M5100 Heavy Industrial Pressure Transducer

Similar documents
M7100 Pressure Transducer

U7100 Pressure Transducer

HIGH ACCURACY PRESSURE TRANSDUCERS

FPS2800B12C4 Fluid Property Sensor Module

FX1901 OEM Compression Load Cell

ED-21 Analog Output Series Magnetic Encoder

Electronic pressure sensors

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

Pressure transmitters OsiSense XMLP for industrial applications. Catalogue

Model 8042 Submersible Accelerometer

TPE 1464 Series Pressure Transducer

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

Twist-lock style " or 2" Tri-Grip TM Fitting. PX429S15-015GV, shown smaller than actual size.

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

MS4525DO DESCRIPTION STANDARD RANGE (PSI)

NOVOTURN Multiturn Sensor non-contacting Series RSM2800 analog

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Model Number Structure

ORDERING INFORMATION # of Ports Pressure Type Device Name

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

Model Number Structure

Model Number Structure

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

TMT470L Temperature Transmitter

MPXHZ6130A, 15 to 130 kpa, Absolute, Integrated Pressure Sensor

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

4-20mA SERIES Single or Dual Axis MEMS Inclinometer

POSIROT. PRAS26 Magnetic Angle Sensor. Magnetic Angle Sensors. Datasheet

Installation Instructions Temperature transmitter TAA /00 06/2011

P027 Series Pressure Transducer Installation & Operation Manual

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

PRESSURE TRANSMITTER

ME to 30W Single Output External Power Medical Series. Features

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

Universal Power Supplies

RTU500 series Data Sheet Power Supply CP-E 24/2.5

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

Aluminum Electrolytic Capacitors Axial Standard Miniature

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

Industrial Power Supplies

Freescale Semiconductor Data Sheet: Technical Data

TEP 100WIR Series, 100 Watt

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

Osisense XML. Electronic Pressure Sensors. Catalog

MPXH6300A, 20 to 300 kpa, Absolute, Integrated, Pressure Sensor

Industrial Power Supplies

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Industrial Power Supplies

Industrial Pressure Transmitter

SM9000. Made in Germany

POSIROT. PRAS2EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Type i2p-100 Electro-Pneumatic Transducer

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

ED-22 Analog Output Series Magnetic Encoder

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Aluminum Electrolytic Capacitors SMD (Chip), High Temperature

Differential Pressure Sensor

Output Voltage* (nom.)(adjustable)

High Voltage AC Power Capacitors 1-Phase Units

P499 Series Electronic Pressure Transducers

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

RMCN22BD Analog Converter ma - for Zelio Analog

WIRELESS SERIES Single or Dual Axis MEMS Inclinometer

MicroPAC AC-DC Power Supply

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Fisher i2p-100 Electro-Pneumatic Transducer

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

5-Line ESD Protection Diode Array in LLP75-6L

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Aluminum Electrolytic Capacitors Radial Miniature, High Voltage

MS4515DO SPECIFICATIONS FEATURES APPLICATIONS

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Model Number Structure

Fisher i2p-100 Electro-Pneumatic Transducer

Enclosed Power Supplies

TMR1202. General Description. TMR Bipolar Switch. Features and Benefits. Applications

MP3V5050V, -50 to 0 kpa, Gauge Pressure Sensor

POWERBOX Industrial Line PMR20W Series 20W 4:1 Single and Dual Output High Performance DC/DC Converter

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

USBDEVELKIT DEVELOPMENT KIT V3

CINT W Triple Output Industrial Series

4515DO DESCRIPTION STANDARD RANGES(IN H20)

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Vert-X 05E 5V / % Ub. Application Access control systems Forklift

POWERBOX Defense Line DAA/DAB/DAC Series 150W to several kws DC/DC Conduction Cooled. Preliminary

Transcription:

