Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Similar documents
Ch. 4 Physical Principles of CT

Tomographic Reconstruction

MEDICAL IMAGING 2nd Part Computed Tomography

Computer-Tomography I: Principles, History, Technology

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

Introduction to Biomedical Imaging

CT vs. VolumeScope: image quality and dose comparison

BME I5000: Biomedical Imaging

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

Image Acquisition Systems

Corso di laurea in Fisica A.A Fisica Medica 4 TC

Physical bases of X-ray diagnostics

Some reference material

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Computed tomography - outline

A closer look at CT scanning

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

Digital Image Processing

8/7/2017. Disclosures. MECT Systems Overview and Quantitative Opportunities. Overview. Computed Tomography (CT) CT Numbers. Polyenergetic Acquisition

First CT Scanner. How it Works. Contemporary CT. Before and After CT. Computer Tomography: How It Works. Medical Imaging and Pattern Recognition

Computed Tomography. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Sep 26th/Oct 3rd, 2016

RADIOLOGY AND DIAGNOSTIC IMAGING

Computer-Tomography II: Image reconstruction and applications

Fundamentals of CT imaging

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

1970 Projection Radiography 2D projection of 3D anatomy

Moscow-Bavarian Joint Advanced Student School 2006 / Medical Imaging Principles of Computerized Tomographic Imaging and Cone-Beam Reconstruction

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

CT: Physics Principles & Equipment Design

MEDICAL IMAGING 2nd Part Computed Tomography

Cardiac Dual Energy CT: Technique

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Computed Tomography January 2002 KTH A.K.

Computational Medical Imaging Analysis

Enhanced material contrast by dual-energy microct imaging

Diagnostic imaging techniques. Krasznai Zoltán. University of Debrecen Medical and Health Science Centre Department of Biophysics and Cell Biology

GPU implementation for rapid iterative image reconstruction algorithm

Computational Medical Imaging Analysis

Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

Medical Imaging BMEN Spring 2016

[PDR03] RECOMMENDED CT-SCAN PROTOCOLS

Scatter in an uncollimated x-ray CT machine based on a Geant4 Monte Carlo simulation. Wadeson, Nicola and Morton, Edward and Lionheart, William

A study of densitometry comparison among three radiographic processing solutions

Digital Scatter Removal in Mammography to enable Patient Dose Reduction

Medical Imaging Projects

INTERNATIONAL STANDARD

DUAL energy X-ray radiography [1] can be used to separate

DUAL-ENERGY CT IN PROTON THERAPY

Introduction to Positron Emission Tomography

TEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units

LAB DEMONSTRATION COMPUTED TOMOGRAPHY USING DESKCAT Lab Manual: 0

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

X-ray Tomography. A superficial introduction, but sufficient enough to get us started in surgical navigation.

Financial disclosure. Onboard imaging modality for IGRT

Comparison of Scatter Correction Methods for CBCT. Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis

X-ray tomography. X-ray tomography. Applications in Science. X-Rays. Notes. Notes. Notes. Notes

Micro-CT Methodology Hasan Alsaid, PhD

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

Computed tomography (Item No.: P )

Spectral analysis of non-stationary CT noise

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

Contrast Enhancement with Dual Energy CT for the Assessment of Atherosclerosis

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

Optimisation of Toshiba Aquilion ONE Volume Imaging

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT

UNIVERSITY OF SOUTHAMPTON

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Emission Computed Tomography Notes

Enhancement Image Quality of CT Using Single Slice Spiral Technique

NON-COLLIMATED SCATTERED RADIATION TOMOGRAPHY

Fits you like no other

Effect of Scattering on the Image. Reducing Compton Scatter with a Grid

DUE to beam polychromacity in CT and the energy dependence

Principles of Computerized Tomographic Imaging

VJ Technologies Inspection Services Division. By Bob Maziuk, February 2015

CIVA Computed Tomography Modeling

Translational Computed Tomography: A New Data Acquisition Scheme

Digital Image Processing

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

Acknowledgments. High Performance Cone-Beam CT of Acute Traumatic Brain Injury

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

An approach to calculate and visualize intraoperative scattered radiation exposure

Applying Hounsfield unit density calibration in SkyScan CT-analyser

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Joint ICTP-TWAS Workshop on Portable X-ray Analytical Instruments for Cultural Heritage. 29 April - 3 May, 2013

Annexure XII SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER

School on X-ray Imaging Techniques at the ESRF. Pierre BLEUET. ID22 Beamline

Suitability of a new alignment correction method for industrial CT

Philips SPECT/CT Systems

A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis

Scatter Correction Methods in Dimensional CT

COMPARATIVE STUDIES OF DIFFERENT SYSTEM MODELS FOR ITERATIVE CT IMAGE RECONSTRUCTION

Biomedical Imaging. Computed Tomography. Patrícia Figueiredo IST

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects

Introduction to Emission Tomography

Transcription:

Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Overview Introduction

Overview Introduction Tecniques of imaging in

Overview Introduction Tecniques of imaging in Radiography

Overview Introduction Tecniques of imaging in Radiography Computerized Tomography (CT)

