IT optimization White paper May Optimize energy use for the data center through enhanced measurement and management

Similar documents
RF Code Delivers Millions of Dollars in Annual Power & Cooling Savings for CenturyLink

The case for cloud-based data backup

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Cloud-based data backup: a buyer s guide

Energy Action Plan 2015

IBM Power Systems Express Servers

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

Build a viable plan for disaster recovery and crisis management.

Oracle Buys Automated Applications Controls Leader LogicalApps

EDX DC-3 environmental monitoring solution

IBM Storwize V5000 disk system

Virtualizing disaster recovery helps ensure business resiliency while cutting operating costs.

IBM System Storage DS5020 Express

IBM Tivoli Network Manager Entry Edition

Overview. Business value

2007 Power Symposium Where are we going?

IBM Internet Security Systems Proventia Management SiteProtector

WHITE PAPER. How VMware Virtualization Right-sizes IT Infrastructure to Reduce Power Consumption

How Microsoft IT Reduced Operating Expenses Using Virtualization

Deliver robust products at reduced cost by linking model-driven software testing to quality management.

Grow Your Services Business

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

Data Center Infrastructure Management (DCIM) Demystified

Environmental & Efficiency Trends in Enterprise Computing. John Sheehy Systems Architect

Data Center Infrastructure Management (D.C.I.M.)

Tulane University. Reducing energy waste. Smart is...

Cisco EnergyWise Optimize and Cost Saving. Traditional IT Power Management

CA ecometer. Overview. Benefits. agility made possible. Improve data center uptime and availability through better energy management

Best-practice strategies for designing and deploying modular data centers

Accelerate Your Enterprise Private Cloud Initiative

Green IT: Green Services are Good for Business, Providing Energy Savings and Environmental Benefits

Green IT: reduce energy costs and improve service levels with virtualization Bob Good, Manager - Systems Engineers August 2009 MISA Fall Conference

IBM System Storage DS5020 Express

Data management for. smarter business outcomes

OPENING THE DOOR TO THE SMART CITY KEY PRIORITIES AND PROVEN BEST PRACTICES FROM MAJOR CITIES WORLDWIDE

Verizon Perspectives on Smart Infrastructure. Anthony J. (Tony) DiMaso Advanced Energy Conference November 19, 2009

Everyday Security: Simple Solutions to Complex Security Problems

IBM 42U and 47U 1200mm Deep Static and 42U 1200mm Deep Dynamic Racks for System x

HPE Energy Efficiency Certification Service

IBM Storwize V7000: For your VMware virtual infrastructure

Reaping the Benefits of Managed Services

IBM Tivoli OMEGAMON XE on z/os

DATA CENTER AIR HANDLING COOLING SOLUTIONS

IBM Systems Director Active Energy Manager for x86 V3.1 enables systems platform management and monitoring across IBM System x servers

Energy Solutions for Buildings

Moving From Reactive to Proactive Storage Management with an On-demand Cloud Solution

IBM Real-time Compression and ProtecTIER Deduplication

W H I T E P A P E R S e r v e r R e f r e s h t o M e e t t h e C h a n g i n g N e e d s o f I T?

IBM Tivoli Directory Server

Comprehensive Data Center Energy Management Solutions

IBM PowerVM. Virtualization without limits. Highlights. IBM Systems and Technology Data Sheet

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

New Zealand Government IbM Infrastructure as a service

New Zealand Government IBM Infrastructure as a Service

Reducing Costs in the Data Center Comparing Costs and Benefits of Leading Data Protection Technologies

1.0 Executive Summary

Continuous Diagnostics and Mitigation demands, CyberScope and beyond

FIS Global Partners with Asigra To Provide Financial Services Clients with Enhanced Secure Data Protection that Meets Compliance Mandates

HPC Solutions in High Density Data Centers

IBM TS7700 grid solutions for business continuity

APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS

HP environmental messaging

WHITE PAPER ULTRA LOW LATENCY MICROWAVE THE NEED FOR SPEED: BEST PRACTICES FOR BUILDING ULTRA-LOW LATENCY MICROWAVE NETWORKS

Green IT and Green DC

Decommissioning Legacy Networks

IBM Global Technology Services. Weathering the storm: IT challenges and opportunities amidst economic uncertainty

