TMT470L Temperature Transmitter
|
|
- May Anderson
- 5 years ago
- Views:
Transcription
1 Technical information TMT470L Temperature Transmitter OEM components for compact thermometer/cable transmitter. 2/3 or 4-wire Pt100 can be connected. 4 to 20 ma transmitter, programmable via PC. Application Thermometer/sensor manufacturers, resellers and users who need individual compact thermometers or cable transmitters. The components are available as: Transmitter board, individual Stainless steel housing with M12 connector and potted board Cable transmitter with 2x M12x1 connector Benefits at a glance Laser engraving on request, bearing: Company logo Special product name Company headquarters Web address Measuring range Year of manufacture Easy commissioning PC-programmable transmitter for 2/3 and 4-wire Pt100 with 4 to 20 ma output Configuration and visualization with free ReadWin 2000 operating software Can also be ordered with preconfigured measuring range M12 connection for simple electrical connection Breakdown information in event of sensor break or short-circuit, adjustable as per NAMUR NE43 TI136R/09/en
2 Function and system design Measuring principle Measuring system " Caution!! Note! Electronic recording and conversion of Pt100 input signals in industrial temperature measurement. The TMT470L temperature transmitter is available from the factory as: A) An individual transmitter board. B) A complete cable transmitter with 2x M12x1 connector (IP 67). C) A stainless steel housing, with M12 connector and potted board, which the user can make into a compact thermometer by affixing an appropriate process connection (with sensor). The following specifications must be observed if process connections/sensors are welded with the TMT470L stainless steel housing: The temperature in the area of the potting compound and the electronics must not exceed 120 C (248 F) (even briefly). Experience shows that this can be achieved through using a special tool as a heat sink/ dissipator. The welding seam must be gas-tight to ensure that moisture cannot cause internal corrosion. The resistance of the welding seam must be designed for a shock load of at least 7 Newton (exceptions depend on the requirements). Important: The manufacturer of the TMT470L does not accept any responsibility for damage resulting from faulty further processing (warranty exclusion). Measuring principle Measuring range Input Temperature (temperature-linear transmission behavior) Depends on the overall construction Output signal Signal on alarm Maximum load Output (transmitter) 4 to 20 ma or 20 to 4 ma Signal on alarm as per NAMUR NE43 Underranging: Linear drop to 3.8 ma Overranging: Linear rise to 20.5 ma Sensor break; sensor short-circuit: 3.6 ma or 21.0 ma (at settings 21.0 ma, 21.5 ma output is guaranteed) (U power supply - 10 V) / A (current output) Min. current consumption Current limit Switch-on delay 3.5 ma 23 ma 2 s 2 Endress+Hauser
3 Power supply Electrical connection Transmitter board T09-TMT470Lx-04-xx-xx-en-000 Potted board in stainless steel housing with M12 connector T09-TMT470Lx-04-xx-xx-xx-000 T09-TMT470Lx-04-xx-xx-xx-001 Complete cable transmitter with 2x M12 connector Supply voltage Residual ripple U b = 10 to 35 V DC Permitted residual ripple U ss 3 V at U b 13 V, f max. = 1 khz Performance characteristics (transmitter) Maximum measured error 0.1 K (0.18 F) or 0.08% % relates to the set span. The larger value applies. Long-term stability Response time Influence of supply voltage 0.1 K (0.18 F)/year or 0.05%/year Data under reference conditions. % relates to the set span. The larger value applies. 1 s ±0.01%/V deviation from 24 V Specifications in percent refer to the full scale value of the measuring range. Endress+Hauser 3
4 Installation conditions Installation instructions Mounting location, examples T09-TSM470XX xx-xx-001 T09-TMR3xxxx-11-xx-xx-xx-000 General applications Hygienic applications Pipe installation of a complete compact thermometer: Item A: At angle pieces Item B: In smaller pipes, inclined Item C: Perpendicular to the direction of flow L = Insertion length! Note! The insertion length of the compact thermometer can have a substantial influence on the accuracy. If the insertion length is insufficient, heat dissipation via the process connection and the container wall can cause measurement errors. To minimize errors caused by heat dissipation, a minimum insertion length of L min = 40 mm (1.57") is recommended. Environment conditions Ambient temperature limits -40 to +85 C (-40 to 185 F) Storage temperature -40 to +85 C (-40 to 185 F) Electromagnetic compatibility (EMC) CE Electromagnetic Compatibility Compliance The device meets all requirements listed under IEC Amendment 1, 1998 and NAMUR NE21 This recommendation is a uniform and practical way of determining whether the devices used in laboratories and process control are immune to interference with an objective to increase its functional safety. ESD (Electrostatic discharge) IEC kv cont., 8 kv air Electromagnetic fields IEC to 2 GHz 10 V/m Burst (fast transient) IEC kv surge IEC kv sym. Conducted RF IEC to 80 MHz 10 V " Caution! The values indicated can be achieved with appropriate device specifications (housing, cable and assembly). However, they must be verified and documented on the fully assembled transmitter or thermometer. 4 Endress+Hauser
