Operating instructions Safety-monitoring module SRB 207AN. 1. About this document. Content

Similar documents
Operating instructions Safety-monitoring module SRB 301LC / LCI / LCI/7. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301LC/B SRB 301LC/B-R. 1. About this document. Content

Operating instructions Safety-monitoring modules SRB201ZH -24VDC. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301MC SRB 301MC-ST. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301ST-230V. 1 About this document

Operating instructions Safety-monitoring module SRB 324ST V About this document. Content

Operating instructions Safety-monitoring module SRB 100DR. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301HC/R-24V / -230V. 1 About this document

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module SSW 301HV. 1. About this document. Content

Operating instructions Safety-monitoring module SRB301STV.2 /CCV.2 /PCV.2 SRB301STV.3 /CCV.3 /PCV About this document.

Operating instructions Safety-monitoring module SRB 324ST V.3. 1 About this document

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

Operating instructions Safety-monitoring module SRB 301ST V.2. 1 About this document

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Safety sensor BNS About this document. Content

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Operating instructions Fail-safe standstill monitor FWS About this document. Content

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safety-monitoring module SRB-E-204ST / SRB-E-204PE. Content. 1. About this document

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content

Operating instructions Hinge safety switch TESZ. 1. About this document. Content

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

Operating instructions Safety sensor EX-BNS40S. 1. About this document. Content

Operating instructions Position switches EX-Z/T G/D. 1. About this document. Content

Datasheet - SRB 301LC/B-24V

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Datasheet SRB301ST 24V (V.2)

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

Operating instructions Safety mats SMS 4 SMS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Datasheet - SRB 402EM-24V

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Operating instructions Safety switch with interlocking function AZM 200D. 1. About this document. Content

Operating instructions Safety switch with interlocking function MZM 100 B. 1. About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

Operating instructions Solenoid interlock MZM About this document. Content

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content

Encontrará el manual de instrucciones actual en su idioma oicial de la UE en nuestra página de Internet

Operating instructions Solenoid interlock MZM 100 MZM 100 B. 1. About this document. Content

Operating instructions Two-hand control panel and stands. SEPK02.0 / SEPG05.3 / SEP01.0 /SEP01.4 / SEPLC05.2 / SEP07.0 / SEP09.

Datasheet - SLB 200-C04-1R

Operating instructions Command and signalling devices. E programme, N programme and R programme. 1. About this document. Content

Operating instructions Safety sensor RSS About this document. Content. 7 Set-up and maintenance 7.1 Functional testing 8 7.

Datasheet - AZM300Z-ST-1P2P-A

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Datasheet - MZM 100 B ST-1P2PW2REM-A

Datasheet AZM 161 Z ST1 AS RA

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Datasheet - AZM 200 BZ ST-T-AS P

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Datasheet - CSS 11-30S-D-M-ST

Safety controlling systems PROTECT series / Version 02

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Datasheet - AZM 200SK-T-1P2PW

AS-i Safety Relay Output Module with Diagnostic Slave

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Operating instructions Safety light curtain / safety light grid SLC440COM SLG440COM. Version 2.0. Content. 1. About this document

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Datasheet - BNS ZG

Datasheet - RSS 36-D-R-ST

PNOZ s1. Safety relays. Operating Manual EN-07

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Datasheet - BNS ZG-ST

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Operating instructions Joystick switch RK/NK. 1. About this document. Content

Operating Manual -ENGLISH- Page 1 KWG-ISO

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

SR101A. User Information for SR101A. Correct Use

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Power supply CP-E 48/1.25 Primary switch mode power supply

onlinecomponents.com

Operating instructions. Speed monitor D / / 2014

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

PNOZ s2. Safety relays. Operating Manual EN-07

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

SAFETY PRESSURE MATS GENERAL PRODUCT FEATURES

Operating Instructions

Non-Contact Safety System CES-AZ

Operating instructions Safety light curtain / safety light grid SLC445 SLG445. Content

PNOZ s9. Safety relays. Operating Manual EN-08

Power supply CP-D 12/2.1 Primary switch mode power supply

Non-Contact Guard Monitoring Safety System BNS/AES

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GG711S

E-STOP relays, safety gate monitors

MSI-RM2 Safety Relays

MECHAN. CAT 4 SIL 3 PLe. Installation Guide : SCU-1 & HE Safety Switches. Description. Operation. Applications. Declaration of Conformity

