Proposed Copper EFM PHY

Similar documents
Review of the 5 Criteria

EFM-Copper: Operators Perspective. Dong Wei, Pete Youngberg, Charles Cook,

10Gb/s on FDDI-grade MMF Cable. 5 Criteria Discussion Slides. SG 10Gb/s on FDDI-grade MMF

5 Criteria Responses

Summary of Proposed Responses to CSD

10Gb/s on FDDI-grade MMF Cable. 5 Criteria Motions. 13 January 2004

IEEE Criteria for Standards Development (CSD)

Forwarding and Queuing for Time-Sensitive Streams

100BASE-Cu Dual Mode Proposal

IEEE Five Criteria

Five Criteria Responses APPROVED WG (November 15, 2012) and 802 EC (November 16, 2012) Reduced Twisted Pair Gigabit Ethernet PHY Study Group

John D Ambrosia Dell. IEEE Next Gen BASE-T SG 1

Time Synchronization Study Group

Loop Spectrum Compatibility and Management

IEEE Criteria for Standards Development (CSD)

IEEE Criteria for Standards Development (CSD)

IEEE Ethernet Working Group 19 July 2012 San Diego, CA

CSD DRAFT for considerations 2.5G/5G Ethernet Backplane & Copper

The 5-Criteria for EPoC

Ethernet PON (EPON) and the PAR + 5 Criteria

Broad Market Potential

IEEE Congestion Management Study Group November Plenary Report. San Antonio, TX November, 2004

IEEE Criteria for Standards Development (CSD)

Five Criteria Responses

50 GbE 40km Objective 5C Study Group Discussion

Credit based Flow Control PAR, 5 Criteria & Objectives

10 Gb/s Ethernet on FDDI-grade MM Fiber

1. Broad Market Potential o Broad set(s) of applications o Multiple vendors, multiple users o Balance cost, LAN vs. attached stations 802.

1. An IEEE MAN shall be compatible with relevant and applicable IEEE 802 standards:

Draft 5 Criteria, v6 (Wordsmithed to align with Draft PAR, v7) September Interim, IEEE 802 September 06. AVB task group

40Gb/s Ethernet Single-mode Fibre PMD Study Group Proposed 5-Criteria Responses

DSL Consortium. VDSL2 Rate vs. Reach Interoperability Test Suite (V2RR) Version Last Updated: March 24, 2008

IEEE sub10-00/03r1. IEEE Broadband Wireless Access Working Group

IEEE DMLT Study Group Straw-man DRAFT PAR and 5C

SDSL and other Modulation Strategies

IEEE 802 Plenary Kauai Nov Criteria 10GBASE-CX4 10GBASE-CX4 1

Proposed CSD Responses: Objectives Related to operation over DWDM System

General Description. Multi-Service Access Platform. 3/03/ W-Rev3

802.3bs PROJECT DOCUMENTATION CONSIDERATION. John D Ambrosia, Independent December 2, 2015

COMMITTEE T1 TELECOMMUNICATIONS Working Group T1E1.4 (DSL Access) Newport Beach, CA; Feb 17 th, 2002 CONTRIBUTION

IEEE Criteria for Standards Development (CSD)

Standard VDSL Technology

IEEE Gb/s per Lane Electrical Interfaces and Electrical PHYs (100GEL) Study Group Closing Report

25GSMF Study Group: Draft CSD Responses

IEEE Five Criteria

IEEE Criteria for Standards Development (CSD)

IEEE Criteria for Standards Development (CSD)

VDP extension to support NVO3 CSD. Qcn-csd-0715-v01 July2015

The 5 Criteria for EPoC

DEERE AFFIDAVIT Attachment OOO

Bob Matthews Technical Manager CommScope Canada

Alcatel-Lucent Internal

WHITE PAPER. G.fast WHITE PAPER. G.fast promises to seriously boost signal speeds to customer premises. OVERVIEW

DEERE AFFIDAVIT Attachment PPP

Global Ethernet Standards

Wired Broadband Access How far can we go with wires?

