Model VDL 115 Vacuum drying chambers for flammable solvents

Similar documents
Model VD 23 Vacuum drying chambers for non-flammable solvents

Model KB 240 Cooling incubators with compressor technology

Model KB 400 Cooling incubators with compressor technology

Datasheet.

Model KB 400 Cooling incubators with compressor technology

Model KT 53 Cooling incubators with thermoelectric cooling

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KBW 720 Growth chambers with light

Model KB 400 Cooling incubators with compressor technology

Model KT 53 Cooling incubators with thermoelectric cooling

BINDER Inc. North America. Scientific Products Pricelist 2010 Issue 2/10

Refrigerated incubators with forced convection

Environmental simulation chambers MK MKF MKT MKFT

Drying and heating chambers. Series ED FD FED FP M

Temperature Measurement SITRANS TS300

Gas-actuated thermometer Stainless steel version Model 73

NEW NEW. Diaphragm agm Pumps MPC for Chemical Applications MPC 301 E. MPR 060 E with power pack

Heratherm Compact Microbiological Incubators

Cooled incubators (ST), laboratory refrigerators

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Customer Responsibilities

ProcessCalibrator Model CPH6000

Pneumatic Control/Feedback

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

D Issue A. Instruction Manual. Active Strain Gauge

Interface I-300 / I-300 Pro Technical data sheet

Precision digital pressure gauge Model CPG1500

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Float Switches with Permanent Magnet For Vertical Installation Model RSM

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

PI 500 Hand-held instrument for industry

Grounding Monitoring Device Series 8485

Hand-Held Pressure Indicator

Flow Measurement SITRANS F M

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Pneumatic Control/Feedback

801 Stirrer. Manual EN

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Intrinsically safe Hand-Held Pressure Indicator (ATEX-version) Model CPH62I0

Digital Positioner 8049

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Flow VA 500/

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

Precision hand-held pressure indicator Model CPH6400

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

ProcessCalibrator Model CPH6000

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Precision thermometer Model CTR5000

Industrial pressure controller Model CPC4000

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Immersion Temperature Sensors

Interface I-300 / I-300 Pro Technical data sheet

Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 65 - DN 100

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Chart recorder. DS 500 mobile Intelligent mobile chart recorder

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 65 - DN 125

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

The VARIO Chemistry-pumping units with adaptive vacuum control

Threaded resistance thermometer Miniature design Model TR10-D

Micro calibration bath Models CTB , CTB

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Portable pressure calibrator Model CPH7600

Product manual plug, sockets and coupler 16 A.- Z0251

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

Air data test indicator Model CPA2501

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Precision digital pressure gauge Model CPG1500

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

IDS 500 mobile Intelligent mobile chart recorder

Avanti HP Series Centrifuges Preinstallation

High-end pressure controller Model CPC8000

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

ProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements

Digital electropneumatic Positioner for the integrated mounting on process control valves

Old documentation - Only for your information! Product is not available anymore!

Linear Luminaire with LED Series 6012/5

FOX-50 Heat Flow Meter

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Technical Data. General specifications. Rated operating distance s n 3 mm

SolConeX extra-low voltage flange socket

Hand-Held Thermometer Model CTH 6200

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

SolConeX Wall-Mounted Socket, 16 A

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

SMART is the right way to do something in the Lab as well.

IKA Crushing 76 Dispersers (batch operation)

Transcription:

Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber of the VDL safety vacuum drying oven is designed according to ATEX guidelines 2014/34/EU Ex II -/3G c IIB T3-T1 Gc X. BENEFITS Fast and gentle drying Direct heat transfer through large thermal conducting plates Safe work with one-of-a-kind safety concept Coordinated, modular system with vacuum pump and vacuum module MAIN FEATURES Model 115 Model 115 Temperature range: room temperature plus 15 C to 200 C ATEX compliance chamber's interior: Ex II -/3G c IIB T3-T1 Gc X APT.line preheating chamber technology Controller with time-segment and real-time programming 2 aluminum expansion racks Inert gas connection Shatterproof, spring-mounted safety glass panel Pressurized instrument panel with compressed air connection Pressure control device for heating activated < 125 mbar Flame protection gasket Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm Computer interface: RS 422 ORDERING INFORMATION Interior volume [L] Voltage Option model Version Art.-No. Model VDL 115 115 230 V 1~ ph 50/60 Hz Standard VDL115-230V 9030-0040 TECHNICAL DATA Description VDL115-230V 1 Article Number 9030-0040 Performance Data Temperature Temperature range 15 C above ambient temperature to [ C] 200 Temperature variation at 100 C [± K] 3.5 Temperature fluctuation [± K] 0.1 Heating-up time to 100 C [min] 95 1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 C ±3 C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time. Page 1 / 5

