頤拓企業有限公司 TEL: TEKHNE TK-100 Dewpoint Transmitter. etorch Co., L. Users Manual. TEKHNE Corporation

Similar documents
Easidew Portable Hygrometer

Easidew Transmitter 2-Wire Dew-Point Transmitter

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

PURA HYGROMETER -120 C to -40 C Range 4-20 ma Sensor Output

Product Guide. Repeatable RH and temperature measurement for precise humidity control and validation

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

I Series Humidity/-temperature sensors with analogue output signals Technical Data Humidity Temperature

Optidew. High Performance Optical Dewpoint Transmitter. Users Guide

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Description. Type Product No. Measuring Range PMU-Type max. ambient temperature

TPE 1464 Series Pressure Transducer

selection of special materials is available to handle almost any fluid.

SensDev UG, based in Burgstaedt, Germany, is a Silicon Pressure Sensor supplier. Ranges are 50Pa to 4MPa, 10μL/s to 1000m³/h.

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Pressure transmitter/pressure switch PASCAL CS

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

PS600 series For viscous media or contamination

Advantages high measuring dynamics Nv (up to 1 : 1000) measuring range from 0.2 m/s. low measuring uncertainty, even at lowest flow velocities

Hygrophil HP, type / -20

Pressure transmitter/pressure switch PASCAL CS

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

Level sensor for monitoring the level of liquid media

Temposonics. R-Series POWERLINK. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

HygroClip M22 Series. 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL

H290 HUMIDITY TRANSMITTER INSTRUCTION MANUAL

TELEDYNE HASTINGS INSTRUMENTS

MODEL 245 / 345 High Range

Screw-in resistance thermometers with terminal head Form B

Flow measurement with sensors BZS25 at working temperatures up to +500 C optional with integrated and configurable transducer UFA

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

O 2 SENSORS Zirconium Dioxide (ZrO 2 ) Sensor and Interface Selection Guide

Digital pressure gauge Data Sheet: DMM2.431.R1.EN

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. C-Series Core Sensor, Models CS and CM Analog Outputs (Voltage/Current)

Humidity goes Digital

Users Manual Ocean Sensor Systems Wave Staff III

C-Flow Coriolis Mass Flow Meter

MODEL 245 / 345 DigiComp

I Series Humidity/-temperature sensors with analogue output signals Technical Data Humidity Temperature General data

NIR Moisture Analyzer KB-30

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Humidity goes Digital

Standard Temperature Sensors for Industrial Use

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

Type Differential pressure transducer

Model 332 Differential Pressure Transmitter

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM)

ProcessCalibrator Model CPH6000

Portable pressure calibrator Model CPH7600

D Issue A. Instruction Manual. Active Strain Gauge

SM300. Quick Start Guide Version 1.1. Soil Moisture and Temperature Sensor. Delta-T Devices Ltd

Mass Flow Meters & Controllers

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Temperature sensors TTM series. Miniature transmitters

Continuous level measurement Ultrasonic transducers

Threaded resistance thermometer Miniature design Model TR10-D

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

9823 Multifunction Calibrator Calibration Adjustment Procedure

DPM DPM MULTI PARAMETER - MULTI GAS MASS FLOW METER

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Electronic pressure switch with display For sanitary applications Model PSA-31

AI-102. IR Illuminator. Installation Guide. Rev IP Surveillance

Thermal Mass Flowmeter Sensyflow FMT200-D

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Class 220 KISTOCK. KT 220, KH 220 and KTT 220

Trace Moisture Transmitter DewPro MMY31

Level Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog

Flexible temperature transmitter and sensor

S 551 COMPRESSED AIR ANALYZER

Instruction Manual DR58 Brass Paddle Wheel Flow Meter

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

INSTALLATION INSTRUCTIONS

Linear Actuator Reference Manual

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

ISE5B. Series ZSE5B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

Electronic pressure switch with display Model PSD-4

SCADAPack Modbus multivariable transmitter

Installation & Operation Manual

Mini Probe. user manual. DM Models

Flow Measurement Applications

Beam Position Monitor For High Energy Particle Beams

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Transcription:

TEKHNE TK-100 Dewpoint Transmitter Users Manual TEKHNE Corporation et 49-20-308 Motoyoyogi-cho, Shibuya-ku, Tokyo, 151-0062, JAPAN Tel: +81-(0)3-3465 7721 Fax: +81-(0)3-3465 0568 Web Site: www.tekhne.co.jp E-mail: info@tekhne.co.jp

TABLE OF CONTENTS 1 PACKING Page 3 2 INSALLATION Page 3 2.1 Sensor Cable Connections Page 3 2.2 TK-100 Transmitter Installation Page 4 3 OPERATION Page 4 3.1. Background Gases Page 4 3.2. Sampling Page 4 4 MAINTENANCE Page 5 APPENDIX 1 Technical Specifications Page 6 2 Tekhne Corporation Contact Details Page 6 et 2

1. PACKING Thank you for purchasing TEKHNE TK-100 Dewpoint Transmitter. This Transmitter is delivered to you with complete set for continuous, on-line dew point measurement in a gas over an range of -100 to +20 C dew point. Please read this manual carefully for the operation of this TK-100 Transmitter. The TK-100 Transmitter contains the following standard components. At first, please check the followings are present in the packing box: TK-100 Transmitter Sensor cable Sensor block (option) And the following documents are also contained: Certificate of Calibration User manual (this paper) 2. INSTALLATION 2.1 Sensor Cable Connections The sensor cable should be connected to the monitor by its three terminated wires as shown in the following table. The sensor connector terminations are shown for reference. Function Power supply (+24 V) Output (4-20mA) Ground Red Wire Green Wire Black Wire Sensor Connector (Pre-wired) Pin 3 Pin 1 Pin (GND) et The standard cable length is 2 meter. Cable can be longer upon request from Tekhne Corporation. Otherwise, users can provide their own cable with the requirements listed under Technical Specifications, in Appendix 1. 3

2.2 TK-100 Transmitter Installation Remove the plastic protective cap from sensor before installation and retain for future use. The sensor has a 5/8"-18 UNF mounting thread and can be mounted either in the supplied flow-through sensor sampling block or directly inserted to a pipe or duct. The bonded seal provided is designed for operation at pressures up to 30 MPa when the sensor is fitted using the 5/8-18 UNF mounting thread and should be placed over the sensor before it is screwed into the sampling location. When connected to a stainless steel tubing system, the sensor and sampling block need no additional support. However, if PTFE tubing is used, it may be necessary to secure the sampling block using a suitable spring clip or clamp. Tekhne recommend a gas flow rate of 1 to 5 liter/minute when the sensor is mounted in the standard sampling block. For direct insertion applications, gas flow can be from static to 10 meter / second. 3. OPERATION Operation of the TK-100 Transmitter is very simple and easy. But for such simple and easy measurement, following precautions are important to protect the sensor from damage. 3.1 Background Gases The TK-100 Transmitter is suitable for measurement of the moisture content of a wide variety of gases. Corrosive gas to ceramics are suitable for the measurement by the TK-100 Transmitter. For other gases, please consult to Tekhne Corporation or its agent. 3.2 Sampling Representation of the measuring gas: In order that the TK-100 Transmitter is measuring the dew point which is representing the sampling gas, it is better the measurement point is as close as possible to the sampling point. Also, prevent liquid by never sampling from the bottom of a pipe. Dead Space in Sample Lines: In order to the fast and accurate measurement, reduce dead space for gases in sample lines. Such dead space causes moisture entrapment points. et Particulate Matters or Oil: Particulate matters or oil should be prevented, which will reduce response speed or, at worst, break the sensor. Using in-line filters is recommended in any case where the sensor is used. Tubing and Fittings: 4

Using stainless steel tubing and fittings are best for accurate and fast measurement. This is particularly important at low dew point since other materials have hygroscopic characteristics and adsorb moisture on the tube walls, slowing down response and giving false readings. Where stainless steel tubing is not practical, PTFE tubing are recommended. If any questions occurs, please consult with Tekhne Corporation for technical advice. 4. MAINTENANCE The TK-100 Transmitter is simple for the use. Maintenance necessary is confined to regular re-calibrations of the TK-100 transmitter. This work can only be done by exposure of the moisture sensor to sample gases of known moisture content. Calibration services are traceable to the National Physical Laboratory (UK), the National Institute of Standards and Technology (USA) are provided by Tekhne Corporation. In most applications, annual re-calibration ensures that the stated accuracy of the TK-100 Transmitter is maintained. Also Tekhne Corporation is offering the sensor tile change service. Even if the sensor tile is not operating while sensor body is working properly, it may be possible to recover by changing sensor tile. In such case, Tekhne Corporation is welcome to change sensor tiles with reasonable cost. Please consult this point with Tekhne Corporation or its agent. et 5

APPENDIX 1 TECHNICAL SPECIFICATIONS Type: Tekhne TK-100 Dewpoint Transmitter Calibration range: -100 to +20 C dew point. Power Supply: 12 to 28 V DC Output: 4-20 ma current source over the entire dew-point range Interchangeability: Fully interchangeable sensors. Accuracy: ±2.0 C dew point Temperature: Gas Temperature -20 to +60 C Storage Temperature -40 to +75 C Temperature coefficients: Temperature compensated. Operating pressure: 10-6 torr a vacuum to 30 MPa. Flow rate: 1 to 5 liter/minute mounted in standard sampling block 0 to 10 meter/second direct insertion Traceable certification: -90 to +20 C dew point traceable to the National Physical Laboratory; -75 to +20 C dew point traceable to NIST (USA) [For dew points < -90 C: Direct reference to a fundamental cooled mirror dew point meter] Weight: 0.15 Kg Sensor cable: Cable, screened twisted pair (x2), 7/0.2 type 1, common drain. Max length 1,000 meters. APPENDIX 2 Customer Service TEKHNE CORPORATION CONTACT DETAILS For advice on this, or any other Tekhne products, please feel free to contact us on any of the numbers below or alternatively visit our Web Site: www.tekhne.co.jp. Tekhne Corporation 49-20-308, Motoyoyogi-cho, Shibuya-ku, Tokyo 151-0062, JAPAN Tel: +81(3)3465 7721 Fax: +81(3)3465 0568 E-mail: info@tekhne.co.jp et 6