IEEE GBASE-T T Study Group Agenda and General Information. Vancouver, BC January 9, 2003

25GSMF Study Group: Work Items and Goals for Jan Meeting

COMMITTEE T1 TELECOMMUNICATIONS Working Group T1E1.4 (DSL Access) Baltimore; August 25-26, 1999

4-Port 10/100/1000T Ethernet to VDSL2 Bridge w/g.vectoring

Network Access Technology Consideration in Europe. By Helge Tiainen of InCoax and Chair of the MoCA Access Work Group

IEEE Beyond 10km Optical PHYs SG - Discussion of Objectives / CSD

Provider Bridging Remote Access PAR and 5c

IEEE YANG Data Model(s) Study Group Closing Report

You Can t Fake Fast. The Promise of 100 Mbps and Vectored Services Raises Bar on Network Quality. White Paper

25 Gb/s Ethernet over a single lane for server interconnect Study Group: status and work

FTTH: B-PON, GPON, EPON. Don McCullough VP Marketing Ericsson May 9, 2007

STANDARD TERMS DETERMINATION FOR CHORUS UNBUNDLED BITSTREAM ACCESS SERVICE SCHEDULE 1 UBA SERVICE DESCRIPTION PUBLIC VERSION

Passive Optical LAN Executive Summary. Overview

IEEE Backplane Ethernet Study Group Agenda and General Information. Vancouver, BC January 12, 2004

Internet Access Technologies

Table of Contents. Chapter Goals. Digital Subscriber Line. Chapter Goals

SHDSL Baseline Proposal

G.fast Ultrafast Access Technology Standardization in ITU-T

1-Port 10/100/1000T Ethernet to VDSL2 Converter w/ G.vectoring

Ethernet over VDSL2 Converter/Bridge VC-231G VC-234G

CSIS Frequency Division Multiplexing. Basic Types of Multiplexing. Frequency Division Multiplexing. Frequency Division Multiplexing.

Zero-touch VDSL2 vectoring

Few Multiplexing Applications

Building the Next Generation Network in the 21 st Century

Chapter 1: introduction

ToR-24. Field Trail for Broadband (DSL) Dynamic Line Management to improve service quality. PTCL Document TOR DSM/DLM

A Cost-Effective Fixed and Mobile Broadband Deployment Methodology for

Digital Loop Carrier Market Table of Contents / List of Tables and Figures. Table of Contents EXECUTIVE SUMMARY

Subscriber Management -Billing data - Authentication NAP. Backhaul Access. Backhaul. Backhaul Access CCU BaseT CCU3000 B/U CCU3000

Few Multiplexing Applications

Transition from TDM to All IP Network

dsl strategies otal Access Systems

Multiplexing (Recap)

For internal circulation of BSNL only

Nokia Passive Optical LAN solution

EFM Copper. The copper baseline: What, how and why. EFM May, 2002 Hugh Barrass (Cisco Systems), On behalf of IEEE 802.3ah copper sub task force

This tutorial has been designed to help beginners understand the basic concepts of WiMAX.

Extended Reach Baseline Proposal

IEEE GBASE-T Study Group Closing Plenary Meeting Report

Broadband Wireless Access - Enabling Broadband Qatar. Contents

1-Port 10/100/1000T 802.3at PoE+ Ethernet to VDSL2 Converter

Edge Virtual Bridging Draft PAR. PAR Request Date: 15 November PAR Approval Date: PAR Signature Page on File: No

Performance Comparison of E.SHDSL and MIMO on DMT Bonded Systems on Real Copper Cable

The IEEE WirelessMAN Standard for Broadband Wireless Metropolitan Area Networks

Transcription:

Proposed Copper EFM PHY Patrick Stanley, Elastic Networks, pstanley@elastic.com (678)297-3103 1

Co-Sponsors of This Presentation Bob Brown, Verizon Avenue, bob.m.brown@verizon.com Dean Hudson, Citizens Communications, dehudson@czn.com Sherman Ackley, National Rural Telecommunications Cooperative (NRTC), sackley@nrtc.org Robert Liethman, New South Communications, robert@newsouth.com John Stegenga, Bass Hotels (Holiday Inn, Intercontinental, Crowne Plaza, Staybridge), john.steganga@basshotels.com Wes Wycoff, Nortel Networks, wwycoff@nortelnetworks.com Richard Brand, Nortel Networks, rbrand@nortelnetworks.com Anand Injeti, ST Microelectonics, anand.injeti@st.com Darin Kincaid, ST Microelectronics, Darin.KINCAID@st.com David Fauser, Mitel, david_fauser@mitel.com Nick Yasui, Hitatchi Telecom USA, nyasui@hitel.com 2

Proposed PHY Propose that the 100BaseCu PHY, as described in Fast Robust EFM, Elastic Networks [1], be studied as a candidate for the copper based EFM, to bridge the gap from the Optical MAN to the subscriber LAN when the infrastructure does not support optical EFM options 100BaseCu IS NOT VDSL. It is a half-duplex, burst mode, frequency agile, symmetry agile, spectrally compatible access technology that builds on successfully deployed technology, and was shown in [1] to provide superior rate and reach performance compared to VDSL and ADSL. The rest of this presentation outlines how 100BaseCu meets the 5 Criteria for successful project approval 3

