QUICK START GUIDE M2000 SERIES rue Charles, Suite 100, Mirabel, QC, J7J 1X9

Similar documents
HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

HARDWARE GUIDE. Boiler Controller M2000 Series. Specifications and Operational Guide

HARDWARE GUIDE. Hydronics Controller M2000 Series. Specifications and Operational Guide

HARDWARE GUIDE. VAV Zone Controller C1000 Series. Specifications and Operational Guide

M1000 INTELLIGENT ZONE CONTROL SYSTEM

FOCUS GUIDE IOS APP. Configuration Guide for ProLon Focus Software

QUICK START GUIDE BLUETOOTH, NETWORK CONTROLLER AND DIGITAL THERMOSTAT

LN Series Remote Input/Output (I/O) Modules

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

FX14 Field Controller

THERMOSTATS & CONTROLLERS

Fast Route to Reliable Energy Savings ZIP Economizer

FX-DIS1710 Local Controller Display Installation Instructions Part No , Rev. B Issued April 2016

TEC Zoning Control System for Stand-Alone and BACnet MS/TP Networked Applications

Custom Controller Installation Instructions

Network Control Engine Catalog Page

rcc.1081 Installation Instructions

LX Series Free Programmable LX-PRG6x0-11 Controllers and LX Series Input/Output (I/O) Extension Modules

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

VZ7000 Series. BACnet Commercial Zoning System

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Rack Input Module Installation Instructions

FOCUS USER GUIDE. Configuration Guide for ProLon Focus Software

Tracer Controllers. Tracer MP503 Input/Output Module BAS-PRC009-EN. September 2001

ECON-ZIP-BASE. ZIP Economizer Base Module

TAC Xenta 121-HP Programmable Heat Pump Application

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

FX40 Supervisory Controller

Tracer Controllers. Tracer MP503 Input/Output Module BAS-PRC009-EN. January 2005

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

FOCUS GUIDE VAV ZONE CONTROLLER. Configuration Guide for ProLon Focus Software

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

SEZ7000 Series. Wireless Commercial Zoning System

SE7600E Series Application Guide

Siemens BACnet Programmable TEC Unit Conditioner Controller

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

LN Series Free Programmable LN-PRG6x0-12 Controllers and LN Series Input/Output (I/O) Extension Modules

FOCUS GUIDE NETWORK CONTROLLER. Configuration Guide for ProLon Focus Software

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

clarity 3 Programmable Controller

Installation Guide AVA-2902E/I. PCI-to-Fast SCSI Host Adapters. PCI SCSI Host Adapter with Internal or External Connector

TC-9102 Terminal Controller

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

LX Series Remote Input/Output (I/O) Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

FX Input/Output (I/O) Modules XM07 and XM14

Smart Equipment Controls (SEC)

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

TAC Xenta 121-FC Programmable Fan Coil Application

Quick Start Guide. Sabre 1400 Hand-held Scanner

Onboard Inputs and Outputs. Remote User Interface. Integral LCD User Interface

ETM-2020/ETM-2024 Installation Instructions

Siemens BACnet Programmable TEC Unit Vent Controller

Unpacking. Installation

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Application Engineering

Andover ContinuumTM Infinet II

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

VT8300 Room Controller

HARDWARE GUIDE PL-485-BT. Specifications and Operational Guide

Case Management System Installation Instructions

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

SE8300 Room Controller

System 450 Series Modular Controls

Siemens BACnet Programmable TEC Constant Volume

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

3M RFID Tracking Pad Model 770

NSD/M1 Installation Instructions

Introduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers

Infosystem Remote Touchscreen Installation Instructions

WILDCAT REALIZM 800 WILDCAT REALIZM 500 WILDCAT REALIZM 200 WILDCAT REALIZM 100

FX-BTCVT Bluetooth Commissioning Converter Installation Instructions

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

Control different load types with one device

P216. Condenser fan speed controller. Product bulletin. Features

68-pin Internal Ultra160-LVD Connector. Adaptec SCSI Card 29160N

DUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS

Leadtek S202 Wi-Fi Smart Power Plug. User Manual. Jun 29, 2016

Medium User Interface (MUI) Version 3

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

System 450 Series Modular Controls

Quick Start Guide DDC (2014/02) Subject to change without prior notice Quick Start Guide

Field selectable application type and room module series, via dip-switches on controller

Dual Duct Controller - One Air Velocity

Network Control Engine

MIL-S24002TGxx. 24-port 10/100/1000 TX 2 Combo SFP Slots Unmanaged Switch. User Guide

VT8600 Series Installation Guide. Rooftop Unit, Heat Pump and Indoor Air Quality Controller

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Andover ContinuumTM. b3850 Series Terminal Controllers

Room Controllers. SC3000 Relay Pack

BACnet Terminal Box (VAV) Controller

Support for Non-Ultra2 SCSI Devices

Tstat8. Bacnet Thermostat

MONOPRICE. Blackbird 4x4 HDMI Matrix/Extender with 4 Receivers. User's Manual P/N 21905

Transcription:

QUICK START GUIDE M2000 SERIES www.proloncontrols.com info@proloncontrols.com 17 510 rue Charles, Suite 100, Mirabel, QC, J7J 1X9 REV.2.0 PL-QCK-M2000-EN

Copyright 2018 Prolon. All rights reserved. No part of this document may be photocopied or reproduced by any means, or translated to another language without prior written consent of Prolon. All specifications are nominal and may change as design improvements are introduced. Prolon shall not be liable for damages resulting from misapplication or misuse of its products. All trademarks are the property of their respective owners.

