Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Similar documents
NJ-Series Power Supply Unit NJ-PA/PD

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

Features various encoder interfaces and controls multiple analog servo drives at high speeds

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

NX-TS. NX-series Temperature Input Unit

S82S (3/7.5-W Models)

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

NJ NJ-series NJ501 SECS/GEM CPU Unit. Allows SECS/GEM communications in a short time with a simple configuration. Feature

Solid State Relays with Failure Detection Function

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

CSM_PYF S/P2RF- -S_DS_E_2_5

Model A7BS

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Connecting Sockets, Mounting Brackets, DIN Rails

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

Number of input channels

NX-DA CSM_NX-DA_DS_E_3_1

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Model Number Structure

Electroformed Probe Pins XP3A

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Indicator (Square) Ultra Bright LED Type

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

CJ1W-DRM21 CSM_CJ1W-DRM21_DS_E_8_5

E4C-UDA CSM_E4C-UDA_DS_E_12_2

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

Sub-trunk line Terminating Resistance Repeater Unit. Branch Line Repeater Unit. Sub-trunk line. Terminating Resistance.

CSM_NX-PG0 DS_E_4_4

Indicator (Square) Ultra Bright LED Type

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

CX-One Ver.4 CSM_CX-One_DS_E_10_2

CX-One Ver.4 CSM_CX-One_DS_E_8_2

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

Model NPN output PNP output Standard. configuration

Dimension A. Dimension B

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

CX-Designer Ver.3 CSM_CX-Designer_DS_E_5_5

CJ1W-CRM21 CSM_CJ1W-CRM21_DS_E_11_4

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

NYM CSM_NYM_DS_E_2_2. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

NJ-series Machine Automation Controller SECS/GEM CPU Unit NJ

Model Number Structure

Model Number Structure

Practices Guide OMRON Standard IAG Library

M16-J M16-A M16-T

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

CJ1W-FLN22 CSM_CJ1W-FLN22_DS_E_3_1

CX-Integrator Ver.2 CSM_CX-Integrator_Ver2_DS_E_6_5

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information

Model Number Structure

Knob-type Selector Switches

NYM. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

CSM_NX-HAD DS_E_DITA_2_1

CJ series Position Control Units. High-speed, High-precision positioning with 1, 2, or 4 axes. Features. System Configuration

EtherCAT master * Output port CPU Unit

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

Model Number Structure

NPN output. 200 mm. Type Cable length Model Remarks

SYSMAC CS-series MECHATROLINK-II-compatible Position Control Units

Classification Applicable models Specification Type Model

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Smart Sensors with Ultra-High-Speed Color CCD Cameras mm to mm (variable) mm to mm (variable)

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Reuse Terminal Block Wiring When Replacing PLCs. Terminal Block Conversion Adapters. Overview. Features. System Configuration

Analog Input Unit. MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

Machine Automation Controller NJ Series

CMOS Laser Sensor with Built-in Amplifier ZX0

CX-Simulator Ver.1 CSM_CX-Simulator_Ver1_DS_E_7_5

With operation indicators **LY2N-CR **LY2ZN-CR

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

E2K-X4ME1 2M E2K-X4ME2 2M

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Transcription:

NX-Series Power Supply Unit CSM_NX-PA_PD_DS_E_2_2 Powerful power supply unit to supply stable power to the NX-series controller. Stable power supply is available from the NX-series CPU Unit to each I/O Unit via the dedicated bus. Lineups are provided for AC input types with 90 W output and DC input types with 70 W output. NX-PD7001 Features AC input types with 90 W output or DC input types with 70 W output allows power supply to large-scale configurations. Operating output contact indicates the CPU operation status (available in all models). Ordering Information International Standards The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: culus, UC1: culus (Class I Division 2 Products for Hazardous Locations), CU: cul, N: NK, L: Lloyd, CE: EC Directives, C-Tick: C-Tick mark, and KC: KC Registration. Contact your OMRON representative for further details and applicable conditions for these standards. Power Supply Units Product Name Power supply voltage Output capacity Total power consumption 24-VDC service power supply Options RUN output Maintenance forecast monitor Model Standards AC Power Supply Unit DC Power Supply Unit 100 to 240 VAC 90 W No Yes No NX-PA9001 24 VDC 70 W NX-PD7001 UC1, N, L, CE, RCM, KC Accessories There is no accessory for the NX-series Power Supply Unit. Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. 1