CE Compliance Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations DESCRIPTION The M5100 series pressure transducers from the Microfused line of MEAS, set a new price performance standard for demanding commercial and heavy industrial applications. This series is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam, and mildly corrosive fluids. The transducer pressure cavity is machined from a solid piece of 17-4 PH stainless steel. The standard version includes a 1/4 NPT pipe thread allowing a leak-proof, all metal sealed system. There are no O-rings, welds or organics exposed to the pressure media. The durability is excellent. The M5100 exceeds the latest heavy industrial CE requirements including surge protection, and is over voltage protected to 16Vdc in both positive and reverse polarity. This product is geared to the OEM customer who uses medium to high volumes. The standard version is suitable for many applications, but the dedicated design team at our Transducer Engineering Center stands ready to provide a semi-custom design where the volume and application warrants. FEATURES APPLICATIONS Heavy Industrial CE Approval Advanced HVAC Systems 100 V/m EMI Protection Refrigeration Systems Reverse Polarity Protection Automotive Test Stands Extended Temperature Range Industrial Process Control 1% Total Error Band Pumps and Compressors Compact Outline Hydraulic/Pneumatic Systems -40 C to +125 C Operating Temperature Range Agriculture Equipment Energy Generation and Management M5100 1/6

STANDARD RANGES Range psig Range Barg 0 to 50 0 to 3.5 0 to 100 0 to 7 0 to 200 0 to 14 0 to 300 0 to 20 0 to 500 0 to 35 0 to 1k 0 to 70 0 to 3k 0 to 200 0 to 5k 0 to 350 0 to 10k 0 to 700 DIN Range Barg 0 to 4 0 to 6 0 to 10 0 to 16 0 to 25 0 to 40 0 to 60 0 to 100 0 to 160 0 to 250 0 to 400 0 to 600 0 to 1000 *Intermediate ranges available upon request. M5100 2/6

PERFORMANCE SPECIFICATIONS Ambient Temperature: 25 C (unless otherwise specified) PARAMETERS MIN TYP MAX UNITS NOTES Accuracy (combined non linearity, hysteresis, and repeatability) -0.25 0.25 %F.S. 1 Isolation, Body to any Lead 1 MΩ @ 25Vdc Pressure Cycles (Zero to Full Scale) 1.00E+7 FS Cycles Proof Pressure 2X Rated Burst Pressure 5X Rated Long Term Stability (1 year) -0.25 0.25 %Span Total Error Band -1.0 1.0 %F.S. 2 Compensated Temperature -20 +85 C Operating Temperature -40 +125 C 3 Storage Temperature -40 +125 C 3 Load Resistance (R L) R L > 100k Ω 4 Bandwidth DC to 1KHz (Typical) Vibration (20 to 200Hz) 50g, 11msec Half Sine Shock per MIL-STD-202F, Method 213B, Condition A Shock (11ms) For custom configurations, consult factory. Notes 1. Best fit straight line at 25 C. 2. TEB includes all accuracy errors, thermal errors, span and zero tolerances. 3. Cable 105 C max. 4. Voltage output. CE Compliance IEC 55022 Emissions Class A & B IEC 61000-4-2 Electrostatic Discharge Immunity (6kV contact/8kv air) IEC 61000-4-3 Electromagnetic Field Immunity (30V/m) IEC 61000-4-4 Electrical Fast Transient Immunity (1kV) IEC 61000-4-5 Surge Immunity (1kV) IEC 61000-4-6 Conducted RF Immunity (10V) IEC 61000-4-9 Magnetic Field Immunity (100A/m) ±20g, MIL-STD-810C, Procedure 514.2, Fig 514.2-2, Curve L M5100 3/6

DIMENSIONS M5100 4/6

1 3 4 2 M5100 5/6

OUTPUT OPTIONS Supply(V) Code Output MIN TYP MAX 3 0.5 4.5V (ratiometric) 4.75 5 5.25 4 1 5V 8 30 5 4 20mA 9 30 6 0 5V 8 30 7 0 10V 15 30 8 1 6V 8 30 ORDERING INFORMATION M5131-000005-300PG Type (G = Gage) Units (P = psi, B = Bar) Pressure Range (See Pressure Range Table) Pressure Port (See Pressure Port Options Table) Specials (nnnnn = Custom Drawing) Connection (See Electrical Connections Table) Output (See Output Options Table) Model The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. M5100 6/6