M7100 Pressure Transducer

Similar documents
U7100 Pressure Transducer

M5100 Heavy Industrial Pressure Transducer

FX1901 OEM Compression Load Cell

MS4525DO DESCRIPTION STANDARD RANGE (PSI)

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

FPS2800B12C4 Fluid Property Sensor Module

HIGH ACCURACY PRESSURE TRANSDUCERS

ED-21 Analog Output Series Magnetic Encoder

4515DO DESCRIPTION STANDARD RANGES(IN H20)

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

Industrial Pressure Transmitter

Electronic pressure sensors

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

ED-22 Analog Output Series Magnetic Encoder

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

Pressure transmitters OsiSense XMLP for industrial applications. Catalogue

TPE 1464 Series Pressure Transducer

USBDEVELKIT DEVELOPMENT KIT V3

LLN Representative photograph, actual product appearance may vary.

Model 8042 Submersible Accelerometer

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

D-Series Inclinometer

DPL/DPN-Series Inclinometer

Twist-lock style " or 2" Tri-Grip TM Fitting. PX429S15-015GV, shown smaller than actual size.

PRESSURE TRANSMITTER

Sample board for USB DEVELOPPER KIT

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

ETHERNET INTELLIGENT PRESSURE SCANNER

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

P499 Series Electronic Pressure Transducers

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

P027 Series Pressure Transducer Installation & Operation Manual

OEM Products for Large Volume Production:

Osisense XML. Electronic Pressure Sensors. Catalog

MS4515DO SPECIFICATIONS FEATURES APPLICATIONS

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

Model Number Structure

Installation Instructions Temperature transmitter TAA /00 06/2011

ME to 30W Single Output External Power Medical Series. Features

NOVOTURN Multiturn Sensor non-contacting Series RSM2800 analog

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Online data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Level sensor Stainless steel version Model RLT-1000, for industrial applications

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

WIRELESS SERIES Single or Dual Axis MEMS Inclinometer

CMP Applications. Features

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

CVN300-96P01A SERIES. Five Output. Special Features

4-20mA SERIES Single or Dual Axis MEMS Inclinometer

ZFM ZFM DIGITAL MASS FLOW METER

CMP Applications. Features

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

ORDERING INFORMATION # of Ports Pressure Type Device Name

Hall-Effect Paddle Joystick

Model Number Structure

Model Number Structure

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

Bulletin 871D Cylinder Position Inductive Style

Electronic pressure switch with display Model PSD-4

Inductive Cylinder Position Sensors

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Vert-X 05E 5V / % Ub. Application Access control systems Forklift

DI572 Digital Input Module

MPXHZ6130A, 15 to 130 kpa, Absolute, Integrated Pressure Sensor

TMT470L Temperature Transmitter

TMR1202. General Description. TMR Bipolar Switch. Features and Benefits. Applications

Safety Standards. Model Number: Unit Weight:

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

Safety Standards. Model Number:

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

XGCS491B201 Standalone panel smart antenna

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Differential Pressure Sensor

MEAS Model HTU21D DemoBoard USB Stick 4in1

PRODUCT SPECIFICATION

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

AI561 Analog Input Module

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Datasheet. ACF-10 Series AC/DC Power Module 10W

MHK5 SERIES PROFINET ABSOLUTE MULTI -TURN ENCODER

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

DC562, digital input/output module,

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

Transcription:

Pressure Transducer Performance standard to on and off highway engines and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless Steel wetted surfaces Medium to extremely high pressures CE Approval DESCRIPTION The pressure transducer from the Microfused line of MEAS sets a new price performance standard for demanding engine and vehicle, and industrial applications. This transducer is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam and corrosive fluids. The transducer pressure cavity is machined from a solid piece of 17-4 PH stainless steel. The standard version includes a 1/4 NPT pipe thread allowing a leak-proof, all metal sealed system. There are no O-rings or organics exposed to the pressure media and the durability is excellent. This automotive grade pressure transducer with stainless steel hermetic pressure ports and integral electrical connector boasts up to 43,000psi (3000Bar). The exceeds the latest industrial CE requirements including surge protection and is overvoltage protected to 16Vdc in both positive and reverse polarity. FEATURES APPLICATIONS Hermetic Pressure Ports On and Off Highway Engines and Vehicles Integral Electrical Connector HVAC Refrigeration Controls Survives High Vibration Compressors ±0.25% Accuracy Hydraulics Water Resistant 1M immersion Energy and Water Management STANDARD RANGES Range psig Range BarG 0 to 150 0 to 010 0 to 200 0 to 014 0 to 300 0 to 020 0 to 500 0 to 035 0 to 01K 0 to 070 0 to 03K 0 to 200 0 to 05K 0 to 350 0 to 10K 0 to 700 *For other pressure ranges, please consult factory. 1/5

Pressure Transducer PERFORMANCE SPECIFICATIONS Supply Voltage: 5V Ambient Temperature: 25 C (unless otherwise specified) PARAMETERS MIN TYP MAX UNITS NOTES Supply Voltage 4.75 5.00 5.25 V Supply Current 4 10 ma Ratiometric Output 0.5 4.5 V 1 Load Resistance 10 KΩ Accuracy (combined linearity, hysteresis & repeatability) -0.25 0.25 %Span 2 Total Error Band -1.0 1.0 % 3 Compensated Temperature -20 +85 C Operating Temperature -40 +125 C Storage Temperature -50 +125 C Insulation Resistance (500Vdc) 100 MΩ 4 Reverse Voltage 16 V Overvoltage Protection 16 V Short Circuit Protected Output Noise @ 1kHZ 10 mv Response Time (10% to 90%) 1.0 ms Long Term Stability -0.25 0.25 %Span/Year Frequency Response @ 1kHZ -3 db Notes 1. Ratiometric to supply voltage. 2. Best fit straight line. 3. Over the compensated temperature range. 4. Between sensor body to any pins of connector. Yes ENVIRONMENTAL SPECIFICATIONS Supply Voltage: 5V Ambient Temperature: 25 C (unless otherwise specified) PARAMETERS MIN TYP MAX UNITS NOTES Humidity (@40 C) 93 %RH Pressure Overload 2X Rated 5 Pressure Burst 5X Rated 6 Pressure Cycle 10M Cycles Media, Pressure Port Mechanical Vibration Mechanical Shock Package Protection Fluids compatible with 17-4PH Stainless Steel 20g, 10 ~ 2000Hz MIL-STD-810C, Method 514.2, Curve L Half-Sine, Peak: 50g, 11ms MIL-STD-202, Method 213B, Condition A IP67 (IEC60529) Notes 5. The maximum pressure that can be applied without changing the transducer s performance or accuracy. 6. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer. 2/5

Pressure Transducer Agency Approvals IEC61000-4-2 Electrostatic Discharge Immunity: 8kV Contact; 15kV Air; 3 Discharges; Class B. Unit survived IEC61000-4-3 EM Field Immunity: 100V/m, 80MHz~1GHz, 255 MHz steps, 3s Dwell. Max recorded output error <±1.5% Span IEC61000-4-4 Electrical Fast Transient Immunity: 1kV (Level 2), 120s, 5kHz Repetition Rate. Class B. Max recorded output error <±1.5% IEC61000-4-5 Surge: 1kV (Level 2), L-L 500V, L-E 1kV. Class B. Max recorded output error <±1.5% Span IEC61000-4-6 Conducted Immunity: 10V/140dB, 150kHz~80MHz (Level 3). Class B. Max recorded output error <±1.5% Span IEC61000-4-9 Pulsed Magnetic Field Immunity: 100A/m (Level 3). Class B. Max recorded output error <±1.5% Span IEC55022 Emission: Class A, 40dB 30-220MHz, 47dB 230MHz-1GHz Pressure Port Options Dim A (inches) [mm] Recommended Tightening Torque (Nm) 2 = 1/4-19 BSP Male.43[11.0] 30 4 = 7-16-20 UNF Male SAE J514, O-Ring Buna-N 70SH-904, ID8.92mm x W1.83mm.36[9.1] 19 5 = 1/4-18 NPT.56[14.2] 34 6 = 1/8-27 NPT.38[9.7] 16 P = 7/16-20UNF Female w/ Integral Valve Depressor.54[13.7] 19 Q = M10 x 1.0mm Male.38[9.6] 10 Others available upon request 3/5

Pressure Transducer DIMENSIONS 4/5

Pressure Transducer ORDERING INFORMATION M7138-300PG-200000 Specials (nnnn = Custom Drawing) Port Material (0 = 17-4PH SST) Pressure Port (See Pressure Port Options Table) Type (G = Gage) Pressure Range (See Pressure Range Table) Connection (7 = AMP Connector, 8 = Sumitomo Connector HV040, 9 = Packard Connector [Supply; PIN B]) Output (3 = 0.5-4.5V) Model NORTH AMERICA EUROPE ASIA Measurement Specialties 45738 Northport Loop West Fremont, CA 94538 Tel: 1-800-767-1888 Fax: 1-510-498-1578 Measurement Specialties (Europe), Ltd. 26 Rue des Dames 78340 Les Clayes-sous-Bois, France Tel: +33 (0) 130 79 33 00 Fax: +33 (0) 134 81 03 59 sales@sensorway.cn The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. 5/5