DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Similar documents
DIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Serie REX-D. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series PAXD. Key-Features:

DIGITAL ANZEIGE. for Industry Applications. Series PAXP, PAXDP. Key-Features:

LASER SENSOR. Series LAS-T5 and LAS-T. Key-Features:

LASER. Laser Displacement Sensor. Series LLD-500. Key-Features:

LASER. Laser Displacement Sensor. Series LLD-500. Key-Features:

AX 345 and AX 347 Process Indicators with Two Analogue Inputs and Calculations

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features:

MAGNETOSTRICTIVE TRANSDUCER

ENCODER. Profibus Multiturn. Series , Key-Features:

DX 345, DX 346, DX 347, DX 348

ULTRASONIC. Distance and Proximity Sensors. UFP / UPA Series. Key-Features:

Process displays For current and voltage

Geräte-Handbuch Device manual Notice pour utilisateurs

ULTRASONIC. Proximity Sensors. Series UX micro. Key-Features:

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

GS202 Encoder Switch

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

Displays Transducers. Displays and transducers

Temperature Switches

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

02/11/2015

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

ENCODER. CANopen Multiturn. Series , Key-Features:

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Absolute Encoder Multiturn

DX 342. Multi Function Counters with 2 Presets, 2 Relay Outputs and Serial RS 232 / RS 485 Interface. Operating Instructions. control motion interface

Absolute Encoders Multiturn

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Installation guide for PR302 v2.0 Rev. E

Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340

Measure & Analyze MM Automatic Quality Control System (AQCS) 5881B... Technical Data *

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

Solid State Remote Power Controller E /627

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Product Description. Contents. Fusion Series. New Information December 2003

Switching Power Supply

Operating Manual. DX345, DX346, DX347 and DX348 Multifunction Indicators with Pulse Inputs

DINALOG A 144 x 36 A1400 Light-Strip Indicator

PRODIS -SSI Digital Process Meter for SSI position sensors. Instruction Manual. Please read carefully before installation and operation!

adjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

BY340 and BY641. High Performance Low Cost Synchronous Controllers. Operating Instructions. control motion interface

PR602LCD v1.0 Installer Manual Rev. A

02/11/2015

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER

Accessories. Page 1/

PMIX (selectable sensor types)

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

Universal counter UZ 9648 Counting - length measurement - metering - positioning

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

GV204 Impulse Splitter for Incremental Encoders

POSICHRON PCQA Mounting Sets

Issue 03/2013. The Electronic Load

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Digital Indicator Solutions

Electronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition

Z58-6XX SERIES 6 Digits Universal Position Indicator for incremental or absolute encoders

MC800 Universal Motion Controller

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Inclination sensors 1-dimensional, measuring range

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

RS485 MODBUS Module 8I8RO

Intrinsically safe batch controller Batching Master 110i

Optical distance sensors. Dimensioned drawing

RS485 MODBUS Module 8I8O

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

OPERATING INSTRUCTIONS

Rotary Measurement Technology Absolute Encoders, Singleturn

LVX Control Unit. Features:

EY-EM : Remote I/O module, ecolink

Phone: Fax: Web: -

CONTENTS PRODUCT DESCRIPTION... 2

RXTH DUAL ROOM SENSOR / SWITCH

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Operating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features:

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

Pile Driver Weld Immune Sensors

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Time Counters mini "h", DC Version

USER MANUAL. SATEL i-link. I/O-converter. Version 1.4

RXTP ROOM TEMPERATURE

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

RS 485 Mini Modbus 1AO

Mini position indicator

MODEL: 40DN. Digital Panel Meters 40 Series

Flow sensors SFAB Key features

Intrinsically Safe Barriers

Transcription:

DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S: only display - WAY-SSI-A: display with analog output - WAY-SSI-G: display with two presets and switching outputs - : display with serial RS232 and RS485 interface - Master- or Slave operation with clock rates up to 1 MHz - Suitable for all SSI formats from 8 to 32 Bit - Numerous supplementary functions like linearisation, Bit blanking etc. - Big LED display 6 digits (15 mm) with adjustable brightness 17.12.14

- 2 - TECHNICAL DATA WAY-SSI Display 6 digits, 15 mm LEDs, high efficiency orange Panel cut out 91 mm x 44 mm Control inputs Input currents Input level HTL SSI input frequency range 3 inputs, A, B, C (PNP/NPN/Namur) 5.1 ma / 24 V (R i =4.7 Ω) Low: 0...2 V, High: 9...4.7 kω 100 Hz...1 MHz Min. pulse duration for Reset 5 ms Analog output (only WAY-SSI-A) Resolution 0...20 ma, 4...20 ma (Last max. 300 Ohm), 0...±10 V (max. 2 ma) 14 Bit + sign Accuracy 0.1% Serial interface (only ) RS232 / RS485 : 600-38400 Baud Switching output (only WAY-SSI-G) PNP, max. 35 V, max. 150 ma Supply voltage AC 115 / 230 V (±12.5 %) Supply voltage DC 24 VDC (17-30 V) AC Power 7.5 A Consumption (without sensor) 120 190 ma Aux. output for sensor 24 VDC, ±15%, 120 ma (with AC- and DC supply) Protection class Front IP65, Rear IP20 Working temperature 0...+45 C Housing material Electrical connection Conformity and Standards Scope of delivery Norly UL94-V-0 connecting terminal, signal line max 1.5 mm 2, AC-supply line max. 2.5 mm 2 CE compliant, EMC2004/108/EC: EN61000-6-2 and EN61000-6-3, LV2006/95/EC: EN61010-1 display, mounting parts, sealing, manual TECHNICAL DRAWING WAY-SSI

