Introduction Circuit Protection

Similar documents
9926 Series Branch Rated Circuit Breakers AC Version

Introduction Electronic Circuit Protection ESX10-T

Circuit and Surge Protection Protection Solutions Catalog. North America

Overvoltage Protection

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Thermal-Magnetic Circuit Breaker 4220-T...

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Thermal-Magnetic Circuit Breaker 2216-S

1492-SP Supplementary Protectors

Supplementary Circuit Protectors Type GSB63

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

IELR Rail-Mount Series Magnetic Circuit Protectors

Module 18plus. Description. 18plus

Jtec 10kA Miniature Circuit Breaker

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Allen-Bradley 1492-RCDA4A40

Time Delay Values (E-Series)

PERCENT OF RATED CURRENT

Magnetic and Hydraulic-Magnetic Circuit Breaker

TeSys IEC Contactors and Overload Relays

IELR Series

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

60103 Circuit Breaker

Section 4 Ground-Fault Protection Devices

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Ihr autorisierter Distributor: Neumüller Elektronik GmbH

Supplemental Protectors

E-STOP relays, safety gate monitors

MULTI 9 System Catalog

E-Series General Specifications

UL 489 DIN Rail Miniature Circuit Breakers

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Product Guide. UL 1077 DIN Rail Supplementary Protectors

UL 489 DIN Rail Miniature Circuit Breakers

E-STOP relays, safety gate monitors

WMS SUPPLEMENTARY PROTECTORS

E-STOP relays, safety gate monitors

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

D-Series. Circuit Breaker

C-Series. Circuit Breaker

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

Selection Guide. Control Circuit and Load Protection

Safety Monitoring Relays

Selection Guide. Control Circuit and Load Protection

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Control Circuit and Load Protection Products

CS8 Industrial Control Relays

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

E-STOP relays, safety gate monitors

QF(26) - Series Miniature Circuit Breakers - High Rating ( A)

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

APL/UPL, 205/295 Series Magnetic Circuit Protectors

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Analog Voltage Combination Module

C-Series. Circuit Breaker

Advantages of a Full Featured 700 Series Relay

Miniature Circuit Breakers and Supplementary Protectors. Contents

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Electronic timer CT-ERS.21

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Communication & Networking

E-STOP relays, safety gate monitors

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Electronic timer CT-ARS.11

MINI-PS AC/10-15DC/8

Bulletin 1489 Circuit Breakers. Selection Guide

SITOP in the SIMATIC Design

Product Guide. UL 489 DIN rail miniature circuit breakers

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

E-STOP relay, safety gate monitor

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

20 General technical data XI/ON

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Mini Contactors & Overloads

Model Number Structure

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Electronic timer CT-ERD.12

E-STOP relay, safety gate monitor

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Click Desktop Kit. Click Desktop Kit

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Transcription:

Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short circuits. Each circuit breaker has the ability to be reset without the need to change components. All circuit breakers are available with an assortment of jumpers and marking tags. Circuit breakers in the 9926 Series are culus listed according to UL489 and CSA 22.2 No. 5.02, CE, VDE. The hydraulic magnetic trip mechanism offers,000a of interrupting capacity in 20V and 240V, 50/60Hz applications. The CB2200 Series feature integrated alarm contacts within a narrow profile, thereby allowing increased enclosure capacity. All of these circuit breakers demonstrate consistent reliability through 0% calibration and testing, and feature a touch safe design to prevent injury from accidental contact with live components. CB2200 Series The CB4200 Series of thermal magnetic circuit breakers feature a pushbutton style of trip reset. This reset provides a visual indication of status which allows for rapid troubleshooting. CB4200 Series The CB90 Series of thermal magnetic circuit breakers provide a rugged and industry-standard form factor (8 mm/pole). For supplemental circuit protection. CB90 Series 48

Branch Rated Circuit Breakers AC Version Circuit Breakers Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail culus listed according to UL489 CSA C22.2 No. 5.02, CE, VDE Ordering Data : (up to 20 VAC) : (up to 240 VAC) (amps) TS 35 Description (amps) TS 35 Description 0.5 99262500 QL--3-DM-KM-0.5 0.5 9926252000 QL-2-3-DM-KM-0.5 9926250 QL--3-DM-KM-0 992625200 QL-2-3-DM-KM-0 2 99262502 QL--3-DM-KM-02 2 9926252002 QL-2-3-DM-KM-02 3 99262503 QL--3-DM-KM-03 3 9926252003 QL-2-3-DM-KM-03 4 99262504 QL--3-DM-KM-04 4 9926252004 QL-2-3-DM-KM-04 5 99262505 QL--3-DM-KM-05 5 9926252005 QL-2-3-DM-KM-05 6 99262506 QL--3-DM-KM-06 6 9926252006 QL-2-3-DM-KM-06 7 99262507 QL--3-DM-KM-07 7 9926252007 QL-2-3-DM-KM-07 8 99262508 QL--3-DM-KM-08 8 9926252008 QL-2-3-DM-KM-08 992625 QL--3-DM-KM- 99262520 QL-2-3-DM-KM- 3 9926253 QL--3-DM-KM-3 3 992625203 QL-2-3-DM-KM-3 5 9926255 QL--3-DM-KM-5 5 992625205 QL-2-3-DM-KM-5 6 9926256 QL--3-DM-KM-6 6 992625206 QL-2-3-DM-KM-6 20 99262520 QL--3-DM-KM-20 20 9926252020 QL-2-3-DM-KM-20 25 99262525 QL--3-DM-KM-25 25 9926252025 QL-2-3-DM-KM-25 Voltage 20/240 VAC, 50/60Hz minimum 0.5A maximum 25A Interrupting capacity,000a Dielectric strength 500V, 50/60Hz 0MM Operating life 000 mechanical operations Operating temperature -40 +65 C Wire size* 0.5-5A: 4AWG min., AWG max. 20-25A: AWG min. 20 in.-lb Approval culus listed according to UL489 CSA C22.2 No. 5.02, CE, VDE Accessories Bus-bar ( pole, insulated, m) 67904 Bus-bar (2 pole, insulated, m) 67972 Bus-bar end cap, pole 67973 Bus-bar end cap, 2 pole 67974 Power lug, straight 67960 Power lug, 90 6796 Lock-out handle 6793 *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/7 marking tags. The part number for adhesive SchS2 is 720600000. Trip Curves Hydraulic Magnetic Typical time/current characteristics at 30ºC Sample trip characteristics - KM 25% 50% 200% 400% 600% 800% 00% minimum 5 8 4 0.7 0.09 0.007 0.005 (sec) maximum 300 90 28 4.5 0.6 0.4 (sec) Although the 9926 series uses a magnetic only trip mechanism, CSA testing indicates a trip characteristic similar to thermal magnetic trip mechanisms. No de-rating is required at elevated temperatures. Additional trip curves and amp ratings are available upon request. AC Version - dimensions in mm (in.) 7.4 (2.8) 28.5 (.2) 5 (0.2) 9 (0.75) 32 (.26) 45 (.77) 74 (2.9) 66 (2.6) 64.8 (2.55) AC version Trip Curve Tripping Time 00 0. Seconds Minutes0 0.0 0.00 0 5 30 50 200 300 400 500 7.9 (0.7) 57 (2.24) Operating Characteristics Curve 3 (0.5) Ambient Temperature 30 C 00 500 (%) Rated 2000 2500 3000 92.8 (3.65) 4000 5000 Trip Curve applies to the following part numbers where "XX" is the current rating: 9926252XX 99262522XX AC version Trip Curve Tripping Time 26 (.02) 3 (0.5) 00 0. Seconds Minutes0 0.0 0.00 0 5 25 50 200 300 400 500 Operating Characteristics Curve KM Ambient Temperature 30 C 00 500 (%) Rated 2000 2500 3000 4000 5000 49

Branch Rated Circuit Breakers AC Version with Contacts Circuit Breakers with Auxiliary switch, Trip alarm, Combination of both w/ Auxiliary Contact Trip (Alarm Contact) Combination (Auxiliary & Alarm Contact) AC voltages (20/240V) Single and double pole versions culus listed according to UL489 and C22.2 No. 5.02, CE, VDE Factory fitted auxiliary or trip alarm Compact 6.5mm width Attached to right hand side of circuit breaker Voltage 20/240 VAC, 50/60Hz minimum 0.5A maximum 25A Interrupting capacity,000a Dielectric strength 500V, 50/60Hz 0MM Operating life 000 mechanical operations Operating temperature -40 +65 C Wire size* 0.5-5A: 4AWG min., AWG max. 20-25A: AWG min. 20 in.-lb Approval culus listed according to UL489 and C22.2 No. 5.02, CE, VDE : Aux (up to 20 VAC) 9926260 QL-A--3-DM-KM- 2 99262602 QL-A--3-DM-KM-2 5 99262605 QL-A--3-DM-KM-5 992626 QL-A--3-DM-KM- 5 9926265 QL-A--3-DM-KM-5 20 99262620 QL-A--3-DM-KM-20 25 99262625 QL-A--3-DM-KM-25 w/ Auxiliary Contact : Trip (up to 20 VAC) 9926270 QL-T--3-DM-KM- 2 99262702 QL-T--3-DM-KM-2 5 99262705 QL-T--3-DM-KM-5 992627 QL-T--3-DM-KM- 5 9926275 QL-T--3-DM-KM-5 20 99262720 QL-T--3-DM-KM-20 25 99262725 QL-T--3-DM-KM-25 Trip (Alarm Contact) : Combo (up to 20 VAC) 9926280 QL-AT--3-DM-KM- 2 99262802 QL-AT--3-DM-KM-2 5 99262805 QL-AT--3-DM-KM-5 992628 QL-AT--3-DM-KM- 5 9926285 QL-AT--3-DM-KM-5 20 99262820 QL-AT--3-DM-KM-20 25 99262825 QL-AT--3-DM-KM-25 Combination (Auxiliary & Alarm Contact) *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/7 marking tags. The part number for adhesive SchS2 is 720600000. : Aux (up to 240 VAC) 992626200 QL-A-2-3-DM-KM- 2 9926262002 QL-A-2-3-DM-KM-2 5 9926262005 QL-A-2-3-DM-KM-5 99262620 QL-A-2-3-DM-KM- 5 992626205 QL-A-2-3-DM-KM-5 20 9926262020 QL-A-2-3-DM-KM-20 25 9926262025 QL-A-2-3-DM-KM-25 : Trip (up to 240 VAC) 992627200 QL-T-2-3-DM-KM- 2 9926272002 QL-T-2-3-DM-KM-2 5 9926272005 QL-T-2-3-DM-KM-5 99262720 QL-T-2-3-DM-KM- 5 992627205 QL-T-2-3-DM-KM-5 20 9926272020 QL-T-2-3-DM-KM-20 25 9926272025 QL-T-2-3-DM-KM-25 : Combo (up to 240 VAC) 992628200 QL-AT-2-3-DM-KM- 2 9926282002 QL-AT-2-3-DM-KM-2 5 9926282005 QL-AT-2-3-DM-KM-5 99262820 QL-AT-2-3-DM-KM- 5 992628205 QL-AT-2-3-DM-KM-5 20 9926282020 QL-AT-2-3-DM-KM-20 25 9926282025 QL-AT-2-3-DM-KM-25 AC version Trip Curve Dual Mount Dimensions in mm (in.) Trip Curves Hydraulic Magnetic Typical time/current characteristics at 30ºC Additional trip curves and amp ratings are available upon request. Tripping Time 00 0. 0.0 0.00 Seconds Minutes0 Operating Characteristics Curve KM Ambient Temperature 30 C 57.0 (2.24) 26.2 (.03) (N/O)6 (N/C)8 (C)5 3.3 (.23) (C) 2(N/C) 4(N/O) 2.3 (0.84) 32.9 (.3) 2. (0.83).7 (0.42) TRIP ALARM Q. CNECTORS 0 5 25 50 200 300 400 500 00 500 2000 2500 3000 4000 5000 2 (0.08) 0.5 (0.02) 5.5 (0.22) AUX SWITCH Q. CNECTORS 2.8 (0.) 0.5 (0.02) 7 (0.28) (%) Rated 50

Branch Rated Circuit Breakers DC Version Circuit Breakers Hydraulic Magnetic Single pole versions only U2 trip curve for general purpose applications 80 and 25 VDC Up to 60A Just 3 mm wide Mounts on 35mm DIN-rail UL 489A listed VDE (80 VDC) (25 VDC) Ordering Data : (80 VDC) 0.5 992625900 QY--3-DM-U2-0.5 99262590 QY--3-DM-U2-0 2 992625902 QY--3-DM-U2-02 3 992625903 QY--3-DM-U2-03 4 992625904 QY--3-DM-U2-04 5 992625905 QY--3-DM-U2-05 9926259 QY--3-DM-U2-5 99262595 QY--3-DM-U2-5 20 992625920 QY--3-DM-U2-20 25 992625925 QY--3-DM-U2-25 30 992625930 QY--3-DM-U2-30 35 992625935 QY--3-DM-U2-35 40 992625940 QY--3-DM-U2-40 45 992625945 QY--3-DM-U2-45 50 992625950 QY--3-DM-U2-50 60 992625960 QY--3-DM-U2-60 : (25 VDC) 99262580 QY--3-DM-U2-0-B 2 992625802 QY--3-DM-U2-02-B 3 992625803 QY--3-DM-U2-03-B 4 992625804 QY--3-DM-U2-04-B 5 992625805 QY--3-DM-U2-05-B 9926258 QY--3-DM-U2--B 5 99262585 QY--3-DM-U2-5-B 20 992625820 QY--3-DM-U2-20-B 25 992625825 QY--3-DM-U2-25-B 30 992625830 QY--3-DM-U2-30-B 35 992625835 QY--3-DM-U2-35-B 40 992625840 QY--3-DM-U2-40-B 45 992625845 QY--3-DM-U2-45-B 50 992625850 QY--3-DM-U2-50-B 60 992625860 QY--3-DM-U2-60-B Accessories DC version Trip Curve Dimensions in mm (in.) Bus-bar ( pole, insulated m) 67904 Bus bar end cap, pole 67973 Power lug, straight 67960 Power lug, 90 6796 Lock-out handle 6793 Trip Curves Hydraulic Magnetic Typical time/current characteristics at 30ºC Additional trip curves and amp ratings are available upon request. 74 (2.9) 66 (2.6) 7.9 (0.7) 3 (0.5) Voltage 80,25 VDC minimum 0.5 A maximum 60 A Interrupting capacity,000 A Dielectric strength 500 V, 50/60 Hz 0 MM Operating life 000 mechanical operations Operating temperature -40 +65 C Wire size* -5A: 4 AWG min., AWG max. 20-25A: AWG min. 20 in.-lb Approval UL 489A Listed, CE, VDE Tripping Time 00 0. Seconds Minutes0 0.0 0.00 0 5 30 50 200 300 400 500 Operating Characteristics Curve U2 DC (4% Ripple Factor) Ambient Temperature 30 C (%) Rated 00 500 2000 2500 3000 4000 5000 7.4 (2.8) 28.5 (.2) 5 (0.2) 9 (0.75) 32 (.26) 45 (.77) 64.8 (2.55) 57 (2.24) 92.8 (3.65) *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/7 marking tags. The part number for adhesive SchS2 is 720600000. 5

Supplemental Circuit Breakers Circuit Breakers Hydraulic Magnetic Triple Pole AC Voltages 277/480V Trip curve 2 for general purpose applications UL 77 recognized VDE approved and CE marked Just 3 mm wide Mounts to 35 mm DIN-rail Factory fitted auxiliary or trip alarm Single, double and triple pole versions Ordering Data Accessories : (up to 277 VAC) : (up to 480 VAC) : Triple Pole (up to 480 VAC) Rating Rating 99262550 QZ--3-D-2-0 992625250 QZ-2-3-D-2-0 99262535 QZ-3-3-D-2-2 992625502 QZ--3-D-2-02 2 9926252502 QZ-2-3-D-2-02 5 992625355 QZ-3-3-D-2-5 3 992625503 QZ--3-D-2-03 4 9926252504 QZ-2-3-D-2-04 20 9926253520 QZ-3-3-D-2-20 4 992625504 QZ--3-D-2-04 5 9926252505 QZ-2-3-D-2-05 25 9926253525 QZ-3-3-D-2-25 5 992625505 QZ--3-D-2-05 6 9926252506 QZ-2-3-D-2-06 30 9926253530 QZ-3-3-D-2-30 6 992625506 QZ--3-D-2-06 99262525 QZ-2-3-D-2-40 9926253540 QZ-3-3-D-2-40 8 992625508 QZ--3-D-2-08 5 992625255 QZ-2-3-D-2-5 50 9926253550 QZ-3-3-D-2-50 9926255 QZ--3-D-2-20 9926252520 QZ-2-3-D-2-20 60 9926253560 QZ-3-3-D-2-60 5 99262555 QZ--3-D-2-5 25 9926252525 QZ-2-3-D-2-25 20 992625520 QZ--3-D-2-20 30 9926252530 QZ-2-3-D-2-30 25 992625525 QZ--3-D-2-25 35 9926252535 QZ-2-3-D-2-35 35 992625535 QZ--3-D-2-35 40 9926252540 QZ-2-3-D-2-40 40 992625540 QZ--3-D-2-40 50 9926252550 QZ-2-3-D-2-50 50 992625550 QZ--3-D-2-50 60 9926252560 QZ-2-3-D-2-60 60 992625560 QZ--3-D-2-60 Supplemental dimensions in mm (in.) Bus bar ( pole, insulated m) 67904 Bus bar (2 pole, insulated m) 67972 Bus bar (3 pole, insulated m) 6797 Bus bar end cap, pole 67973 Bus bar end cap, 2 pole or 3 pole 67974 Power lug, straight 67960 Power lug, 90 6796 Lock-out handle 6793 22.5 (0.86) 65 (2.56) 60 (2.36) 25.9 (0.94) 45 (.77) 3 (0.5) 92.8 (3.65) 26 (.02) 39 (.54) 44 (.73) 3 (0.5) 3 (0.5) 5.0 (0.2) 63.8 (2.5) 73 (2.87) Voltage 277/480 VAC @ 50/60 Hz minimum 0.5 A maximum 60 A Interrupting capacity 5 ka @ 277/480 V, 5 ka @ 20 V, 5 ka @ 240 V Dielectric strength 500 V, 50/60 Hz 0 MM Operating life 000 mechanical operations Operating temperature -40 +65 C Wire size* -5A: 4 AWG min., AWG max. 20-25A: AWG min. 20 in.-lb Approval UL 77 Recognized, VDE (EN 60947-2) Approved, CSA C22.2 No. 235, CE Marked Supplemental Trip Curve Trip Curves Hydraulic Magnetic Typical time/current characteristics at 30ºC Additional trip curves and amp ratings are available upon request. Tripping Time 00 0. Seconds Minutes0 0.0 Operating Characteristics Curve 2 Ambient Temperature 30 C *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit).the SchS2 accepts DEK, WS and ESG 8/7 marking tags. The part number for adhesive SchS2 is 720600000. 0.00 0 5 30 50 200 300 400 500 (%) Rated 00 500 2000 2500 3000 4000 5000 curus recognized to UL77 and C22.2 No. 235 52

Supplemental Circuit Breakers with Contacts Circuit Breakers Auxiliary switch, Trip alarm, Combination of both w/ Auxiliary Contact Trip (Alarm Contact) Combination (Auxiliary & Alarm Contact) AC Voltages 277/480V Trip curve 2 for general purpose applications UL 77 recognized VDE approved and CE marked Just 3 mm wide Mounts to 35 mm DIN-rail Factory fitted auxiliary or trip alarm Single, double and triple pole versions Voltage 277/480 VAC @ 50/60 Hz minimum 0.5 A maximum 60 A Interrupting capacity 5 ka @ 277/480 V, 5 ka @ 20 V, 5 ka @ 240 V Dielectric strength 500 V, 50/60 Hz 0 MM Operating life 000 mechanical operations Operating temperature -40 +65 C Wire size* -5A: 4 AWG min., AWG max. 20-25A: AWG min. 20 in.-lb Approval UL 77 Recognized, VDE (EN 60947-2) : Aux (up to 277 VAC) 99262650 QZ-A--3-D-2-0 2 992626502 QZ-A--3-D-2-02 5 992626505 QZ-A--3-D-2-05 9926265 QZ-A--3-D-2-5 99262655 QZ-A--3-D-2-5 20 992626520 QZ-A--3-D-2-20 25 992626525 QZ-A--3-D-2-25 w/ Auxiliary Contact : Trip (up to 277 VAC) 99262750 QZ-T--3-D-2-0 2 992627502 QZ-T--3-D-2-02 5 992627505 QZ-T--3-D-2-05 9926275 QZ-T--3-D-2-5 99262755 QZ-T--3-D-2-5 20 992627520 QZ-T--3-D-2-20 25 992627525 QZ-T--3-D-2-25 Trip (Alarm Contact) : Combo (up to 277 VAC) 99262850 QZ-AT--3-D-2-0 2 992628502 QZ-AT--3-D-2-02 5 992628505 QZ-AT--3-D-2-05 9926285 QZ-AT--3-D-2-5 99262855 QZ-AT--3-D-2-5 20 992628520 QZ-AT--3-D-2-20 25 992628525 QZ-AT--3-D-2-25 Combination (Auxiliary & Alarm Contact) Approved, CSA C22.2 No. 235, CE Marked *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit). The SchS2 accepts DEK, WS and ESG 8/7 marking tags.the part number for adhesive SchS2 is 720600000. Supplemental Trip Curve Trip Curves Hydraulic Magnetic Typical time/current characteristics at 30ºC 00 Operating Characteristics Curve 2 : Aux (up to 480 VAC) 992626250 QZ-A-2-3-D-2-0 2 9926262502 QZ-A-2-3-D-2-02 5 9926262505 QZ-A-2-3-D-2-05 99262625 QZ-A-2-3-D-2-5 992626255 QZ-A-2-3-D-2-5 20 9926262520 QZ-A-2-3-D-2-20 25 9926262525 QZ-A-2-3-D-2-25 : Trip (up to 480 VAC) 992627250 QZ-T-2-3-D-2-0 2 9926272502 QZ-T-2-3-D-2-02 5 9926272505 QZ-T-2-3-D-2-05 99262725 QZ-T-2-3-D-2-5 992627255 QZ-T-2-3-D-2-5 20 9926272520 QZ-T-2-3-D-2-20 25 9926272525 QZ-T-2-3-D-2-25 : Combo (up to 480 VAC) 992628250 QZ-AT-2-3-D-2-0 2 9926282502 QZ-AT-2-3-D-2-02 5 9926282505 QZ-AT-2-3-D-2-05 99262825 QZ-AT-2-3-D-2-5 992628255 QZ-AT-2-3-D-2-5 20 9926282520 QZ-AT-2-3-D-2-20 25 9926282525 QZ-AT-2-3-D-2-25 Tripping Time 0. Seconds Minutes0 Ambient Temperature 30 C Triple Pole w/ Auxiliary Contact Triple Pole Trip ( Alarm Contact) Triple Pole Combination (Auxiliary & Alarm Contact) 0.0 0.00 0 5 30 50 200 300 400 500 (%) Rated 00 500 2000 2500 3000 4000 5000 curus recognized to UL77 and C22.2 No. 235 : Triple Pole Aux (up to 480 VAC) 992626350 QZ-A-3-3-D-2-0 2 9926263502 QZ-A-3-3-D-2-02 5 9926263505 QZ-A-3-3-D-2-05 99262635 QZ-A-3-3-D-2-5 992626355 QZ-A-3-3-D-2-5 20 9926263520 QZ-A-3-3-D-2-20 25 9926263525 QZ-A-3-3-D-2-25 : Triple Pole Trip (up to 480 VAC) 992627350 QZ-T-3-3-D-2-0 2 9926273502 QZ-T-3-3-D-2-02 5 9926273505 QZ-T-3-3-D-2-05 99262735 QZ-T-3-3-D-2-5 992627355 QZ-T-3-3-D-2-5 20 9926273520 QZ-T-3-3-D-2-20 25 9926273525 QZ-T-3-3-D-2-25 : Triple Pole Combo (up to 480 VAC) 992628350 QZ-AT-3-3-D-2-0 2 9926283502 QZ-AT-3-3-D-2-02 5 9926283505 QZ-AT-3-3-D-2-05 99262835 QZ-AT-3-3-D-2-5 992628355 QZ-AT-3-3-D-2-5 20 9926283520 QZ-AT-3-3-D-2-20 25 9926283525 QZ-AT-3-3-D-2-25 53

Supplemental Circuit Breakers GFCI Ground Fault Interrupt CE approved UL77 and UL53 recognized Small frame size (26mm wide) Single pole plus switched neutral ground leakage protection Trip point is unaffected by ambient temperature ratings up to 50A Trip indication (mid trip handle position) Trip curve 2 for general purpose applications GFCI Ordering Data : GFCI 5 9926295 QF7A2505 - CB W/GFI 992629 QF7A25 - CB W/GFI 5 9926295 QF7A255 - CB W/GFI 20 99262920 QF7A2520 - CB W/GFI 25 99262925 QF7A2525 - CB W/GFI 30 99262930 QF7A2530 - CB W/GFI 50 99262950 QF7A2550 - CB W/GFI GFCI dimensions in mm (in.) 73 (2.87) 65 (2.56) Standard Ampere (A) 5 to 50A Sensitivity (ma) 30 (CE) / 22 (UL) Number of Poles + N Equipment Ground Leakage/GFCS Rated Voltage (V) 230 (CE) / 240 (UL) Rated Interrupting/ 5 ka Withstand Capacity (ka) Weight (kg) 0.26 Trip Curve (standard) 2 Operating Temperature -40 to +65ºC Approval UL 77 and UL 53, CE AC version Trip Curve Trip Curves Hydraulic Magnetic Typical time/current characteristics at 30ºC Tripping Time 00 0. Seconds Minutes0 0.0 Operating Characteristics Curve 2 Ambient Temperature 30 C 93 (3.66) 82.4 (3.24) 26 (.02) 44 (.73) 68.8 (2.7) 7.8 (0.307) 57 (2.24) 6.4 (0.646) 8.0 (0.35) 0.00 0 5 30 50 200 300 400 500 00 500 2000 2500 3000 4000 5000 7.4 (2.8) 26 (.02) (%) Rated 35.7 (.406) 54

Mounting Options and Accessories Mounting Options If the product is not vertically mounted in the normal DIN-rail mounting orientation, a rating factor must be applied. Figure shows a diagram of the rating factor to apply. The published curves for these circuit breaker products are produced with the circuit breaker in the vertical mounting position. The rating factor only applies to the must hold and must trip points of the curve as the other parts (instantaneous trip point) stay largely unaffected. 95% 45 UP 93% HORIZ 45 UP 95% It is important to note that in environments that are exposed to a high degree of vibration, the cables that connect to the circuit breaker must be securely held in place, as the breaker is not designed to carry the weight of the cables. A maximum of 35N can be applied to the terminal area, in a direction perpendicular to the mounting axis. 0% VERT DOWN 45 HORIZ DOWN 45 VERT 0% 5% 5% Accessories 7% Rating 80A max. Voltage 500V max. Short Circuit Strength 25kA Bus bar ( pole, insulated m) 67904 Bus bar (2 pole, insulated m) 67972 Bus bar (3 pole, insulated m) 6797 Bus bar end cap, pole 67973 Bus bar end cap, 2 pole or 3 pole 67974 Rating 85A max. Wire Size AWG min., 4 AWG max. Dimensions A: 6 mm B: 32 mm Power lug, straight 67960 Power lug, 90 6796 Part Number Table - Example To order Circuit Breaker 9926250 Rating of.0 amp Internal Resistance per Pole of. ohms Trip Curve M, Medium (Standard) 99262500 Amperage "00" - 0.5A "0" - A "02" - 2A / "60" - 60A Trip Curves (s 5-9) "0" - Branch AC KM (Standard) "" - Branch AC OP (Instantaneous) "2" - Branch AC (Fast) "3" - Supplemental 9 (Slow) "4" - Branch 80VDC (Fast) "5" - Supplemental 2 (Standard) "6" - Branch 25VDC OP (Instantaneous) "7" - Branch 80VDC OP (Instantaneous) "8" - Branch 25VDC U2 (Standard) "9" - Branch 80VDC U2 (Standard) Poles Pole 2 Pole 3 Pole "5" - Base Breaker "6" - With Auxiliary Contact "7" - With Trip Alarm Contact "8" - Combo Aux/Trip Contact "9" - GFCI 99262400 Lock-out handle 6793 Amperage "00" - 0.5A "0" - A "02" - 2A / "60" - 60A Trip Curves ( 4) "0" - Supplemental (Fast) Poles Pole 2 Pole 3 Pole "4" - Base Breaker 55

CB4200 Series Supplemental Circuit Breakers Circuit Breakers Thermal Magnetic Rated from 0.05 to 6.0 amps Available in single or double pole configurations Features a tease free design to reduce contact damage Offers push button trip/reset function Trip free design means the breaker cannot be held closed against a fault Mounts on 32mm* or 35mm DIN-rail UL 77 recognized CB4200 Series CB4200 Series Ordering Data : : TS 35 TS 35 *For TS 32 Rail, *For TS 32 Rail, (amps) see adapter below (amps) see adapter below 0.05 924083500 0.05 924223500 0.08 924653500 0.08 924233500 0. 9473500 0. 920353500 0.2 9483500 0.2 924243500 0.3 92983500 0.3 924263500 0.4 924093500 0.4 924273500 0.5 903500 0.5 929583500 0.6 9243500 0.6 924283500 0.7 929563500 0.7 924293500 0.8 93500 0.8 929593500.0 9203500.0 92963500.2 9303500.2 929623500.3 92423500.3 92433500.4 92433500.4 924323500.5 9403500.5 929633500.8 92443500.8 924333500 2.0 9503500 2.0 929643500 2.5 9603500 2.5 929653500 3.0 9703500 3.0 929663500 3.5 92463500 3.5 924343500 4.0 94353500 4.0 92973500 4.5 92473500 4.5 924353500 5.0 9803500 5.0 929673500 5.5 97833500 5.5 924363500 6.0 9383500 6.0 924373500 6.5 920043500 6.5 924383500 7.0 9453500 7.0 924393500 8.0 93003500 8.0 94673500 9.0 9463500 9.0 924423500.0 9903500.0 929683500.0 92483500.0 924433500 2.0 97843500 2.0 924443500 3.0 92493500 3.0 924453500 4.0 97853500 4.0 924463500 5.0 92003500 5.0 929693500 6.0 92423500 6.0 924473500 Trip Curves Thermal Magnetic Typical time/current characteristics at 23ºC CB4200 Series M+ 0.05 to 7.5 A M+ 8 to 6 A *Adapter foot dimensions in mm (in.),000,000 30 C +23 C +55 C,000,000 30 C +23 C +55 C 0 0 20 (.787) 920000 TS32 adapter 0. 0. 0.0 0.0 0.00 0.8 2 3 4 6 8 20 30 50 70 0 times rated current 0.00 0.8 2 3 4 6 8 20 30 50 70 0 times rated current 56

CB4200 Series Supplemental Circuit Breakers CB4200 Series Internal Wiring Diagram Dimensions in mm CB4200 Series Internal Wiring Diagram Dimensions in mm Rated voltage & current Creepage resistance Dielectric strength Interrupting capacity (VDE 0660, Part, P-2) Interrupting capacity; 420 (UL 77/EN 60934 PC) UL CSA VDE Voltage AC 250 V, DC 65 V, 50/60 Hz 0.05 6 A AC 250 V, DC 65 V, 50/60 Hz 0.05 6 A AC 250 V, DC 65 V, 50/60 Hz 0.05 6 A PTI 600 to IEC 2 4,000 VAC; IEC 664 & 664 A > 0 MM (DC 500 V) 420- Maximum capacity 0.05 0.8 A Self-limiting 2 A 200 A 2.5 6 A 400 A Rated current Rated voltage Maximum capacity 0.05 2.0 A AC 250 V 200 A 2.0 6 A AC 250 V 200 A 20 A AC 25 V 400 A Typical life at 2 x rated current Shock Vibration Temperature range Corrosion Humidity Weight Wire size (UL) 5,000 operations 25 g ( ms) to IEC 68-2-27, Test Ea.2 Nm 5 g (57 to 500 Hz / ±0.38 mm, to 57 Hz) to IEC 68-2-6, Test Fc -30 C +55 C (-22 F +3 F) 96 hours at 5% salt spray, to IEC 68-2-, Test Ka 240 hours at 95% RH, to IEC 68-2-3, Test Ca 60 g per pole #20 8 AWG solid/0.5 6 mm 2 Accessories Jumpers Adapter foot (for TS 32 Rail) Marking Tags Note: Part numbers are shown for a single card of pre-printed tags numbered -50. Daisy Chain 50* Straight CQB** insulated Angled CQB** insulated Special print only Consecutive horizontal Consecutive vertical BDC 50 9970290000 CQB 2 9970560000 CQB 3 9970570000 CQB 4 9970580000 CQB 9970590000 CQB 2 9970600000 CQB 3 99706000 CQB 4 9970620000 CQB 9970630000 MCBAF/TS 32 920000 WS 8/5 MC 640750000*** DEK 5/5 047346000 DEK 5/5 047356000 Note: Resistive and inductive loads (0.05-6 A) *BDC will accommodate 20 A per pin, 20 A total **CQB will accommodate 8 A per pin, 8 A total; dedicated to 420 Series ***Please specify horizontal or vertical print when ordering. Standard quantity = 44 tags per card. 57

CB2200 Series Supplemental Circuit Breakers Circuit Breakers Thermal Magnetic CB2200 Series CB2200 Series CB2200 Series Triple Pole Rated from 0. to 32.0 amps Available in single, double and triple pole configurations Offers normally open (N/O) and normally closed (N/C) auxiliary contacts Lever-switch trip/reset function Mounts on 32mm or 35mm DIN-rail UL 77 recognized Ordering Data : * : : Triple Pole N/O Aux. N/O-N/C N/O-N/C (amps) (amps) (amps) 0. 99005 0. 9920003 0. 9930003 0.2 9920005 0.2 992020003 0.2 993020003 0.3 9930005 0.3 992030003 0.3 993030003 0.4 9940005 0.4 992040003 0.4 993040003 0.5 9950005 0.5 992050003 0.5 993050003 0.6 9960005 0.6 992060003 0.6 993060003 0.8 9980005 0.8 992080003 0.8 993080003.0 990005.0 9920003.0 9930003.5 9950005.5 99250003.5 99350003 2.0 99200005 2.0 992200003 2.0 993200003 2.5 99250005 2.5 992250003 2.5 993250003 3.0 99300005 3.0 992300003 3.0 993300003 4.0 99400005 4.0 992400003 4.0 993400003 5.0 99500005 5.0 992500003 5.0 993500003 6.0 99600005 6.0 992600003 6.0 993600003 8.0 99800005 8.0 992800003 8.0 993800003 9920005 99220003 99230003 2 99220005 2 992220003 2 992320003 5 99250005 5 992250003 5 992350003 6 99260005 6 992260003 6 992360003 8 99280005 8 992280003 8 992380003 20 992200005 20 9922200003 20 9923200003 25 992250005 32 992320005 *All part numbers with N/O Auxiliary Contacts on each pole when the main breaker contact is open (in the position) Ordering Data : : : Triple Pole All part numbers with N/C Auxiliary Contacts on each pole when the main breaker contact is open (in the position) (amps) (amps) (amps) 0. 99000 0. 9920000 0. 9930000 0.2 9920000 0.2 992020000 0.2 993020000 0.3 9930000 0.3 992030000 0.3 993030000 0.4 9940000 0.4 992040000 0.4 993040000 0.5 9950000 0.5 992050000 0.5 993050000 0.6 9960000 0.6 992060000 0.6 993060000 0.8 9980000 0.8 992080000 0.8 993080000.0 990000.0 9920000.0 9930000.5 9950000.5 99250000.5 99350000 2.0 99200000 2.0 992200000 2.0 993200000 2.5 99250000 2.5 992250000 2.5 993250000 3.0 99300000 3.0 992300000 3.0 993300000 4.0 99400000 4.0 992400000 4.0 993400000 5.0 99500000 5.0 992500000 5.0 993500000 6.0 99600000 6.0 992600000 6.0 993600000 8.0 99800000 8.0 992800000 8.0 993800000 9920000 99220000 99230000 2 99220000 2 992220000 2 992320000 5 99250000 5 992250000 5 992350000 6 99260000 6 992260000 6 992360000 8 99280000 8 992280000 8 992380000 20 992200000 20 9922200000 20 9923200000 25 992250000 25 9922250000 25 9923250000 32 992320000 32 9922320000 32 9923320000 58

T CB2200 Series Supplemental Circuit Breakers CB2200 Series Trip Curves Thermal Magnetic Typical time/current characteristics at 23ºC CB2200 Series,000,000 F 0. to 32 A 30 C +23 C +55 C 0 0. 0.0 0.00.8 2 3 4 6 8 20 30 50 70 0 times rated current -M 0. to 7.5 A,000,000 30 C AC +23 C DC +23 C +55 C 0 Dimensions in mm Rated voltage & current UL Voltage 277 / 480 VAC (50/60 Hz); 65 VDC 0. 32 A 0. DC CSA 277 / 480 VAC (50/60 Hz); 65 VDC 0. 32 A 0.0 AC VDE 250 / 45 VAC / 65 VDC 0. 32 A Auxiliary contacts 250 VAC / 65 VDC, A 0.00.8 2 3 4 6 8 20 30 50 70 0 times rated current Creepage resistance PTI 600 to IEC 2 Dielectric strength Interrupting capacity (VDE 0660, Part, P-2) 3,000 VAC; IEC 664 & 664 A > 0 MM (DC 500 V) Rated current Rated voltage Rupture capacity (3 times) 0.05 0.8 A 250 / 45 VAC 400 A,000,000 -M 8 to 32 A 30 C AC +23 C DC +23 C +55 C 6 32 A 250 / 45 VAC 800 A 0 Interrupting capacity (UL 77/EN 60934 PC) Rated current Rated voltage Max. rupture capacity (3 times) 0. 6 A 277 / 480 VAC 5000 A 20 32 A 277 / 480 VAC 2000 A 0. 32 A 65 VDC 2000 A 0. DC Typical life at 2 x rated current Shock Vibration Temperature range Corrosion Humidity Weight Wire size (UL) Nm (lb. in.) Accessories Jumpers Daisy Chain 50 Busbars 5,000 operations 25 g ( ms) to IEC 68-2-27, Test Ea 0.6 (5.3) Auxiliary contact: 0.5 (4.4) 5 g (57 to 500 Hz / ±0.38 mm, to 57 Hz) to IEC 68-2-6, Test Fc -30 +60 C (-22 F +40 F) 96 hours at 5% salt spray, to IEC 68-2-, Test Ka 240 hours at 95% RH, to IEC 68-2-3, Test Ca Approximately 60 g per pole max 6 mm 2 8 AWG max.5 mm 2 4 AWG (Aux. contact) BDC 50, 20 A maximum 9970290000 pole (CB2200) 99865000 2 pole (CB2200) 9987360000 0.0,000,000 0 0. AC 0.00.8 2 3 4 6 8 20 30 50 70 0 times rated current -T 0. to 7.5 A 30 C +23 C +55 C 0.0 Marking Tags 2 3 4 5 6 Note: Part numbers shown are for a single card of pre-printed tags numbered -50. Special print only Consecutive horizontal Consecutive vertical DEK 5/6 0490360000* DEK 5/6 046866000 DEK 5/6 046876000 0.00.8 2 3 4 6 8 20 30 50 70 0 times rated current -T 8 to 32 A Note: Resistive and inductive loads (0.05-6 A) *Please specify horizontal or vertical print when ordering.,000,000 30 C +23 C +55 C 0 0. 0.0 0.00.8 2 3 4 6 8 20 30 50 70 0 times rated current 59

CB90 Series Supplemental Circuit Breakers Circuit Breakers Thermal Magnetic CB90 Series CB90 Series CB90 Series Triple Pole Rated from 0.5 to 63 amps Available in single, double and triple pole configurations Optional auxiliary contacts Mounts on 35mm DIN-rail UL and CSA approvals CSA 277 VAC ( pole) or 480 VAC (2 and 3 pole) 50 VDC (0.5 A to 50 A) pole VDC (0.5 A to 50 A) 2 pole Ordering Data : : : Triple Pole (amps) (amps) (amps) 0.5 9925350000 0.5 9925650000 0.5 99258000.0 9925360000.0 9925660000.0 9925820000 2.0 9925380000 2.0 9925680000 2.0 9925840000 3.0 9925390000 3.0 9925690000 3.0 9925850000 4.0 9925400000 4.0 9925700000 4.0 9925860000 6.0 99254000 6.0 99257000 6.0 9925870000.0 9925430000.0 9925730000.0 9925890000 3.0 9929820000 3.0 9929830000 3.0 9929840000 6 9925440000 6 9925740000 6 9925900000 20 9925450000 20 9925750000 20 99259000 25 9925460000 25 9925760000 25 9925920000 32 9925470000 32 9925770000 32 9925930000 40 9925480000 40 9925780000 40 9925940000 50 9925490000 50 9925790000 50 9925950000 63 9925500000 63 9925800000 63 9925960000 Trip Curves Thermal Magnetic Typical time/current characteristics at 23 C CB90 Series M 0.5 to 6 A M AC to 40 A M AC 63 A,000,000,000 23 C 23 C 23 C,000,000,000 0 0 0 0. 0. 0. 0.0 0.0 0.0 0.00 0.8 2 3 4 6 8 20 30 50 70 0 times rated current 0.00 0.8 2 3 4 6 8 20 30 50 70 0 times rated current 0.00 0.8 2 3 4 6 8 20 30 50 70 0 times rated current 60

CB90 Series Supplemental Circuit Breakers CB90 Series 45 59 pole 36 8 6 44 70 2 pole 3 pole 54 86 Dimensions in mm Internal Wiring Diagram Rated voltage & current UL 77 CSA C 22.2 No. 235 VDE Creepage resistance Interrupting capacity (UL 77/EN 609334 PC) pole Mechanical/Electrical endurance Shock Vibration Temperature range - operating Weight Strip length Auxiliary contact rating Wire size - #22 2 AWG Wire size 277 V ( pole) 480 V (2 and 3 pole) 50 VDC ( pole) VDC (2 pole) 277 V ( pole) 480 V (2 and 3 pole) 50 VDC ( pole) VDC (2 pole) PTI 250 to IEC 2 >0 MM at 500 VDC ratings Interrupting Rupture capacity (3X) Voltage 0.5...63 A,000 A (UL) 277 VAC/50 VDC 0.5...32 A 2,000 A (UL) 277 / 480 AC 0.5...63 A 6,000 A (UL) 50 VDC () pole 0.5...50 A 6,000 A (UL) VDC (2) poles 20,000/,000 20 g ( ms) 2 Nm 3 g ( to 55 Hz) -25 C...+55 C (-3 F to 3 F) pole (30 g); 2 pole (280 g); 3 pole (430 g) 2 mm Voltage AC 220/240 5 A AC 277 3 A DC 24 V 4 A DC 60 V A DC220 V 0.4 A #8 2 AWG (line); #8 3 AWG (load) 69 Auxiliary Contact Modules 5.8 9 9.4 80.6 44 44 5 45.2 Accessories Jumpers Auxiliary contacts SPDT Side/Middle 3 pole bus, x mm, buses (9) 3 phase groupings 80A/0A 9970330000 3 pole bus, 6 x 2 mm, buses (4) 3 phase groupings 20A/30A 9970340000 3 pole bus, 6 x mm, buses (9) 3 phase groupings 20A/30A 9970350000 pole bus, 2 x 2 mm, buses 2 breakers 80A/0A 9970360000 pole bus, 2 x 2 mm (insulated), buses 2 breakers 63A 999990000 Bus bar clamp 30A 9970370000 Auxiliary contacts 9970300000 Internal Auxiliary Wiring Diagram 4 2 Security hardware Lock out cover 9970380000 Marking Tags Adhesive label ETO /26, yellow (26 mm x mm) 68640687 6