Operating instructions. Switching amplifier DN0210 DN / / 2015

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

SR103AM. User Information for SR103AM. Correct Use

Redundancy unit CP-A RU

Transcription:

afety-monitoring module RB 207N 8 ppendix 8.1 Wiring examples...4 8.2 tart configuration...4 8.3 ensor configuration...5 8.4 ctuator configuration...5 8.5 Pin configuration (depending on the number of doors)...6 Operating instructions.............pages 1 to 8 Original 9 EU Declaration of conformity x.000 / 11.2017 / v.. - 101170115- / E / 2017-11-07 / E-Nr. 8306 Content 1 bout this document 1.1 Function...1 1.2 Target group: authorised qualified personnel....1 1.3 Explanation of the symbols used...1 1.4 ppropriate use...1 1.5 General safety instructions...1 1.6 Warning about misuse...2 1.7 Exclusion of liability...2 2 Product description 2.1 Ordering code...2 2.2 pecial versions....2 2.3 Purpose...2 2.4 Technical data...2 2.5 afety classification...3 3 Mounting 3.1 General mounting instructions...3 3.2 Dimensions...3 4 Electrical connection 4.1 General information for electrical connection....3 5 Operating principle and settings 5.1 Operating principle after the operating voltage is switched on...3 5.2 LED functions....3 5.3 Notes...4 6 et-up and maintenance 6.1 Functional testing....4 6.2 Maintenance...4 7 Disassembly and disposal 7.1 Disassembly....4 7.2 Disposal...4 1. bout this document 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety-monitoring module. The operating instructions must be available in a legible condition and a complete version in the vicinity of the device. 1.2 Target group: authorised qualified personnel ll operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only. Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation. The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components. 1.3 Explanation of the symbols used Information, hint, note: This symbol is used for identifying useful additional information. Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine. 1.4 ppropriate use The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant. The safety-monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description". 1.5 General safety instructions The user must observe the safety instructions in this operating instructions manual, the country specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the chmersal catalogues or in the online catalogue on the Internet: www.schmersal.net. The information contained in this operating instructions manual is provided without liability and is subject to technical modifications. There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed. 1

afety-monitoring module 1.6 Warning about misuse In case of inadequate or improper use or manipulations of the safety-monitoring module, personal hazards or damage to machinery or plant components cannot be excluded. The relevant requirements of the standards IO 14119 and IO 13850 must be observed. 1.7 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories. For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device. The safety-monitoring module must only be used when the enclosure is closed, i.e. with the front cover fitted. 2. Product description 2.1 Ordering code This operating instructions manual applies to the following types: RB 207N Only if the information described in this operating instructions manual are realised correctly, the safety function and therefore the compliance with the Machinery Directive is maintained. 2.2 pecial versions For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version. 2.3 Purpose The safety-monitoring module for integration in safety circuits is designed for fitting in control cabinets. It is used for the safe evaluation of the signals of positive break position switches for safety functions or magnetic safety sensors on sliding, hinged and removable safety guards as well as emergency stop control devices. Up to 6 safety guards can be monitored by means of the E 207N safety-monitoring module. Design The safety-monitoring module has a multichannel structure. It includes safety relays with monitored positive action contacts. The NO contacts of the relays, which are wired in series, build the enabling contacts. 6 signalling outputs signal the position of the corresponding safety guard. The entire concept of the control system in which the safety component is integrated, must be validated to the relevant standards. RB 207N 2.4 Technical data General data: tandards: 60204-1, 60947-5-1 IO 13849-1, IEC 61508 Climate resistance: 60068-2-78 Mounting: snaps onto standard DIN rail to 60715 Terminal designations: 60947-1 Material of the housings: Plastic, glass-fibre reinforced thermoplastic, ventilated Material of the contacts: gcdo, self-cleaning, positive drive Weight: 300 g tart conditions: utomatic or start button Feedback circuit (Y/N): yes Pull-in delay for automatic start: typ. 120 ms Pull-in delay with reset button: typ. 30 ms Drop-out delay in case of emergency stop: typ. 20 ms / max. 35 ms Drop-out delay on "supply failure": On request Mechanical data: Connection type: crew connection Cable section: min. 0,25 mm² / max. 2,5 mm² Connecting cable: rigid or flexible Tightening torque for the terminals: 0.6 Nm With removable terminals (Y/N): yes Mechanical life: 10 million operations Electrical life: Derating curve available on request Resistance to shock: 10 g / 11 ms Resistance to vibrations to 60068-2-6: 10... 55 Hz, amplitude 0.35 mm mbient conditions: mbient temperature: 25 C +45 C torage and transport temperature: 40 C +85 C Protection class: Enclosure: IP40 Terminals: IP20 Clearance: IP54 ir clearances and creepage distances to IEC 60664-1: 4 kv/2 (basic insulation) EMC rating: to EMC Directive Electrical data: Contact resistance in new state: max. 100 mω Power consumption: max. 3.6 W / 6.6 V Rated operating voltage U e : 24 VDC 15% / +20%, residual ripple max. 10% Fuse rating for the operating voltage: - 24 V version: F1: internal electronic trip, tripping current > 1 ; reset after disconnection of the supply voltage Monitored inputs: Cross-wire detection (Y/N): Yes Wire breakage detection (Y/N): Yes Earth leakage detection (Y/N): Yes Number of NO contacts: 1 6 t. Number of NC contacts: 1 6 t. Cable length: 1,500 m with 1.5 mm², 2,500 m with 2.5 mm² Conduction resistance: max. 40 Ω Outputs: Number of safety contacts: 2 Number of auxiliary contacts: 1 Number of signalling outputs: 6 witching capacity of the safety contacts: 13-14 / 23-24: max. 250 V, 6 ohmic (inductive in case of appropriate protective wiring) Fuse rating of the safety contacts: 6.3 slow blow Utilisation category to 60947-5-1: C-15: 230 V / 6 DC-13: 24 V / 6 Dimensions H W D: 100 mm 45 mm 121 mm The data specified in this manual are applicable when the component is operated with rated operating voltage U e ±0%. 2