5 Process conditions Process temperature limits In the case of complete compact thermometers, the transmitter must be protected from temperatures above 85 C (185 F) by a neck of appropriate length. -50 to 150 C (-58 to 302 F) without extension neck -50 to 200 C (-58 to 392 F) with extension neck Max. ambient temperature Max. process temperature Without neck With neck To 25 C (77 F) 150 C (302 F) 200 C (392 F) To 40 C (104 F) 135 C (275 F) 180 C (356 F) To 60 C (140 F) 120 C (248 F) 160 C (320 F) To 85 C (185 F) 100 C (212 F) 133 C (271 F) Mechanical construction Design, dimensions Dimensions in mm (inch) Transmitter board T09-TMT470Lx-06-xx-xx-xx-000 Potted board in stainless steel housing T09-TMT470Lx-06-xx-xx-en-001 Cable transmitter, complete Material Transmitter stainless steel housing: SS 304 Endress+Hauser 5
6 Human interface Display elements Operating elements Remote operation No display elements are present directly on the device. The measured value and other displays can be called up using the ReadWin 2000 PC software. No operating elements are present directly on the display. The temperature transmitter is configured by remote operation, without an additional power supply using the ReadWin 2000 PC software. Configuration Configuration kit TXU10-BA with PC operating program (ReadWin 2000). Interface PC interface: TTL/USB connecting cable with plug connector. Configurable parameters Measurement dimension ( C/ F), Measuring range, failsafe mode, output signal (4 to 20 ma / 20 to 4 ma), filter, offset, tag name (8 characters), output simulation. Certificates and approvals CE mark Other standards and guidelines The user can send in an assembled transmitter or thermometer for inspection. The specified standards and guidelines must be observed here. IEC 60529: Degree of protection provided by housing (IP code) IEC 61010: Safety requirements for electrical equipment for measurement, control and laboratory use IEC 61326: Electromagnetic compatibility (EMC requirements) NAMUR Standards working group for measurement and control technology in the chemical industry 6 Endress+Hauser
7 Ordering information Product structure Temperature transmitter TMT470L PC programmable, M12 connector, 4 to 20 ma analog output, 2-, 3- or 4-wire Pt100, fail safe mode as per NAMUR NE43 Programming: 1 via PC 2 blocked Configuration connection: 2 RTD 2-wire 3 RTD 3-wire 4 RTD 4-wire Measuring range: BA CA DA DB DC EA EB EN FC FE FG -50 to 100 C (-58 to 212 F) -40 to 60 C (-40 to 140 F) -30 to 60 C (-22 to 140 F) -30 to 150 C (-22 to 302 F) -30 to 70 C (-22 to 158 F) -20 to 20 C (-4 to 68 F) -20 to 60 C (-4 to 140 F) -10 to 40 C (14 to 104 F) 0 to 50 C (32 to 122 F) 0 to 100 C (32 to 212 F) 0 to 150 C (32 to 302 F) Design: A C D assembled printed circuit board in stainless steel tube, 2xM12-connector, connection RTD: standard in stainless steel tube, welded, M12-connector, without label TMT470L Order code Accessories Coupling Coupling M12x1 for simple user installable assembly of the connecting cable; elbowed; connection to M12x1 housing connector IP 67, PG7 Order number: T09-TTR3xxxx xx-en-000 Coupling Coupling M12x1 for simple user installable assembly of the connecting cable; straight connection to M12x1 housing connector Order number: P01-PMP13xxx-00-xx-00-xx-003 Endress+Hauser 7
8 Connecting cable (preassembled) PVC cable, 4 x 0.34 mm 2 (22 AWG) with M12x1 coupling, elbowed, screw plug, length 5 m (16.4 ft), IP 67 Order number: Core colours: - 1 = BN brown - 2 = WH white - 3 = BU blue - 4 = BK black T09-TMR31xXX xx-xx-001 Configuration kit Configuration kit for PC-programmable transmitters - ReadWin 2000 setup program and interface cable (4 pin plug) for PCs with USB port; with adapter for compact thermometers with M12 thread; Order code: TXU10-BA ReadWin 2000 can be downloaded free of charge directly from the internet at the following address: T09-TMR31xXX xx-xx-000 Documentation Technical information of a complete compact thermometer Easytemp TMR31, TMR35 (TI123R/09/en) Instruments International Endress+Hauser Instruments International AG Kaegenstrasse Reinach Switzerland Tel Fax info@ii.endress.com TI136R/09/en/11.07 FM+SGML6.0 ProMoDo
itemp TMT180 Technical information
Technical information itemp TMT180 Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B Application PC programmable (PCP) Temperature
More informationMinilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values
Technical Information Minilog RDL10 Measured value collector with 2 input channels for storing analog and digital values Application Data storage for termperature, humidity, pressure, flow, level, and
More information4 â RIA251. Technical Information. Process display Digital loop powered display for ma current loops
Technical Information RIA251 Process display Digital loop powered display for 4...20 ma current loops Application Plant and machine construction Control panels Laboratory fittings Process display, monitoring
More informationInstallation Instructions Temperature transmitter TAA /00 06/2011
Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to
More informationOperating manual. Series 450. Compact thermometer. BA01235O/09/en/
Operating manual Series 450 Compact thermometer BA01235O/09/en/01.13 71220279 2 Table of contents 1 Safety instructions... 3 2 Installation... 4 3 Wiring overview... 7 4 Commissioning... 7 5 Operation...
More informationTechnical Information RIA16
TI00144R/09/EN/02.13 71217088 Products Solutions Services Technical Information Field indicator Loop-powered field indicator for looping into the 4 to 20 ma current circuit Application Oil & gas Petrochemical
More informationEasy Analog RNB130. Technical Information. Primary switched-mode power supply
Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power
More informationWirelessHART Adapter SWA70
Technical Information WirelessHART Adapter SWA70 Intelligent WirelessHART interface module for connection to 4...20 ma/hart devices Application WirelessHART Adapter SWA70 is a battery powered, interface
More informationMINI MCR-SL-UI-2I(-SP)(-NC)
Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the
More informationLiquiphant T FTL20. Technical Information. Level limit switch for liquids
Technical Information Liquiphant T FTL0 Level limit switch for liquids Application The Liquiphant T FTL0 is a level limit switch for all kinds of fluids and is used in tanks, containers and pipelines.
More informationTechnical Information RIA16
TI00144R/09/EN/04.14 71251374 Products Solutions Services Technical Information RIA16 Field indicator Looppowered field indicator for looping into the 4 to 20 ma current circuit Application Oil & gas Petrochemical
More informationMINI MCR-SL-PT100-UI(-SP)(-NC)
Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection
More informationPCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1
Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10
More informationJUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits
Data Sheet 4000 Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology Brief description
More informationNOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI
NOVOTURN Multiturn-Sensor non-contacting Series RSM2800 digital SSI, SPI Special features True Power On System: counts turns even when not powered. Patented non-volatile technology does not require gears
More informationTHM501 PT100 MODBUS TEMPERATURE TRANSMITTER
THM501 PT100 MODBUS TEMPERATURE TRANSMITTER INTRODUCTION The TekOn Electronics In Head 2-Wire Temperature Transmitters are specifically designed to meet the most rigorous requirements of operation in the
More informationNOVOTURN Multiturn Sensor non-contacting Series RSM2800 analog
NOVOTURN Multiturn Sensor non-contacting Series RSM2800 analog Special features non-contacting, magnetic long life electr. angle 720 up to 5760 in 360 -steps available (equates 2... 16 turns) continuous
More informationPressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2
Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet
More informationM5100 Heavy Industrial Pressure Transducer
CE Compliance Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations DESCRIPTION The M5100 series pressure transducers from the Microfused line of MEAS, set a new price
More informationFlow simulation system PROline FieldCheck
Technical Information TI 059D/06/en 50101259 Flow simulation system PROline FieldCheck Simulation and verification of flow measuring systems Features and benefits Checking the function and deviation in
More informationJUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits
sales@jumo.co.uk info.us@jumo.net Page /0 JUMO MIDAS C08 OEM Pressure Transmitter Basic Applications compressors machinery and plant engineering industrial pneumatics commercial vehicles building technology
More informationEngyVolt RV12 and RV15
Technical Information EngyVolt RV12 and RV15 Multifunctional electrical energy meters for top-hat rail installation or panel mounting Application For measuring voltage, frequency, current, power, as well
More informationThis data sheet is only valid in association with the IL SYS INST UM E user manual.
Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is
More informationBTL6-A_10-M -A1-S115. Data Sheet. english
BT6-A_10-M -A1-S11 english Data Sheet Balluff GmbH Schurwaldstrasse 9 76 Neuhausen a.d.f. Germany Phone +49 (0) 71 8/1-0 Fax +49 (0) 71 8/0 10 Servicehotline +49 (0) 71 8/1-70 E-Mail: balluff@balluff.de
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationNI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O
DATASHEET NI REM-11115 Analog Output Module for Remote I/O Four voltage output ranges to choose from (0 V to 10V, ±10V, 0 V to 5 V, and ±5V) Two current output ranges to choose from (0 ma to 20mA, 4 ma
More informationGFK-2415A March Type of sensor connection
VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by
More informationTechnical data. General specifications. Indicators/operating means
Release date: 08-0-08 0:7 Date of issue: 08-0-09 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
More informationNOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental
NOVOHALL Rotary Sensor non-contacting Series RSC2800 digital SSI, SPI, Incremental The contactless sensor utilizes the orientation of a magnetic field for the determination of the measurement angle. The
More informationDCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor
DCT 5 Industrial Pressure Transmitter with RS85 Modbus RTU Stainless Steel Sensor accuracy according to IEC 60770: : 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar output
More informationLMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.
LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:
More informationTHERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA
Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure
More informationDMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure
More informationOperating instructions Electronic pressure sensor. PM205x /01 09/2011
Operating instructions Electronic pressure sensor PM205x 706071/01 09/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Applications...4
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99
More informationSuitable for detecting transparent films or transparent bottles
Ultrasonic Sensor Suitable for detecting transparent films or transparent bottles Reliable detection of transparent objects The sensor reliably detects transparent films or transparent objects. Only 16
More informationIsolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Linearized RTD Input 5B34 FEATURES Amplifies, Protects, Filters, and Isolates Analog Input. Linearize a wide variety of 2 & 3 wire RTDs. (True 4-wire RTD measurements are provided by the 5B35).
More information4 5 â Ó. Flow switch Flowphant T DTT31, DTT35. Technical information
Technical information Flow switch Flowphant T DTT31, DTT35 Flow switch for safe monitoring of mass flow and temperature in industrial processes Application Flow switch for monitoring and displaying relative
More informationXXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12
Characteristics Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12 Complementary Enclosure material Front material Supply voltage limits Function available [Sa] assured operating
More informationProline Prowirl 72, 73
Functional Safety Manual Vortex flow measuring system with 4 20 ma output signal Application Monitoring of maximum and/or minimum flow in systems which are required to comply with particular safety system
More informationTemperature measurement TER8 Front-flush and low-invasive resistance thermometers
Product highlights 3-A fulfillment without elastomers Front-flush or immersed types Accurate reading independent on ambient temperature Fast response time Hermetically sealed towards process Capable of
More informationTechnical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 0--9 07:6 Date of issue: 0-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
More informationAssembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug
Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free
More informationProximity sensors, block design
Proximity sensors, block design Proximity sensors, block design Product range overview Measuring principle Version Type Mounting Switching element function Switching Electrical connection N/O contact N/C
More informationOperating instructions Evaluation system for flow sensors VS / / 2013
Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200F, CPU 1214 FC, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY 125 KB General information
More informationAI561 Analog Input Module
Ordering Data DATA SHEET AI561 Analog Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1101 AI561, analog input module, 4 AI, U/I 1TNE 968 901 R3101 1TNE 968
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet *** SPARE PART*** SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General
More informationRA33. Technical Information. Batch controller For the batching and dosing of mass and volume
Technical Information RA33 Batch controller For the batching and dosing of mass and volume Highlights Swift commissioning and easy operation with plaintext display in selectable language Valve control
More informationMINI MCR-SL-UI-REL(-SP)
Configurable Threshold Value Switch Data Sheet 11/2004 Method of Operation The configurable 3-way threshold value switch MINI MCR-SL-UI-REL(-SP) is used to control and monitor analog standard signals.
