1 Processor-based bargraph with digital display vertical or horizontal MB3 3-digit digital display red display, optional green 30 dots bargraph display tricolour adjustment via factory default or directly on the sensor signal adjustable bargraph or dot operation dot operation with permanent midpoint display min/max memory plug-in terminal display flashing at threshold undercut or /exceedance zero-key fort he triggering of Hold, Tara permanent min/max value recording volume metering (Totaliser) programming interlock via access code protection class IP65 at the front option: 2 relay outputs option: sensor supply option: analog output option: galv. insulated digital input accessories: pc-based configuration-kit PM-TOOL with CD & USB adapter for devices without keypad, for a simple adjustment of standard devices status 06/02/ bargraph_gb.doc page 13 96x24

2 Bargraph Direct current Direct voltage ORDER NUMBER (without options) EUR Direct current, direct voltage Supply VAC horizontal MB3-3VT3HR.0001.S70AD 260,00 vertical MB3-3VT3VR.0001.S70AD 260,00 Supply VDC horizontal MB3-3VT3HR AD 260,00 vertical MB3-3VT3VR AD 260,00 Product key options: M B 3-3 V T 3 H R S 7 0 A D Device with a supply of VAC M B 3-3 V T 3 V R S 7 0 A D EUR M B 3-3 V T 3 H R A D Device with a supply of VDC M B 3-3 V T 3 V R A D 2 2 relay outputs 30,00 1 without keypad, programming on the backside via interface on demand X Analog output 0/4-20 ma, 0-10 VDC at VAC 90,00 X Analog output 0/4-20 ma, 0-10 VDC at VDC 125,00 2 Sensor supply 10 VDC / 20 ma incl. digital input at VAC 35,00 3 Sensor supply 24 VDC / 50 ma incl. digital input at VAC 35,00 2 Sensor supply 10 VDC / 20 ma incl. digital input at VDC 60,00 3 Sensor supply 24 VDC / 50 ma incl. digital input at VDC 60,00 3 Interface RS232 70,00 4 Interface RS485 70,00 I Digital input 10,00 G Green display, 8 mm height 10,00 status 06/02/ bargraph_gb.doc page 14

3 ORDER NUMBER (without options) EUR Direct current, direct voltage Special measuring input as inscripted, up to max. 300 VDC Supply VAC horizontal MB3-3VT3HR.0H01.S70AD 290,00 vertical MB3-3VT3VR.0H01.S70AD 290,00 Product key options: M B 3-3 V T 3 H R. 0 H 0 1. S 7 0 A D M B 3-3 V T 3 V R. 0 H 0 1. S 7 0 A D EUR 2 2 relay outputs 30,00 1 Without keypad, operation on the back on demand X Analog output 0/4-20 ma, 0-10 VDC 90,00 G 8 mm green display 10,00 Accessories Parameterisation software PM-TOOL, for devices without keypad, PM-Tool-MUSB4 89,00 for a simple adjustment of standard devices, incl. CD & USB-adapter. Programming is made via an interface on the back. status 06/02/ bargraph_gb.doc page 15 96x24

4 Connection examples MB3-devices with current/voltage input MB3 devices with current input/voltage input and sensor supply status 06/02/ bargraph_gb.doc page 16

