Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43

Similar documents
Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

Determination of primary electron beam parameters in a Siemens Primus Linac using Monte Carlo simulation

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR

Indrin Chetty Henry Ford Hospital Detroit, MI. AAPM Annual Meeting Houston 7:30-8:25 Mon 08/07/28 1/30

Comparison Study of Monte Carlo Simulations and Measurements of Relative Output Factors of 6 MV Photon Beam

Implementation of a double Gaussian source model for the BEAMnrc Monte Carlo code and its influence on small fields dose distributions

Megan A. Wood, M.S. Under the direction of Larry DeWerd, Ph.D. University of Wisconsin Medical Radiation Research Center (UWMRRC)

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code

Evaluation of latent variances in Monte Carlo dose calculations with Varian TrueBeam photon phase-spaces used as a particle source

Room scatter effects in Total Skin Electron Irradiation: Monte Carlo simulation study

Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam

Monte Carlo evaluation of the dosimetric uncertainty in matched 6 MV Elekta and Varian linear accelerators

An investigation into the use of MMCTP to tune accelerator source parameters and testing its clinical application

BEAMDP Users Manual. C.-M. Ma and D.W.O. Rogers Ionizing Radiation Standards National Research Council of Canada, Ottawa

Radiation Beam Characterization and Dosimetry of Theratron Equinox-80 Telecobalt Machine Using BEAMnrc Monte Carlo Simulation Code

I. INTRODUCTION. Figure 1. Radiation room model at Dongnai General Hospital

A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface

Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

THE SIMULATION OF THE 4 MV VARIAN LINAC WITH EXPERIMENTAL VALIDATION

Monte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters

Source Model Tuning for a 6 MV Photon Beam used in Radiotherapy

Improvements in Monte Carlo simulation of large electron fields

Monte Carlo simulation of beam characteristics from small fields based on TrueBeam flattening-filter-free mode

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

Shielding factors for traditional safety glasses

87.55.K-, Gh, km, Ca. Agility, analytic model, Elekta, Monaco, Monte Carlo, virtual source

Output factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery system

Monte Carlo modeling of a Novalis TX Varian 6 MV with HD-120 multileaf collimator

ELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS

A SYSTEM OF DOSIMETRIC CALCULATIONS

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

I Introduction 2. IV Relative dose in electron and photon beams 26 IV.A Dose and kerma per unit incident fluence... 27

Implementation of Monte Carlo Dose calculation for CyberKnife treatment planning

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Monte Carlo Simulations of. Chemical Vapour Deposition. Diamond Detectors

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations

Photon beam dose distributions in 2D

Comparison of measured and Monte Carlo calculated electron beam central axis depth dose in water

Basic Radiation Oncology Physics

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

Transitioning from pencil beam to Monte Carlo for electron dose calculations

UNIVERSITY OF CALGARY. Monte Carlo model of the Brainlab Novalis Classic 6 MV linac using the GATE simulation. platform. Jared K.

VALIDATION OF A MONTE CARLO DOSE CALCULATION ALGORITHM FOR CLINICAL ELECTRON BEAMS IN THE PRESENCE OF PHANTOMS WITH COMPLEX HETEROGENEITIES

Monte Carlo investigation of collapsed versus rotated IMRT plan verification

Basics of treatment planning II

gpmc: GPU-Based Monte Carlo Dose Calculation for Proton Radiotherapy Xun Jia 8/7/2013

Basics of treatment planning II

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them

BRAZILIAN JOURNAL OF RADIATION SCIENCES (2018) 01-14

Outline. Monte Carlo Radiation Transport Modeling Overview (MCNP5/6) Monte Carlo technique: Example. Monte Carlo technique: Introduction

Monte Carlo simulations. Lesson FYSKJM4710 Eirik Malinen

Clinical implementation of photon beam flatness measurements to verify beam quality

Application of efficient Monte Carlo photon beam simulations to dose calculations in voxellized human phantoms

Monte Carlo Treatment Planning: Implementation of Clinical Systems

Monte Carlo simulations

Comparison of Predictions by MCNP and EGSnrc of Radiation Dose

Effects of the difference in tube voltage of the CT scanner on. dose calculation

Investigation of photon beam output factors for conformal radiation therapy Monte Carlo simulations and measurements