Introduction X-ray beam on a patient:

Introduction X-ray beam on a patient: Absorption NO contribution to image Transmission YES, contribution to image Dispersion Diffuse radiation

Introduction X-ray beam on a patient Absorption NO contribution to image Transmission YES, contribution to image Dispersion Diffuse radiation It depends on the characteristics of the tissue:

Introduction X-ray beam on a patient Absorption NO contribution to image Transmission YES contribution to image Dispersion Diffuse radiation It depends on the characteristics of the tissue: Density Atomic number of the elements composing the tissue Thickness Kilovoltage external parameter

Introduction After the patient:

Introduction After the patient: Transmitted radiation + Diffuse radiation Non homogeneus distribution of intensities Latent image Imaging systems Visible image Contrasting zones in the visible image makes possible to distinguish different structures

Introduction After the patient: Transmitted radiation + Diffuse radiation Non homogeneus distribution of intensities Latent image Imaging systems Visible image Contrasting zones in the visible image makes possible to distinguish different structures Human body in a X-ray exposition:

Introduction After the patient: Transmitted radiation + Diffuse radiation Non homogeneus distribution of intensities Latent image Imaging systems Visible image Contrasting zones in the visible image makes possible to distinguish different structures Human body in a X-ray exposition: 1 Gases (air): Z = 6, 7 and ρ = 1 mg/cm 3 2 Soft tissue: water(ρ = 1 g/cm 3 ) and fat (ρ =0.9 g/cm 3 ). 3 Hard tissue: cartilage (ρ =1.1 g/cm 3 y Z = 13) and bone (ρ 1.8 g/cm 3 and Z = 14)

Introduction Gases They transmit practically all the radiation. High number of photons to the latent image. More darkening in the visible image.

Introduction Gases: They transmit practically all the radiation. High number of photons to the latent image. More darkening in the visible image. Soft tissues Medium absorbed dose. Gray areas in the visible image.

Introduction Gases: They transmit practically all the radiation. High number of photons to the latent image. More darkening in the visible image. Soft tissues Medium b dose. Gray areas in the visible image. Hard tissues High absortion power. In visible image, areas nearly white.

Techniques of imaging in Three external parameters:

Techniques of imaging in Three external parameters Voltage: It regulates the stopping power of the radiation Increasing kvp, electrons have a higher kinetic energy.

Techniques of imaging in Three external parameters Voltage: It regulates the stopping power of the radiation Increasing kvp, electrons have a higher kinetic energy. Intensity (ma): Intensity in the X-ray tube. A higher intensity, a higher number of emitted electrons. The production of X-rays increases. A higher darkening.

Techniques of imaging in Three external parameters Voltage: It regulates the stopping power of the radiation Increasing kvp, electrons have a higher kinetic energy. Intensity (ma): Intensity in the X-ray tube. A higher intensity, a higher number of emitted electrons. The production of X-rays increases. A higher darkening. Time (ms): It determines the period of time in which X-rays are produced.

Techniques of imaging in Example:Pelvis radiography 60 kv, 141 mas 75 kv, 36 mas 120 kv, 6 mas

Techniques of imaging in Two techniques

Techniques of imaging in Two techniques Technique of low voltage: Photoelectric effect is the main absortion way. The photoelectric effect depens of the atomic number. Bone higher absorption. Fat lower absorption. Tissues are distinguished according to the absorption. Nearby areas, but of different type, appear with a high contrast.

Techniques of imaging in Two techniques Low voltage technique: Photoelectric effect is the main absortion way. The photoelectric effect depens of the atomic number. Bone higher absorption. Fat lower absorption. Tissues are distinguished according to the absorption. Nearby areas, but of different type, appear with a high contrast. High voltage technique: Torax radiography To see the lung and not the bone. Scattering Compton, the main interaction mechanism. No distintion with the atomic number. The bone loss contrast in the radiography.

Techniques of imaging in Final radiation in the plate:

Techniques of imaging in Final radiation in the plate Primary radiation beam not atenuated. Scattered radiation beam.

Techniques of imaging in Final radiation in the plate Primary radiation beam not atenuated. Scattered radiation beam. Methods to minimize the scattered radiation

Techniques of imaging in Final radiation in the plate Primary radiation beam not atenuated. Scattered radiation beam. Methods to minimize the scattered radiation 1 Increasing of the voltage a higher penetration of the beam. 2 Decreasing of the irradiated volume (tissue compressors ) 3 Separation between object and film 4 Use of collimators to reduce the field size. 5 Anti-scatter grids.

Radiography The X-ray tube

Radiography X-ray spectrum Tugsteno target Molibdeno target Brehmsstrahlung continuum spectra Characteristic X-rays.

Radiography Radiographic film Components in a radiographic film

Radiography Digital radiography

Computerized tomography (CT) Introduction

Computerized tomography (CT) Introduction History of the CT

Computerized tomography (CT) Introduction History of the CT Some technical concepts

Computerized tomography (CT) Introduction History of the CT Some technical concepts The physics of the data acquisition

Introduction It is one of the most important applications of the X-rays.

Introduction It is one of the most important applications of the X-rays. Crucial in its development, the mathematic algorithms to do the image reconstruction from different sectional cuts of the body.

Introduction It is one of the most important applications of the X-rays. Crucial in its development, the mathematic algorithms to do the image reconstruction from different sectional cuts of the body. The obtained images are fundamental for medical diagnosis.

Introduction It is one of the most important applications of the X-rays. Crucial in its development, the mathematic algorithms to do the image reconstruction from different sectional cuts of the body. The obtained images are fundamental for medical diagnosis. Tomographic image of the paranasal sinuses in the frontal plane TAC room.

History of the CT From the idea of A.M. Cormack (1950) and the practical development of G.N. Hounsfield (1960).

History of the CT From the idea of A.M. Cormack (1950) and the practical development of G.N. Hounsfield (1960). A.M. Cormack (SA): Representation of a function by it Line Integrals, in The Journal of Applied Physics. And after, in PMB.

History of the CT From the idea of A.M. Cormack (1950) and the practical development of G.N. Hounsfield (1960). A.M. Cormack (SA): Representation of a function by it Line Integrals, in The Journal of Applied Physics. And after, in PMB.

History of the CT The practical application: G. N. Hounsfield. He works in the central laboratories of EMI Ltd.

History of the CT The practical application: G. N. Hounsfield. He works in the central laboratories of EMI Ltd. In 1967 Hounsfield develops a different system to do the image reconstruction, using all the computing power available.

History of the CT The practical application: G. N. Hounsfield. He works in the central laboratories of EMI Ltd. In 1967 Hounsfield develops a different system to do the image reconstruction, using all the computing power available. In 1971, first practical application in the Atkinson Morley Hospital (Wimbledon). In its first scanner, Hounsfield used a different image reconstruction algorithm (Algebraic Reconstruction Technique, ART)

History of the CT The practical application: G. N. Hounsfield. He works in the central laboratories of EMI Ltd. In 1967 Hounsfield develops a different system to do the image reconstruction, using all the computing power available. In 1971, first practical application in the Atkinson Morley Hospital (Wimbledon). In its first scanner, Hounsfield used a different image reconstruction algorithm (Algebraic Reconstruction Technique, ART) Basic parameters: Scanner time: 4.5 min. Reconstruction time: 20 s. Thickness of the cross section: 13 mm. Image matrix: 80 80 pixels, each one about 3 3 m 2.

History of the CT The scanner EMI Mark I (a) and a brain cross section (b).

History of the CT Important dates in the CT history.

History of the CT Parents of the CT: (a) A. M. Cormack y (b) G. N. Hounsfield. Nobel prize of Physiology and Medicine in 1979.

Some technical aspects Parts of the CT scanner 1 System for data acquisition that makes the projections. 2 Computer system to do the image reconstruction from the projections. 3 An AC generator 4 A monitor system to view the images. 5 Another systems for data storage. Instalation of a CT scanner

Some technical aspects Data acquisition system Different views of the data acquisition system: (a) Front (b) Side (c) Up

Some technical aspects Parts of the data acquisition system 1 The gantry, with a central opening, in which the pacient is moving during the scanner. 2 The X-rays tube, that gives the X-rays source that is passing through the body of the patient, providing the information relevant for the image reconstruction to the system detector. 3 The system detector, that converts the projection values, given as radiation intensities, in electric quantities. This set rotates simultaneously with the X-ray tube. 4 The table, that permits to position in a right way the patient. It is possible to move it from inside to outside the gantry, along the body axis of the patient, and even from up to down.

Some technical aspects CTs of the 1 st generation They use a parallel beam projection system:

Some technical aspects CTs of the 1 st generation

Some technical aspects CTs of the 2 nd generation (1972) A huge number of detectors (up to 52), and a fan beam; Scanning time: 300 s.

Some technical aspects CTs of the 3 rd generation (1976) Try to eliminate the lateral moving of the tube-detector system. Increasing the number of detector that moves simultaneously with the X-rays tube (up to 1000).

Some technical aspects CTs of the 4 th generation (1978) The detector set is built in a stationary ring, with a radius greater than the circle describe by the tube: fixed rotating scanner. The number of detectors is increased up to 5000. Scanning time: 5 s.

Some technical aspects CTs of the 4 th generation (1978)

Some technical aspects CTs of the 4 th generation (1978)

Some technical aspects Last developments 1 The projection system has a spiral movement around the patient (1989): a detectors sect in a circular section (Single-slice Spiral Computed Tomography), SSCT. 2 There are between 8 and 34 detectors rows it is possible to obtain four slices simultaneously (1998): (Multi-slice Spiral Computed Tomography), MSCT. 3 The Cone Beam Spiral Tomography, CBST (2002) permits the simultaneous acquisition up to 256 slices: the combination of the cone beam and the spiral movement of the projection system goes to a very important reduction in the scanning time and the resolution (up to 0.23 mm).

Some technical aspects Last developments The movement of the projection system respect to the patient in a CBST.