D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Similar documents
Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

E2K-X4ME1 2M E2K-X4ME2 2M

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

Origin Position Control of an X-Y Table Coaxiality Inspection Checking Turret Indexing Position D5A

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

NPN output. 200 mm. Type Cable length Model Remarks

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Limit Switch Connectors

Limit Switch Connectors

Model Number Structure

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Model NPN output PNP output Standard. configuration

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

DPDT Basic Switch for Two Independent Circuit Control

Model Number Structure

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Photoelectric Sensor

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Intelligent Flag Amplifier

Handheld Reader Writer

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

NJ-Series Power Supply Unit NJ-PA/PD

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

Model Number Structure

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier

Model Number Structure

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch.

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Model Number Structure

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

Switching Frequency Test Conditions (AC3/AC4/AC53-a)

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Model Number Structure

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

Electroformed Probe Pins XP3A

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

ZE/ZV/ZV2/XE/XV/XV2. (1) Built-in Switch (3) Actuator (4) Conduit/Ground Terminal *

Peripheral Devices for Environment-resistive Slaves

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Model A7BS

Model A7D A7DP Screw mounting (back mounting) Snap-in (front mounting) Snap-in (front mounting)

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

ZE/ZV/ZV2/XE/XV/XV2. General-purpose Enclosed Switches with High Breaking Capacity and High Durability. Enclosed Switches. Model Number Structure

CSM_PYF S/P2RF- -S_DS_E_2_5

E4C-UDA CSM_E4C-UDA_DS_E_12_2

S82S (3/7.5-W Models)

Solid State Relays with Failure Detection Function

250 mm 1 m. Name Sensing distance Model Quantity Remarks 250 mm E39-R6 1 Supplied with the product. Reflectors 1 m [250 mm] * E39-R

A165K. Separate Construction with Cylindrical 16-dia. Body. Key-type Selector Switch (Detachable) (Cylindrical 16-dia.

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Model Number Structure

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

Model Number Structure

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Conductive Level Controller

Model NPN output PNP output Standard. configuration

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News

Multi-beam, finger- and hand protection safety sensor. Multi-beam, finger and hand protection safety sensor. Model number structure

Number of input channels

Through-beam pre-wired E3F1-TN11 2M *1 E3F1-TP11 2M *1 15 m. pre-wired E3F1-RN11 2M E3F1-RP11 2M 0.1 to 3 m

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

D4GS-N CSM_D4GS-N_DS_E_7_4

Model Number Structure

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

configuration Dark-ON/Light-ON (selectable) *3 Dark-ON/Light-ON (selectable) *3 Dark-ON/Light-ON (selectable) *3 Dark-ON/Light-ON (selectable) *3

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information

Thread length (overall length)

MGN. Ordering Information. Specifications. Heavy Duty Power Relay. Contact Data. 30 Amp Heavy Duty Relay. Heavy Duty Power Relay MGN 325

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

Transcription:

Mechanical Touch Switch D5B CSM_D5B_DS_E_3_2 Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics Slow-action switching mechanism used. Gold-plated contact with coil spring capable of switching micro current/voltage load while providing high contact reliability. Inputs directly to microcomputers and programmable controllers. Three sizes (M0, M, and M5) and three types of compact actuators. Easy panel mounting. Be sure to read Safety Precautions on page 4 and Safety Precautions for All Limit Switches. Model Number Structure Model Number Legend D5B-@@@ () (2)(3) () Size 5: M5 : M : M0 (2) Actuator 0: Hemispheric 02: Cone-shaped 5: Wobble stick (short spring) 53: Wobble stick (long spring). Only with the M0 type. (3) Cable length : m 3: 3 m 5: 5 m Ordering Information Type M5 M M0 Actuator Cable length (m) Model Model Hemispheric actuator D5B-50 D5B-0 D5B-0 3 D5B-50 D5B-0 D5B-0 5 D5B-505 D5B-05 D5B-05 Cone-shaped actuator D5B-502 D5B-02 D5B-02 3 D5B-5023 D5B-023 D5B-023 5 D5B-5025 D5B-025 D5B-025 Wobble stick actuator Short spring Long spring D5B-55 D5B-5 D5B-5 3 D5B-55 D5B-5 D5B-5 5 D5B-555 D5B-55 D5B-55 D5B-53 3 --- --- D5B-533 5 D5B-535

