Room Temperature Controller

Similar documents
Room Temperature Controllers

Room Temperature Controller

Semi flush-mounted room temperature controllers with LCD

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Semi flush-mounted room temperature controllers with LCD

Semi Flush-mount Room Temperature Controllers with LCD

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

Room unit with PPS2 interface

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

Master room unit for RRV controllers

Room thermostat with KNX communications For VAV heating and cooling systems

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

7-day room temperature controller

Heating Circuit Controller

Temperature controller Ducted systems

Non-communicating room controllers

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

7-day room temperature controller

Heating Circuit Controller

Weekday / weekend room temperature controller

Temperature Controller (Heat Pumps)

Temperature Controller

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room unit with PPS2 interface

Room thermostats with KNX communications

Room unit with PPS2 interface

Universal Controller

Immersion Temperature Sensors

RDF Series Room Temperature Controllers

Weekday / weekend room temperature controller

Room thermostats with KNX communications

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Room unit with PPS2 interface

Non-communicating room controllers

Temperature controller for multi-zone ducted systems

Temperature controller Multi-zone ducted systems

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Electrical Actuators

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

UCU Room Display. Operation Modes. Features. Applications DATASHEET

Heating Controllers. Siemens Building Technologies HVAC Products. Synco 700

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Electrical Actuators

24-hour room temperature controller

Electrical Actuators

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Wall-mounted room thermostats with LCD

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

ERF910. RF Repeater. Synco living

Product and Application Description

Compact Universal Controllers

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

TC-8900 Controller Units with PM-8900 Power Modules

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

QMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74 QMX3.P37. Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode

Pre-programmed room controller with display and communication

M-Bus Central Unit. Use

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

VAV modular controller

Power supply module, bus connection module

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

VAV compact controller GDB181.1E/3 GLB181.1E/3

Communicative controller for VAV systems

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

Room controller STRA-17

Extension module for lighting control

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Switching and Monitoring Device

Zelio Control-modular measurement and control relays 1

Electromotoric actuators

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

Product and functional description

VAV compact controller KNX / PL-Link

HERZ Actuator 7708, 7990

Compact universal controllers

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Status display unit with P-bus connection

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

Electromotive actuators for combi valves

7-day room temperature controller

Product and functional description

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Room thermostats with KNX communications

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Digital input modules

Transcription:

3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes: normal, energy saving and frost protection or OFF Operating mode changeover input for remote control Selectable control parameters Operating voltage AC 230 V Use Typical use: Control of the room temperature in individual rooms that are heated or cooled with four-pipe fan coil units For opening or closing a valve for switching a three-speed fan Functions The controller acquires the room temperature with its integrated sensor or external room temperature sensor (QAA32) or external return air temperature sensor (QAH111) - if used - and maintains the setpoint by delivering control commands to the 2-pointvalve The switching differential is adjustable It can be 1 or 4 K in heating mode and 05 or 2 K in cooling mode CE1N3023en 12062003 Siemens Building Technologies HVAC Products

Fan operation The fan is switched to the selected speed via control output Q1, Q2 or Q3 When the function Temperature-dependent fan control is activated (can be selected with DIP switch no1), the fan is switched on / off depending on the temperature, that is, together with the valve It is switched off by leaving the heating or cooling sequence, provided the function Temperaturedependent fan control is activated, or manually changing to standby, provided plant conditions do not call for frost protection mode, or activating an external operating mode changeover switch, provided plant conditions do not call for energy saving or frost protection mode, or turning the controller s power supply off Heating mode ON OFF The heating valve receives the OPEN command via control output Y11 when 1 the measured room temperature lies by half the switching differential below the setpoint, and 2 the heating valve has been fully closed for more than one minute The heating valve receives the CLOSE command via control output Y11 when 1 the measured room temperature lies by half the switching differential above the setpoint, and 2 the heating valve has been fully open for more than one minute Cooling mode ON OFF The cooling valve receives the OPEN command via control output Y21 when 1 the measured room temperature lies by half the switching differential plus the dead zone above the setpoint (x w + x dz + ½ SDC) and 2 the cooling valve has been closed for more than one minute The cooling valve receives the CLOSE command via control output Y21 when 1 the measured room temperature lies by half the switching differential plus the dead zone below the setpoint (x > w + x dz - ½ SDC) and 2 the cooling valve has been open for more than one minute Heating / cooling mode Y11 X dz 3023D01 T SDH Room temperature Switching differential "Heating" 1 SDC Switching differential "Cooling" 0 1 Y21 ½ SDH w ½ SDH ½ SDC ½ SDC T [ C] X dz w Y11 Y21 Dead zone Room temperature setpoint Manipulated variable "Heating valve" Manipulated variable "Cooling valve" Return air temperature The RCC30 provides control either depending on the measured room temperature or depending on the fan coil unit s return air temperature Changeover is automatic if a QAH111 cable temperature sensor is connected to the device 2/8

