Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Similar documents
C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

CERTIFICATE OF COMPLIANCE

Certificate of Compliance

File E Project 00ME December 18, 2000 REPORT COMBINATION CONTROLLERS. Siemens AG Amberg, Germany

SIMOCODE 3UF Motor Management and Control Devices

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

TeSys IEC Contactors and Overload Relays

Allen-Bradley Bulletin 100 Contactors

CERTIFICATE OF COMPLIANCE

C E R T I F I C A T E O F C O M P L I A N C E

Overload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview

Solid-State Contactors

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Large Frame IEC Contactors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

3RA13, 3RA14 Contactor Assemblies

XT IEC Power Control Contactors, Starters and Overload Relays

SENTRON 3VL Molded Case Circuit Breakers

CERTIFICATE OF COMPLIANCE

Cert.Record No _0_000, Class No , DQD No 557 Rev SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM

SIRIUS Motor Management and Control Devices

Mini Contactors & Overloads

LOGO! logic modules LOGO! basic and expansion modules

Siemens.com/industrial-controls

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

Monitoring and Control Devices

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Load Feeders and Motor Starters for Use in the Control Cabinet

UL TEST REPORT AND PROCEDURE

Power Management System. Multifunction Measuring Instruments

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Electrical Components for the Railway Industry. SIRIUS Relays 3RP, 3RS, 3TX

SIRIUS 3RB2 Solid-State Overload Relays

Siemens AG up to 12 up to 25 up to 50 up to 100 up to 200 up to S12 Terminal brackets for stand-alone

MOTUS ContactronControl. Less is more.

sirius Switching. Protecting. Starting. SIRIUS Product Overview

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

Siemens AG SIMOCODE 3UF Motor Management and

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

SIRIUS Modular System

Siemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry.

Motor protection relays

Load Feeders, Motor Starters and Soft Starters

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

Miniature Circuit Breakers and Supplementary Protectors. Contents

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

9926 Series Branch Rated Circuit Breakers AC Version

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

Cert.Record No _C_000, Class No , DQD No 548 Rev

3 Pole Contactors with AC operating coils

Protection Equipment

For additional PowerFlex 4M data and general drive information, refer to the following publications:

Revolutionizing control wiring

Solid-State Switching Devices

Power Management System. Measuring Devices for Power Distribution

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

Monitoring Relays. SIRIUS 3UG Monitoring Relays for Stand-Alone Installation. Line monitoring. 8/62 Siemens IC Overview

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

Circuit Breakers Type CTI 25M, CTI 45MB

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

SIRIUS modular system

System-based switching, protecting, starting. SIRIUS Modular System. sirius

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

SITOP in the SIMATIC Design

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Miniature Circuit-Breaker IEC Series 8562

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.

SIRIUS modular system

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

SSW06. Soft Starters.

UL TEST REPORT AND PROCEDURE

SACE Emax 2 Specification guide

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

IEC Power Control Overload Relays

Control Circuit Components

C E R T I F I C A T E O F C O M P L I A N C E

Fast Bus Busbar System

Power supplies CP-E, CP-S and CP-C range NEW! CP-E Range

Fast Bus Fast Bus Busbar System

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Industrial Controls Product Catalog 2017

Transcription:

Issued to: Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that Auxiliary Devices representative samples of 3UF70 followed by 0 or 1 followed by 0 followed by 1A, followed by B or U, followed by 0, may be followed by suffix numbers and/or characters. 3UF71 followed by 0 or 1 followed by 0, 1, 2, 3 or 4 followed by 1, followed by A or B, followed by A, may be followed by suffix numbers and/or characters. 3UF73 followed by 0, 1, 2, or 3, followed by 0 or 1 followed by 1A followed by B or U, followed by 0, may be followed by suffix numbers and/or characters. Models continued on next page Have been investigated by Underwriters Laboratories in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Industrial Control Equipment, UL 508 and CSA-C22.2 No. 14 Additional Information: See UL On-line Certification Directory at WWW.UL.COM for additional information.