5 Technical data Dimensions Housing B96 x H24 x T120 mm (T=144 mm incl. plug-in terminal) Panel cut-out x mm Fixing screw elements for a wall thickness of up to 3 mm Housing material PC Polycarbonate, colour black UL94V-0 Sealing material EPDM, 65 Shore Protection class IP65 standard at the front IP00 at the back Weight approx. 200 g Connection plug-in terminal; wire cross section up to 2.5 mm 2 Display Display 3-digit, 8 mm high Bargraph 30 digit, tricolour Segment colour red, optional green Display Overflow flashing of the two upper bargraph elements Underflow flashing of the two lower bargraph elements Display time seconds MB3-3VT3XR.0001 Measuring input Measuring span V / -22 ma...24 ma Measuring range V / 0/4.20 ma Input resistance Ri at ~200 kω / Ri at ~100 Ω Measuring error 0,1% of measuring range, ± 1 digit / 0,1% of measuring range, ± 1 Digit Temperature drift 100 ppm/k Measuring time seconds Measuring principle U/F-converter Resolution approx. 18 bit at 1 second measuring time MB3-3VT3XR.0H01 Measuring input Measuring span VDC / VDC / -1 1 ADC Measuring range VDC / 0 50 VDC / 0 1 ADC Input resistance Ri at ~1 MΩ / Ri at ~200 kω / Ri at ~0,2 Ω Measuring error 0.5% of final value, ± 1 digit Temperature drift 100 ppm/k Measuring time seconds Measuring principle U/F-converter Resolution approx. 18 bit at 1 second measuring time Output Relay with change-over contact 250 V / 5 AAC, 30 V / 5 ADC Switching cycle 30 * 10 3 at 5 AAC, 5 ADC ohm resistive load 10 * 10 6 mechanically Separation according to DIN EN50178 / Specific values according to DIN EN Analog output 0-10 VDC, 0/4-20 ma (16 Bit) switchable Sensor supply 24 VDC / 50 ma 10 VDC / 20 ma Digital input Input < 2.4 V OFF; 10 V ON; max. 30 VDC R I ~ 5 kω Interface Protocol manufacturer-specific ASCII RS baud, no parity, 8 databit, 1 stopbit Wire length max. 3 m RS485 Wire length baud, no parity, 8 databit, 1 stopbit max m Power pack Supply VAC 50/60 Hz / DC +/- 10% (max. 10 VA) VDC, galvanisch getrennt (max. 8 VA) Memory EEPROM Data life 100 years Ambient conditions Working temperature 0 to + 50 C Storing temperature -20 to + 80 C Climatic density relative humidity 0-85% on years average without dew CE-marking Conformity according to directive 2004/108/EG EMV EN Safety standard according to directive 2006/95/EG EN 61010; EN status 06/02/ bargraph_gb.doc page 17 96x24

6 Sealing Sealing Housing: 3,0 145,0 (154,0) Installation depth, incl. plug-in terminal (depth depends on options) 3,0 96,0 24,0 96,0 Gap for physical unit 24,0 135,0 (144,0) Installation depth incl. plug-in terminal (depth depends on options) Gap for physical unit status 06/02/ bargraph_gb.doc page 18

7 ORDER KEY MB3 Bargraph M B 3-3 V T 3 H R A D Standard type M-Line Dimension D Physical unit (free choice) Bargraph display B Version Installation depth A A 144 mm 3 incl. plug-in terminal Setpoints 0 no setpoint Housing size 2 2 setpoints B96xH24xD120 mm 3 Protection class Display type 1 Without keypad, operation on the V, A V back 7 IP65 / plug-in terminal Bargraph colours Tricolour T Supply voltage (red, green, orange) S VAC VDC, galv. insulated Resolution 30 points 3 Measuring input 1 Standard signal 0/4-20 ma, 0-10 VDC Adjustment horizontal H Analog output vertical V 0 none x 0-10 VDC, 0/4-20 ma Digital display 3-digit, 8mm, green G Sensor supply 3-digit, 8mm, red R 0 without 2 10 VDC / 20 ma, incl. digital input Digital input 3 24 VDC / 50 ma, incl. digital input none 0 1x digital input I DC devices Interface RS232 3 galv. insulated Special measuring inputs Interface RS485 4 galv. insulated H 300 VDC, 50 VDC, 1 ADC status 06/02/ bargraph_gb.doc page 19 96x24

8 Blind covers with fastening clamps GH ,90 status 06/02/ bargraph_gb.doc page 20 ZU

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance red display of -9999 99999 digits installation depth: 120 mm without

More information

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply gal/h Digital panel meter 4½digit DV4 Without setpoints Sensor supply status 22/05/06 panelmeteranalog_gb.doc page 9 Digital panel meter Direct voltage Direct current gal/h Direct voltage, direct current

More information

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features: User Manual M1 Thermocouple type K, B, S, N, E, T, R, L, J Technical features: red display of -1999 9999 digits (optional: green, orange or blue display) minimal installation depth: 97 mm without plug-in

More information

User manual M3. Thermocouple type L, J, K, B, S, N, E, T, R. Technical features:

User manual M3. Thermocouple type L, J, K, B, S, N, E, T, R. Technical features: User manual M3 Thermocouple type L, J, K, B, S, N, E, T, R Technical features: red display from -19999 99999 digits (optional green, orange, blue or tricolour display) installation depth: 120 mm without

More information

Process displays For current and voltage

Process displays For current and voltage Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma

More information

Bedienungsanleitung. DAL-101x800S Thermoelement Typ K, B, S, N, E, T, R, L, J

Bedienungsanleitung. DAL-101x800S Thermoelement Typ K, B, S, N, E, T, R, L, J Bedienungsanleitung DAL-101x800S Thermoelement Typ K, B, S, N, E, T, R, L, J Technical features: red display of -1999 9999 digits (optional: green, orange or blue display) minimal installation depth: 25

More information

User manual M3. Thermocouple Type K, B, S, N, E, T, R, L, J. Technical features:

User manual M3. Thermocouple Type K, B, S, N, E, T, R, L, J. Technical features: User manual M3 Thermocouple Type K, B, S, N, E, T, R, L, J Technical features: red display from -19999 99999 Digits (optional green, orange or blue display) minimal installation depth: 90 mm without plug-in

More information

Operating Instructions

Operating Instructions Operating Instructions DAL-111x200S Pt100 3-/4-wire -200,0 C 850,0 C / -328,0 F 1562,0 F Technical features: red display of -19999 99999 Digits (optional: green, orange or blue display) minimal installation

More information

User manual M3. Device performance:

User manual M3. Device performance: User manual M3 Setpoint generator 0 10 V; 0 20 ma Device performance: red display of -19999 99999 digits (optional: green, orange, blue) minimal installation depth: 90 mm without plug-in terminal definable

More information

optional with switching points

optional with switching points User manual M2 Setpoint generator 0 10 V; 0 20 ma optional with switching points Device performance: red display of -19999 99999 digits (optional: green, orange, blue) minimal installation depth: 70 mm

More information

User manual M2. Thermocouple Type K, B, S, N, E, T, R, L, J. Technical features:

User manual M2. Thermocouple Type K, B, S, N, E, T, R, L, J. Technical features: User manual M2 Thermocouple Type K, B, S, N, E, T, R, L, J Technical features: red display of -19999 99999 digits (optional: green, orange or blue display) minimal installation depth: 70 mm without plug-in

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

JUMO Quantum PID100/PID200/PID300

JUMO Quantum PID100/PID200/PID300 Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and

More information

Product overview M-Line

Product overview M-Line Product overview MLine Digital panel meters and builton enclosures e.g.: M17U digital 4digit multifunction device in 48x24mm (BxH) housing for metering of voltage, current, Pt100(0), thermocouple, frequency

More information

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.

More information

LBVR1718. Description. Features channel paperless recorder

LBVR1718. Description. Features channel paperless recorder LBVR1718 18 - channel paperless recorder Description It is the world first paperless recorder of the same size in highest resolution 640x480 pixels VGA TFT display, infrared detector, maximum 18 channels,

More information

Product data sheet accessories control and regulation Accessories AIRWIN

Product data sheet accessories control and regulation Accessories AIRWIN Product data sheet accessories control and regulation BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching,

More information

Tricolour device: Direct voltage / direct current signals 0-20 ma, 4-20 ma, 0-10 VDC

Tricolour device: Direct voltage / direct current signals 0-20 ma, 4-20 ma, 0-10 VDC User manual M2 Tricolour device: Direct voltage / direct current signals 0-20 ma, 4-20 ma, 0-10 VDC Technical features: red display of -19999 99999 Digits (red, green, orange changeable at off-limit) minimal

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

Displays Transducers. Displays and transducers

Displays Transducers. Displays and transducers JJ Displays JJ Transducers Displays and transducers DS_Displays_and_transducers 06/2016 225 Displays and transducers Our electronic devices for flow and volume measurement are suitable for all SIKA flow

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

User manual M3. Direct voltage signals shunt 0-60/150/300/1000 mv. Technical features:

User manual M3. Direct voltage signals shunt 0-60/150/300/1000 mv. Technical features: User manual M3 Direct voltage signals shunt 0-60/150/300/1000 mv Technical features: red display from -19999 99999 digits (optional green, orange, blue or tricolour display) installation depth: 120 mm

More information

User manual M3. Setpoint generator: with set point query. Device performance:

User manual M3. Setpoint generator: with set point query. Device performance: User manual M3 Setpoint generator: with set point query Device performance: red display of -19999 99999 digits (optional: green, orange, blue) minimal installation depth: 120 mm without plug-in terminal

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

Millenium II +: general characteristics

Millenium II +: general characteristics Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions

More information

Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC

Setpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC adjuster SG 9648 Output standard signals 0/4... 20 ma or 0/2... 10 V DC Features M LEDDisplay 14.2 mm red M Display range ± 9999(0) digit M Indicating range and decimal point free programmable M Set point