2D DOSE MEASUREMENT USING A FLAT PANEL EPID

AN ABSTRACT OF THE DISSERTATION OF

A virtual photon energy fluence model for Monte Carlo dose calculation

Monte Carlo Methods for Accelerator Simulation and Photon Beam Modeling

EXTERNAL PHOTON BEAMS: PHYSICAL ASPECTS

On compensator design for photon beam intensity-modulated conformal therapy

Verification measurements of an emc algorithm using a 2D ion chamber array

CLINICAL ASPECTS OF COMPACT GANTRY DESIGNS

Dynalog data tool for IMRT plan verification

MPEXS benchmark results

Proton dose calculation algorithms and configuration data

Application of MCNP Code in Shielding Design for Radioactive Sources

Construction of Voxel-type Phantom Based on Computed Tomographic Data of RANDO Phantom for the Monte Carlo Simulations

Verification of dose calculations with a clinical treatment planning system based on a point kernel dose engine

Machine and Physics Data Guide

Suitability Study of MCNP Monte Carlo Program for Use in Medical Physics

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

THESIS NEUTRON PRODUCTION AND TRANSPORT AT A MEDICAL LINEAR ACCELERATOR. Submitted by. Amber Allardice

Accuracy of treatment planning calculations for conformal radiotherapy van 't Veld, Aart Adeodatus

Photon Dose Algorithms and Physics Data Modeling in modern RTP

Suggesting a new design for multileaf collimator leaves based on Monte Carlo simulation of two commercial systems

Dose Calculations: Where and How to Calculate Dose. Allen Holder Trinity University.

Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms.

MEASUREMENTS OF AIR KERMA AS FUNCTION OF POTENTIAL IN X-RAY TUBES FOR ESTIMATES STANDARD QUANTITIES USED FOR DOSIMETRIC EVALUATION

A CT-based Monte Carlo Dose Calculations for Proton Therapy Using a New Interface Program

Release Notes for Dosimetry Check with Convolution-Superposition Collapsed Cone Algorithm (CC)

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS

The IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved

FAST, precise. qa software

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 1, 2014

Getting Started with EGSnrc

Intensity-modulated radiation therapy dose maps: the matchline effect

Breaking Through the Barriers to GPU Accelerated Monte Carlo Particle Transport

15 Dose Calculation Algorithms

Michael Speiser, Ph.D.

A dedicated tool for PET scanner simulations using FLUKA

Op#miza#on of CUDA- based Monte Carlo Simula#on for Radia#on Therapy. GTC 2014 N. Henderson & K. Murakami

Transcription:

International Journal of Innovation and Applied Studies ISSN 2028-9324 Vol. 6 No. 3 July 2014, pp. 635-641 2014 Innovative Space of Scientific Research Journals http://www.ijias.issr-journals.org/ Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43 Maged Mohammed 1-2, T. El Bardouni 1, H. Boukhal 1, M. Azahra 1, and E. CHAKIR 2 1 Radiations and Nuclear Systems Laborator, University Abdelmalek Essaadi, Faculty of Sciences, Tetouan, Morocco 2 LHESIR, Ibn Tofail University, Faculty of sciences, Kenitra, Morocco Copyright 2014 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. ABSTRACT: The Monte Carlo method is the most accurate method for the simulation of radiotherapy equipment. Linear accelerator (Linac) is currently the most widely used in radiotherapy center's machines. In this work we run the Monte Carlo code EGSnrc under the platform BEAMnrc to calculation of important photon beam parameters by modeling the head of the linear accelerator SATURNE43.The aim of this study was to calculate the dosimetric functions, namely: the dose profile and Percentage depth dose (PDD) for a 12 MV photon beam generated by Linac SATURNE43 and delivered in a water phantom. Photons are generated by the bremsstrahlung effect of electrons during interaction with the tungsten target. All calculations are done by considering a square field dimension 10x10cm² at a depth z = 100 cm from the target. Analysis of the data stored in the phase space is performed and photons spectrum is extracted. The PDD and the 10cm depth dose profile distributions are compared to experimental data by the Monte Carlo code EGSnrc under the platform BEAMnrc. A good agreement is obtained for both distributions and a reasonable computing time is obtained by use of the following fundamental parameters of the simulation: ECUT = 0.4MeV, PCUT = 0.12MeV, FWHM = 0.17cm and ESAVE = 1MeV. KEYWORDS: SATURNE43, Monte Carlo, EGSnrc, dose distribution, TPS. 1 INTRODUCTION The aim of using external radiotherapy in cancer treatment using high radiation doses from photon or electron beams. Healthy tissues and organs at risk surrounding the tumor should be preserved during treatment by the optimization of the irradiation parameters using a convenient Treatment Planning System (TPS). However, a quality control program should be implemented to compare the results provided by the TPS with experimental data. The experimental data are obtained by measurement of dosimetric parameters such as dose profile and percentage depth dose (PDD) [8]. There are innumerable dosimetry techniques already available that compare experimental results with Monte Carlo simulations. Also the precise prediction of the absorbed dose distributions in patients irradiated by clinical beams plays an important role in radiotherapy treatment. A Monte Carlo method is the most accurate way to calculate it [4]. In this work we use the EGSnrc / BEAM code for modeling the head of a linear accelerator SATURNE43 and calculate the dose distribution across the phantom. BEAMnrc is a Monte Carlo code system for simulating radiation therapy sources. It was developed as part of the OMEGA project a collaboration between the National Research Council of Canada and a research group at the University of Corresponding Author: Maged Mohammed 635

Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43 Wisconsin Madison. It is based on the EGS code system for the coupled transport of electrons and photons BEAMnrc is a package of codes for building accelerator geometries and for evaluating the results of simulations through those geometries. The geometry of the accelerator to be simulated is built up from a series of predefined component modules (CMs), BEAMnrc can model all types of medical linear accelerators, using the code component module system [1, 9]. The OMEGA project can be divided into three stages: an accelerator simulation, characterization and representation of the beam and the dose calculation. The modeling of the head of a medical linear accelerator is the most important part of the program (BEAMnrc) [1, 7]. The code BEAMnrc can produce a so called phase space file of the beam at specified scoring planes on the model, these planes are to be placed at the back of an already defined CM and the planes have to be perpendicular to the central-axis. A phase space file contains full information (charge, energy, position and direction) about the particles crossing the scoring plane. BEAMnrc also offers a variety of radiation sources (point source, a source that emits radiation isotropic ally over a specified volume, phase space file as source, etc...) and some so called variance reduction techniques to speed up the calculations. BEAMnrc is considered as a reference in radiation therapy where they are compared to the results of other codes with this code. 2 MATERIALSA ND METHODS 2.1 MEASUREMENT DATA Measurement data of depth dose or off-axis lateral dose was obtained from EURADOS group [5]. 2.2 MONTE CARLO SIMULATION PARAMETERS The Simulate linear accelerator Saturn 43 by method of Monte Carlo was done in two steps: 2.2.1 SIMULATION THE HEAD OF THE LINEAR ACCELERATOR SATURNE 43 We constructed the model of the LINAC Saturne 43 geometry using Monte Carlo code BEAM/EGSnrc. The different components of the irradiation head were modeled using the modules (CM) Code. The model of the accelerator is comprised of a succession of planes perpendicular to the z axis in a module which is horizontal planes. Each CM is independent of the others and is distinguished by its numbering. The same CM can be used several times without interacting with the previous ones. It is the user who connects to each other. A module can be considered as a block having an input surface and an output surface. CMs are composed of elements that are numbered in the double direction of increasing z. BEAMnrc uses a local numbering according to the CM and a second global numbering based on the entire accelerator. This allows the code to follow the path and interactions experienced by the particles in the accelerator head. The components were applied to model the target, primary collimator, flattening filter, monitor chamber and jaws. Thereafter, a compilation is necessary to allow verification of the geometric model of overlap between components, it allows the generation of the necessary files to the code execution, as mortjob.mortan file that contains the definition of the different parameter simulation [1, 6, 7 ]. At the end of this step, the components of a linear accelerator for a 12MV photon beam are shown in Figure (1) ISSN : 2028-9324 Vol. 6 No. 3, July 2014 636