WHITE PAPER: ENTERPRISE AVAILABILITY. Introduction to Adaptive Instrumentation with Symantec Indepth for J2EE Application Performance Management

Annual Report for the Utility Savings Initiative

IBM Z servers running Oracle Database 12c on Linux

Powering Performance. Enhance business value and efficiency. Proposition series September 2017

Data Centre Solutions Expertly Engineered APC Management Software

Decommissioning Legacy Networks

UNIX Server Optimization With TCO and ROI Analysis

IBM Storage Software Strategy

Cisco Start. IT solutions designed to propel your business

IBM System Storage DS4800

IBM Tivoli Monitoring (ITM) And AIX. Andre Metelo IBM SWG Competitive Project Office

Overcoming the Challenges of Server Virtualisation

IBM Global Technology Services White Paper. Driving enterprise resiliency with data center consolidation and migration

Stellar performance for a virtualized world

SOLUTION BRIEF RSA ARCHER IT & SECURITY RISK MANAGEMENT

for Power Energy and

FACILITY SERVICES UILDINBUILDG

Committed to Energy Efficiency

Smart Data Center From Hitachi Vantara: Transform to an Agile, Learning Data Center

Power & Cooling Considerations for Virtualized Environments

HP StorageWorks LTO-5 Ultrium tape portfolio

Raytheon s Strategic IT Energy and Resource Management Program

COLUMBUS. Business Solutions. Cloud Unified Communications & Interoperability. Javier Pereira Director of Product Development November 2011

Building Management Solutions. for Data Centers and Mission Critical Facilities

SIX Trends in our World

Measurement and Management Technologies (MMT)

5 STEPS for Turning Data into Actionable Insights

Australian Open takes tennis to millions of online viewers worldwide with IBM

Environmental Sustainability

Virtualizing the SAP Infrastructure through Grid Technology. WHITE PAPER March 2007

Energy Performance Contracting

34% DOING MORE WITH LESS How Red Hat Enterprise Linux shrinks total cost of ownership (TCO) compared to Windows. I n a study measuring

siemens.com/dcim We are the trusted technology partner for energy-efficient, safe and secure buildings and infrastructure.

M E M O R A N D U M. To: California State Lottery Commission Date: October 16, Item 9(c): Approval to Hire Project Management Consultant

Transcription:

IT optimization White paper May 2008 Optimize energy use for the data center through enhanced measurement and management

Table of Contents 3 Overview Recognize the critical need for energy-efficient data centers 5 Understand the requirements of an effective measurement and management solution 6 Explore integrated solutions to support the energy-efficient data center 9 14 Conclusion 16 For more information

Overview Today s organizations face an urgent need to develop energy-efficient and environmentally responsible data centers. Data centers are growing at a tremendous rate, but energy costs are becoming a proportionally higher part of their operational budget. Analysts estimate that within a few years, the cost of powering and cooling a server will equal its purchase price 1. Unfortunately, IT management often lacks sufficient visibility into the details of energy costs and inefficiencies, so it is unable to take proper steps to lower consumption, streamline operations, make better use of assets it already has and resolve other energy-related requirements. To address these critical issues, today s IT organizations need a comprehensive yet tightly integrated energy management solution that encompasses both IT and physical facilities. A properly designed and implemented energy management solution delivers the ability to view system utilization rates, generate energy alerts, monitor energy trends, measure energy use data and cap system power use. It should also manage data center facility assets such as air conditioning, electricity and floor space in conjunction with IT to optimize the entire data center environment for energy efficiency. The result can be a significant savings in energy costs, as well as the opportunity to show leadership in promoting innovative ways to increase energy efficiency. Along with an in-depth discussion of energy measurement and management, this white paper provides a brief overview of IBM solutions that can help organizations support their initiatives for developing energy-efficient and environmentally responsible data centers. 3

Estimated savings from improvements in energy efficiency The EPA Report to Congress on Server and Data Center Efficiency estimates that the improved operational management [of IT equipment] offers potential electricity savings of more than 20% 3. Based on this scenario, a typical 25,000-square-foot data center that spends $2.6 million in power annually has potential savings of more than 4 million kwh. This reduction would have the equivalency results of: An abatement of 3,714 metric tons of CO2 annually. Annual greenhouse gas emissions of 617 passenger vehicles. Carbon sequestered by 86,325 tree seedlings grown for 10 years. A potential savings of $1.2M in energy costs over four years (assuming a 5% per year improvement over that period). From 1996 to 2008, the costs to power, cool and manage data centers have more than doubled. Analysts expect this trend to continue in the future 2. 4