Description VDL115-230V 1 Article Number 9030-0040 Vacuum Data Permitted end vacuum [mbar] 0.01 Leak rate [bar/h] 0.01 Electrical data Rated Voltage [V] 230 Power frequency [Hz] 50/60 Nominal power [kw] 1.9 Unit fuse [A] 10 Phase (Nominal voltage) 1~ Connections Vacuum connection with small flange [DN mm] 16 Measuring access port with small flange [DN mm] 16 Inert gas connection with flow limiter (RP") 3/8 Compressed air connection for pressure-encapsulation [mm] 8 Outer dimensions Width net [mm] 740 Height net [mm] 900 Depth net [mm] 670 Wall clearance back [mm] 100 Wall clearance sidewise [mm] 135 Viewing window width [mm] 456 Viewing window height [mm] 413 Doors Unit doors 1 Internal Dimensions Width [mm] 506 Height [mm] 506 Depth [mm] 460 Measures Interior volume [L] 115 Net weight of the unit (empty) [kg] 153 permitted load [kg] 65 Load per rack [kg] 20 Fixtures Number of shelves (std./max.) 2/6 1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 C ±3 C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time. DIMENSIONS incl. fittings and connections [mm] Page 2 / 5

OPTIONS AND ACCESSORIES Designation Description * Art.-No. Calibration certificate, expanded for temperature; for extending the measurement in center of chamber to include another test temperature 8012-1128 Calibration certificate, temperature for temperature, measurement in center of chamber at specified temperature 8012-1146 temperature measurement incl. certificate, 15-18 measuring points at specified temperature 8012-1583 temperature measurement incl. certificate, 9 measuring points at specified temperature 8012-1562 Door gasket made of FKM, silicone-free 03 8012-1318 Electric access port Expansion rack Interface converter Interface converter, USB / RS422 9-pin, vacuum-tight access port for transmitting electrical currents, voltages, or signals (max. 50 V / 2 A per pin; vacuum connection DN 16 ISO-KF) 8012-1238 aluminum 8009-0372 stainless steel 1.4571 (V4A) 06 8009-0103 stainless steel expansion rack instead of standard aluminum expansion rack, incl. calibration 8012-1424 RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit 230 V, 50/60 Hz option model 8012-0556 RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit 230 V, 50/60 Hz option model 8012-0380 RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) 8012-0665 ph-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg 1002-0016 RS 422 interface modular plug distributor for 10 RS 422 interfaces 8012-0295 RS 422 interface, cable (15 m) RS 422 interface, cable (50 m) Software Temperature measurement of the specimen RS 422 connection cable (15 m) between plug distributor and RS 422 interface 5023-0036 RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor 5023-0117 APT-COM communications software version 2 to 3, GLP edition 19 9053-0016 version 3, BASIC edition 19 9053-0014 version 3, GLP edition 19 9053-0015 version 3, STANDARD edition 19 9053-0013 APT-COM communications software, price: for free version 3, GLP DEMO Edition 19 9053-0008 using flexible Pt 100 sensor (EX-proof via current-measurement access port) and digital temperature display 8012-0574 Vacuum module to receive vacuum pumps 8012-0692 Vacuum module with vacuum pump VP 4 Vacuum module with vacuum pump VP 5 Vacuum pump connection kit (ATEX) Vacuum pump VP 4 Vacuum pump VP 5 * Notes See last page ATEX compliant chemical membrane pump with nominal pumping speed 1,9 m³/h, final pressure 12 mbar, with separator and emission condenser, including all necessary parts for vacuum connection ATEX compliant chemical membrane pump with nominal pumping speed 3,7 m³/h, final pressure 3 mbar, with separator and emission condenser, including all necessary parts for vacuum connection for vacuum pump VP 4; consisting of clamping rings, universal centering rings, transition piece, anti-static vacuum hose, union nut, and elbow for vacuum pump VP 5; consisting of clamping rings, universal centering rings, transition piece, anti-static vacuum hose, union nut, and elbow Chemical membrane pump with nominal pumping speed 1.9 m³/h, final pressure 12 mbar, with separator and emission condenser, ATEX conformity: Suction chamber (pumped gases): II 2G IIC T3 X, exterior with inert-gas flushing: II 2G IIB T4 X, exterior without inert-gas flushing: II 3G IIB T4 X, motor: II 2G Ex d IIB T4 Gb 8012-0383 8012-0385 8012-0621 8012-0622 230 V / 50 Hz option model 5013-0049 Chemical membrane pump with nominal pumping speed 3.7 m³/h, final pressure 3 mbar, with separator and emission condenser, ATEX conformity: Suction chamber (pumped gases): II 2G IIC T3 X, exterior with inert-gas flushing: II 2G IIB T4 X, exterior without inert-gas flushing: II 3G IIB T4 X, motor: II 2G Ex d IIB T4 Gb 230 V / 50 HZ option model 5013-0050 Page 3 / 5