afety-monitoring module 2.5 afety classification tandards: IO 13849-1, IEC 61508 PL: up to e Control category: up to 3 DC: 99% (high) CCF: > 65 points PFH value: 2,00 10-8 /h IL: up to 3 ervice life: 20 years The PFH value of 2.00 10-8 /h applies to the combinations of contact load (current through enabling contacts) and number of switching cycles (n op/y ) mentioned in the table below. t 365 operating days per year and a 24-hours operation, this results in the below-mentioned switching cycle times (t cycle ) for the relay contacts. Diverging applications upon request. Contact load n op/y t cycle 3. Mounting 20 % 525,600 1.0 min 40 % 210,240 2.5 min 60 % 75,087 7.0 min 80 % 30,918 17.0 min 100 % 12,223 43.0 min 3.1 General mounting instructions Mounting: snaps onto standard DIN rails to 60715. nap the bottom of the enclosure slightly tilted forwards in the DIN rail and push up until it latches in position. To avoid EMC disturbances, the physical ambient and operational conditions at the place where the product is installed, must meet the provisions laid down in the paragraph "Electromagnetic Compatibility (EMC)" of 60204-1. 3.2 Dimensions Device dimensions (H/W/D): 100 x 45 x 121 mm 4. Electrical connection 4.1 General information for electrical connection s far as the electrical safety is concerned, the protection against unintentional contact of the connected and therefore electrically interconnected apparatus and the insulation of the feed cables must be designed for the highest voltage, which can occur in the device. 5. Operating principle and settings RB 207N 5.1 Operating principle after the operating voltage is switched on With the guard door closed or the emergency stop command devices unlocked, the enabling paths are closed as soon as the start button is pushed. During the start command, the falling edge is detected, when the contacts of the downstream relays acting on the feedback circuit are closed. If the safety guard is opened or the emergency-stop button is actuated, the enabling paths of the safety-monitoring module will open. The machine is stopped and the LED K1 and K2 will go out. The corresponding signal output signals which guard was opened. Inputs 11/12-22/73/74; 31/32-42/83/84; 51/52-62/93/94 afety switches or emergency stop command devices with one NC and one NO contact must be connected to the inputs. If not all inputs are wired, a bridge must be established between x1 and x2 of the non-used input. tart button/feedback circuit X1/X2 Connect start button/feedback circuit to the inputs X1 and X2 according to the wiring diagram utomatic start X1-X3 The automatic start is programmed by connecting the feedback circuit to the terminals X1-X3. If no start button and no feedback circuit is used, a bridge must be established between X1 and X3. Outputs Enabling paths 13-14, 23-24: NO contacts for safety function ignalling output Y1-Y6 0 V safety guard open / no enabling signal 24 V safety guard closed / enabling signal uxiliary contact 31-32 Conditions of the enabling paths The signalling outputs and the auxiliary contact must not be integrated in the safety circuit. 5.2 LED functions K1: tatus channel 1 K2: tatus channel 2 U i : tatus internal operating voltage (LED is on, when the operating voltage on the terminals 1-2 is ON and the fuse has not been triggered) 13 1 23 31 11 X1 X2 X3 12 31 32 42 22 51 52 62 The electrical connection may only be carried out by authorised personnel in a de-energised condition. K1 Ui K2 RB 207N Wiring examples: see appendix 1 7374 83 93 Y1 Y3 Y5 14 24 32 84 94 Y2 Y4 Y6 Fig. 1 3