More information

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

Tricolour device: Direct current / direct voltage: 0/4-20 ma, 0-10 VDC

Tricolour device: Direct current / direct voltage: 0/4-20 ma, 0-10 VDC User manual M3 Tricolour device: Direct current / direct voltage: 0/4-20 ma, 0-10 VDC Technical features: tricolour display of -19999 99999 digits (red, green, orange, switchable at off-limit) installation

More information

User manual M2. Direct voltage / direct current 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

User manual M2. Direct voltage / direct current 0-20 ma, 4-20 ma, 0-10 VDC. Technical features: User manual M2 Direct voltage / direct current 0-20 ma, 4-20 ma, 0-10 VDC Technical features: red display of -19999 99999 Digits (optional: green, orange or blue display) minimal installation depth: 70

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM DS 96/48 PK Digital indicator Manual 42/33-90 EN Rev. 00 A1 A2 DIM E DS 96/48 PK Digital Indicator Manual Document No. 42/33-90 EN Edition 06.01 Revision 00 Manufacturer: ABB Automation Products GmbH Höseler

More information

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter

More information

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

Standard-Signal-Panelmeter S 9648 Industry standard signals - integrated transmitter-supply - potentiometer

Standard-Signal-Panelmeter S 9648 Industry standard signals - integrated transmitter-supply - potentiometer Martens Elektronik GmbH Kiebitzhörn 18 D22885 Barsbüttel/Germany www.martenselektronik.de F+49(0)40670 730 Fax +49(0)40670 73288 J info@martenselektronik.de StandardSignalPanelmeter S 9648 Industry standard

More information

Display and Monitoing Units

Display and Monitoing Units Display and Monitoing Units DISPLAY AND MONITOrING UNITS 13 The universal display unit HDA 5500 provides the means of visualizing and further processing the signals from our sensors. The unit is designed

More information

Universal counter UZ 9648 Counting - length measurement - metering - positioning

Universal counter UZ 9648 Counting - length measurement - metering - positioning +49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Universal counter UZ 9648 Counting - length measurement - metering - positioning Features M LED-Display 14.2mm

More information

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0. LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

02/11/2015

02/11/2015 48 x 48 Max. Counting Speed 5 KHZ Green backlit LCD display Part number 87629111 Counter, Preselection chronometer Maximum input frequency 5 k Hz Simple parameter setting, configuration using text menus

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet

More information

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Modular solution based on the combination of two units: VIM-E analysis unit and VIM-X universal power supply and RS485 communication unit.

More information

Technical data. Safety notes. Product features

Technical data. Safety notes. Product features Technical data sheet BKN230-MOD 11-00002.F Communication and power supply unit for motorised fire dampers Communication via RTU (RS-48) AC 230 V supply via Euro plug Power is supplied to the actuators

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

AC5160 SiPass integrated controller kit

AC5160 SiPass integrated controller kit AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one

More information

Issue 03/2013. The Electronic Load

Issue 03/2013. The Electronic Load Issue 03/2013 ZS Electronic Loads, PL Series Interface overview RS-232 USB / GPIB LAN System bus Analog X Analog isolated / X Standard ption / not available PL506 PL1006 Voltage Current Resistance 3) Model

More information

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast

More information

Digital Panel Meters Modular signal s conditioner Type USC-DIN

Digital Panel Meters Modular signal s conditioner Type USC-DIN Digital Panel Meters Modular signal s conditioner Type DIN Linearization of V and A inputs up to 6 points Multiinput modular signal s conditioner 0.% RDG basic accuracy TRMS AC current and voltage measurements

More information

Time Counters mini "h", DC Version

Time Counters mini h, DC Version Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet GM24A-MOD Communicative damper actuator for adjusting dampers in technical building installations orque motor 40 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion

More information

SX90 Process Controller

SX90 Process Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Micro Motion Model 7950 and Model 7951 Signal Converters

Micro Motion Model 7950 and Model 7951 Signal Converters Product Data Sheet PS-001316, Rev. B April 2013 Micro Motion Model 7950 and Model 7951 Signal Converters Micro Motion Model 7950 and Model 7951 signal converters are the perfect complement to Micro Motion