Recognize the critical need for energy-efficient data centers Today s data centers are at a tipping point. Data center floor space capacity is growing by approximately 10 percent per year for large enterprises, and the amount of energy that these data centers consume continues to soar. Typically, a data center consumes 10 to 100 times more energy per square foot than the average office building. At current rates, these power requirements could double in five years 4. In fact, IT is becoming the largest single component of many firms energy costs often 30 to 40 percent of the entire energy budget 5. Current trends suggest that within a few years, the cost to power and cool servers will actually equal new server acquisition costs. Even now, each dollar of new servers results in a cost of $0.52 for power and cooling. This cost is expected to increase 37 percent over the next four years to $0.71 6. 5

Understand the requirements of an effective measurement and management solution Energy efficiency in the data center depends on being able to clearly measure, monitor and manage energy consumption. This includes having hardware and software work hand-in-hand to address power surges, hot spots in facilities, wasted energy, overheating and overuse of power by applications, air conditioning and other categories. Monitoring solutions should also collect energy data from across the enterprise and work closely with solutions that track facilities, business priorities and policies. In addition, data center space is saved if IT assets such as servers are used more efficiently, thereby reducing the need to add more servers while making better use of those already in place. Equally important, this energy data must be integrated across the enterprise and at multiple levels, on both the IT and the business sides of the organization, thereby managing energy in the context of business requirements. This way, IT managers can reduce system power but not business performance. In fact, organizations need an integrated system that enables users to set up policies that will automatically increase or decrease power consumption while still guaranteeing fulfillment of the business service level agreements (SLAs). 6

Accordingly, an effective energy measurement and management solution should be able to: Integrate information across the infrastructure, including IT and physical facilities. System administrators should have a consolidated view of power, temperature and application performance metrics in the data center. Flexibly manage power on servers or groups of servers either manually or automatically according to a defined policy. Administrators need to monitor and manage facilities (such as air conditioning, power and equipment) in conjunction with IT to increase energy efficiency and reduce power use and cost. Enable administrators to view system utilization rates to make sure that IT assets are being used efficiently before new systems are added to the data center, thereby making the best use of existing systems, space, power and air conditioning. Manage processor resources and power consumption to achieve applicationresponse times and SLAs with minimum energy use and cost. Determine the proper power allocation for each server and help reallocate power to additional servers without additional power or cooling equipment. Care should be taken that limiting power consumption does not degrade performance. Provide operational management tools to incorporate a business and financial perspective. This includes the management of the IT asset life cycle to manage server assets so that older, less energy-efficient servers are replaced with newer, more energy-efficient ones when the time is right. 7

Capture, analyze and display assets, locations and work orders through geographic information system (GIS) modeling and mapping software. Feed energy-use information into chargeback applications, enabling business units to accurately understand who is using what and hold users accountable. They can also see which organizations are causing large amounts of power to be consumed while at the same time generating reports that show where opportunities for energy savings exist. IBM provides an integrated approach across the entire energy spectrum to address client concerns. 8

Free 60-day trial A no-charge, 60-day trial version of IBM Systems Director Active Energy Manager is available online. Visit ibm.com/systems/ greendatacenter to download this offer and test-drive IBM Systems Director Active Energy Manager today. Explore integrated solutions to support the energyefficient data center Although going green will remain an important challenge for IT in the years ahead, the good news is that green strategies and technologies exist today to help data centers optimize space, power, cooling and resiliency all while improving operational management, reducing costs and supporting business growth. IBM Systems Director Active Energy Manager measures, monitors and manages the energy management components built into IBM systems while enabling a cross-platform management solution. Active Energy Manager offers a single view of actual power use across multiple platforms in the infrastructure, as opposed to published system-energy-label specifications for power consumption. In addition, Active Energy Manager enables IT managers to cap power use at a system level. This is an important capability for organizations that have signed agreements with their utility companies to restrict their utilization of power to certain thresholds. If they exceed those thresholds, then they have to pay a premium. With Active Energy Manager, these organizations can choose to trade-off power consumption for performance in a controlled way, according to service level policies, so they can stabilize power use. In an outage, Active Energy Manager can throttle back systems to reduce consumption and better maintain power costs. 9