Maged Mohammed, T. El Bardouni, H. Boukhal, M. Azahra, and E. CHAKIR Phase space Fig. 1. Saturne 43 Linac head modeling by BEAMnrc code in 2D geometry During this study the variance reduction techniques used are: The energy Cutoffs for photons and electrons respectively were set to 120 kev,400kev Bremsstrahlung splitting is DIRECTIONAL ESAVE =1MeV (Energy in MeV below which electron will be discard in range rejection) The parameters of the source of electrons: Source number. 19 define a source with Gaussian distribution in the X and Y plane incident from the front. for mono energetic beam Equal 11.4MeV Gaussian distribution (x-y plane) with origin on beam axis for FWHM =1.7mm and BEAM SIGMA= 0.0722 cm In our study the phase space obtained for these parameters is calculated at -50 cm from the tungsten target by simulating 60 x 106 mono-directional incident electrons. A phase space file of roughly 4GB is created and it contains about 32.106 photon tracks and 2 x 105 electron tracks. Other files can be saved for the dose and the statistical uncertainty in the various components of the treatment head these files have an extension egslst. 2.2.2 SIMULATION OF DOSE DISTRIBUTION IN THE WATER PHANTOM In this step we calculate the dose distribution in water Phantom by Code dosxyz. DOSXYZnrc is an EGSnrc-based Monte Carlo simulation code for calculating dose distributions in a rectilinear voxel phantom and is based directly on the DOSXYZ code developed for the EGS4 code system. DOSXYZnrc is part of the OMEGA BEAM system of codes developed at NRC. Density and material in every voxel may vary. A variety of beams may be incident on the phantom, including full phase-space files from BEAMnrc, In order to calculate the dose distribution must be defined Phantom of water, the source of the particles, the parameters of code Dosxyz and The EGSnrc Parameters [2]. ISSN : 2028-9324 Vol. 6 No. 3, July 2014 637

) Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43 In this step the phase space file is used as a source and is put at 40cm from the water phantom, a water phantom with dimensions of 40 cm 40 cm 40 cm was simulated under the gantry with a source-surface distance (SSD) of 90 cm. The phantom was divided into voxels, with each voxel's dimensions being 5 mm 5 mm 5 mm, in which we collected the energy deposited to calculate the relative dose absorbed in the phantom. The percentage depth dose (PDD) and beam profiles were calculated in a water phantom a square field dimension 10x10cm² at a depth z = 100 cm from the target. We simulated 5.108 particles with the module DOSXYZnrc. We then compared them with measurements for validation of our Monte Carlo model. 3 RESULTS The curves of PDD are normalized at 10cm depth and are obtained for a field size of 10x10cm2 and a SSD= 90cm, and lateral dose profile normalized at 10cm in water. In Fig. 2, 3 we show experimentally measured data and EGSnrc/BEAMnrc Monte Carlo simulation results. (2) Shows the depth-dose curves, (3) shows lateral dose profile at 10 cm depth, for the 10 10 cm2 field, And (3) we show laterals dose profiles at 0, 5, 10, 15, 20 cm depth, with the 12MV beam (SSD = 90 cm) Fig. 2. PDD comparison between measurement and MC simulation for 12MV, filed size 10 10 cm2 X (cm) Fig. 3. lateral profile comparison between measurement and MC simulation ISSN : 2028-9324 Vol. 6 No. 3, July 2014 638