1) Broad Market Potential a) Broad sets of applicability One technology that can serve customers serviced by in- building and outside plant wiring. (See following Slides) b) Multiple vendors and numerous users Technology is currently being licensed and built by multiple vendors. Equipment vendors, and Carriers have co-sponsored this proposal. c) Balanced costs (LAN versus attached stations) Comparable product costs to VDSL with significantly lower operational and deployment costs. Ethernet vendors and users are able to achieve an optimal cost balance between the network infrastructure components and the attached stations. 4

Loop Length Distributions Contribution T1E1.4/2001-132 132 [2], from Telcordia Technologies, gives the following statistics from a 1990 DLC Survey of 686 DLC loops that were sampled from 126 wire centers in 5 regions: 10% of Loops DLC fed (had grown to 30% nationwide by 2000) 60.6% of DLC loops CSA compatible (length <= 12kft 26AWG) Assumes that DLC s built since 1990 have ~100% CSA compatibility Of the CSA compatible loops: Avg 90% 75% Median 25% Loop Length (ft) from RT to TU-R 3808 7824 5304 3263 1940 Contribution T1E1.4/2000-219R1 219R1 [3], from Telcordia Technologies, gives the Following statistics from a 1983 Survey of business and residential ial loops in 5 Of 7 regions in the United States. Of non-loaded loops: Avg 90% 75% Median 25% Loop Length (ft) from CO to TU-R 13000 10000 6500 3000 5

Loop Length Distribution Graphs Distribution of 26 AWG Loop Lengths from 1990 DLC Loop Survey Probability of Loop Length <= x 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Loop Length (kft) Series1 Distribution of Non-Loaded 26 AWG Loop Lengths From 1983 Loop Survey Probability of Loop Length <= x 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 1 2 3 4 5 6 7 8 9 10 11121314151617 Loop Length (kft) Series1 6

Addressable Market, CO & DLC Loop Reach for MINIMAL CONNECTION, based on simulated cases found in [1] : ❿ ❿ ❿ FSAN998 Compliant VDSL Band Plans: 3000 ft Draft Trial Use Standard Compliant VDSL/ADSL Band Plans: 12000 ftf Fast Robust EFM (Carrier Grade Ethernet) Band Plan: 20000 ft DLC Market Addressed: ❿ FSAN998 Compliant VDSL Band Plans: 41% ❿ Draft Trial Use Standard Compliant VDSL/ADSL Band Plans: 85% ❿ Fast Robust EFM (Carrier Grade Ethernet) Band Plan: >99% CO Market Addressed: ❿ FSAN998 Compliant VDSL Band Plans: 24% ❿ Draft Trial Use Standard Compliant VDSL/ADSL Band Plans: 86% ❿ Fast Robust EFM (Carrier Grade Ethernet) Band Plan: >99% 7 Total OSP Market Addressed: ❿ FSAN998 Compliant VDSL Band Plans: 29% ❿ Draft Trial Use Standard Compliant VDSL/ADSL Band Plans: 86% ❿ Fast Robust EFM (Carrier Grade Ethernet) Band Plan: >99%

Data Rate, CO & DLC Loop Reach for 10Mbps, based on full binder self disturber case [1] : ❿ ❿ ❿ FSAN998 Compliant VDSL Band Plans: 4500 ft Draft Trial Use Standard Compliant VDSL/ADSL Band Plans: 4500 ft Fast Robust EFM (Carrier Grade Ethernet) Band Plan: 11000 ft DLC Market Addressed: ❿ FSAN998 Compliant VDSL Band Plans: 57% ❿ Draft Trial Use Standard Compliant VDSL/ADSL Band Plans: 57% ❿ Fast Robust EFM (Carrier Grade Ethernet) Band Plan: 84% CO Market Addressed: ❿ FSAN998 Compliant VDSL Band Plans: 36% ❿ Draft Trial Use Standard Compliant VDSL/ADSL Band Plans: 36% ❿ Fast Robust EFM (Carrier Grade Ethernet) Band Plan: 82% Total OSP Market Addressed: ❿ FSAN998 Compliant VDSL Band Plans: 42% ❿ Draft Trial Use Standard Compliant VDSL/ADSL Band Plans: 42% ❿ Fast Robust EFM (Carrier Grade Ethernet) Band Plan: 83% 8

Copper Bridge for Optical MAN FTTuser: YANKEE Group estimates 5-7% 5 of buildings served by fiber Even with FTTB, need bridge In Building: Even by 2003, approximately 60% of in building market will require use of unstructured Cat 3 wiring to reach tenants Buildings that could be reached by copper bridge from optical MAN: Chicago: 42%-67% of buildings within 1-51 5 miles of fiber LA: 40%-73% of buildings within 1-51 5 miles of fiber 9

