1 CONVERTERS AND INTERFACES AC Current Z-LINE Z201 to DC ma/v isolator/converter Z-L LINE Electric parameters conv verters INPUT:N.1 channel current 0..5 Aac or Aac OUTPUT:N.1 channel current 0..20, ma or voltage 0..10, Vdc Galvanic 3-way: - 3,75 kvac between input and power supply/output - 1,5 kvac between power supply and output High accuracy: better than 0,3% Screw-fit terminals removable Din rail mounting POWER SUPPLY: Z201: Vdc, Vac Z201-H: Vac/Vdc
2 TECHNICAL DATA Z201 AC Current Converter ORDER CODES Code Model Z201 Z201-H Description Power Supply Vdc, Vac Power Supply Vac/Vdc GENERAL FEATURES 10 40Vdc, Vac, Vac/Vdc Channels N.1 Design Terminal housing for mounting on 35 mm DIN Admitted overlaod 12A continuative, 30A for 1 s Accuracy 0,3% DIP Switch Inputs signal setup Status indicators Power Enclosure "V0" self-extinguishing glass filled nylon case Galvanic Isolation Hot swapping Galvanic 3-way: 3,75 kvac between input and power supply/output and 1,5 kvac between power supply and output circuits Yes Dimensions 17,5 x 100 x 112 mm (w x h x d) Weight 140 g Operating temperature C Power consumption 2,5 W Connections Plug-in screw clamp terminal blocks, wires up to 2.5 mm 2 Sampling frequency Protections Installation class 5 samples / second Surges: 400W/ms. Loop supply short-circuit protected III, it can be applied on a three-phase network of up to 500V AC phase-phase, 300V AC phase-ground IP Protection IP 20 Standards EN EN EN EN60742 Humidity % a +40 C (not condensing) Approvals CE INPUT Alternate Current -0..5Aac end scale current input Aac end scale current input. OUTPUT Current: ma, ma Higher load resistance: 600 Ohm Voltage: 0..5 Vdc, 1..5 Vdc, Vdc and Vdc Lower load resistance: 2,5 KOhm DIMENSIONS AND INSTALLATION Application note Mounting 35 mm DIN Input 0..5 Thermocouple Aac Aac input Output Current active output Current passive output Voltage Z201_1010EN
3 AC / DC voltage to DC isolator / converter, loop powered loop power supply (5..28Vdc) Input Vac Vdc with different range (field selectable) Output 4 20mA Galvanic isolation 4,0 kvac Maximun Voltage 710 Vpk range independent Frequency DC / 20 Hz Hz Precision Class 0,3 Response time < 100 ms from 10 to 90 % Dimensions 17,5 x 100 x 112 mmm [w x h x d] Operating temperature C For further information, please visit
4 ORDER CODE Model Z202-LP AC / DC voltage to DC isolator / converter, loop powered TECHNICAL FEATURES GENERAL FEATURES 5 28Vdc Design Terminal housing for mounting on 35 mm DIN Channels N.1 Accuracy 0,3% DIP Switch Enclosure Inputs signal setup "V0" self-extinguishing glass filled nylon case Status indicators Galvanic Isolation Hot swapping Response time Overvoltage class Humidity Approvals Power 4000 Vac Yes < 100 ms - CAT III up to 300 Vac towards ground. - CAT II up to 600 Vac towards ground % a +40 C (non condensing) CE Dimensions 17,5 x 100 x 112 mm (w x h x d) Weight Operating temperature C Connections IP Protection IP 20 Standards 140 g Plug-in screw clamp terminal blocks, wires up to 2.5 mm 2 EN60688/ A1 + A2 EN / EN / EN /2001 INPUT - Alternate Voltage: Vac - Direct Voltage: Vdc Are available N.5 presetted scales: each range can be set and extended to the next one, and it's possible to calibrate the instrument on any intermediate point in the continuous range of V, without either over-setting the fixed ranges, or opening the instrument (multi-rev trimmer accessible from front panel). INSTALLATION, CONNECTION, DIMENSIONS OUTPUT Current: Passive, ma SETTINGS APPLICATION EXAMPLE INPUT / OUTPUT (POWER SUPPLY) Z202LP_1003EN
5 CONVERTERS AND INTERFACES Z-LINE AC Voltage to DC isolator / converter Electric parameters converters INPUT:N.1 channel voltage Vac in 41 presetted scales OUTPUT:N.1 channel current 0..20, ma or voltage 0..10, Vdc Galvanic 3-way: - 3,75 KVac between input and power supply/output - 1,5 KVac between power supply/output (Z202) - 4,0 KVac between power supply/output (Z202-H) High accuracy: 0,3% Screw-fit terminals removable Din rail mounting : Z202: Vdc, Vac Z202-H: Vac/Vdc
6 TECHNICAL DATA Z202 AC Voltage to DC isolator / converter ORDER CODE Cod. Z202 Cod. Z202-H Power Supply: 9..40Vdc / Vac Power Supply: Vac /Vdc GENERAL FEATURES Channels N.1 Accuracy Status indicators 9 40Vdc, Vac; Vac Design Terminal housing for mounting on 35 mm DIN ,3% DIP Switch -Inputs signal setup -Outputs signal setup Power Admitted overlaod Enclosure up to 10% of end scale "V0" self-extinguishing glass filled nylon case Galvanic Isolation Hot swapping Galvanic 3-way: 3,75 kvac between input and power supply/output and 1,5 kvac between power supply and output circuits Yes Dimensions 17,5 x 100 x 112 mm (w x h x d) Weight 140 g Operating temperature C Power consumption 2,5 W Connections Plug-in screw clamp terminal blocks, wires up to 2.5 mm 2 Sampling frequency 33 samples / second IP Protection IP 20 Protections Installation class Surges: 400W/ms. Loop supply short-circuit protected III, it can be applied on a three-phase network of up to 500V AC phase-phase, 300V AC phase-ground Standards EN EN EN EN60742 Humidity % a +40 C (not condensing) Approvals CE INPUT Alternate Voltage: Vac in 41 presetted scales Input impedance: 200 Ohm/V Frequency: 10 Hz..1KHz OUTPUT Current: ma, ma Higher load resistance: 600 Ohm Voltage: 0..5 Vdc, 1..5 Vdc, Vdc and Vdc Lower load resistance: 2,5 KOhm DIMENSIONS AND INSTALLATION Application note Mounting 35 mm DIN Input F. Thermocouple S. 10V..130V F. S. 140V..230V F. S. 240V..370V F. S. 380V..490V input Output Current act. output Current pass. out Voltage Z202 Z202-H Z202_0806EN