General Specification Item Specifications Model NX-PA9001 NX-PD7001 Dimensions 80 100 100 mm (W H D) Weight 570 g 290 g 51 100 100 mm (W H D) Power supply voltage 100 to 240 VAC (wide-range), 50/60 Hz (85 to 264 VAC, 47 to 63 Hz) 24 VDC (20.4 to 28.8 VDC) Power consumption 150 VA max. 85 W max. Inrush current *1 At 100 VAC: 20 A *2/8 ms max. for cold start at room temperature At 200 VAC: 40 A *2/8 ms max. for cold start at room temperature Output capacity *4 Total: 90 W max. Total: 70 W max. Output terminal (service supply) Not provided. RUN Output Contact configuration: SPST-NO Switch capacity: 250 VAC, 2 A (resistive load) 120 VAC, 0.5 A (inductive load), 24 VDC, 2A (resistive load) Replacement notification function Not provided. Insulation resistance 20 MΩ min. (at 500 VDC) between AC external and GR terminals *5 2,300 VAC 50/60 Hz for 1 min between AC Dielectric strength external and GR terminals *5 *7 Leakage current: 5 ma max. At 24 VDC: 30 A/2 ms max. for cold start at room temperature 7 A *3/3 s max. for cold start at room temperature *1. The inrush current may vary depending on the operating condition and other conditions. Therefore, select fuses, breakers, and external power supply devices that have enough margin in characteristic and capacity, considering the condition under which the devices are used. *2. If the ambient temperature is higher or the Controller is hot-started, the inrush current given in the table may be exceeded by up to twice the given value because the thermistor element with a low-temperature current control characteristic is not sufficiently cool. *3. Of the inrush current values, the latter value varies depending on the input voltage and may rise to approx. 8.3 A at 20.4 VDC. *4. Internal components in the Power Supply Unit will deteriorate or be damaged if the Power Supply Unit is used for an extended period of time exceeding the power supply output capacity or if the outputs are shorted. *5. Apply the voltage between the Power Supply Unit s L1 or L2 terminal and the GR terminal when testing insulation and dielectric strength. The tests can also be performed with the LG terminal and GR terminal connected to each other. In this case, the leakage current will be 10 ma or less. *6. The primary DC power supply and the secondary DC power supply are not isolated. *7. Change the applied voltage gradually using the adjuster on the Tester. If the full dielectric strength voltage is applied or turned OFF using the switch on the Tester, the generated impulse voltage may damage the Power Supply Unit. --- *6 --- *6 2

External Interface NX-PA9001 POWER Indicator (PWR LED) AC input L1 AC input L2 LG GR L1 AC100-2 INPUT L2/N L1 L2/N Connector RUN output RUN OUTPUT AC240V DC24V NX-PD7001 POWER Indicator (PWR LED) Connector DC input + DC input - LG GR + DC24V INPUT RUN output RUN OUTPUT AC240V DC24V AC Input Supply 100 to 240 VAC (allowable: 85 to 264 VAC). The NX-PA9001 has a wide input range, so it does not have voltage switching terminals. DC Input Supply 24 VDC (allowable: 20.4 to 28.8 VDC.) LG Ground to a resistance of 100 Ω or less to increase noise resistance and avoid electric shock. GR Ground to a resistance of 100 Ω or less to avoid electric shock. RUN Output The internal contacts for the RUN output turn ON when the CPU Unit is in RUN status. 3

Wiring About Power Supply For AC/DC power supply Recommended wire diameter AWG 14 to 20 (Cross section 0.517 to 2.08 mm 2 ) For grounding wire Recommended wire diameter 2 mm 2 or thicker Crimp Terminals The terminals on the Power Supply Unit are M4, self-raising terminals with screws. Crimp Terminals for AC Power Supplies 7 mm max. Crimp Terminals for DC Power Supplies 7 mm max. 7 mm max. Crimp terminal for the grounding wire 7 mm max. 7 mm max. Precautions for Use Compatible CPU Models NX-PA9001/NX-PD7001 are dedicated for NX-series. 4

Dimensions NX-PA9001 (Unit: mm) 4.5 PWR 100 2.3 80 100 NX-PD7001 4.5 PWR 100 2.3 51 100 Related Manuals Manual name Cat. No. Model numbers Application Description NX-series CPU Unit Hardware User s Manual W535 NX701-@@@@ Learning the basic specifications of the NXseries CPU Units, including introductory information, designing, installation, and maintenance. Mainly hardware information is provided. An introduction to the entire NX-series system is provided along with the following information on a Controller built with a CPU Unit. Features and system configuration Introduction Part names and functions General specifications Installation and wiring Maintenance and inspection Use this manual together with the NJ/NX-series CPU Unit Software User s Manual (Cat. No. W501). 5

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2017.10 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2017 All Right Reserved.