afety-monitoring module RB 207N 5.3 Notes ignalling outputs must not be used in safety circuits. Due to the operating principle of the electronic fuse, the customer must check that no hazard is caused by an unexpected restart in circuits without reset button (automatic reset). 6. et-up and maintenance 8. ppendix 8.1 Wiring examples Dual-channel control, shown for a guard door monitor; with two contacts, where at least one is a positive break contact; with external reset button J Relay outputs: uitable for 2-channel control, for increase in capacity or number of contacts by means of contactors or relays with positiveguided contacts. The control system recognises wire-breakage, earth faults and crosswire shorts in the monitoring circuit. = Feedback circuit 6.1 Functional testing The safety function of the safety-monitoring module must be tested. The following conditions must be previously checked and met: 1. Correct fixing 2. Check the integrity of the cable entry and connections 3. Check the safety-monitoring module's enclosure for damage. 4. Check the electrical function of the connected sensors and their influence on the safety-monitoring module and the downstream actuators 1 F1 J K KB X2 11 12 22 73 72 X3 X1 31 32 42 51 52 62 nsteuerlogik/ Control circuit K1 13 L1 23 31 K1 6.2 Maintenance regular visual inspection and functional test, including the following steps, is recommended: 1. Check the correct fixing of the safety-monitoring module 2. Check the cable for damages 3. Check electrical function If a manual functional check is necessary to detect a possible accumulation of faults, then this must take place during the intervals noted as follows: at least every month for PL e with category 3 or category 4 (according to IO 13849-1) or IL 3 with HFT (hardware fault tolerance) = 1 (according to IEC 62061); at least every 12 months for PL d with category 3 (according to IO 13489-1) or IL 2 with HFT (hardware fault tolerance) = 1 (according to IEC 62061). Damaged or defective components must be replaced. 7. Disassembly and disposal 7.1 Disassembly The safety-monitoring module must be disassembled in a de-energised condition only. Push up the bottom of the enclosure and hang out slightly tilted forwards. 7.2 Disposal The safety-monitoring module must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations. UB 2 Fig. 2 Ui 8.2 tart configuration K1 K2 Y1 Y2 Y3 Y4 Y5 Y6 K K2 14 KB 24 32 External reset button (non-monitored start) (see Fig. 3) The external reset button is integrated in the feedback circuit in series. The manual start or the activation of the module occurs when the button is pressed (not when it is released!). utomatic start (see Fig. 4) The automatic start is programmed by connecting the feedback circuit to the terminals X1-X3. If the feedback circuit is not required, establish a bridge. Caution: Not admitted without additional measure due to the risk of gaining access by stepping behind! When the RB 207N safety-monitoring module is used with the operating mode "utomatic start", an automatic restart after a shutdown in case of emergency must be prevented by the upstream control to 60204-1 paragraph 9.2.5.4.2. Due to the operating principle of the electronic fuse, the customer must check that no hazard is caused by an unexpected restart in circuits without reset button (automatic reset). N K2 X1 X1 J X2 X3 Fig. 3 Fig. 4 4