Intrinsically Safe Barriers
Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper
More informationADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.
EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier
More informationTime Counters mini "h", DC Version
Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable
More informationPGR-3200 MANUAL INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN
More informationFaults on the system Proximity switch connection technology:
Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches
More informationFeatures. LED Driver. RCOB Constant Current Active PFC Single Output. AC/DC Converter
Features LED Driver Low Cost 230VAC LED Supply 350mA to 1050mA Output, 25-44VDC Active Factor Correction >0.95 Designed to drive 15W-46W COB LEDs Terminal Block Input/Output with Cable Clamps Fully Protected
More informationInstallation Manual Series PQ-L. Electronic Module. Bulletin /UK
Bulletin 5715-571 /UK Installation Manual Electronic Module Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+) 2131-513-0 Fax: (+) 2131-513-230 www.parker.com Copyright Ó 2000, Note This document and other
More informationI-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS
I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog
More informationSLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER
SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More information02/11/2015
DIN Rail Mount 22.5 mm ETM2 Part number 84874023 Version ETM : Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2 / ETM22 : Fault latching
More informationVoltage Current Front-mounting bracket
Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction
More informationHIT/HIX HART Isolator
/ Isolator December 2017 Description Moore Industries Isolators provide highly economical solutions to common and costly problems that plague many of today s smart process loops. Protect and enhance your
More informationTM3TM3 module TM3-2 temperature inputs and 1 analog output
Characteristics module TM3-2 temperature inputs and 1 analog output Main Range of product Product or component type Range compatibility Analogue input number 2 Analogue input type Analogue output number
More informationArticle no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC
Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category
More information20 General technical data XI/ON
20 General technical data XI/ON General technical information General technical data XI/ON Potential isolation Ambient temperature Operating temperature Storage temperature Relative humidity Noxious gas
More informationXPSMCMDO Digital output pairs expansion modules with screw term
Characteristics 2 Digital output pairs expansion modules with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs
More informationRMCN22BD Analog Converter ma - for Zelio Analog
Characteristics Analog Converter - 4..20 ma - for Zelio Analog Main Commercial Status Range of product Product or component type Analogue input type Analogue output type Commercialised Zelio Analog Voltage/Current
More informationLAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
More informationNeon pr. ph/ ORP measurement. Applications. Description
Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment
More informationABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011
Technical Data 2CDC504084D0201 ABB i-bus KNX Product description The device is used to record analogue data. Four conventional sensors can be connected to the device. The connection to the bus is established
More informationMCX08M2 Programmable controller
Data sheet MCX08M2 Programmable controller MCX08M2 is an electronic controller that holds all the typical functionalities of MCX controllers in the compact size of 8 DIN modules: programmability connection
More informationTM3TI8T module TM3-8 inputs temperature
Characteristics module TM3-8 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 8 Analogue input type Complementary Analogue input resolution Input
More informationMODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)
Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast
More informationTable of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7
User's Manual: Series 330I Model 330I DC-Powered Three-Way Isolator Table of Contents Page Introduction... 2 Description....2 Specifications....3 Installation.. 5 Calibration.. 6 General Maintenance...7
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power
More informationSwitch Mode Power Supply S8VT 120/240/480/960 W Models
Switch Mode Power Supply 120/240/480/960 W Models Natural Cooling Three-phase Power Supply Range from 5A up to 40A with Output Voltage of 24VDC 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output
More informationABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011
Technical Data 2CDC505168D0201 ABB i-bus KNX Product description The Analogue Actuator converts telegrams received via KNX into analog output signals. The device has four outputs. The analog outputs can
More informationXPSMCMDI Input expansion module with screw term
Characteristics 16 Input expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs Number of outputs
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationTM3TI4 module TM3-4 inputs temperature
Characteristics module TM3-4 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible
More informationOrdering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend
Three-phase Input Switch Mode Power Supply S8VT DIN-rail mounting, Power Supply with a range of 5 A to 40 A output current 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output Higher stability, lower
More informationXPSMCMMX inputs 2 output pairs expansion module with screw term
Characteristics 8 inputs 2 output pairs expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs
More informationOTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m
Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete
More informationTC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER
TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER TECHNICAL DATA MECHANICAL DATA Housing Self-extinguishing plastic, UL 94 V0 Dimensions 33x75 mm depth 64 mm Weight 175 g approx. Connections 2,5 mm
More informationPU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance
PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance red display of -9999 99999 digits installation depth: 120 mm without
More informationVariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.
Universal Isolation Amplifiers The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply. The Housing At a width of just 12.5 mm, the modular housing with pluggable
More information96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply
gal/h Digital panel meter 4½digit DV4 Without setpoints Sensor supply status 22/05/06 panelmeteranalog_gb.doc page 9 Digital panel meter Direct voltage Direct current gal/h Direct voltage, direct current
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationSee instructions to download and install the latest version of LinkBoxLON and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationDI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs
Multi-Channel Analog Output Modules DC Current or DC Voltage Outputs Discrete Outputs DI-917MB/DI-918MB Models DI-917MB: 4 current output channels DI-918MB: 4 voltage output channels Analog Output DI-917MB:
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationiologik 4000 Series (M) Modules
iologik 4000 Series (M) s Remote I/O modules Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin
More informationECT Signal Isolator/Converter
August 1997 Now with Dual I/O Channels Data Sheet 2.02 Description The family of signal isolators and converters delivers economical solutions for a wide variety of signal interface applications. Isolator
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationI/O Expansion Module Installation & Reference
Overview The In-Sight vision sensor supports up to ten discrete inputs and ten discrete outputs. Two inputs and two outputs are built-in to the In-Sight processor. The remaining eight inputs and outputs
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationPGR-2601 MANUAL DC GROUND-FAULT RELAY
POWR-GARD Ungrounded DC System PGR-2601 SERIES DC Ground-Fault Relay PGR-2601 MANUAL DC GROUND-FAULT RELAY AUGUST 31, 2009 REVISION 1 POWR-GARD DC GROUND-FAULT RELAY PWR TRIP 5 4 3 2 6 - BUS 8 10 15 20
More informationTM3DI16 module TM3-16 inputs
Characteristics module TM3-16 inputs Main Range of product Product or component type Range compatibility Jun 30, 2018 Modicon TM3 Discrete input module Modicon M241 Modicon M251 Modicon M221 Discrete input
More informationABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS
Characteristics battery control module - 24..28.8 V DC - 24 V - 40 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Complementary
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationControl elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.