Specifications D5B Ratings Electrical ratings Characteristics Degree of protection Durability Structure and Nomenclature Structure Mechanical Electrical Operating speed Operating Mechanical frequency Electrical Insulation resistance Contact resistance Dielectric strength (50/60 Hz min) Between terminals of same polarity Between each terminal and non-current-carrying metal parts ma at 5 VDC to 30 ma at 30 VDC (resistive load) IP67 0,000,000 operations min. 5,000,000 operations min. (at 30 ma 30 VDC resistive load) 5 to 500 mm/s 20 operations/min. 60 operations/min. 00 MΩ min. at 250 VDC between each terminal and non-current-carrying metal parts With m cable:700 mω max. (initial value) With 3 m cable:.9 Ω max. (initial value) With 5 m cable:3. Ω max. (initial value) 250 VAC (at TTP),000 VAC (600 VAC for M5 model) Vibration resistance Malfunction 0 to 55 Hz,.5-mm double amplitude 2 Shock Mechanical,000 m/s 2 max. resistance Malfunction 300 m/s 2 max. 3 Ambient operating temperature 0 C to +70 C (with no icing) Ambient operating humidity 35% to 95%RH Actuator strength 4.7 N 4 Weight Switch M5: Approx. 4 g, M: Approx. 20 g, M0: Approx. 2 g Cable Approx. 0 g/m Actuator (POM) Rubber boot (NBR) Plunger (POM) Reset spring Case (PBT) Base Resin Cable (V-HKCVV) Contact Form Engineering Data Electrical Durability (cosφ=) (Operating temperature: +5 C to +35 C, Operating humidity: 40% to 70%RH.) Durability ( 0 4 operations) 5,000 3,000,000 700 500 300 200 00 30 VDC 0 0 20 30 40 Switching current (ma) Note: The above figures are initial values.. Durability values are calculated at an operating temperature of +5 C to +35 C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. 2. 6.7 Hz, -mm double amplitude for wobble stick models. 3. 50 m/s 2 max. for wobble stick models. 4. Excluding the wobble stick models. (Normally closed contact) Brown Blue Note: Specifications for normally open (N.O.) contacts are not available. Axis Reset spring Mounting nut Dimensions and Operating Characteristics (Unit: mm) Dimensions M5 Type (The square @ in the models represents the cable length. Refer to Ordering Information.) D5B-50@ 2.4 5.9 (24.5) 6.2 4.3 (Ball 2.5R) 2.5 Clamping nut equal level, 3 Operating characteristics (X, Y) measuring position D5B-502@ 4.9 5.9 (27) 6.2 4.3 0.5R Clamping nut equal level, 3 Operating characteristics (X, Y) measuring position D5B-55@ (64.) 4.9±2 6 6.2 4.3 2.3 5 0.4 2 6.9 ±2 Operating characteristics (X, Y) measuring position Clamping nut equal level, 3 Note:. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. The threads of the case are not standard; 0.5-mm pitch. Therefore standard tapping to the case is not possible for mounting. 2