Energy saver The room temperature setpoint can be limited in increments of 1 K by making use of the minimum and maximum limitation facility Arbitrary setpoint readjustments can thus be prevented Operating modes Normal operation Frost protection mode Energy saving mode Operating mode changeover switch The following operating modes are available: Heating or cooling mode with automatic changeover and with manually selected fan speed III, II or I In normal operation, the controller maintains the adjusted setpoint in heating mode and, in cooling mode, a temperature level represented by the setpoint plus the dead zone The frost protection function is activated only when DIP switch no4 is set to OFF Frost protection mode can be activated either by manually switching to standby by activating the external operating mode changeover switch, provided DIP switch no2 is set to OFF If the room temperature falls below 8 C, the controller will automatically switch to frost protection mode In that case, the heating valve opens and the fan operates at the selected speed If the operating mode selector is in position standby, the fan will operate at speed I The room temperature is maintained at a setpoint of 8 C and the setpoint adjusted by the user will be ignored If frost protection mode is locked (DIP switch no4 in position ON), standby is locked also, which means that the controller will not switch to standby but to OFF In energy saving mode, the setpoint of heating is 16 C and the setpoint of cooling 28 C, independent of the position of the setpoint knob This operating mode will be activated when input D1 for operating mode changeover is active and DIP switch no2 is set to ON A changeover switch can be connected to status input D1-GND When the switch closes its contact (caused by an open window, for instance), the operating mode will change from normal operation to energy saving mode (provided DIP switch no2 is set to ON), or from normal operation to standby (provided DIP switch no2 is set to OFF) If the room temperature falls below 8 C and if DIP switch no4 is set to OFF, frost protection mode will become active The operating action of the switch (NC or NO) can be selected Ordering When ordering, please give name and type reference The QAH111 temperature sensor (used as a return air temperature sensor) and zone valves are to be ordered as separate items Equipment combinations Type of unit Type reference Data sheet Temperature sensor QAH111 1840 Room sensor QAA32 1747 Motoric on/off actuator SFA21 4863 Thermal actuator (for radiator valve) STA21 4893 Thermal actuator (for small valve 2,5 mm) STP21 4878 3/8

Mechanical design The unit consists of two parts: A plastic housing which accommodates the electronics, the operating elements and the built-in room temperature sensor A mounting base The housing engages in the mounting base and snaps on The base carries the screw terminals The DIP switches are located at the rear of the housing Setting and operating elements 3021Z01 2 3 5 6 4 1 Legend 6 Set of DIP switches 1 Operating mode selector (standby, heating or cooling mode with manual selection of fan speed) 2 LEDs for indicating heating mode, cooling mode and fan operation 3 Setting facility for minimum setpoint limitation (in increments of 1 K) 4 Setting facility for maximum setpoint limitation (in increments of 1 K) 5 Room temperature setpoint knob DIP switch no Meaning Position ON Position OFF 1 Fan control Fan control is temperaturedependent in all operating modes Fan control in normal operation is temperature- independent 1) 2 Operating mode changeover via external switch Changeover between normal operation and energy saving mode Changeover between normal operation and standby 1) 3 Operating action of switch for external operating mode changeover Changeover activated when contact of switch is closed (NO) 1) 4 Standby Frost protection function not enabled Changeover activated when contact of switch is open (NC) Frost protection function enabled 1) 5 Switching differential 1 K in heating mode 1) 05 K in cooling mode 1) 4 K in heating mode 2 K in cooling mode 6 Dead zone in normal operation 2 K 1) 5 K 1) Factory setting 4/8