Higher Data Rates on Short Loops 100000 Comparison of Raw Theoretical Data Rate. -140dBm/Hz Noise Floor. 26 AWG. 100BaseCu Bitrate (kbps) 80000 60000 40000 Draft T1E1.4 VDSL/ADSL Trial Use Standard Downstream 20000 0 0 3 6 Loop Length (kft) Draft T1E1.4 VDSL/ADSL Trial Use Standard Upstream 10

2) Compatibility a) Conformance with 802 Overview and Architecture As a supplement to IEEE Std 802.3, the proposed project will remain in conformance with the 802 Overview and Architecture. b) Conformance with 802.1D, 802.1Q, 802.1p As a supplement to IEEE Std 802.3, the proposed project will remain in conformance with 802.1D, 802.1Q and 802.1f, though extensions to these standards may be proposed as additional work items. c) Compatible managed object definitions As a supplement to IEEE Std 802.3, the proposed project will follow the existing format and structure of 802.3 MIB definitions. 11

3) Economic Feasibility a) Known cost factors, reliable data. Products based on EtherLoop are being manufactured and sold internationally today. Costs have been established and are based on data from multiple manufacturers. b) Reasonable cost for performance. EtherLoop shares the same cost advantages of Ethernet as compared to ATM technologies. c) Consideration of installation costs. EtherLoop is extremely tolerant to variances in the copper plant. It automatically adjusts it operating parameters to optimize performance for a given loop, greatly reducing costs of installation for the service provider 12

4) Distinct Identity a) Substantially different from other IEEE 802 standards. There is no existing 802 standard or approved project appropriate e for wire line access over the vast majority of outside plant and in building ing wiring, using the Ethernet access protocol and frame format, with the exception of certain combinations of operating speed and media defined in various supplements to IEEE Std 802.3. This project will expand that set to include all non-loaded copper used for wireline voice service today. b) One unique solution per problem (not two solutions to a problem). This PHY would provide a single solution for all non-loaded copper used for wireline voice service today. c) Easy for the document reader to select the relevant specification. The proposed project will be formatted as a supplement to IEEE Std 802.3, making it easy for the document reader to select the EFM specification. cation. Ethernet over CAT 3 copper is the distinction. 13

5) Technical Feasibility a) Demonstrated system feasibility. 100BaseCu builds on the base technology of EtherLoop, which been deployed in hundreds of thousands of loops in multiple countries.. Has 3 years of successful deployment history. b) Proven technology, reasonable testing. 100BaseCu builds on the base technology of EtherLoop, which has been validated by Telcordia. It is fully compliant with the T1.417 17 standard for spectral compatibility. It has been tested in the lab l in fully filled binder groups and the presence of multiple interferers. (See( following slides for simulated vs. measured performance) c) Confidence in reliability. 100BaseCu builds on the base technology of EtherLoop, which has been widely deployed by over 70 phone companies who have validated it s reliability in the field. 14

Simulation of EtherLoop vs. Measured Data EtherLoop simulations performed in January 1998, prior to availability of 6.67 Mbps product, and prior to full characterization testing of 4Mbps product. Test results performed on Consultronics Loop simulator for single loop test, and in real copper binders for multi-disturber tests. Based on this track record, high degree of confidence that similar agreement will be met with 100BaseCu 15

Single Loop Case, No Disturbers 7.00 Downstream Single Service RFC2544 Throughput 6306(fw3.3.9D) / SP600(fw3.2.5) 6.00 5.00 4.00 Mbps 3.00 1518 Byte - Actual 1518 Byte - Simulated 2.00 1.00 16 0.00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Loop Length(Kft) - 26AWG

5 Disturber Case (Characterization Continues) Downstream 6-Pair(6 Active) 6306 (fw3.3.9d) / SP600 (fw3.2.5) 7.00 6.00 5.00 Mbps 4.00 3.00 1518 Byte - Actual 1518 Byte - Simulated 2.00 1.00 0.00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Loop Length(Kft) - 26AWG 17

Proposal 18

References [1] Fast Robust EFM, Elastic Networks, IEEE 802.3 EFM Study Group, Plenary, March 2001 [2] Statistical Variables for Evaluating Compatibility of Remote Deployments, Telcordia Technologies, pursuant to work supported by BellSouth, SBC, and Verizon, T1E1.4/2001-132, 132, May 2001 [3] 2B1Q SDSL Crosstalk: Mixed Bit Rates and Numbers of Disturbers, Telcordia Technologies, pursuant to work supported by BellSouth and SBC, T1E1.4/2000-219R1, 219R1, November 2000 19