Active Energy Manager is an application that runs as an extension to IBM Systems Director and employs agent-less technology to communicate directly (natively) with systems that are being managed and monitored by the application. IBM Systems Director is not required on every system that is managed by Active Energy Manager since agents do not need be installed on the end-point systems. Active Energy Manager does not require an additional management server because it can run on the server that it is managing while also serving as a single control point for other systems that are being managed. In addition, Active Energy Manager supports energy monitoring of devices that are connected to select Power Distribution Units (PDU), or smart power strips used to provide power to multiple devices. By plugging systems into a PDU, Active Energy Manager can collect energy information from equipment in the rack that is plugged into the PDU, including I/O drawers, storage devices and servers. Using PDUs, Active Energy Manager can monitor both IBM and non-ibm servers that do not have native support, thus providing a broader view of energy use within the IT data center. In the event that PDUs are not a viable alternative, Active Energy Manager can retrieve temperature and power information using the facility provider s wireless sensors, which can be located virtually anywhere in the data center. This allows monitoring of older IBM servers and non-ibm servers without installing new PDUs. 10

IBM services for the data center IBM provides a range of integrated, proven service solutions for the data center to help IT organizations reduce energy consumption, contain costs, maintain performance and support business objectives: IBM Systems Director Active Energy Manager Implementation Jumpstart is an implementation and hands-on training service that assists organizations in exploiting the capabilities of IBM Systems Director Active Energy Manager and IBM Systems Director on IBM systems, IBM BladeCenter and IBM System Storage environments. This service can optionally include discussions and guidance on how to integrate Active Energy Manager Extensions with Tivoli Enterprise Management software using IBM Tivoli Monitoring Power Agent and/or OEM equipment such as building and facility automation systems. The scope of the Active Energy Manager also extends beyond systems because it can receive alerts and events related to power and cooling equipment. Interaction with facility providers reveals these events. As one example, alerts can notify IT administrators about issues with facilities equipment. Administrators can then use this information to determine if servers are in danger of overheating, if an uninterruptible power supply (UPS) battery is running low or if any other conditions may keep IT equipment in a data center from running properly. As an integrated part of the IBM Systems Director family, Active Energy Manager provides a source of energy management data that can be fully exploited by IBM Tivoli enterprise solutions for large-scale, enterprise-wide power management, facilities management, asset management and usage reporting. Tivoli software delivers a complete solution for managing energy efficiency. Monitoring capabilities from Tivoli software allow an administrator to view and manage application response times to minimize power consumption while still achieving SLAs. IT managers can set policies in monitoring solutions that indicate when a server s power consumption should be reduced and when it should be increased. These policies can be as simple as reducing power on weekends or automating adjustments based on response-time requirements. 11

IBM services for the data center IBM Data Center and Facilities Strategy Services are designed to streamline the data center planning and management process, helping organizations determine their data center facility capacity, availability and security requirements. These services also help organizations identify suitable locations for facilities and evaluate the best way to acquire, operate and manage the data center. For example, if an SLA requires a response time of two seconds or less, an IT manager can set a policy indicating that if the response time is less than one second, power consumption is reduced for the server. When the response time reaches 1.5 seconds, power consumption is increased for the server. Once defined and integrated into power operations, these policies require no manual intervention to execute. Monitoring capabilities from Tivoli software can also be used to set thresholds and drive automated actions based on events such as overheating of a system. This data can be shared through power and thermal information reports. Tivoli solutions for facilities management allow asset managers to visualize the spatial relationships among managed assets and other mapped features across IT, data center infrastructure and building automation systems such as fire alarms, lighting, heating, ventilation, air conditioning (HVAC) and so forth. This capability can help bring energy data together from multiple systems instead of being distributed across different environments, thereby helping to improve work planning and analysis, eliminate the need for data duplication, create efficiencies in business processes and enhance communication. Embedded GIS functionality provides seamless access to dynamic GIS functionality, instead of just views of a static map. 12

IBM services for the data center IBM Global Asset Recovery Services provide IT asset disposal options to help organizations safely and securely dispose retired IT hardware in an environmentally friendly way and invest in refurbished, warrantybacked equipment. IBM Global Financing Services provide hardware, software and services financing to help stretch budgets and make investments in measuring and managing energy even more affordable. Tivoli asset management solutions help customers manage their IT assets from a financial standpoint, using a single solution that tracks and manages hardware, software and related information throughout their life cycles. Designed to support both IT and enterprise assets, these solutions can significantly reduce IT asset cost by helping customers decide when a mature, energy-inefficient IT asset should be replaced with a new, more energy-efficient model. Underutilized assets can be redeployed and software overlicensing can be avoided. Tivoli usage and accounting solutions can be used to feed energy-use information into reporting and chargeback (financial accounting) applications, encouraging additional energy efficiencies through a better understanding by corporate users of actual energy consumption, including who caused that energy to be consumed. IT managers can accurately track, allocate and invoice by a number of criteria such as department, business unit or even by customer in situations where an application has been outsourced. Designed for ease of use and efficient management, the solutions deliver detailed information and reports while masking the underlying complexity of shared resource use. Tivoli also has additional offerings in its portfolio to increase energy efficiency throughout an enterprise. The capabilities mentioned above represent only an example of the benefits that Tivoli software offers to clients who want to measure and manage energy more efficiently and effectively today. 13

Conclusion Data centers with the tools to measure and manage energy consumption are well positioned to use less energy, generate less CO2, make better use of existing IT assets, take up less space and provide significant cost savings. Based on more than 50 years of success in developing data centers around the world, IBM solutions for energy-efficient data centers can help organizations: Monitor server utilization rates and energy consumption for greater energy efficiency: Enable IT to use less energy while still supporting business priorities and achieving application response-time targets and SLAs. Track who used what, and obtain reports showing which internal users are responsible for the greatest use of IT assets and power consumption. Bill either to internal users or to external customers, encouraging reduced IT and energy use. Measure power draw by actual use, not published system-energy-label specifications. 14

Manage IT assets from a financial perspective: Decide when to replace older, less energy-efficient systems with newer, more energy-efficient ones to help save costs. Understand the exact power and cooling costs in a data center from a facilities perspective, as well as the breakdown of costs per component. Cap power at the server levels, helping to remain within corporate use policies or negotiated rates from energy providers. Save energy costs in periods of low utilization by throttling down servers and balancing server loads. Combine hardware, system logic and group management tools. Ensure data center robustness within a fixed power envelope. Increase performance without increasing infrastructure. Strike the optimal balance between business needs and environmental concerns. IBM also provides a powerful range of integrated service solutions (see sidebar) to help organizations with their data center initiatives. IBM services include financing, planning, designing, building and testing for new data centers, as well as training for IT staff about how to best maintain the new environment. 15

For more information To learn more about IBM solutions for developing an energyefficient and environmentally responsible data center, contact your IBM representative or IBM Business Partner, or visit ibm.com/systems/greendatacenter 1 IDC, Worldwide Server Power and Cooling Expense 2006-2010, Document #203598, September 2006. 2 Worldwide Server Power and Cooling Expense 2006-2010. 3 U.S. Environmental Protection Agency, Report to Congress on Server and Data Center Efficiency, August 2, 2007, page 10. www.energystar.gov/ia/partners/ prod_development/downloads/epa_datacenter_report_congress_final1.pdf 4 U.S. Department of Energy, Creating Energy-Efficient Data Centers, May 18, 2007. 5 IBM study, IT energy efficiency for small and midsize businesses: Good for business and the environment, November 2007. 6 Worldwide Server Power and Cooling Expense 2006-2010. Copyright IBM Corporation 2008 IBM Global Services Route 100 Somers, NY 10589 U.S.A. Produced in the United States of America May 2008 IBM, the IBM logo, ibm.com, BladeCenter, IBM Systems Director Active Energy Manager, System Storage and Tivoli are trademarks of International Business Machines Corporation in the United States, other countries or both. Other company, product and service names may be trademarks or service marks of others. Disclaimer: The customer is responsible for ensuring compliance with legal requirements. It is the customer s sole responsibility to obtain advice of competent legal counsel as to the identification and interpretation of any relevant laws and regulatory requirements that may affect the customer s business and any actions the reader may have to take to comply with such laws. IBM does not provide legal advice or represent or warrant that its services or products will ensure that the customer is in compliance with any law or regulation. OIW03012-USEN-00