Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Similar documents
Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions. Speed monitor D / / 2014

Installation instructions Ethernet switch EC / / 2011

Hardware Manual RM CANview Gateway

Operating instructions IO-Link master CabinetLine AL19xx

Hardware Manual RM CANview

Operating instructions. Standstill monitor A / / 2011

Brief instructions Starter set BasicController BasicRelay BasicDisplay EC / / 2011

Operating instructions RFID evaluation unit DTE / / 2016

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GI712S

Operating instructions Optical distance sensor. OID20x / / 2014

Operating instructions Optical distance sensor. OID25x / / 2015

Hardware Manual RM Display 2501 S01..S04

Operating instructions. Monitor FD / / 2013

Hardware Manual RM Display 2401

USB-to-CAN V2. Compact Embedded Automotive Professional USER MANUAL ENGLISH

Hardware Manual RM Display 1001

Operating instructions Optical distance sensor. OID20x / / 2015

USB-to-CAN FD. Compact Embedded Automotive USER MANUAL ENGLISH

Operating instructions Optical distance sensor. O5D15x / / 2014

Operating instructions Evaluation system for flow sensors VS / / 2013

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Operating instructions Optical distance sensor. OID25x / / 2014

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Installation instructions Inclination sensor EC2019 EC / / 2013

CANbridge NT. 200 and 420 USER MANUAL EN 1.3

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016

EFX 3232m Installation Instructions

Serial PROFIBUS Interface

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Hardware Manual RM CANlink Bluetooth 2xxx

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Brief instructions Illumination unit O3M /00 09/2014

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

MC 11 EB-2 Power supply cabinet with external bus, AC version

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

USER S MANUAL TP1043 series

TVAC25100 TVAC25110 User manual

NT. 200 and 420 USER MANUAL EN 1.4

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

Type ME43. Quickstart

DIN Rail RTU 540CMD01 Data sheet

Kvaser USBcan Professional User's Guide

Kvaser Leaf Light v2 User s Guide

Kvaser USBcan Light User s Guide

CPCI-PS24 24V-Power Supply

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

FR-IB100/PCIe. FlexRay PCI Express Interface Card USER MANUAL ENGLISH

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

MINI MCR-SL-PT100-UI(-SP)(-NC)

DSU-BOX DSU dome converter TTY / RS422, housing version User manual

Kvaser PCIEcan 2xHS v2 User s Guide

Kvaser PCIEcan HS v2 User s Guide

MINI MCR-SL-CVS NC

USER MANUAL en-us ENGLISH

Operating instructions Optical distance sensor O1D / / 2012

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating instructions. Monitor FS-2 / FS-2N / / 2013

MINI MCR-SL-PT100-UI-200

Kvaser Leaf Light v2 User s Guide

MDM 011-Z1 Regen Resistor

PCAN-MicroMod Analog 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

DIS-2/M UTP DIS-2/M NSU DIS-2/M Multi-D HD

PCAN-MicroMod Analog 1 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Operating instructions. Monitor FR-1 / FR-1N / / 2013

II. Intelligent PC/CAN Interface USER MANUAL ENGLISH

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

ABB 520BID01 Binary Input datasheet

B63/ NS MS. EtherNet/IP LINK

* _1118* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Interface Adapter USM21A

Redundancy unit CP-A RU

Kvaser PCIEcan 4xHS User s Guide

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Kvaser BlackBird v2 User s Guide

User Manual HMI Linkbox HL01 DP/MPI

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Kvaser Leaf Light v2 User s Guide

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Kvaser Mini PCI Express HS v2 User s Guide

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Power Supply System KNX PS640-IP

Installation Instructions

Kvaser Mini PCI Express User s Guide

crio PN Installation Instructions V0.2/ COMSOFT

Binary output and supervision 520CSD01 Data sheet

IXXAT CME/PN. CANopen-PROFINET Gateway HARDWARE MANUAL ENGLISH

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Analog output 520AOD01 Data sheet

Transcription:

Content Content... 2 1. Preliminary note... 3 1.1. Symbols used... 3 1.2. Warning signs used... 3 2. Safety instructions... 4 2.1. General... 4 2.2. Target group... 4 2.3. Electrical connection... 4 2.4. Tampering with the device... 4 3. Functions and features... 5 3.1. Features at a glance... 5 3.2. Application example... 5 4. Installation... 6 5. Electrical connection... 6 5.1. General electrical connection... 6 5.2. More cables... 6 6. Display elements... 6 7. Set-up... 7 7.1. General notes... 7 7.2. Install esys-idc4e1 J2534-API driver... 7 8. Technical data... 10 9. Maintenance, repair and disposal... 14 9.1. Maintenance... 14 9.2. Cleaning the housing surface... 14 9.3. Repair... 14 9.4. Disposal... 14 10. Approvals/standards... 14 Sontheim Industrie Elektronik GmbH Page 2 of 15

1. Preliminary note This document applies to devices of the type esys-idc4e1 (art. no. V930230300) This document is intended for specialists. These specialists are people who are qualified by their appropriate training and their experience to see risks and to avoid possible hazards that may be caused during operation or maintenance of the device. The document contains information about the correct handling of the device. Read this document before use to familiarize yourself with operating conditions, installation and operation. Keep this document during the entire duration of use of the device. Adhere to the safety instructions. 1.1. Symbols used Instructions Reaction, result [ ] Designation of pushbuttons, buttons or indications Cross-reference Important note Non-compliance can result in malfunction or interference Information Information Supplementary note 1.2. Warning signs used WARNING CAUTION NOTE Warning of serious personal injury. Death or serious irreversible injuries may result. Warning of personal injury. Slight reversible injuries may result. Warning of damage to property. Sontheim Industrie Elektronik GmbH Page 3 of 15

2. Safety instructions 2.1. General These instructions contain texts and figures concerning the correct handling of the device and must be read before installation or use. Observe the operating instructions. Non-observance of the instructions, operation which is not in accordance with use as prescribed below, wrong installation or incorrect handling can seriously affect the safety of operators and machinery. 2.2. Target group These instructions are intended for authorized persons according to the EMC and low-voltage directives. The device must only be installed, connected and put into operation by a qualified electrician. 2.3. Electrical connection The connections may only be supplied with the signals indicated in the technical data and/or on the device label. 2.4. Tampering with the device In case of malfunctions or uncertainties please contact the manufacturer. Tampering with the device can seriously affect the safety of operators and machinery. It is not permitted and leads to the exclusion of any liability and warranty claims. Sontheim Industrie Elektronik GmbH Page 4 of 15

3. Functions and features esys-idc4e1 is a CAN-to-Ethernet Gateway with integrated diagnostic functions and allows the connection of different CAN busses over IP networks. Therefore the high performance CAN-to- Ethernet Gateway provides one LAN interface and four galvanically isolated CAN interfaces. 3.1. Features at a glance Operating voltage via phoenix connection (24 V DC) CAN interfaces galvanically isolated acc. to ISO 11898 standard CAN baud rate freely selectable Integrated error-frame-detection 3.2. Application example CAN System esys-idc4e1 PC or Notebook Sontheim Industrie Elektronik GmbH Page 5 of 15

4. Installation The device is operated without installation. 5. Electrical connection 5.1. General electrical connection Wiring 8 technical data The connection of the device to the CAN system is made over a SubD9 plug compliant to CiA, CAN ISO 11898. 5.2. More cables Information about available CAN cables at: Phone: +498315759000 mail: info@s-i-e.de 6. Display elements Status LED Operating states 8 technical data Sontheim Industrie Elektronik GmbH Page 6 of 15

7. Set-up 7.1. General notes The software required for set-up and use of the device is on the SiE-System-DVD. 7.2. Install esys-idc4e1 J2534-API driver Make sure that you log in with administrator privileges Put the System CD into the computer drive The navigation window opens Start J2534-Setup.exe The installation wizard opens An interface description of the J2534-API is also included on the System- CD Continue the installation process with [Next] Sontheim Industrie Elektronik GmbH Page 7 of 15

Accept the license agreement and continue the installation with [Next] Select a folder to install The J2534 API will be installed Old J2534-API versions are replaced by newer versions! Sontheim Industrie Elektronik GmbH Page 8 of 15