afety-monitoring module 8.3 ensor configuration Dual-channel emergency stop circuit with command devices to IO 13850 and 60947-5-5 (Fig. 5) Dual-channel guard door monitoring circuit with interlocking device to IO 14119 (see Fig. 5) Dual-channel control of magnetic safety switches according to 60947-5-3 (see Fig. 5) The control system recognises wire breakage and earth faults in the control circuit. Cross-wire shorts between the control circuits are detected. Category 3 PL e to IO 13849-1 possible. To control the risk of error accumulation, which is especially required in category 3 PL e, we recommend regularly checking the circuit by means of a start-up test EMERGCY TOP Door switch Magnetic reed switches 11 73 12 74 31 83 11 73 22 74 31 83 11 73 12 74 31 83 11 73 22 74 31 83 11 73 12 74 31 83 11 73 22 74 31 83 RB 207N When sensors with LED are wired in the control circuit (protective circuit), the following rated operating voltage must be observed and respected: 24 VDC with a max. tolerance of 5 %/+20 % Otherwise availability problems could occur, especially in series-wired sensors, where a voltage drop in the control circuit is triggered by LED's for instance. 8.4 ctuator configuration ingle-channel control (see Fig. 6) uitable for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. If the feedback circuit is not required, establish a bridge. = Feedback circuit Dual-channel control with feedback circuit (Fig. 7) uitable for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. If the feedback circuit is not required, establish a bridge. = Feedback circuit L1 X1 X2 13 L1 X1 X2 13 14 14 32 84 51 93 42 84 51 93 32 84 51 93 42 84 51 93 32 84 51 93 42 84 51 93 N Fig. 6 Fig. 7 N 52 94 62 94 52 94 62 94 52 94 62 94 Fig. 5 The connection of magnetic safety switches to the RB 207N safety-monitoring module is only admitted when the requirements of the standard 60 947-5-3 are observed. s the technical data are regarded, the following minimum requirements must be met: switching capacity: min. 240 mw switching voltage: min. 24 VDC switching current: min. 10 m For example, the following safety sensors meet the requirements: BN33-02z-2187, BN33-02zG-2187 BN260-02z, BN260-02zG BN260-02-01z, BN260-02-01zG 5

afety-monitoring module 8.5 Pin configuration (depending on the number of doors) (Unused sensor inputs must be accordingly bridged) Number of sensors to be monitored: 1; pin configuration: NC contacts 11/12 NO contacts 73/74 Bridges 11/22 31/32/42 51/52/62 Number of sensors to be monitored: 2; pin configuration: NC contacts 1 11/12 NC contacts 2 11/22 NO contacts 1 73/74 NO contacts 2 73/74 Bridges 31/32/42 51/52/62 Number of sensors to be monitored: 3; pin configuration: NC contacts 1 11/12 NC contacts 2 11/22 NC contacts 3 31/32 NO contacts 1 73/74 NO contacts 2 73/74 NO contacts 3 83/84 Bridges 31/42 51/52/62 Number of sensors to be monitored: 5; pin configuration: NC contacts 1 11/12 NC contacts 2 11/22 NC contacts 3 31/32 NC contacts 4 31/42 NC contacts 5 51/52 NO contacts 1 73/74 NO contacts 2 73/74 NO contacts 3 83/84 NO contacts 4 83/84 NO contacts 5 93/94 Bridges 51/62 Number of sensors to be monitored: 6; pin configuration: NC contacts 1 11/12 NC contacts 2 11/22 NC contacts 3 31/32 NC contacts 4 31/42 NC contacts 5 51/52 NC contacts 6 51/62 NO contacts 1 73/74 NO contacts 2 73/74 NO contacts 3 83/84 NO contacts 4 83/84 NO contacts 5 93/94 NO contacts 6 93/94 Bridges: none RB 207N Number of sensors to be monitored: 4; pin configuration: NC contacts 1 11/12 NC contacts 2 11/22 NC contacts 3 31/32 NC contacts 4 31/42 NO contacts 1 73/74 NO contacts 2 73/74 NO contacts 3 83/84 NO contacts 4 83/84 Bridges 51/52/62 6

afety-monitoring module RB 207N 9. EU Declaration of conformity EU Declaration of conformity Original K.. chmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. Name of the component: RB 207N Description of the component: afety-monitoring module for emergency stop circuits, guard door monitoring and magnetic safety switches Relevant Directives: Machinery Directive EMC-Directive RoH-Directive 2006/42/EC 2014/30/EU 2011/65/EU pplied standards: 60947-5-1:2004 + C:2005 + 1:2009, IO 13850:2015, IO 13849-1:2015, IO 13849-2:2012 Notified body, which approved the full quality assurance system, referred to in ppendix X, 2006/42/EC: TÜV Rheinland Industrie ervice GmbH lboinstr. 56, 12103 Berlin ID n : 0035 Person authorised for the compilation of the technical documentation: Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue: Wuppertal, 26 November 2017 RB 207 N-D- uthorised signature Philip chmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. 7

K.. chmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone: +49 - (0)2 02-64 74-0 Telefax: +49 - (0)2 02-64 74-1 00 E-Mail: info@schmersal.com Internet: http://www.schmersal.com