On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationData sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!
-CMT-10-AO-RC-S [!-] General ordering data Type -CMT-10-AO-RC-S Order No. 1510470000 Version Current-measuring transducer GTIN (EAN) 4050118319583 Qty. 1 pc(s). -CMT-10-AO-RC-S Technical data Dimensions
More information02/11/2015
DIN Rail Mount 22.5 mm TU2R1 Part number 88865305 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /
More informationSignal Doublers. VariTrans A 20300
ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission
More informationDKG-210 UNIVERSAL INTERNET GATEWAY UNIT
DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW
More informationTM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO
Characteristics compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO Main Range of product Product or component type Complementary Enclosure material Colour Input/Output number
More informationVEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA
Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationVEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA
4 time ranges 4 transition times Supply voltage 12-240V AC/DC 2 normally open contacts Width 22,5 mm Control elements Fine adjustment star contactor Setting of time range star contactor Transit time Status
More informationNEUROLOGIC RESEARCH CORPORATION MODEL 2500
NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication
More informationSee instructions to download and install the latest version of LinkBoxEIB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationEnergy meters Single phase electrical energy meters WM1-6 / WM1M6
Energy meters Single phase electrical energy meters WM1-6 / WM1M6 o Single phase direct connected DIN-rail mounting meter o Class 1 for active energy according to EN 62053-21 and B according to EN 50470-3
More informationAS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input
Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20
More informationSR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display
Characteristics compact smart relay Zelio Logic - 20 I O - 100..240 V AC - clock - display Main Range of product Product or component type Complementary Local display Number or control scheme lines Cycle
More informationAC/DC Converter SLD05-20Bxx Series
www.schmid-m.com DC/DC Converters AC/DC Converter 5W, AC/DC converter FEATURES Universal input voltage range: 85~264VAC/100~370VDC AC and DC dual-use(input from the same terminal) High efficiency, high
More informationVEO. V2UF230V10 Art.Nr.: TECHNICAL DATA
Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after
More informationSafety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.
Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers
More informationCONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual
50 and 50 Digital I/O Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676
More informationOTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m
Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage
More informationMini Digital Multimeter
User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers
More informationEnergy Management Energy Transducer Type ET112
Energy Management Energy Transducer Type Single phase energy transducer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement
More informationTM3AI4 module TM3-4 analog inputs
Characteristics module TM3-4 analog inputs Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible
More informationXPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term
Characteristics Modbus TCPIP diagnostic expansion module with screw term Main Range of product Product or component type Device short name [Us] rated supply voltage Complementary Power dissipation in W
More informationOTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m
Product datasheet Characteristics OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Complementary Concept Port Ethernet Bus length Main Number of devices per segment 0...256 Communication
More information08/07/2015
DIN Rail Mount 22.5 mm TUR1 Part number 88865105 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /
More information895/896M Frequency Output Math Modules
895/896M Frequency Output Math Modules Application Example Both models are designed for integrator/totalizer applications. The 896M is ideal for demand metering applications. With one high speed pulse
More information170 ADI VDC - 16 Pt. Discrete Input Module Base
24 VDC - 16 Pt. Discrete Input Module Base 11 At a Glance Purpose This chapter describes the 170 ADI 340 00 TSX Momentum I/O base. In This Chapter This chapter contains the following sections: For This
More informationOTB1C0DM9LP I/O distributed module OTB - CANopen bus m
Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Main Range of product Product or component type Integrated connection type Bus type Jan 28, 2018 Modicon OTB I/O distributed module
More informationProduct data sheet: OTi DALI 25/ /700 LT2 G2
www.osram.com Product data sheet: OTi DALI 25/220-240/700 LT2 G2 SELV Constant current LED driver Wide operating area up to 700mA - dimmable The reliable choice for the energy saving lighting: DALI dimmable,
More informationAS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input
ext. in ext. in AS-i Safety Relay Output Module with Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V Additionally 1 EDM input, 1 x
More informationYour process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this
Overview Signal converters Your process requires the utmost attention Our new signal conditioners support you in achieving this Many process parameters in your system are handled by your control system,
More informationStandard-Signal Isolation Amplifiers. VariTrans A 21000
Standard-Signal Isolation Amplifiers The first standard-signal isolation amplifier with protective separation and broad-range power supply in the 6-mm class. The Task Isolation and conversion of 0... 20
More informationIndustrial Power Supplies
, NEW Features For Industrial, Office and Residential Application Ultracompact Plastic Housing Connection by Cage Clamps Terminals or plugable Screw Terminals Reliable snap-on Mounting on DIN-Rails Adaptor
More informationTM3TI4 module TM3-4 inputs temperature
Characteristics module TM3-4 inputs temperature Complementary Analogue input resolution Permissible continuous overload Input impedance LSB value Conversion time Sampling duration Main Range of product
More informationPGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY REVISION 3-B-041318 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More information9000C INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4
Doc.Ref.No.:m92E/om/101 INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING... 3 CONNECTION 3 INSTALLATION.. 4 ORDERING CODE 4 TROUBLE SHOOTING 4 ISOLATED CONVERTER 9000C SERIES 9000C Series
More informationLED driver 36W 0.3-1A 48V 230V
Electrical input data minal input voltage 220...240 Vac minal input frequency 50...60 Hz minal input current 0.2 A minal input power 42 W Power factor 0.9 Total harmonic distortion 30 Efficiency 85, maximum
More informationSeries AME25-JZ 25 Watt AC-DC / DC-DC Converter
FEATURES: Click on Series name for product info on aimtec.com Series AME-JZ I/O Isolation 000VAC Low Ripple and Noise Operating Temp: -0 C to +70 C Over Voltage Protection Over current Protection Up to
More informationSafety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationIsolated Process Current Input with Loop Power 7B35
Isolated Process Current Input with Loop Power 7B35 FEATURES Single-channel signal conditioning current input module that interfaces with two-wire transmitters. Module provides a precision output of either
More informationOutput Voltage* (nom.)(adjustable)
Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series
More informationSeries AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter
Click on Series name for product info on aimtec.com Models Single output Model Input Voltage (VAC/Hz) FEATURES: Input Voltage (VDC) Max Output wattage (W) Output Voltage (V) Output Current max (A) Maximum
More informationIsolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Process Current Input 7B32 FEATURES Interfaces, amplifies and filters a process-current input. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.
More informationMODEL 9250 Preliminary data sheet
Delivery: ex stock Warranty: 24 months Universal Instrumentation Amplifier for strain gage, potentiometric, DC/DC and incremental sensors MODEL 9250 Preliminary data sheet NEW burster TEDS Highlights Ultra-fast
More informationSTBEHC3020KC counter kit STB - 1 CH Hz - 2 I
Characteristics counter kit STB - 1 CH - 0..40000 Hz - 2 I Main Range of product Product or component type Number of channels 1 Complementary Kit composition Counting input number 2 Counting frequency
More informationElectronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features
Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter
More informationArticle No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.
Product Name Type of power supply Electrical data Input Waveform of the input Supply Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.6A DC; NEC Class 2 single-phase AC Power Supply SCALANCE
More information