Continue the installation with [next]. Continue the installation with [Finish] and agree with [Reboot now] a Windows restart and complete the installation. PC / notebook is restarted Sontheim Industrie Elektronik GmbH Page 9 of 15

8. Technical data esys-idc4e1 V930230300 CAN-to-Ethernet Gateway for the connection of different CAN busses over IP networks (incl. diagnostic functions & CAN-to-CAN Bridging) Operating voltage 24 V DC esys-idc4e1 Technical Data Housing Solid aluminum Dimensions (W x H x D ca. 121 x 151 x 48 mm Protection rating IP30 Weight ca. 568g CAN interface 4x gal. isolated acc. to CiA, CAN ISO 11898-2, 2.0A and 2.0B Baud rate 50 kbit up to 1 MBit/sec (incl. 800kBit/s), free configuration CAN - resistance measurement CAN bus resistance measurement of the machine. Measurement on active bus LAN 100 Mbit LAN, RJ45 connection LEDs LAN status LED, green and yellow at RJ45 connection Power supply 24V +/- 10% / max. 1A Microcontroller Freescale Power PC RAM 32MB (optional up to 128MB) Flash 16MB (optional up to 128MB) Operating temperature 0 C up to +60 C Storage temperature -20 C up to +70 C Additional information Usable as a CAN-to-CAN Bridge System requirements Microsoft Windows, XP (starting from SP3), Vista or Windows 7, 8 Sontheim Industrie Elektronik GmbH Page 10 of 15

esys-idc4e1 CE-marking Cabel CAN & LAN Technische Daten EN 61000-6-2 electromagnetic compliance (EMC) interference immunity (10 V/m) EN 61000-6-4 electromagnetic compliance (EMC) electromagnetic interference EN 61000-4-2 electrostatic discharge (ESD) EN 61000-4-3 Immunity to radiated electromagnetic fields EN 61000-4-4 Immunity to electrical fast transient EN 61000-4-5 surge immunity EN 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields without any cabel (for any inquiry please contact our support under +49 831 575 900 0 or info@s-i-e.de Operating status LED LED-colour Status Description LAN green on off LAN-connection activ LAN-connection inactiv orange on off LAN-communication activ LAN- communication inactiv Pin assignments CAN 1-2 CAN-Low 3 GND (Ground) 4-5 - 6-7 CAN-High 8-9 - Sontheim Industrie Elektronik GmbH Page 11 of 15

LAN-RJ45 1 Tx+ 2 Tx- 3 Rx+ 4 NC 5 NC 6 Rx- 7 NC 8 NC Dip-switch CAN resistance measurement 1 120Ω CAN1 An/Aus 2 120Ω CAN2 An/Aus 3 120Ω CAN3 An/Aus 4 120Ω CAN4 An/Aus Power supply 1 24V 2 0V 3 PE Features Error Frame detection Resistance measurement LEDs Integrated Integrated 1x LAN Data 1x LAN Status Sontheim Industrie Elektronik GmbH Page 12 of 15

Block diagram Items delivered 1x 1x esys-idc4e1 1 x System-CD with drivers J2534 API incl. software description, technical description Sontheim Industrie Elektronik GmbH Page 13 of 15

9. Maintenance, repair and disposal 9.1. Maintenance The device does not contain any components that need to be maintained by the user. 9.2. Cleaning the housing surface Disconnect the device. Clean the device from dust and light dirt using a soft, chemically untreated, dry cloth. In case of heavy dirt use a damp soft clean cloth. The following agents are not suited for cleaning the device: chemicals dissolving plastics such as methylated spirit, benzine, thinner, alcohol, acetone or ammonia. Micro-fibre cloths without chemical additives are recommended. 9.3. Repair The device must only be repaired by the manufacturer. Observe the safety instructions ( 2.4 Tampering with the device) 9.4. Disposal Dispose of the device in accordance with the national environmental regulations. 10. Approvals/standards Test standards and regulations ( 8 Technical data) Sontheim Industrie Elektronik GmbH Page 14 of 15