Maged Mohammed, T. El Bardouni, H. Boukhal, M. Azahra, and E. CHAKIR X (cm) Fig. 4. Lateral dose profiles at 0, 5, 10and 20 cm depth for 10 10 cm 2 field with a 12MV beam. In Figure (2, 3) We note there is good agreement between calculated and measured results, In (2) depth dose matched perfectly with a few of the disagreement around the dose build- up point, In (3) lateral dose profile the values so close with a very slight statistical difference in central plateau may fade with time simulation or increase the number of particles simulated In Figure (4) Lateral dose profiles are very sensitive to the depth in a phantom. The results show that increasing the depth tends to reduce the dose in two areas: central plateau and darkness. As against, lateral dose profiles outside the field is less sensitive than the depth. To analyses of the data stored in the phase space and photons spectrum Performs by BEAMDP Code, BEAMDP (BEAM Data Processor) is a program developed for the OMEGA (Ottawa Madison Electron Gamma Algorithm) project[3], the phase space file was generated by BEAMnrc at z =50cm, for 12MV. These file was analyzed, and the characteristics of the particles they contained were plotted. The graphs that were taken from BEAMDP were Mean Energy, Energy Fluence vs. position, Energy Fluence distribution and distribution the Particle in x-y plane, As shown in Figures 5,6,7and 8 Fig. 5. Energy Fluence vs. Position for 12MV on X and Y axis Fig. 6. Mean Energy ISSN : 2028-9324 Vol. 6 No. 3, July 2014 639

Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43 Fig. 7. Energy Fluence Distribution Fig. 8. distribution the Particles in x-y plane In Figures 5, 6, 7 and 8, we note that BEAMDP is very effective for spectral beam analysis and validation of the field that we use in the simulation and it is necessary to analyze the errors that may be associated with simulation. So it is very important in the planning of radiotherapy. 4 CONCLUSION in this work, we have modeled the medical linear accelerator Saturn 43 by EGSnrc/BEAMnrc Code, the results which obtained by EGSnrc simulation are acceptable and shows Excellent agreement and a slight statistical difference with the experimental results, so we mastered the installation and operation of this system for the simulation of linear accelerator used in radiotherapy. Accuracy of this method in the calculation of the dose distribution and analysis of the data stored in the phase space file so we can use this code in the treatment planning system of radiation therapy, to improve the statistical simulations, we see, firstly study the effect of certain components of the head SATURN 43 of dose distributions and the energy spectrum of photons as the flattening filter and jaws Secondly the different variance reduction techniques for Optimizing simulation in terms of time. ACKNOWLEDGMENTS I want to thank my supervisor pr. Tarek EL Bardouni for guiding me and I thank him very much for welcoming me in his laboratory, its availability and for his invaluable assistance in the completion of this work and especially for the supervision of this work, also extend my sincere thanks to Prof E. Chakir, H. Boukhal and M. Azahra for their collaboration and technical support to this work. ISSN : 2028-9324 Vol. 6 No. 3, July 2014 640

Maged Mohammed, T. El Bardouni, H. Boukhal, M. Azahra, and E. CHAKIR REFERENCES [1] D.W.O. Rogers, B. Walters, I. Kawrakow, BEAMnrcUser's. NRC Report PIRS 509, Canada, 2013 [2] B. Walters, I. Kawrakow and D.W.O. Rogers, DOSXYZnrc Users Manual. NRC Report PIRS 794, Canda,2013 [3] C.-M. Ma and D.W.O. Rogers, BEAMDP Users Manual, Ionizing Radiation Standards National Research Council of Canada, Ottawa Printed: April 1, 2013 [4] D.W.O. Rogers, B. Walters, I. Kawrakow, Beam Characterization a Multiple-source Model NRC Report,2013 [5] WORKING GROUP6: COMPUTATIONAL DOSIMETRY. Standard Monte Carlo Modeling of a Medical Linear Accelerator,2010 [6] Adel SAOUDI, Dépôt de dose dans les faisceaux de photons: simulations Monte Carlo GATE et EGSnrc. Comparaison avec des mesures expérimentales et la méthode Clarkson du logiciel IsoGray, http://pcsv.fr/sites/pcsv.fr/files/adel_rapport_version_finale.pdf (2010) [7] C. Guillerminet, (UTILISATION DU CODE BEAM EN RADIOTHERAPIE EXTERNE) http://sfrp.asso.fr/img/pdf/oral10.pdf [8] Besim Xhafa (Dose Distribution of Photon Beam by Siemens Linear Accelerator) http://dx.doi.org/10.4236/ijmpcero.2014.31011,(2014) [9] http://en.wikipedia.org/wiki/beamnrc, Friday, 2014 ISSN : 2028-9324 Vol. 6 No. 3, July 2014 641