SERVICES Designation Description * Art.-No. Installation services Installation and set up of unit at operating location, connect to existing connections 13, 18 DL10-0100 DL10-0200 Instruction unit function instructions for operation and programming of the controller 18 DL10-0500 Preventive maintenance Preventive maintenance Executive of equipment inspection according to maintenance plan 14, 18 DL20-0400 Calibration services Calibration digital pressure display including certificate, measurement at specified pressure, range 20 900 mbar 17, 18 DL32-0000 Calibration temperature incl. certificate including certificate, one measuring point in center of chamber at specified temperature DL30-0101 17, 18 DL30-0201 Temperature measurement 15 measuring points including certificate, 15 measuring points at specified temperature 17, 18 DL30-0218 Temperature measurement 9 measuring points Validation services including certificate, 9 measuring points at specified temperature DL30-0109 17, 18 DL30-0209 Execution of IQ/OQ in accordance with qualification folder 15, 18, 20 DL42-0300 Execution of IQ/OQ/PQ in accordance with customer's requirement, price: on request 15, 18 DL44-0500 Qualification folder IQ/OQ supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 15, 18, 20 8012-0860 Qualification folder IQ/OQ/PQ Warranty service supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ 15, 18 8012-0949 Extension of the warranty from 2 to 3 years Extension of the warranty from 2 to 5 years beginning with the date of delivery, wearing parts are not included DL00-9041 beginning with the date of delivery, wearing parts are not included DL00-9042 * Notes See last page Page 4 / 5

NOTES 01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. 02 UL mark is not granted when this option is used. 03 Heat resistant only to max. 200 C. 04 Only available on units rated for 230 V. 06 Heating-up time may increase as a result of the lower heat conductivity. 07 The additional heat input may affect the temperature behavior. 09 Not in conjunction with the optional access port, door with window and interior lighting. 10 Not available on 23-liter units. 11 Not available on 23- or 53-liter units. 12 Only available on units rated for 230 V or 400 V. 13 Installation and connections take place at unit location; transport within the company only upon consultation. 14 We recommend a BINDER service contract to cover unit inspections, calibrations and validations. 15 OQ according to Yellow Paper = completed factory validation documentation of all OQ checklists. 16 Sensor calibration is performed in an accredited calibration laboratory. 17 Calibration is performed according to the BINDER factory standard. 18 Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not include a country-specific added fee (available on request). 19 For additional accessories, refer to the Process documentation chapter. 20 When ordering IQ/OQ qualification folders and associated IQ/OQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ folder. When ordering IQ/OQ/PQ qualification folders and associated IQ/OQ/PQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ/PQ folder. Page 5 / 5