Table of Contents Boiler Controller (PL-M2000-BLR)...4 FlexIO Controller (PL-M2000-FLX)...6 Heatpump Controller (PL-M2000-HP & PL-M2000-HPS)...8 Hydronic Controller (PL-M2000-HYD)... 10 Make Up Air Controller (PL-M2000-MUA)... 12 Rooftop Controller (PL-M2000-RTU & PL-M2000-RTUS)... 14 Compliance... 16 Technical Specifications... 16 REV.2.0 / PL-QCK-M2000-EN 3

Boiler Controller (PL-M2000-BLR ) INT Port: Incoming RS485 network communication (Modbus) AO 3 - Valve (0-10 / 2-10 / 0-5 VDC) or backup modulating boiler AO 2 - Modulating boiler (0-10 / 2-10 / 0-5 VDC) AO 1 - Pump 2 (ON/OFF) (0/10VDC) DO 5 - Pump 1 DO 4 - Boiler stage 4 DO 3 - Boiler stage 3 DO 2 - Boiler stage 2 DO 1 - Boiler stage 1 Bottom row: common for all outputs 32-122 F (0-50 C) Non-condensing 4 REV.2.0 / PL-QCK-M2000-EN

Bottom row: common for all inputs Disable Boiler Call (dry contact) Use max heat setpoint (dry contact) Proof of pump 2 (AO1) (dry contact) Proof of pump 1 (DO5) (dry contact) Return water temp sensor (10K thermistor) Supply water temp sensor (10K thermistor) Outside air temperature sensor (10K thermistor) 24 VAC NET Port: Incoming RS485 network communication (modbus) Controller s power source (24VAC - Class 2) culus Listed; UL 916 Energy Management Equipment, File E364757, Vol.1 REV.2.0 / PL-QCK-M2000-EN 5

FlexIO Controller (PL-M2000-FLX) INT Port: RS485 network communication (Modbus) Analog output 3 Analog output 2 Analog output 1 Digital output 5 Digital output 4 Digital output 3 Digital output 2 Digital output 1 Bottom row: common for all outputs 32-122 F (0-50 C) Non-condensing 6 REV.2.0 / PL-QCK-M2000-EN

Bottom row: common for all inputs Analog input 9 Analog input 8 Analog input 7 Analog input 6 Analog input 5 Analog input 4 Analog input 3 Analog input 2 Analog input 1 24 VAC NET Port: RS485 network communication (Modbus) Controller s power source (24VAC - Class 2) culus Listed; UL 916 Energy Management Equipment, File E364757, Vol.1 REV.2.0 / PL-QCK-M2000-EN 7

Heatpump Controller (PL-M2000-HP & PL-M2000-HPS) HP Incoming communication from remote computer - OR - Network Controller (dual RJ45 and terminal blocks) HPS INT Port: Prolon digital temperature sensor - OR - Incoming RS485 network communication (Modbus) AO3 - Bypass / VSD AO2 - Economizer AO1 - Preheating / Mod. Heat DO5 - Aux Heat DO4 - Rev Valve DO3 - Compressor 2 (Y2) DO2 - Compressor 1 (Y1) DO1 - Fan (G) Bottom row: common for all outputs 32-122 F (0-50 C) Non-condensing 8 REV.2.0 / PL-QCK-M2000-EN

Bottom Row: common for all inputs Static pressure (0-5 / 1-5V) (1 / 1.5 / 2 / 2.5 in) Ext dry contact for alarm / CO2 sensor (4-20 ma) External dry contact for proof of fan Zone temperature setpoint (0-10K potentiometer) Zone temperature sensor (10K thermistor) Dry contact for clogged filter / Dry contact for schedule override / Supply water temp (10k therm) Supply air temperature sensor (10K thermistor) Return air temperature sensor (10K thermistor) Outside air temperature sensor (10K thermistor) Supply water temp sensor (10K thermistor) 24 VAC HP Outgoing network communication (to zones) HPS Net Port: Prolon digital temperature sensor - OR - Incoming RS485 network communication (Modbus) Controller s power source Unit s R&C terminals (24VAC) culus Listed; UL 916 Energy Management Equipment, File E364757, Vol.1 REV.2.0 / PL-QCK-M2000-EN 9