Certificate Number 20111219-E44653 Page 2 of 11 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. MODELS (continued): 3UF7150-1AA0-0, 3UF7200-1AA00-0, 3UF7922-0AA00-0, 3UF7930-0AA00-0, 3UF7931-0AA00-0, 3UF7932-0AA00-0, 3UF7933-0AA00-0, 3UF7900-0AA00-0, 3UF7920-0AA00-0, 3UF7950-0AA00-0, 3UF7400-1AA00-0, 3UF7500-1AA00-0, 3UF7700-1AA00-0, 3RA6935-0A, 3RA6936-0A, 3RA6933-0A, 3RA6933-0B, 3RA2711-0EE11. 3RB22, 3RB23, or 3RB24 followed by 8, followed by 3, followed by -4A, followed by A or C, followed by 1. 3RB29 followed by 0, 4, 5 or 6 followed by 6 followed by -0 or 2, followed by B, D, E, F, J, M, T or W, followed by G or H, may be followed by suffix numbers and/or characters. 3RB298, followed by 4, 5 or 7, may be followed by suffix numbers and/or characters GENERAL: 3UF7: The 3UF70 are adjustable ambient compensated electronic overload relays with external current unit type 3UF71 of the open type. The devices are intended for use in combination with this manufacturers contactors or for separate mounting. The 3UF71 are three phase current/voltage measuring modules and decoupling modules of the open type. The devices are intended for use in combination with this manufacturers electronic overload relay 3UF70 to provide the current/voltage to the basic unit. The 3UF73, 3UF74, 3UF75 and 3UF77 are digital modules, analog modules, ground fault modules and temperature modules of the open type. The devices are intended for use in combination with this manufacturers electronic overload relay 3UF70 to link additional inputs and outputs to the basic unit. Model 3UF75 is intended for use with summation current transformer type 3UL22. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL.

Certificate Number 20111219-E44653 Page 3 of 11 The 3UF732 and 3UF733 modules are used for bus communication applications and can be monitored. The devices are intended for use in combination with this manufacturers electronic overload relay 3UF70 in motor branch applications to protect, inform via bus and/or switch of the motor on overload conditions. The 3UF72 are operator modules, type 1 and 12. The devices are intended for installation in cubical doors, can only be plugged into the 3UF70. 3RA6935-0A: Model 3RA6935-0A is an operator module, type 1 and 12. These devices are intended for installation in cubical doors, can be plugged into the 3RA6 or 3RA27. 3RB2: The 3RB22 and 3RB23 are adjustable ambient compensated electronic overload relays with external current measuring modules unit type 3RB29 of the open type. The devices are intended for use in combination with this manufacturers contactors or for separate mounting. The 3RB24 is the same device as 3RB22 or 3RB23 but with IO-Link communication interface. The 3RB29 are three phase current measuring modules of the open type. The devices are intended for use in combination with this manufacturers electronic overload relay 3RB22 or 3RB23 to provide the current to the basic unit. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL.

Certificate Number 20111219-E44653 Page 4 of 11 RATINGS: 3UF70 (Basic Units): 5 setting ranges depending of the used Current measuring unit 3UF71, 8 setting classes. Surrounding ambient air temperature 60 C Auxiliary contacts: B300 / R300 Control voltage: 24 V dc 110 to 240 V ac/dc Tripping current: 125 percent of dial setting Setting classes: 5, 10, 15, 20, 25, 30, 35 or 40 3UF71 (Current and/or voltage sensing unit): 600 V a.c.; 3 ph; 50/60 Hz; 5 setting ranges. Setting ranges and short circuit ratings: Setting range Fuse*, Comb.Mot.Ctrl. or Circuit Breaker Short circuit Voltage 0.3 to 3.0 A max. 10 A 100 ka 600 V 2.4 to 25 A max. 100 A 100 ka 600 V 10 to 100 A max. 400 A 100 ka 600 V 20 to 200 A max. 600 A 100 ka 600 V 63 to 630 A max. 2000 A 100 ka 600 V *Different Class fuses can be used Short circuit ratings apply to both, overload relays and overload relays used with contactors. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL.

Certificate Number 20111219-E44653 Page 5 of 11 3UF73 (Digital Module): Accessories: Auxiliary contacts: B300/R300 Control voltage: 24 V dc 110 to 240 V ac/dc 3UF74 (analog module), 3UF75 (Ground fault module) and 3UF77 (Temperature module): Low voltage, low current. 3UF72, 3RA6935-0A (Operator module) and door adapter 3UF7920-0AA00-0 (Door adapter): Type 1 and 12 3UF732 and 3UF73 : Auxiliary contacts: B300/R300 Control voltage: 24V dc 110 to 240 V ac/dc Air surrounding temperature: 60 C 3RB22, 3RB23, and 3RB24 (Basic Units): 4 setting ranges depending on the used Current measuring unit 3RB29, 4 setting classes. Surrounding ambient air temperature 60 C Auxiliary contacts: B300 / R300 Control voltage: 24 V to 240 V ac/dc Tripping current: 125 percent of dial setting Setting classes: 5, 10, 20 or 30 Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL.

