Similar documents
Product Discontinuation Notices. Discontinuation Notice of open-circuit time delay relay RD2P-30

TeSys protection components

SafeC S to MSR127 Conversion

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

Installation and User Guide

CDW7. Standard: IEC Application. Standard and certification. International standard: IEC Approved certification: CB, CE, KEMA

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

STC7D. Digital Time Clock for TRC500 & TRC800. Installation, Operation, and Maintenance Manual

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

ATS CONTROLLER OPERATING MANUAL

Astronomical time switches

PM Series Power Meter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

ict contactors EN 61095, IEC 1095 Interference

IC-1504 / IC-1508 / IC-1516

LCD Drawer User Manual

ProScale LCD Readout Quick Start Guide

TeSys IEC Contactors and Overload Relays

Pico Accessories. Memory Modules. This section provides information on various accessories.

Supplementary operating instructions for your air curtain system Controller TMC 500

Mini Contactors & Overloads

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

INSTALLATION INSTRUCTIONS

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RW-E. Overloads. Solid-State Overload Relays. Standard Features

WMS SUPPLEMENTARY PROTECTORS

RTD-500 Precision RTD Simulator. Operations Manual.

Semi flush-mounted room temperature controllers with LCD

Control instruments GUARDIAN 2 - GUARDIAN 3

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

3RA13, 3RA14 Contactor Assemblies

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

JOCKEY FIRE PUMP CONTROL MODEL: FPC Series

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

H202 中文 GB Version 1

HDZ6 Contactor Relay

MOD. KBC HEAD KONTAX BATCH CONTROLLER

78 Series Electromechanical Relay Selection Guide

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

ECL Comfort V a.c. and 24 V a.c.

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Multifunction Calibrator

Switching module for AC V and up to three load stages, with manual switching

Electronic earth leakage protection relay

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

Semi flush-mounted room temperature controllers with LCD

Installing and Configuring Rialto Analytic Appliances

I. PRODUCT DESCRIPTION

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

FS-21.doc Status Filter Control FS-21. EasyRange

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

SMARTSCAN INFORMATION

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

Simple solutions for control technology

Temperature controller Ducted systems

DALI RM 8/16. Datasheet. DT7 Relay Module. Relay Module for the integration of non-dimmable ballasts in DALI lighting systems (DT7)

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

E1 Plus Electronic Overload Relay

THREE PHASE ELECTRONIC WATT-HOUR METER VSE3T

DPC Warning. ! Do not pull the cable. Water Pump Digital Pressure Controller Installation and Operation Manual.

BOX TRANSDUCER SMALL SIZED AC TRANSDUCER 90 SERIES

641G-001A PRINTER KIT INSTRUCTIONS

AC OPERATION BATTERY OPERATION RADIO OPERATION Note : FM STEREO INDICATOR ANTENNAS BASS BOOST AUXILIARY (AUX) MODE

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

Safety Temperature Limiter TT-STL 50

MSR178DP. Description. Features. Specifications

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

SAFETY COMMAND DEVICES

Non-communicating room controllers

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW

Achieve Easy Plug & Play 1/ 6

Allen-Bradley Drives

Automatic Transfer Switch OTM_C_20D. Installation and Operation Instructions

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

Portable Robust Easy to use. CD / MP3 player with 6 built-in headphone sockets USER GUIDE. Primary ICT Ltd -

MCX08M2 Programmable controller

Section 4 Ground-Fault Protection Devices

EYE 200: DDC single-room controller, ecos200

Short Instructions CG-S / IP-Router

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Specification Voltage Limiting Device

Compressor Controller MAM 890

E-STOP relays, safety gate monitors

Transcription:

ATP1006-4 TIME SWITCH Instruction Manual 1 Purpose and Scope ATP1006-4 TIME SWITCH of Belling apparatus, control circuit with AC 50Hz/60Hz, rated control power voltage of 220V at most and rated working current of 3A at most, turn on or off the circuit with a predetermined program, for example: As a school, factory bell controller. The product complies with the requirements of IEC 60947-5-1 standard. 2 Normal Operating Condition and Installation Condition 2.1 Rated control power voltage: AC (50Hz): 220V. 2.2 Conventional thermal current: 16A. 2.3 Rated working current (Ie): AC-15 220V 3A. 2.4 Timing error: 1s/d. 2.5 Bell set:40 groups. 2.6 Belling time:1s~99s 2.7 Electric endurance: 10,000 times. 2.8 Installation method: 35DIN Rail mounting or Screws. 3 Outline, Installation Dimension and Wiring Method 3.1 Outside dimension and installation dimension see Figure 1. a) ATP1006-4 outside dimension b) ATP1006-4 installation dimension Figure 1 Outside dimensions and installation dimensions of ATP1006-4 3.2 Wiring method 3.2.1 Direct control method Power of the controlled appliance is supplied in single-phase, of which the working current is no more than the rated value of this switch. Direct control method may be adopted, wiring method see

Figure 2; for light load with great starting current impact, please adopt AC contactor expansion control method. 3.2.2 Single-phase expansion method The controlled appliance is power supplied in single-phase, of which the working current exceeds the rated value of this switch. Please adopt AC contactor expansion control method, see Figure 3. 3.2.3 Three-phase operating method Power of the controlled appliance is supplied in three-phase, so external AC contactor is required hereof. a) The coil voltage of the controlled contactor is AC 220C 50Hz, so its wiring method sees Figure 4; b) The coil voltage of the controlled contactor is AC 380V 50Hz, so its wiring method sees Figure 5. Figure 2 Direct single-phase controlled wiring diagram Figure 3 Single-phase expansion controlled wiring diagram Figure 4 Three-phase controlled wiring diagram (220V for contactor coil) 4 Setting and Use Figure 5 Three-phase controlled wiring diagram (3800V for contactor coil) This product panel is set with five buttons, namely MD (mode), R (recall), (-)and (+). 4.1 Setting process for Time Switch of Belling apparatus parameters (see Figure 6) (left-shift),

4.2 Setting processes are as follows: 4.2.1 Current date and current time adjustment 4.2.2.1 Press button MD for 3s to cancel the keyboard lockout, so that LOCK may disappear, Press to select the adjusted position and press - and + to plus and minus, so as to adjust the display time to the current time, see Figure 7. Figure 7 4.2.3 Timing parameters setting 4.2.3.1 After finish operation 4.2.2, press MD + R to Setting rang the bell time, see Figure 8,It means long rang the bell for 15 seconds. After setting, press "MD" key to exit.

4.2.3.2 Set 1ON (first group of bell) time: press the "MD" key to enter first bell time set, respectively, according to turn into minutes, hours, weeks mode setting, then set bit flashes, such as Figure9, press the "+" " - " buttons to set Working clock, The days will work on behalf of the week mode of light. After setted,press "MD" key to enter 2ON (second group of bell) time set. 4.2.3.3 Set 2ON (second group of bell) time:same steps as 4.2.3.2, such as Figure10. 4.2.3.4 Repeat the above steps to Complete all bell time settings,press the "R" key to elimination the Groups do not need,then LCD display, As shown in Figure11, again press the "R" button can recall the setted. 4.2.4 When the setting is completed, press the "MD" key for 3 seconds to enter the clock state, Time Switch of Belling apparatus automatically locked "LOCK" character, as Figure12 shows 4.3 After locking the switch, press "MD" and "+" at the same time to switch manual/automatic status. Continuously press them together, the screen will show AUTO OFF, ON, ON AUTO and OFF successively, see Figure 13. When the circuit shall be on and off temporarily in the process of operation, the combination buttons can be used to adjust the switch to ON and OFF; if the time switch shall work automatically according to the set time, the combination button shall be used to adjust the switch to ON AUTO, then the time switch may work as set, so as to achieve automatic control.

Figure 13 Manual/automatic time switch setting process 5 Notice 5.1 The switch into the line can only be connected to AC220V power supply, do not access the other power 5.2 If you can not achieve automatic control function,check the lower right corner of the screen (AUTO) is right shown? 5.3 The internal battery can only provide the LCD screen display and settings, such as A1, A2 terminal auxiliary power missed, is unable to drive the relay output. 5.4 If the user find errors in the products,through short 3, 4 terminal reset,after reset procedures need to set again. 5.5 When the end of the product life, please recycle work product or its components, for not recycled parts, please dispose of, to protect our environment.