D5B M Type D5B-0@ 4 (2) 6.7 (5) 7 (Ball 3.5R) M 0.5 equal level, 3 3.5 Clamping nut 0.0 mm 2 Two conductors Operating characteristics (X, Y) measuring position D5B-02@.5 (3) 6.7 (5) 7 0.R M 0.5 equal level, 3 Clamping nut Operating characteristics (X, Y) measuring position D5B-5@ 6.±2 (92.) 6.7 (5) 7 3.9 5. 3 ±2 M 0.5 equal level, 3 Clamping nut Operating characteristics (X, Y) measuring position M0 Type D5B-0@ 5.5 (33.3) 5 9 Ball 4.5R M0 0.5 equal level, 3 4.5 Clamping nut Operating characteristics (X, Y) measuring position D5B-5@ (.) 3.3 5 9 4.6 5 5.3 Operating characteristics (X, Y) measuring position M0 0.5 Clamping nut S-FLEX V-HKCVV equal level, 3 D5B-02@ (39.3).5 5 9 0.9R M0 0.5 equal level, 3 Clamping nut Operating characteristics (X, Y) measuring position D5B-53@ (.) 3.3 5 9 4.6 5 5 33.3 Operating characteristics (X, Y) measuring position M0 0.5 Clamping nut S-FLEX V-HKCVV equal level, 3 Note:. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. The threads of the case are not standard; 0.5-mm pitch. Therefore standard tapping to the case is not possible for mounting. 3

D5B Operating Characteristics Actuator Hemispheric Plunger Cone-shaped Plunger Wobble Stick Operating direction Operating characteristics Total travel TT Operating force OF (max.) Permissive operating force (max.) Pretravel PT Reference value Type M5 M M0 M5 M M0 M5 M M0 X, Y.0 mm.2 mm.3 mm 2.2 mm 3.0 mm 4.0 mm 22 mm 23 mm 30 mm Z 0. mm 0.9 mm.0 mm 0. mm 0.9 mm.0 mm --- X, Y 0.49 N 0.74 N 0.9 N 0.20 N 0.20 N 0.39 N 0.05 N Z 0.74 N 0.9 N.47 N 0.74 N 0.9 N.47 N --- X, Y, Z.96 N.96 N 0.49 N X, Y mm mm 0.7 mm mm.4 mm 2.0 mm mm mm 4 mm Z 0.3 mm 0.3 mm 0.3 mm 0.3 mm 0.3 mm 0.3 mm --- --- --- Safety Precautions Refer to Safety Precautions for All Limit Switches. Handling Precautions for Correct Use Do not impose a load exceeding 29.42 N on the cable, otherwise the cable may break. If the cord is to be bent repeatedly, make sure that the bending radius is at least R20 mm. Mounting Do not tighten the nuts with excessive torque. Refer to the following for the appropriate tightening torque and mounting dimensions of each nut. The base incorporates special threads that cannot be mounted to plates with standard tap holes. Type M5 M M0 Appropriate Tightening Torque (max.) 0.9 N m 2.94 N m 3.92 N m Size Type M5 M M0 A (Mounting 5 0 mm 0 mm 0 0 mm hole size) B (Panel thickness) C (Toothed lock washer diameter) 3 to 7 mm 9.2 mm 4 to 6 mm 5 mm 6 to 0 mm mm Operation Do not impose excessive force on the actuator. Even though the actuator withstands a maximum force of 4.7 N, if the D5B is repeatedly actuated, make sure that the maximum force imposed on the actuator is.96 N. If the actuator is, however, a wire spring type, the maximum force imposed must be 0.49 N instead. The operating characteristics of the D5B vary with the direction (i.e., X, Y, or Z) in which force is imposed. Refer to above. The wobble stick model is actuated when force is imposed on the tip of the wobble stick and the built-in switch unit is closed or opened. This is different from the NL Limit Touch Switch or D5C Column Touch Switch in terms of the main mechanism. The NL or D5C is actuated when the actuator comes into contact with an actuating object. The wobble stick model may break if the stroke is excessive. Make sure that the total travel (TT) is within the reference value provided in the datasheet. Attach an appropriate cover for protecting the D5B from direct exposure to sprayed oil or water. No protective cover is, however, provided together with the D5B. The D5B may be damaged by ozone and failures may result if the D5B is used outdoors. Consult your OMRON representative before attempting to use the D5B outdoors. Outdoor environmental conditions may have a bad influence on the service life of the D5B. Refer to the general precautions of Limit Switches for details. The base may be deformed if it is subjected to an excessive load. Be careful when mounting the Switch. 4

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 202. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 202 All Right Reserved.