Accessories Description Adapter plate 120 x 120 mm for 4 x 4 conduit boxes Adapter plate 96 x 120 mm for 2 x 4 conduit boxes Adapter plate for surface wiring 112x130 mm Type reference ARG70 ARG701 ARG702 Engineering notes Mounting, installation and commissioning notes Mounting location: on the wall or inside the fan coil unit Not in niches or bookshelves, not behind curtains, above or near heat sources and not exposed to direct solar radiation Mounting height is about 15 m above the floor The connecting wires can be run to the controller from a recessed conduit box Check the settings of the DIP switches no1 through no6 and change them if required If setpoint limitation is required, use the minimum and maximum limitation facility (energy saver) After applying power, the controller makes a reset during which the fan LED flashes, indicating that the reset has been correctly made This takes about 3 seconds Then, the controller will be ready to operate and the LED stops flashing, The cables used must satisfy the insulation requirements with regard to mains potential Sensor input B1-M carries mains potential If the sensor s cables must be extended, the cables used must be suited for mains voltage The controller is supplied with Mounting Instructions 5/8

Technical data Power supply Operational data Environmental conditions Norms and standards Operating voltage AC 230 V +10/-15 % Frequency 50/60 Hz Power consumption max 6 VA Control outputs Q1, Q2, Q3 Rating Control output Y11, Y21 (NO contacts) Rating Signal input B1 for return air sensor Status input D1 and GND Contact sensing Insulation against mains Perm cable length with copper cable 15 mm 2 for connection to terminals B1, B2 and D1 AC 230 V max 600 VA AC 230 V max 300 VA QAH111, Safety class II NTC resistor 3kΩ at 25 C SELV DC 6-15 V / 3-6 ma 4 kv 80 m Setpoint setting range 830 C Max control deviation at 25 C max ±07 K Switching differential in heating mode SDH 1 K or 4 K (selectable) Switching differential in cooling mode SDC 05 K or 2 K (selectable) Dead zone in normal operation 2 K or 5 K Setpoint «Energy saving mode», heating 16 C Setpoint «Energy saving mode», cooling 28 C Setpoint «Standby» 8 C Operation Climatic conditions Temperature Humidity Transport Climatic conditions Temperature Humidity Mechanical conditions Storage Climatic conditions Temperature Humidity conformity to EMC directive Low voltage directive to IEC 721-3-3 class 3K5 0+50 C <95 % rh to IEC 721-3-2 class 2K3 25+70 C <95 % rh class 2M2 to IEC 721-3-1 class 1K3 25+70 C <95 % rh 89/336/EEC 73/23/EEC and 93/68/EEC N474 C-Tick conformity to EMC emission standard AS/NSZ 42511:1994 Product standards Automatic electrical controls for household and similar use Electromagnetic compatibility Emissions Immunity EN 60 730 1 and EN 60 730 2-9 EN 50 081-1 EN 50 082-1 Safety class II to EN 60 730 Pollution class normal Degree of protection of housing IP30 to EN 60 529 6/8

General Connection terminals Weight Colour of housing front Use solid wires or prepared stranded wires 2 x 04-15 mm 2 or 1 x 25 mm 2 023 kg White, NCS S 0502-G (RAL9003) Connection terminals L B1 M D1GND N Q1 Q2 Q3 Y11 N Y21 SELV 3023G01 L, N Operating voltage AC 230 V B1 Status input Return air temperature sensor M Measuring neutral Return air temperature sensor D1, GND Status input for potential-free operating mode changeover switch (operating action can be selected) Q1 Control output Fan speed I, AC 230 V Q2 Control output Fan speed II', AC 230 V Q3 Control output Fan speed III', AC 230 V Y11 Control output ' Valve, AC 230 V Y21 Control output Valve, AC 230 V Connection diagram L B1 S1 3023A01 B1 M1 N1 Return air temperature sensor (QAH111) Three-speed fan RCC30 room temperature controller S1 External operating mode changeover switch L B1 M D1 GND N Q1 Q2 Q3 Y11 N Y21 N1 Y1 Y2 Zone valve MVE/ MXE for heating mode Zone valve MVE/ MXE for cooling mode N I II III M1 Y1 Y2 N 7/8

Dimensions unit 114,15 3021M01 96,6 42,8 baseplate 4 28 28 30 28 35 28 4 11,8 104 4 26 30 90 3021M02 8/8 2003 Siemens Building Technologies AG Subject to alteration