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

SWTD-1000 Speed Switch / Transmitter Operating Manual

SWTD-1000 Speed Switch / Transmitter Operating Manual SWTD-1000 Speed Switch / Transmitter Operating Manual 3690 NW 53 rd Street Fort Lauderdale, FL 33309 Ph 954-739-4300 Fax 954-486-4968 www.dynalco.com TABLE OF CONTENTS 1. Safety Instructions 1 2. Product

More information

Tank-Display TA 1010 Content measurement for different formed tanks by hydrostatic pressure or distance measurement Features

Tank-Display TA 1010 Content measurement for different formed tanks by hydrostatic pressure or distance measurement Features +49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Tank-Display TA 1010 Content measurement for different formed tanks by hydrostatic pressure or distance measurement

More information

Indicomp 4 Bargraph Indicator

Indicomp 4 Bargraph Indicator Data Sheet 10/30-2.16-EN Indicomp 4 Bargraph Indicator Display is optionally LCD active: self-luminuous green on black self-luminuous green on blue LCD passive: self-luminuous black on light grey 2 input

More information

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211

EE211. Humidity and Temperature Transmitter for Continuous High Humidity. Features. 42 v1.3 / Modification rights reserved EE211 EE211 Humidity and Temperature Transmitter for Continuous High Humidity The is dedicated for accurate and long term stable measurement under continuous high humidity (>85 % RH) and condensing conditions in demanding

More information

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

Users guide PB9648. Profibus Panelmeter 6-digit

Users guide PB9648. Profibus Panelmeter 6-digit Users guide PB9648 Profibus Panelmeter 6-digit Martens Elektronik GmbH Kiebitzhörn 18 D-22885 Barsbüttel Tel. +49(40)-670 73-0 Fax +49(40)-670 73-288 Status 04/07 / PB9648e.doc Contens 1. Brief description...3

More information

Temperature Switches

Temperature Switches ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

MOD-IO9 Modbus Input / Output Modules, Wall Mounted Product sheet MOD3.9 Type MOD-IO9 MOD-IO9 Modbus Input / Output Modules, Wall Mounted MOD-IO9 and MOD-IO9-AI have been designed to be a compact wall mounted Modbus RTU input and output module. The module

More information

Programmable Relay ZEN V2 Units

Programmable Relay ZEN V2 Units Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty

More information

itemp TMT180 Technical information

itemp TMT180 Technical information Technical information itemp TMT180 Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B Application PC programmable (PCP) Temperature

More information

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General

More information

Controller. Applications. Characteristics. Extruder machines Heating control systems Facility engineering Wide range of instrumentation

Controller. Applications. Characteristics. Extruder machines Heating control systems Facility engineering Wide range of instrumentation GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Controller Characteristics System Output Case 2-point-controller, 3-point-controller,

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT Next-generation PCB Relay Available in Various Models ROHS compliant. High sensitivity: (250mW) and high capacity (16A) models available Low profile: 15.7 mm max. in height. Conforms to EN 61810-1, UL508

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet SF24A-MOD Communicative spring-return actuator with emergency control function for adjusting dampers in technical building installations orque motor 20 Nm Nominal voltage AC/DC 24 V

More information

02/11/2015

02/11/2015 24 x 48 Hour CTR24 non-backlit model Part number 87622162 Display : 8-digit LCD, height 8 mm Built-in module for voltage inputs 10 260 VAC/DC () 4 timing ranges : 99,999.99 hrs - 99,999.59 hrs - 999,999.9

More information

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet Digital Process Meters Digital Process Meter for analog Sensors Datasheet Copyright ASM GmbH Am Bleichbach 18-24 85452 Moosinning Germany The information presented in this data sheet does not form part

More information

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates 1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for

More information

Energy Management Modular Energy meters Type EM2-96

Energy Management Modular Energy meters Type EM2-96 Energy Management Modular Energy meters Type EM2-96 Product Description µp-based modular energy meter with a built-in configuration key-pad. The energies are both partial and total counted. The housing

More information

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

Strain Gauge Converter

Strain Gauge Converter EN Z-SG General Description Module Z-SG is a strain gauge signal converter. Measurements taken using the 6-wires or 4-wires technique are available through Modbus-RTU serial protocol or the analog output.

