Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Similar documents
Planned Preventative Maintenance Schedule. Raised Access Floor PPM Schedule

Data Centre Optimisation Services

APC by Schneider Electric Elite Data Centre Partner

Repeatable IT Hub Rooms

Industry leading low energy evaporative fresh air cooling.

Data Centre Solutions. Data Centre Solutions Expertly Engineered

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Rack Colocation Hosting. Data Centre Solutions Expertly Engineered

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Modular & Mobile Data Centre Solutions. Data Centre Solutions Expertly Engineered

1.0 Executive Summary. 2.0 Available Features & Benefits

Engineering & Support Services

1.0 Executive Summary

Case Study Leicester City Council

Thermal management. Thermal management

Repeatable IT Hub Rooms

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Data Centre Solutions Expertly Engineered APC Management Software

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Server Room & Data Centre Energy Efficiency. Technology Paper 003

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

How to Increase Data Center Efficiency

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Recapture Capacity for Existing. and Airflow Optimization

MEASURE MONITOR UNDERSTAND

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

survey, 71% of respondents listed Improving capacity planning as a top driver for buying DCIM 1.

Reducing Data Center Cooling Costs through Airflow Containment

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

Google s Green Data Centers: Network POP Case Study

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Data Centre Energy Efficiency. Duncan Clubb EMEA Data Centre Practice Director CS Technology

84 kw, Tier 3, Direct Expansion, 937 ft 2

Overcoming the Challenges of Server Virtualisation

MSYS 4480 AC Systems Winter 2015

Data Center Lifecycle and Energy Efficiency

Case Study Host Europe Group

Partner Introduction

Total Modular Data Centre Solutions

Rittal Cooling Solutions A. Tropp

Data Center Optimization Services. Maximize Your Data Center

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

1.0 Executive Summary. 2.0 Features and Benefits

18 th National Award for Excellence in Energy Management. July 27, 2017

CRITICAL INFRASTRUCTURE ASSESSMENTS

Case Study The University of Warwick

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Power and Cooling for Ultra-High Density Racks and Blade Servers

Switch to Perfection

1.1 ANNUAL DATA CENTER HEALTH CHECK

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

A Green Approach. Thermal

Green IT and Green DC

Rethinking Datacenter Cooling

Reducing Energy Consumption with

Optimizing Cooling Performance Of a Data Center

ENCLOSURE HEAT DISSIPATION

New Techniques for Energy-Efficient Data Center Cooling

Data Center Energy and Cost Saving Evaluation

Application of TileFlow to Improve Cooling in a Data Center

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

WIRELESS ENVIRONMENTAL MONITORS

IBM Site Enablement Services

Cannon T4 Modular Data Center (MDC)

Liebert DCW CATALOGUE

Data Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Server room guide helps energy managers reduce server consumption

Temperature monitoring and CFD Analysis of Data Centre

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

Effectiveness and Implementation of Modular Containment in Existing Data Centers

APC APPLICATION NOTE #74

EDX DC-3 environmental monitoring solution

INNOVATE DESIGN APPLY.

» BEST PRACTICES FOR AIRFLOW MANAGEMENT AND COOLING OPTIMISATION IN THE DATA CENTRE

INNOVATE DESIGN APPLY.

Rack & Enclosure Systems

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Review on Performance Metrics for Energy Efficiency in Data Center: The Role of Thermal Management

Data Center Infrastructure Management ( DCiM )

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

Power & Cooling Considerations for Virtualized Environments

LCP Hybrid Efficient performance with heat pipe technology

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Data Centre. Design and Build. Everything you need to know about designing, installing and maintaining a. Data Centre

Are all CFD s created equal? Prepared by: Associate Director: Sam Wicks

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

IBM Integrated Server Farm (ISF)

Optimiz Chilled January 25, 2013

Transcription:

Survey and Audit Service Schedule Airflow and Thermal Imaging Survey Service Schedule Data Centre Solutions Expertly Engineered

Consult optimisation, audit and survey services Data Centre Services Workspace Technology provides data centre operators unprecedented levels of expert help 24/7, anywhere in the UK. We deliver planned preventative maintenance and emergency callout on a wide range of AC, chilled water, UPS, generator, fire suppression and associated infrastructure. In order to complement onsite maintenance services Workspace Technology provides a range of assessments, surveys, audits and services specifically designed to help improve data centre performance and reduce operation costs for our clients. Airflow & Thermal Imaging Survey Workspace Technology s enhanced Airflow and Thermal Imaging Survey includes the following: n Room assessment and creation of data centre layout plan. n Thermal imaging photos of aisles and photographic images of individual equipment racks. n Air velocity pressure survey (airflow through each 600x600 vented floor tile). n Temperature and humidity check at low, medium and high levels on each equipment rack. n Flow & return temperature and humidity check on the air conditioning units. n Findings and recommendations report. Thermal Imaging Many data centre environments today are very high density; thermal imaging can identify problems before they become critical. The use of thermal photography of racks and aisles will help identify problems including hot spots, recirculation and hot and cold air mixing. Air Velocity Pressure Survey An understanding of air velocity will enable accurate identification of actual cold air flow rates within the cold aisles and its associated capacity throughout the room. The survey includes a full airflow meter reading of each vented floor tile, enabling mapping of the exact areas of air distribution in the data centre.

