Analog input module. Data sheet. for MULTICAL 603

Similar documents
M-Bus Modules. Data sheet. for MULTICAL 403

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Wired M-Bus Modules. Data sheet. for MULTICAL 403 and 603

BACnet MS/TP-module. Data sheet. for MULTICAL 403 and 603

Wireless M-Bus modules for MULTICAL 403 & 603

RS-485 module. Data sheet. for electricity meters

LON-module for MULTICAL 601

M-Bus Master. Data sheet. MultiPort 250D/L

M-Bus Master MultiPort 250D/L

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

/ Type approved according to:

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

Instruction Manual. T3110 T3110L T3110Ex

Gateway, routing data between sensors and cloud

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

DTM Distributed Transmitter Monitor

LBTKG-CO462 TKG-CO2 SERIES. Carbon Dioxide Detector/Controller. Features. Professional Design & Manufacture CO 2 Controllers.

Gateway, routing data between sensors and cloud

Precision digital measuring device PHYSICS 51

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

MULTITERM Pro G2 and G3 RF

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

Neon pr. ph/ ORP measurement. Applications. Description

Interface description. Kamstrup HAN-NVE interface description

CMi- box. M-Bus Metering Gateway for Mobile Network GSM/GPRS TCP/IP. CMi-Box

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

T3311, T3313, T3411 T7310, T7410. Instruction Manual

GSM Modem 5. Installation and User Guide. English

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Installation and user s guide GSM8H - 3G. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup.

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual

LBVR1718. Description. Features channel paperless recorder

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

General information. Display. Supply voltage. Input current

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features:

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

BAS Web Server Datasheet

The Next Level of Energy Data Management Fast Data Acquisition via Parameterization No Programming

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

Digital Indicator Solutions

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

IntesisBox BACnet/IP Server DALI

General information. Display. Supply voltage. Input current. Encoder supply. Output current

BL compact fieldbus station for DeviceNet 4 Analog Outputs for Voltage BLCDN-4M12S-4AO-V

APP 700 Technical Specification

CONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual

Z-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Submittal Data Sheet WAGO Node for itm

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Communication module to connect M-bus devices to POL6xx.xxx controllers.

General information. Display. Supply voltage. Input current

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

ALPHACallisto Discrete Inputs

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

MID approval no. DE-08-MI004-PTB004 Date of release

General information. Display. Supply voltage

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

T2314, T2414. Instruction Manual

The industrial humidity transmitter

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

General information. Display. Supply voltage. Input current

Pen Drive USB Datalogger!

M-Bus Master MultiPort 250D

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

RNN5-STD NETWORK NODE FOR AMR SYTEMS

DMT345 and DMT346 Dewpoint Transmitters

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Comprehensive Modular Genset Controller

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

Transcription:

Data sheet Analog input module for MULTICAL 603 Two analog inputs, selectable as 0...20mA or 0...10V Individual scaling of measuring ranges Individual setup of measuring unit and decimal point Selectable update interval from 1 second to 1 hour Analog inputs are galvanically separated from the meter An external 24V AC/DC supply for the sensors is required

Contents Description 3 Technical data 5 Ordering 5 Configuration 6 Display readings 7 2 Kamstrup A/S 58101591_A1_GB_01.2018

Description HC-003-41 is an all-round analog input module for use in the MULTICAL 603 energy meter. The analog signals can come from sensors, which are often used in industry, or from sensors that are used in building automation, e.g. temperature, pressure, air velocity, air energy content and air humidity sensors. Typically, sensors emit 0...20mA or 0...10V signals. The module writes the values of the analog signals to the P1 and P2 registers of the meter. The analog signals can be read from the meter display, and at the same time, they are logged in the memory of the meter. The analog signals can also be remotely read via the many various communication modules that are available for MULTICAL 603. In addition to the scaling of the min. value, max value and decimal position of the signal inputs, various measuring units can also be allocated, e.g. bar, m/s, %RH, etc. The reading speed of the analog inputs can be selected between a number of intervals ranging from 1 second to 1 hour. A quick reading enables the analog signals to be used for control and regulation purposes. The analog inputs are galvanically separated from the meter. The module supplies the connected sensors via an isolated power supply, which also supplies the module itself. Applications The module can be used at places where there is a need for connecting 1 or 2 external sensors and where you want to read their measuring values in the meter display or remotely read the values via wired communication modules such as M-Bus, Modbus, BACnet and LON or wirelessly via wireless M-Bus and Kamstrup Low Power Radio and Kamstrup High Power RadioRouter. Installation The module is mounted in one of the module connectors of the meter. If there is a need for adjusting the module s configuration, this can be done by using METERTOOL HCW via the optical eye or by using a module programming cable. Note: There can only be 1 analog input module in the meter. Cable connections Cable size Max cable size 1.5 mm² Analog input connections Terminal 58: Sensor In 1 signal input Terminal 60: +supply for Sensor In 1 and Sensor In 2 Terminal 59: Sensor In 2 signal input Terminal 57: -supply for Sensor In 1 and Sensor In 2 Terminal 98: Supply 24-30 VAC/VDC for module and sensors Terminal 97: Supply Kamstrup A/S 58101591_A1_GB_01.2018 3