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200F, CPU 1215 FC, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24VDC; 10 DO 24V DC 0.5A; 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
More informationM7100 Pressure Transducer
Pressure Transducer Performance standard to on and off highway engines and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless Steel wetted
More informationIsolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW
Isolated Current Output 5B39 FEATURES Converts a High-level analog input voltage into a floating proportional output current. Output current of 4 to 20 ma or 0 to 20 ma across loads from 0Ω to 750Ω. High
More informationNOVOHALL Rotary Sensor touchless transmissiv. Series RFC4800 SSI, SPI, Incremental
NOVOHALL Rotary Sensor touchless transmissiv Series RFC4800 SSI, SPI, Incremental The sensor utilizes the orientation of a magnetic field for the determination of the actual position. Therefore, a magnet
More informationWIRELESS SERIES Single or Dual Axis MEMS Inclinometer
The 2GIG Industrial RF Wireless Inclinometer is engineered to work for all applications. The internal software provides unlimited programming capabilities. It offers the best operating temperature range,
More informationLineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN
LineMaster 100 Continuous-line Recorder 10/43-1.10 EN 1 to 4 measuring channels Format 144 mm x 144 mm; installed depth 250 mm Combined chart unit for roll chart (32 m) or folded chart paper (16 m) Measuring
More informationFlow measurement FlexFlow PF20S Flow sensor for industrial applications
Product highlights Parallel measurement of flow and temperature Flow measurement independent of the mounting position Large measuring range up to 400 cm/s Measurement at high media temperatures up to 125
More informationIndustrial Power Supplies
75-600 Watt Features Switch mode power supplies for DIN-rail mounting 4 power ranges with 3, 6, 12 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise EMI complies
More informationHIT/HIX HART Isolator
/ Isolator December 2017 Description Moore Industries Isolators provide highly economical solutions to common and costly problems that plague many of today s smart process loops. Protect and enhance your
More informationAO561 Analog Output Module
Ordering Data DATA SHEET AO561 Analog Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R1201 AO561, analog output module, 2 AO, U/I 1TNE 968 901 R3102 Terminal
More informationPressure sensor For highest pressure applications to 15,000 bar Model HP-2
Pressure Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 WIKA data sheet PE 81.53 for further approvals see page 6 Applications Test bench construction Water jet cutting High-pressure
More informationVariTrans P Standard-Signal Isolators
VariTrans Standard-Signal Isolators Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our works (carriage and insurance paid by sender). The professional
More informationRoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e
The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via
More informationPHOENIX CONTACT - 05/2007
Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007
More informationTechnical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means
Model Number Single head system Features IO-link interface for service and process data Programmable via DTM with PACTWARE Switch output and analog output Selectable sound lobe width Synchronization options
More informationNOVOHALL Rotary Sensor non-contacting. Series RSX-7900
NOVOHALL Rotary Sensor non-contacting Series RSX-7900 Special features very robust design to extreme environmental conditions high shaft load 300 N non-contacting, magnetic measuring angles up to 360 in
More information4 â Active barrier RN221N with optional HART diagnosis. Technical Information
Technical Information Active barrier with optional HART diagnosis Active barrier with power supply for safe separation of 4 to 20 ma current circuits Application Galvanic isolation of 4 to 20 ma current
More informationPressure switch RE B/ Type HEDE10.../1/ Operating instructions
Pressure switch Type HEDE10.../1/ RE 30276-B/10.10 Replaces: 06.10 Operating instructions 2/20 Bosch Rexroth AG HEDE10.../1/ RE 30276-B/10.10 Contents 1 Overview of menu...3 2 Safety note... 4 3 Operating
More informationPaperless recorder Ecograph
Technical information TI075R/09/en Mat. no.: 51001521 Paperless recorder Ecograph Economical and time saving recorder operates without the need for paper or pens and is unusually simple to operate Application
More informationData Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.
Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and
More informationVariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.
Universal Isolation Amplifiers The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply. The Housing At a width of just 12.5 mm, the modular housing with pluggable
More informationDimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31
OBEM-R00-SEP-IO-V Dimensions. 8.7. 7..9. M (x).. ø... 0 9.9 7. 7. Release date: 08-06-08 :0 Date of issue: 08-06-08 80998_eng.xml Model Number OBEM-R00-SEP-IO-V Thru-beam sensor with -pin, M8 x connector
More informationInstallation instructions Inclination sensor EC2019 EC / / 2013
Installation instructions Inclination sensor UK EC219 EC245 739215 / 3 1 / 213 Inhalt 1 Safety instructions 3 2 Mounting 4 3 Electrical connection 4 4 Dimensions 4 5 Technical Data 5 6 Characteristics
More informationOperating manual Thermophant T TTR 31, TTR 35. Temperature switch. KA174R/09/en/ Release
Operating manual Thermophant T TTR 31, TTR 35 Temperature switch KA174R/09/en/10.04 51008032 Release 01.00.00 Thermophant T Table of contents 1 Safety instructions........... 3 1. 1 Designated use......................
More informationACW4 SSI SSI ABSOLUTE SINGLE TURN MODULAR
ACW4 SSI SSI ABSOLUTE SINGLE TURN MODULAR Features With its two-part design, the ACW4 absolute single-turn offers maximum flexibility for installation Rugged and excellent resistance to shock and vibration
More informationDI561 Digital Input Module
Ordering Data DATA SHEET DI561 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2101 1TNE 968 901 R3101 1TNE 968 901 R3103 1TNE 968 901 R3105 DI561, digital
More informationDisplay. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB Display with display Supply
More informationGeneral information. Display. Supply voltage. Input current
Datasheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Engineering
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory
Data sheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40...+70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG40-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC 10 DO 24 V DC 2 AI 0-10V DC, POWER
More informationEF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!
1215 PHOTO PHOTO SAFETY USE SERIES Related Information General terms and conditions... F- General precautions... P.1595 guide... P.1155~ MEASUREMENT panasonic.net/id/pidsx/global Continuously check invisible
More informationGeneral information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes
Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:
More informationWG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.
Modular Housings for Hazardous Areas For transmission of 0(4)... 20-mA signals from hazardous areas or supply of intrinsically safe 2-wire transmitters. The Task The power supply/isolator is used to supply
More informationMiniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm
Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic
More informationIndustrial Power Supplies
50-600 Watt Features Switch mode power supplies for DIN-rail mounting 6 power ranges with 2, 3, 6, 12, 20 and 24 A output current (24 VDC models) Selectable 115/ 230 VAC input Very low ripple and noise
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationstandard, short, preferential, top
ipf electronic gmbh Kalver Straße 27 standard design short design preferential series top series standard, short, preferential, top norm sensing ranges, increased sensing ranges 1100 1 2 1100 norm sensing
More informationVoltage Current Front-mounting bracket
Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction
More informationOperating instructions Memory plug E /02 11/2011
Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationTechnical Data Photoelectric Sensors
Series M18 Overview of diffuse reflective and retro reflective sensors Type OT, plastic housing RT 1mm fix. 65578194 65572194 65578182 65572181 RT 3mm var. 65578195 65572195 65578183 65572185 RT 5mm var.
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationGeneral information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering
More informationTemperature Measurement SITRANS TS300
Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Dimensional drawings Cable gland M1x1.5 for cable Ø 3... 6.5 (0.1... 0.6) Ø 60 (.36) Ø d = N + H 1 Ø 50.5 (1.99) U X H 1 N H Ø
More informationLevel sensor Stainless steel version Model RLT-1000, for industrial applications
Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring
More informationDisplay. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware
More informationVariTrans P The Problem The variety of tasks results in a large number of different devices.
Universal Isolation Amplifiers The Multimeter among the isolation amplifiers. With 480 switchable calibrated ranges and broad-range power supply. The broad-range power supply for all common supply voltages
More information