Temperature and Humidity Check Workspace Technology will undertake a survey of a low, medium, and high level temperature and humidity readings for each equipment rack. Workspace Technology will also undertake a flow and return temperature and humidity check on the Air Conditioning air handling units. Report Details A detailed report will be generated which will provide: n Assessment of the balance of air pressures and velocities from the floor plenum and observations drawn from these readings to show air starved areas. n Thermal images showing possible heating issues in the room. Hot spots are easily identifiable giving a clear indication of poorly cooled areas. n Recommendations to improve the efficiency of existing active kit through relocation. n Clear advice on the optimum location for additional servers. Benefits of Airflow and Thermal Imaging Survey n Knowledge of where the air is being delivered in the data room will help maximise the efficiency of future installations. n A baseline on the current airflow and how effective the current cooling is within the existing environment will help show how aisle containment and airflow management could improve the AC system efficiency, saving you money and reducing your carbon footprint. Airflow & Room Thermal Imaging Survey Schedule of Works Frequency Yearly (minimum recommended frequency). Item Service Detail 1 Identify aisles and racks which will form part of the survey scope of work. Measure and create detailed Data Centre floor plans. 2 Undertake thermal imaging of equipment aisles and associated equipment cabinets. 3 Undertake airflow survey of all raised access floor grille tiles within the survey area. 4 Measure low, medium and high level readings for all equipment rack inlet and outlet positions. 5 Produce detailed report including all readings with thermal images, detailed findings and associated recommendations.

Additional Data Centre Services Workspace Technology offers a range of data centre audit and survey services. These services may be specified as a result of a Data Centre Audit or as part of a comprehensive Data Centre planned preventative maintenance and support package. Service 3D Modelling and CFD Service Data Centre Audit Service Data Centre Optimisation Service Electrical Thermal Imaging Survey Power Quality Survey Power Usage Effectiveness (PUE) Assessment Details The 3D Data Centre Modelling and CFD service enable clients to visualise interactive 3D data centre models of existing or prospective data centre infrastructure. The Data Centre Audit will provide a comprehensive review of the existing data centre or server room facility designed to help identify both good and bad practice, help clients increase reliability, and deliver the best value by reducing total cost of ownership through reduced capital, operating and energy costs. The Data Centre Energy Optimisation Service will address data centre imbalances by fine tuning system settings and configuration arrangements to achieve improvements in energy efficiency and deliver maximum performance within ASHRAE recommended environmental operating range. The detailed Electrical Thermal Imaging Survey of data centre electrical systems and equipment will help identify unseen faults on electrical systems which can cause expensive business downtime, damage, loss of data or risk from fire. The Power Quality Survey provide customers with a clearly laid out summary of load, power factor and harmonic data findings. When quality issues are identified the report will include recommendations to correct problems. The implementation of survey recommendations will help customers reduce energy bills and can prolong life and prevent premature failure of equipment. The PUE Assessment enables IT and data centre managers to accurately benchmark the Power Usage Effectiveness (PUE), Data Centre Infrastructure Efficiency (DCiE) and usage of the server room environment through direct analysis of power and energy consumption. Further details on audit services can be found in individual audit and survey schedules.

Notes on Service Schedule All work mentioned in the schedule is carried out subject to Workspace Technology s Terms and Conditions of sale. The audit schedules shown are based on a standard and will not be applicable to every installation for every item listed. Consequently each task has to be qualified by the term; if it is safe so to do, if applicable, if possible and if appropriate. It is possible that your specific installation may have additional or specialised equipment not mentioned in this schedule. In that case, the specific equipment would be the subject of addenda to the main contract. Tasks mentioned in the schedule may also be omitted if Workspace Technology s engineers or its appointed agents deem that it is unsafe to carry out that task or that it may jeopardise the security of electrical supply. Workspace Technology Limited Unit 10, Reddicap Trading Estate, Sutton Coldfield, West Midlands, B75 7BU Tel : 0121 354 4894 Fax: 0121 354 6447 email: sales@workspace-technology.com www.workspace-technology.com www.workspace-technology.com