion-induced distortions of the anatomy; second, it provides 3-D visualization of motion across one breath cycle. The standard helical CT example illustrates the motion-induced distortions that may occur. It is important to keep in mind that in RCCT, retrospective sorting maps CT slices from several cycles into one, thus it assumes that breath cycles are repeatable. This assumption is violated to some degree by practically all patients, leading to artifacts such as those shown here. 6

The distortions that one sees in phase-sorted RCCT are caused in many (but not all) cases by changes in breathing amplitude. This is illustrated by the lower plot of tidal volume vs time at left: phase sorting at end expiration selects the points marked in red. There is large variation in tidal volume between points, leading to artifacts in the image at end expiration and elsewhere in the cycle (lower row of images). The same problem occurs for phase sorting using abdominal displacement (RPM), because internal motion correlates with external respiratory motion. Amplitude sorting reduces the variation in selected points on the respiration trace (blue points in upper plot), and reduces image artifacts (upper row of images). 7

A limitation of amplitude sorting is that the respiration trace may not intersect the selected amplitude at all cycles, leading to missing slice data and hence gaps in the 3-D images (left). The amplitude sorting algorithm in Philips Brilliance CT illustrates a possible way to address this problem at right: when the identical amplitude is not always available because the patient breathed shallowly on some cycles, the algorithm chooses the nearest available amplitude (dashed orange line). 8

9

A primary clinical use of RCCT is to define motion-encompassing internal target volume (ITV). Maximum intensity projection (MIP) often used to define tumor in lung. An MIP image is computed by choosing, for each voxel location, the maximum CT number from the RCCT image set. This usually works well to identify a tumor surrounded by low-density lung tissue. But MIP may underestimate lung tumor ITV when the tumor is attached to tissue of similar density, such as diaphragm, mediastinum, or chest wall. Lower row of images show an example of tumor adjacent to diaphragm. At left, the tumor is not visible in maximum intensity projection image because of overlap with diaphragm. Middle: Tumor (outlined in green) is visible in the RCCT at end inspiration. Right: MIP image underestimates the inferior extent of the ITV (orange) compared to an encompassing volume derived from the individual RCCT images (green). 10

An alternative approach to ITV definition is MIP (left), overlaying the resultant ITV on all images in the RCCT set, and verifying that the GTV is contained on each of the images. Example is shown at center: the resultant ITV is consistent with the more laborious approach of drawing the GTV on each RCCT image, then computing the union of the GTVs. 11

It is worthwhile to note that a motion-encompassing ITV may overestimate the internal margin needed in terms of dose to target. Upper left figure is a 2D dose profile of a 3cm radius CTV with no respiratory motion. When 10mm peak-to-trough motion is introduced, a treatment plan with no internal margin yields a minimum dose to target of 94% of prescription, only slightly lower than that for the treatment plan of the static target (Dmin = 96%, see inset in upper right figure). Further, a motion plan with only a 1.5mm internal margin yields the target DVH as the static plan, whereas the target receives more dose than the static plan when the full range of motion (+- 5mm) is used for the IM expansion. 12

13

RC-CBCT uses slow gantry rotation (~3 min over 200 ) and retrospective sorting of projections according to internal or external respiratory signal. Typical thoracic RC-CBCT scans with Elekta XVI 4.5 Symmetry take 3 minutes with 200 degree gantry rotation (Peng et al 2012). Figure illustrates the correlation of projection data and respiratory signal in the RC-CBCT (Lu et al 2007). The projections are sorted into different groups according to respiratory phase, and a set of projections are grouped for each 10% phase window. Only three phases 0%, 40%, and 70% are shown. 14

15

The advantages of RC-CBCT are that motion-induced blur is reduced, and motion extent can be measured. In standard CBCT (top row) tumor and diaphragm are blurred, whereas in the RC-CBCT image at end expiration (middle) and end expiration (bottom) soft tissue features are sharper. But the RC-CBCT images exhibit treaking artifacts, particularly apparent in the axial images. 16

Disadvantages of RC-CBCT are twofold: 1) the longer scan times (3 minutes or more) owing due the slower gantry rotation; 2) the limited number and nonuniform arrangement of projections per reconstructed phase bin cause streaking artifacts. Phase-sorted projections cluster in a wagon wheel arrangement (left), causing streaking artifacts with a similar appearance. Streaking artifacts diminish with slower gantry rotation (right), but at a cost of longer scanning times. 17

Varian has developed a fast 4D CBCT reconstruction based on the McKinnon-Bates algorithm. A prior image is reconstructed using all projections belonging to all phases. The prior is forward-projected and the resulting projections are subtracted from the original projections to create motion-enhanced difference images, one for each respiratory phase. These are added to the prior to create streak-reduced phase-correlated images. 4D CBCT is currently available offline in ARIA for evaluating motion, but is not available for online image guidance. 18

19

In the Elekta system, RC-CBCT is commonly used to monitor the displacement of mean tumor position relative to the planned position. This is accomplished by registering each image in the RC-CBCT set to the reference CT by aligning the tumor in both images. This computes a trajectory of tumor positions, from which a time-weighted average position is computed, called a baseline. An example baseline shift between 2 RC-CBCT scans 5 days apart is shown at lower right. Left image shows the tumor position discrepancy at end expiration, right image at end inspiration. 20