Hydronic Controller (PL-M2000-HYD) Incoming communication from remote computer -OR- Network Controller (dual RJ45 and terminal Blocks) Output function varies depending on chosen setup Analog output 3 (0-10VDC) Analog output 2 (0-10VDC) Analog output 1 (0-10VDC) Digital output 5 (24 VAC) Digital output 4 (24 VAC) Digital output 3 (24 VAC) Digital output 2 (24 VAC) Digital output 1 (24 VAC) Bottom row: common for all outputs 32-122 F (0-50 C) Non-condensing 10 REV.2.0 / PL-QCK-M2000-EN

Bottom row: common for all inputs Analog input 9 (thermistor / 4-20mA / 0-5VDC) Analog input 8 (thermistor / 4-20mA / 0-5VDC) Analog input 7 (thermistor / 4-20mA / 0-5VDC) Analog input 6 (thermistor / 4-20mA / 0-5VDC) Analog input 5 (thermistor / 4-20mA / 0-5VDC) Analog input 4 (thermistor / 4-20mA / 0-5VDC) Analog input 3 (thermistor / 4-20mA / 0-5VDC) Analog input 2 (thermistor / 4-20mA / 0-5VDC) Analog input 1 (thermistor / 4-20mA / 0-5VDC) Input function varies dependint on chosen setup 24 VAC Outgoing network communication (to zones) Controller s power source Unit s R&C terminals (24VAC) culus Listed; UL 916 Energy Management Equipment, File E364757, Vol.1 REV.2.0 / PL-QCK-M2000-EN 11

Make Up Air Controller (PL-M2000-MUA) INT Port: Incoming RS485 network communication (Modbus) AO3 - Variable frequency drive AO2 - Cooling AO1 - Modulating heat DO5 - Alarm DO4 - Preheat permission DO3 - Fan DO2 - Outside air damper DO1 - Occupancy (exhaust) Bottom row: common for all outputs 32-122 F (0-50 C) Non-condensing 12 REV.2.0 / PL-QCK-M2000-EN

Bottom row: common for all inputs CO2 (4-20mA) / Building pressure (0-5VDC) Zone temperature (10K thermistor) Outside temperature (10K thermistor) Supply temperature (10K thermistor) Manual reset Proof of san Proof outside air damper open Proof exhaust 2 / Manual override Proof exhaust 1 24 VAC NET Port: Incoming RS485 network communication (Modbus) Controller s power source (24VAC - Class 2) culus Listed; UL 916 Energy Management Equipment, File E364757, Vol.1 REV.2.0 / PL-QCK-M2000-EN 13

Rooftop Controller (PL-M2000-RTU & PL-M2000-RTUS) RTU Incoming communication from remote computer - OR - Network Controller (dual RJ45 and terminal blocks) RTUS INT Port: Prolon digital temperature sensor - OR - Incoming RS485 network communication (Modbus) AO3 - Bypass / VSD AO2 - Economizer AO1 - Preheating / Mod. heat DO5 - Heat (W2) / Exhaust fan / Baseboard DO4 - Heat (W1) / Preheat perm. DO3 - Cooling (Y2) DO2 - Cooling (Y1) DO1 - Fan (G) Bottom row: common for all outputs 32-122 F (0-50 C) Non-condensing 14 REV.2.0 / PL-QCK-M2000-EN

Bottom row: common for all inputs Static pressure (0-5 / 1-5V) (1 / 1.5 / 2 / 2.5 in) CO2 sensor (4-20 ma) External dry contact for proof of fan Zone temperature setpoint (0-10K potentiometer) Zone temperature sensor (10K thermistor) Mixed air temp (10K therm) / Dry contact for clogged filter / Dry contact for schedule override / Auxiliary temp input (10K thermistor) Supply air temperature sensor (10K thermistor) Return air temperature sensor (10K thermistor) Outside air temperature sensor (10K thermistor) 24 VAC RTU Outgoing network communication (to zones) RTUS Net Port: Prolon digital temperature sensor - OR - Incoming RS485 network communication (Modbus) Controller s power source unit s R&C terminals (24VAC) culus Listed; UL 916 Energy Management Equipment, File E364757, Vol.1 REV.2.0 / PL-QCK-M2000-EN 15

Compliance culus Listed; UL 916 Energy Management Equipment, File E364757, Vol.1 CAN/CSA-C22.2 No. 2015-12, Signal Equipment FCC Compliant to CFR47, Part 15, Subpart B, Class B Industry Canada (IC) Compliant to ICES-003, Issue 5: CAN ICES-3 (B) / NMB-3(B) RoHS Directive (2002/95/EC) FCC User Information This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Industry Canada This Class (B) digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment regulations. Cet appareil numérique de la Classe (B) respecte toutes les exigences du Réglement sur le matériel brouilleur du Canada. Technical Specifications Supply: 24 VAC ±10%, 50/60 Hz, Class 2 Power: 5 VA (consumption), 40 VA (Input) 16 REV.2.0 / PL-QCK-M2000-EN