- 3 - ELECTRICAL CONNECTION WAY-SSI WAY-SSI-A WAY-SSI-S * * Note: at display WAY-SSI-S terminals 8, 9 and 10 are not connected. WAY-SSI-G

- 4 - DESCRIPTION Power supply The unit accepts DC supply from 17 V to 30 V when using terminals 1 and 2. The consumption depends on the level of the supply voltage (typical 130 ma at 30 V or 190 ma at 17 V, plus current taken from aux. output). For AC supply the terminals 0 VAC, 115 VAC or 230 VAC can be used. The total AC power is 7.5 VA. The diagrams below show a dotted line for grounding to PE. This connection is not really necessary, neither for safety nor for EMC. However, for some applications, it may be desirable to ground the common potential of all signal lines. When using the earthing option, please pay attention: All terminals and potentials marked GND will be earthed. Please avoid multiple earthing, i.e. when you use a DC power supply where the Minus is already connected to earth etc. Aux. voltage output for sensor supply Terminal 7 provides an auxiliary output of 24 VDC / 120 ma max. for supply of sensors and encoders. Control Inputs A,B and C (only ) Input A is used to activate a serial transmission (rising edge). Input B is not in use. Input C operates as a Set / Reset input (static function, active). In the basic Set-up menu, the inputs can be configured to PNP (signal must switch to +) or to NPN (signal must switch to +). This configuration is valid for all three inputs at a time. The factory setting is always PNP. Where NPN setting is used, please note: Open NPN inputs will always represent a logical HIGH state. Consequently, Input C has to be connected to GND externally to allow normal operation. If unconnected, the unit would be kept in a continuous Reset state. With models, also Input A must be tied to GND, and opening this connection will generate a rising edge to start a serial transmission Where your use 2-wire NAMUR type sensors, please select NPN, connect the negative wire of the sensor to GND and the positive wire to the corresponding input. Adjustable analog output (only WAY-SSI-A) A voltage output is available, operating in a range of 0... +10 V or 10 V... +10 V according to setting. At the same time, a current output 0/4 20 ma is available. Both outputs refer to the GND potential and the polarity changes with the sign in the display. The outputs are proportional to the display value and provide a 14 bits resolution. The maximum current on the voltage output is 2 ma, and the load on the current output can vary between 0 and max. 300 Ohms. The response time of the analog output to changes of the encoder position is approx. 7 msec. Optocoupler (transistor) outputs (only WAY-SSI-G) The outputs provide programmable switching characteristics and are potential-free. Please connect terminal 8 (COM+) to the positive potential of the voltage you like to switch (range 5 V...35 V). You must not exceed the maximum output current of 150 ma. Where you switch inductive loads, please provide filtering of the coil by means of an external diode. The optocoupler outputs provide a response time of approx. 5 msec with resistive load.

- 5 - DESCRIPTION Serial RS232 / RS485 Interface (only ) Ex factory the unit is set to RS232 communication. This setting can be changed to RS485 (2-wire) by means of an internal DIL switch. To access the DIL switch, you must remove the screw terminal connectors and the backplane. Then pull the board to the rear to remove the PCB from the housing. Removal of the back plane Location of the DIL switch RS 232: RS 485: Never set DIL switch positions 1 and 2 or DIL switch positions 3 and 4 to ON at the same time! After setting the switch, shift the print carefully back to the housing and avoid damage of the front pins for connection to the front keypad plate. Screen WAY-SSI-DR Connection of the RS232 interface PLC Connection of the RS485 interface

- 6 - HOUSING Aluminium housing GEH0IP65 black powder coating internal grounding terminal. protection class: IP65 dimensions: (W x H x D) 168 mm x 83 mm x 220 mm delivery: housing, mounting material without cable passages (must be drilled individually) Table housing TG9648 The housing is suited for all displays with front dimensions 96 x 48 mm self assembly dimensions: (W x H x D) 114 mm x 62 mm x 176 mm delivery: housing, mounting material ORDER CODE WAY-SSI-S WAY-SSI-A WAY-SSI-G Display only Display with analog output Display with 2 presets and switching output Display with serial interface RS232 / RS485 ACCESSORIES Housing Other TG9648 table housing Einstellung Pre-adjustment according to customer specifications GEH0IP65 Aluminium housing, IP65 Subject to change without prior notice. WayCon Positionsmesstechnik GmbH email: info@waycon.de internet: www.waycon.de Head Office Mehlbeerenstr. 4 82024 Taufkirchen Tel. +49 (0)89 67 97 13-0 Fax +49 (0)89 67 97 13-250 Office Köln Auf der Pehle 1 50321 Brühl Tel. +49 (0)2232 56 79 44 Fax +49 (0)2232 56 79 45