Switch Board for communicator Alarm

Similar documents
INTERQUARTZ. Doorphone ID 201 Doorphone ID 202 Doorphone ID 204. User manual

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

GSM PAGER VT 21. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC,

RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK Read this manual carefully before you start the installation or programming

660/960 Installation Guide

LEITRONIC AG Swiss Security Systems

GSM GATE VT 10. version 5.4 and higher. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC, Issued on May 16, 2007

8848 GSM FWT (GATEWAY) USER S MANUAL

ALPHATECH TECHNOLOGIES s.r.o. Jeremenkova 88, Praha 4, Czech Republic FLOOR TALKER. User manual

Aristel AN1001 GSM FIXED WIRELESS TERMINAL MANUAL V4.2. This manual contains important information. Please read before using the equipment.

Aristel AN1001 GSM FIXED WIRELESS TERMINAL MANUAL V4.2. This manual contains important information. Please read before using the equipment.

2400 Series. Installation & Operations Manual. 42 Central Drive Farmingdale, NY

CAMit I Camera with built in Modem

HOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA

UP100-GSM. GSM based intercom and access control. Installation and user manual

8434 User's Guide. Display A built-in 2-line by 24-character display.

SC-688 GSM FWT USER S MANUAL

VP-8LVCT User s Manual First Edition. Copyright 2001, Eletech Enterprise Co. Ltd. All Rights Reserved.

GSM Voice Active Monitoring OTP-GSM89

GSM FIXED WIRELESS TERMINAL

ecoline GSM Adapter INSTALLATION AND APPLICATION MANUAL for module version v2.0 and higher Document version:

31B TRADITIONAL ANALOGUE TERMINALS - AASTRA 6700A RANGE

Voice Fax. User Manual

MT-350 Mobile Trunk. Operation Manual. PORTech Communications Inc.

GSM GATE VT 10. version 7.0 and higher. Installation manual. VARIANT plus, spol. s.r.o., U Obůrky 5, TŘEBÍČ. Issued on January 10, 2012

Blue Gate A Brave Installation guide V 2.4

Congratulations! Installation Connecting the telephone Features: Caller ID service Setting Clock (Date and Time)

TC1900 "QUICK TALK" RS-232 or Fiber Telephone Extender User's Manual

Advanced Codes Settings for the H650IVN

Aristel AN4004 GSM FIXED WIRELESS TERMINAL MANUAL V3.1. This manual contains important information. Please read before using the equipment.

Intercom User Manual v1.1

2 Channel POTS DIN Fiber Link System

STD Simple Telemetry Application. Owner s Manual

Installation Manual & User Instructions. MultiCom 500

LCD240-xHxx. INSTALLATION MANUAL LCD240 Horizontal Graphic LCD Display Device for Lifts. Part No.

GSM communicator GD-06 Allegro Complete manual

Axxess Phone Instructions (NOT ALL PHONES HAVE ALL FEATURES)

SMS Transceiver V3 User manual

Sutron Voice Modem Operation Manual

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

LEITRONIC AG Swiss Security Systems

Vehicle DC-DC 150W User Guide DCA 7

DT6I Series 2 INTERROGATABLE 6 CHANNEL TALKING DIALLER. INSTALLATION MANUAL 2 nd EDITION.

Installation Manual & User Instructions. MultiCom 100 / 500

EA-GSM-Interface-GB.odt

Customer Interface Publication: KCH CIP001. Public Switched Telephone Network (PSTN) Technical Characteristics of the Single Analogue Line Interface

D2112 Keypad Diagnostics

PSTN-GSM Line Converter

LX8 emfone. Installation and Configuration. TVL No. 336 Issue No. 1 03/10/2011

WellGate 2504 ( 4-FXS ) and WellGate 2540 (4-FXO gateway) in Peer to Peer mode with Hotline by port to port application.

4 Channel POTS Fiber Link Card System

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01

Installation & Operations Manual

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

USER S MANUAL. Etross Printed for th edition

MICHIGAN STATE UNIVERSITY 3904 TELEPHONE OVERVIEW

Installation Manual & User Instructions

Technical data. General specifications. Indicators/operating means

ALCATEL 2315 USER GUIDE

Version 4.0. User Guide of Plantyst Box

CORDLESS ANSWERING SYSTEM TELEPHONE 7620

USER MANUAL. SAILOR 500/250 FleetBroadband

2 Channel POTS with I/O DIN Fiber Link System

DIGITAL ENHANCED CORDLESS TELEPHONE with Caller ID Function CL-3350 INF USER' S MANUAL

This document is available at BATTERY USAGE APPLICATION NOTES. For STEPPII-55/56 & STEPPII-55/56-LT

ULYDOR BY KALIKA (PBX

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

ILLUSTRATION. Base station. Mains power supply / line LED. Earpiece. Display. SOS key. Memory key. On/Off line key. Redial key

Ultrasonic sensors Discrete output Analog output

SERVICE MANUAL MODEL SSP-561-X-ADA

ID-Manager. PC program for Windows 98 and later versions of Windows. User manual for ID Manager

TABLE OF CONTENTS Introduction: Default Operation and Remote Programming Programming Receptionist Extensions Installing CallExtend

Silvertel. Ag Features. 2. Description. Compliant with PoH and IEEE802.3at Type 1(af) & Type 2. Small SIL package size 50.

TOA INTERCOM SYSTEM TELEPHONE LINE INTERFACE

GSM SECURITY AND CONTROL SYSTEM ESIM021

DMX-CFG-USB Cables (A2/ACE/K117/K23) Stepper Driver Configurator with USB 2.0 Communication

Guangdong Be-tech Security Systems Limited. Elevator Control Manual Instruction. Version 2013 Page1 total 22

Instruction Manual. Hidden CCD Camera VK-1321/PIR (B&W), VKC-1338/PIR (Colour)

Cisco 8841 & 8851 IP Phone Quick Reference V 1.2

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

Data sheet CPU 115 (115-6BL02)

Installation manual. FVK 842 vox Plus

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

INSTALLATION AND USE INSTRUCTIONS

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

RTG-3 2-Tone RETURN PATH TEST GENERATOR

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

rev mobile device to remotly control your home 2010 Cybrotech Ltd

INTERFACE TELEFÓNICO

Model SFS01-V2 IMPORTANT! MULTI-ATTEMPT AUTOMATIC ENGINE SMART SWITCH

FWT-8818 GSM Gateway USER S MANUAL

UP200-GSM Intercom and access control unit operating on mobile GSM network

Analog DECT Phone AGR-8206-SMK. Quick Installation Guide V 1.01

Transportation Solutions. Audio Signal Transducer

AWG2300. USB Multifunction Arbitrary Waveform Generator SCICORE INSTRUMENTS, INC.

Operating & Programming Manual PBX Model: COX-308S / 416S / 432S

NTSC TOA's Digital Video Recorder series combine high reliability with all the advantages of scalable expansion flexibility.

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Renewable Energy. Getting Started With the LEGO Energy Meter

TIPS FOR YOUR COMFORT AND SAFETY 4 SUPPORTING DOCUMENTATION 4 ABOUT YOUR PHONE 5 CUSTOMIZING YOUR PHONE 7 CALL HANDLING FEATURES 7

Transcription:

Switch Board for communicator Alarm User Guide

1 Connection SwitchBoard Switch board is simply device for communication between machine room and lift cabin. 2 Wiring SwitchBoard SwitchBoard is connected between the telephone line and lift communicator (only two wires). For correct function, just more connect 12V or 24V DC. Power is independent of the polarity. Consumption is 10mA in an inactive state, at communication consumption is 300 ma at 12V and 180 ma at 24V.

3 Functions SwitchBoard So that SwitchBoard worked with connected communicators, they must have some programmable parameters. Switchboard can be used to connect one elevator communicator (single mode) or for 2 or 3 parallel connected Communicators (parallel mode). Single mode: In this mode, only two important parameters: disable parallel connection and call duration. These two parameters must be set in the SwitchBoard as well as in the lift communicator. It is also necessary for the correct function a set same character prolongation call duration and code for hanging communicator. Indication: Green LED 1 flashes, green button does not respond. Function: After picking up handset of the telephone is disconnected telephone line begins to ring and then lift communicator pick. Normal call progress. Whenever is allotted time to expire maximum call duration, so Switchboard automatically dial DTMF the prolongation character. If you hang up the phone, so to the communicator will send hanging code. Parallel mode: In this mode it is necessary to set the same parameters in the SwitchBoard and connected communicators. Without this, you can not synchronize operation. These are the parameters: 42 character prolongation, 43 hangup code, 45 activate parallel mode, 4 * constant time detection, 51 maximum call duration. Indication: Green LEDs light, green button switch address where do will be called. Switches in the order 1 / 2 / 3 / 1+2 / 1+2+3. Function: Select the address (by green button) where do will be called. After picking up handset of the telephone is disconnected telephone line begins to ring and parallel connected comunicators gradually pick up and Switchboard selects the desired communicator. Normal call progress. Whenever is allotted time to expire maximum call duration, so Switchboard automatically dial DTMF the prolongation character. If you hang up the phone, so to the communicator will send hanging code.

Red button: Red switch enables the possibility to connect your phone in the machine room with external line. This is mainly for safety reasons, to call for help (ambulance, fire brigade). If the switch is closed, so the external line is connected directly to the phone and communicators in the elevator is not working. Call from cabine to Machine room: From version V3.4 of firmware is possible call to the machine room. For call use not blocked BTN2. This Button has three function: 1. emergency call press BTN2 longer than time parameter 52 (2sec) 2. technical call press BTN2 longer than (time param. 52) x 8 (16sec) 3. cal to the machine room three times press button BTN2 (explain in picture) Picture explain how pressed button for successful call to the machine room. 4 Programming SwitchBoard SwitchBoard is possible programming only from PC, from program AlarmSet. Connector for PC has only 4 pins and we need use reduction between 4 pins connector and standard 10 pins programming connector. Programming is easy, in program AlarmSet we have settings for connected communicators and now we connect SwitchBoard, and write this parameters (without changes) to the SwitchBoard, so this is all. This setings we recommended save to the PC for next other possible future servicing. Programming SwitchBoard need if you want to maintain good cooperation with connected Alarm. Constants at the Alarm, which will be connected to the SwitchBoard, must mutually agree. Therefore, the following procedure is recommended after setting

parameters in Alarm connect via the reduction SwitchBoard and write the same parameters in SwitchBoard. Parameters affected thereby: 42 Character to prolong the call 43 Command to hang up communicator by phone 45 Activation parallel mode of communicators 4* Constant for parallel mode - time for receive DTMF address of communicator 51 Maximal call duration Only from version FW V2.0-2018 4.1 Easy to switch to Single mode / Parallel mode It can be done using the green button when the power is connected. The assumption is that the communicators and SwitchBoard have the same settings (see Chapter 4). Procedure: 1. Press and hold the green button 2. Connect the power supply 3. The middle green LED lights up (2) 4. Release button, middle LED (2) blinks and one of adjacent LEDs lights up 5. The left LED (1) lights up - means that the Single mode is now selected in SwitchBoard The right LED (3) lights up - means that the Parallel mode is now selected in the SwitchBoard 6. Press shortly green button to switch mode - the selected mode is signaled by the light of the adjacent LED 7. Long press the green button (hold until the middle LED (2) goes out) to exit this mode setting.

5 Technical parameters Parameter Value Conditions Power supply - voltage 12-24V DC, independent of polarity Power supply - current max. 0,30A 12V max. 0,18A 24V Public line current detection min. 8mA Uline > 15V Line current for telephone min. 25mA Line current for Alarm min. 40mA Insertion Loss public line - Alarm < 1dB 1KHz, 600ohms Insertion Loss Alarm - telephone < 3dB 1KHz, 600ohms Ring generator voltage min. 55Vp-p at 10mA load Ring generator waveform rectangle Flash (pulse dial 1) - pulse - space min. 80ms / max. 400ms min. 200ms Dimension in [mm] 112 x 65 x 22 Operation temperature - 20 to + 50 st

JR 2012-17 version V2.0 XII/05