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to 4-point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the

More information

User manual M3. Alternating voltage / Alternating current signal rms-value (TRMS) VAC, VAC, 0-1 AAC, 0-5 AAC. Technical features:

User manual M3. Alternating voltage / Alternating current signal rms-value (TRMS) VAC, VAC, 0-1 AAC, 0-5 AAC. Technical features: User manual M3 Alternating voltage / Alternating current signal rms-value (TRMS) 0-300 VAC, 0-600 VAC, 0-1 AAC, 0-5 AAC Technical features: red display of -19999 99999 digits (optional: green, orange,

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE In times where energy conservation is a top priority for all progressive enterprises, the measurement of flow rates and consumption is becoming more and

More information

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the measured values.

More information

TM3AI4 module TM3-4 analog inputs

TM3AI4 module TM3-4 analog inputs Characteristics module TM3-4 analog inputs Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

Digital Panel Meters Modular Indicator and Controller Type UDM35

Digital Panel Meters Modular Indicator and Controller Type UDM35 ISE, Inc 000 Royalton Rd. Cleveland, OH 4433 Tel: (440) 2373200 Fax: (440) 237744 http://iseinc.com Digital Panel Meters Modular Indicator and Controller Type UDM35 Front protection degree: IP67, NEMA4x

More information

DIGITAL DISPLAY. for Industry Applications. Series PAXD. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series PAXD. Key-Features: DIGITAL DISPLAY for Industry Applications Series PAXD Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Plug-In Cards...4 Programming & Software...5 Order Code & Accessories...6-5

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow

More information

DIGITAL ANZEIGE. for Industry Applications. Series PAXP, PAXDP. Key-Features:

DIGITAL ANZEIGE. for Industry Applications. Series PAXP, PAXDP. Key-Features: DIGITAL ANZEIGE for Industry Applications Series PAXP, PAXDP Key-Features: Content: Technical Data.2 Technical Drawing...3 Electrical Connection PAXP...3 Electrical Connection PAXDP...4 Plug-in Cards...5

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to -point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

LLR-MOD Modbus Light Level and Occupancy Sensor

LLR-MOD Modbus Light Level and Occupancy Sensor Product sheet SN1.418 Type LLR-MOD LLR-MOD Modbus Light Level and Occupancy Sensor The LLR-MOD sensors are designed to measure Light Level (LUX) in the room spaces and have built-in RS485 Modbus communication

More information

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1 TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT NOTICE... 2 PRODUCT CONFORMITY... 3 WARRANTY AND SAFETY INSTRUCTIONS... 4 1 GENERAL... 5 1.1 SATEL I-LINK 100 MODBUS I/O- CONVERTER... 5 2 SPECIFICATIONS...

More information

WP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports

WP-Line 351 MK ll Combi I/O. control systems. Optimized I/O Combi module. 2 serial COM-ports Optimized I/O Combi module 2 serial COM-ports 16 digital outputs/26 digital inputs/4 high-speed counter inputs 4 analog outputs/8 analog inputs/8 PT100 inputs/2 thermistor inputs Compact design Improved

More information

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only)

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only) PRODUCT NEWS Product Discontinuation Notices August 1, 2011 Proximity Sensors No. 2011248E-2 Discontinuation Notice of Compact proximity sensor (for china area only) Product Discontinuation Recommended

More information

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers

PEAK TM. PEAK TM controllers. Mid-Market BAS Smart equipment controllers. HVAC/R controllers Virtual Branch ecatalogue click here controllers HVAC/R controllers The PEAK 18 and PEAK 32 Controllers are configurable controllers that can be switched between MS/TP, Modbus RTU, and N2 Communication

More information

Hand-held thermometer Model CTH7000

Hand-held thermometer Model CTH7000 Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference

More information

Manual and Protocol Description

Manual and Protocol Description Communication Module MSR240 1 Manual and Protocol Description Overview The MSR240 Communication Module serves as an interface between a MSR210 or MSR211 Basic Module and a standard serial data communication

More information

MID approval no. DE-08-MI004-PTB004 Date of release

MID approval no. DE-08-MI004-PTB004 Date of release 1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application

More information

JUMO diraview 104/108/116/132

JUMO diraview 104/108/116/132 Page 1/19 JUMO diraview 104/108/116/132 Digital indicator Brief description The digital indicator series comprises five freely configurable, universally usable devices in various DIN formats to display

More information

Cube67 - Modular I/O station

Cube67 - Modular I/O station Compact modules Cube67 DI16 C 8xM12 Cube67 DI8 C 4xM12 Cube67 DI8 C 8xM8 Digital inputs Art.-No. UL 56602 UL 56612 UL 56622 approx. 50 ma approx. ma Terminator integrated Configuration PIN 2 input/diagnostic

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information