Description Examples of connection of sensors to input 1. Depending on sensor type, there may be a difference in how to connect them to the terminals of the module. + 60 Supply+ 58 0...10V Sensor with voltage output 57 Supply- + 60 58 Loop -supplied Sensor with current output 57 + 60 58 57 Sensor with active current output 4 Kamstrup A/S 58101591_A1_GB_01.2018

Technical data Physical Application For installation in MULTICAL 603 only Analog inputs Measuring ranges 0...20 ma or 0...10V Measuring accuracy Better than 0.1 % Galvanic separation According to PTB-A50.1 Supply of sensors Voltage 15 VDC ±5 % Current 50mA External supply Voltage 24 VDC/VAC ±30 % Recommended current 100mA Environment Operating temperature 5 C - 55 C Humidity 25 85 %RH non-condensing Programming Configuration Firmware update Via optical eye or the multipole connector on the module Via METERTOOL HCW Marking/approvals CE and EN 1434 together with the type approval of MULTICAL 603. Ordering Description Order no. Analog input module HC-003-41 Transformer 230/24 VAC 6699-403 USB configuration cable for H/C modules 6699-035 Optical read-out head with USB plug 6699-099 Optical read-out head with RS-232 D-SUB 9F 6699-102 METERTOOL HCW www.kamstrup.com Kamstrup A/S 58101591_A1_GB_01.2018 5

Configuration Configuration of the module can be done when ordering or via METERTOOL HCW. XX YY ZZZ Module type Analog input module 41 00 100 Input 1 and Input 2 signal type 0-20 ma 00 0-10 V 10 Parameters The following parameters can be adapted to input 1 and input 2: 0 % value The value of the signal when the current is 0 ma or the voltage is 0V 100 % value The value of the signal when the current is 20 ma or the voltage is 10V Decimal It is possible to select between 3, 2, 1 or none decimals Measuring unit The following units are selectable: Measuring Description unit Bar Pressure C Temperature %RH Relative humidity g/kg Absolute humidity O2 % Oxygen % m/s Velocity (air) kj/kg Enthalpy, energy content of air ph ph, acidity none Numeric value Reading speed It is possible to choose between the following intervals, which are common to both inputs: 1 second 2 minutes 2 seconds 5 minutes 5 seconds 10 minutes 10 seconds 15 minutes 15 seconds 30 minutes 30 seconds 60 minutes 60 seconds 6 Kamstrup A/S 58101591_A1_GB_01.2018

Display readings Current values The current values can be read from the energy meter s display by choosing the TECH loop. Display examples: Menu Menu index Information Display example 2-004-2 P1 Current value of input 1 Example: Pressure with 2 decimals 2-004-2 P1 Current value of input 1 Example: Temperature with 1 decimal 2-005-2 P2 Current value of input 2 Example: O2% with 2 decimals Note that unit is not displayed. 2-005-2 P2 Current value of input 2 Example: ph with 3 decimals Note that unit is not displayed. Kamstrup A/S 58101591_A1_GB_01.2018 7

Display readings Module information The module information can be read by choosing the TECH loop on the MULTICAL meter. Module placed in module slot 1: Choose menu 2-101 in the TECH loop Module placed in module slot 2: Choose menu 2-201 in the TECH loop The following module information is available: Menu Menu index Information Display example 2-x01 31 Module configuration 2-x01-1 32 Module firmware and revision 2-x01-2 33 Module serial number 2-x01-3 34 Module status * 0: Ok 1: No configuration 2: Internal error 4: No 24V supply Kamstrup A/S 58101591_A1_GB_01.2018 * There are 3 sources of errors that are weighted with each of their values. The sum of these 3 error values is shown in Module status. If Module status does not show 0 and 4, the module must be handed in for service. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 F: +45 89 93 10 01 info@kamstrup.com kamstrup.com 8 Kamstrup A/S 58101591_A1_GB_01.2018