Certificate Number 20111219-E44653 Page 6 of 11 3RB29 (current sensing unit): 600 V a.c.; 3 ph; 50/60 Hz; 8 current ranges. Setting ranges and short circuit ratings: Current range Fuse*, Comb.Mot.Ctrl. or Short circuit Voltage Circuit Breaker 0.3 to 3.0 A max. 10 A 100 ka 600 V 2.4 to 25 A max. 100 A 100 ka 600 V 10 to 100 A max. 400 A 100 ka 600 V 25 to 150 A max. 600 A 100 ka 600 V 20 to 200 A max. 600 A 100 ka 600 V 150 to 300 A max. 800 A 100 ka 600 V 160 to 567 A max. 1600 A 100 ka 600 V 63 to 630 A max. 2000 A 100 ka 600 V *Different Class fuses can be used Short circuit ratings apply to both, overload relays and overload relays used with contactors. NOMENCLATURE BREAKDOWN: 3UF70 0 0-1A B 0.. I II III IV V VI VII 3UF70 - Basic unit I IV. Functions 0 - standard version 1 - extended version 0 - Basic type Communication -1A - Profibus DP Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL.

Certificate Number 20111219-E44653 Page 7 of 11 V. Rated control voltage B - 24 V d.c. U - 110 to 240 V a.c. / d.c. VI. V Input and Output 0-4 inputs and 3 outputs.. -.. 3UF71 0 0-1 A A.. I II III IV V VI VII 3UF71 - Current measuring unit I IV. Functionality 0 - Current measuring module 1 - Current and voltage measuring module Current range 0-0.3 to 3 A 1-2.4 to 25 A 2-10 to 100 A 3-20 to 200 A 4-63 to 630 A Manufacturers Identification -1 - Standard V. Construction of Current transformer A - straight-through current transformer B - current transformer with bus bars Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL.

Certificate Number 20111219-E44653 Page 8 of 11 VI. V Firmware A - Standard Manufacturers Identification.. - Standard 3UF73 0 0-1A B 0 0-0 I II III IV V VI VII 3UF73 - Expansion Module, 4 inputs, 2 outputs I IV. Type of outputs 0 - monostable output contacts 1 - bistable output contacts 2 - fail-safe digital module, DM-F local 3 - fail-safe digital module, DM-F PROFIsafe 0 - screw terminal 1 - spring terminal -1A - basic type V. Rated control voltage B - 24 V d.c. U - 110 to 240 V a.c. / d.c. VI. V 0-4 inputs / 2 outputs 0-0 - manufacturers identification Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL.

Certificate Number 20111219-E44653 Page 9 of 11 Accessories for 3UF7: 3UF7150-1AA00-0: Decoupling Module 3UF7200-1AA00-0: Operator Module for 3UF7 3UF7930-1AA00-0, 3UF7931-1AA00-0, 3UF7932-1AA00-0, 3UF7933-1AA00-0: Flat Cable to connect basic unit, current and voltage sensing units, expansion modules and operator modules. 3UF7400-1AA00-0: Analog module 3UF7500-1AA00-0: Ground fault module 3UF7700-1AA00-0: Temperature module 3UF7900-0AA00-0: Memory module 3UF7910-0AA00-0: Address module 3UF7920-0AA00-0: Door adapter 3UF7950-0AA00-0: Cover for connector 3UF7922-0AA00-0: Adapter for operator panel Accessories for 3RA6 Compact Starter or 3RA27 communication module: 3RA6935-0A: Operator Module for 3RA6/3RA27 3RA6936-0A: Enabling Module 3RA6933-0A: Cable for connection from the operator Module to 3RA6 3RA6933-0B: Cover for connector 3RA2711-0EE11: Cable for connection from the operator Module to 3RA27 3RB22 0 3-4A A 1 I II III IV V VI 3RB22 - Basic unit with monostable relay output 3RB23 - Basic unit with bistable relay output 3RB24 - Basic unit with monostable relay output and IO-Link interface. Size 8 - For all Sizes Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL.

Certificate Number 20111219-E44653 Page 10 of 11 I IV. 3 - Basic type Class settings -4A - adjustable V. Terminals A - Screw terminals C - Spring terminals VI. Mounting 1 - Separate Mounting 3RB29 0 6-2 B G.. I II III IV V VI VII 3RB29 - Current measuring unit I IV. Size 0 - Size S00, S0, S2 or S3 4 - Size S2 5 - Size S6 6 - Size S10/S12 Manufacturers Identification 6 - standard Manufacturers Identification -0 - without signal processing -2 - with signal processing Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL.

Certificate Number 20111219-E44653 Page 11 of 11 V. Current range B - 0.3 to 3 A D - 2.4 to 25 A E - 25 to 150 A (without signal processing) F - 150 to 300 A (without signal processing) J - 10 to 100 A M - 160 to 567 A (without signal processing) T - 20 to 200 A W - 63 to 630 A VI. Construction of Current transformer G - straight-through current transformer H - current transformer with bus bars V Manufacturers Identification.. Standard - - omitted Accessories for 3RB2: 3RB298 4.. I II III 3RB298 - Accessories for 3RB2 I Size 4 - sealing cap 5 - extension module 7 - Flat Cable to connect basic unit and current sensing unit Suffix Letters and/or numbers specifies commercial variations.. - any commercial variations Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL.