SM200. Quick Start Guide Version 1.3. Soil Moisture Sensor. Delta-T Devices Ltd

Similar documents
SM300. Quick Start Guide Version 1.1. Soil Moisture and Temperature Sensor. Delta-T Devices Ltd

ML3 ThetaProbe. Quick Start Guide Version 1.0. Soil Moisture and Temperature Sensor. Delta-T Devices Ltd

SM150. Quick Start Guide Version 1. Soil Moisture Sensor. Delta-T Devices Ltd

SM150T. Quick Start Guide Version 2.0. Soil Moisture Sensor. Delta-T Devices Ltd

Irrigation Control. Quick Start Guide Version 2c. Using Soil Moisture Sensors. Delta-T Devices Ltd

GP1 Data Logger. Quick Start Guide v2.0. Delta-T Devices Ltd

DL6 Data Logger. Quick Start Guide Version 1.2. Delta-T Devices Ltd

RH and Air Temperature Sensor

SPN1 Sunshine Pyranometer

User Manual for the. SDI-12 Profile Probe. Type SDI PR2/4 and SDI PR2/6 PR2 SDI-12-UM-4.1. Delta-T Devices Ltd

User Manual for the. Moisture Meter. type HH2. Version 4.0. Delta-T Devices Ltd

User Manual for the. Temperature Sensors TEMP-UM-2.1. Delta-T Devices Ltd

BF5 Sunshine Sensor. Quick Start Guide version 1.0. Delta-T Devices Ltd

Soil Moisture Measurement

SKTS 200 Series Temperature Probes

NMEA Multiplexer Owner s Handbook. Document Number: Date: February 2005

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

HD HD [ GB ] Probes for soil volumetric water content measurement. Temperature. Humidity PART OF G H M GROUP TELEMETRIE & AUTOMATION

User Manual for the. M Enclosure for GP2. Type M-ENCL-B2. Delta-T Devices Ltd M-ENCL-B2 -UM-5.0

DeltaLINK 3 Release Notes

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

ECHO. User s Manual. Dielectric Aquameter. For Models EC-20 and EC-10. Version 1.4. Decagon Devices, Inc.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

GP2 Data Logger. and Controller. Advanced capabilities

RADIOMETER PHOTOMETER L-420 INSTRUCTION MANUAL

User Manual for the. PAR Quantum Sensor. type QS2 QS2-UM-1.0. Delta-T Devices Ltd

AC-43 Accelerometer. User Manual

GP2 Data Logger. and Controller. Advanced capabilities

FLOW MONITOR & TRANSMITTER

Operation Manual SuperDry Data Logger (SDDL)

E3B USER'S GUIDE. for QT310 / QT320 QProx IC evaluation and development Overview. Fast Start

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

Environdata FA ma Converter Guide

VE-53 Sensor Uniaxial / Triaxial Surface and Downhole Velocity Sensor. Operation Manual

User Manual for. GPRS Modem. Delta-T Devices Ltd GPRS-UM-3.0

FLS M9.06. ph/orp MONITOR

Flow Sensor SONOFLOW CO.55

Leak Sensor. TOYOKO KAGAKU CO., LTD. Kawasaki, Kanagawa, Japan

Accsense Wireless System. Temperature Monitor

DTY-EPS DTY-EPU. w e DTY-EPP- - w e. t y. q DTY-EPU PSU-BR DTY-EPP-CC- L DTY-EPS. ZD1 ZD4 Tr1 Tr4

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

S05-SM User s Manual (ZigBee HA Profile) Ver. 1.02

Quick Start Guide. 2MP 4X PTZ IP Camera O2P4X

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

F1000 User's Manual. (Version: V1.01)

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

I Series Humidity/-temperature sensors with analogue output signals Technical Data Humidity Temperature

GP2 Data Logger Controller Research-grade logger controller - capable of complex calculated measurements and advanced feed-back control

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Mini Probe. user manual. DM Models

Never Beaten by Seasons

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Signet Pressure Transmitter

OPERATION MANUAL (Web Site Downloaded only)

NIR Moisture Analyzer KB-30

TRIME-EZ /-EZC /-IT /-ITC

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Mercury Manual No. IM-M1000 Rev G

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

RS-WS-N01-TR Soil moisture temperature operation instruction (Type 485)

P1P Touchscreen Installation Guide

To be read before commencing Operation

StarFinder Aire User Manual

Installing Sentor. Hardware Installation

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

PROTIMETER. TimberMaster. Protimeter Moisture Meter (BLD5605, BLD5609, BLD5605-SW, BLD5609-SW) Instruction Manual. Amphenol.

User Manual for the. M Enclosure for DL2e. Type M-ENCL-B. Delta-T Devices Ltd

More Precision. eddyncdt // Eddy current sensors for displacement and position

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Digital Clamp-on Meter Instruction Manual

S2Tech srl Via Imperia, 28 Milano ITALY Tel: Fax:

COGNEX. Checker SensorView. Quick Reference Guide

VW2110 Vibrating Wire Readout Calibrator Manual

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

3000 series Premium Hall effect joysticks

User's Guide. Video Borescope. Model BR100

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

頤拓企業有限公司 TEL: TEKHNE TK-100 Dewpoint Transmitter. etorch Co., L. Users Manual. TEKHNE Corporation

AWP-24-3 Wave Height Gauge User's Guide

Earth Resistance and Resistivity Tester

VW2106 VW Readout Manual

VT-50. Linear Positioning Stage Reference Manual. S e r i e s. (Open and Closed Loop Versions)

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

SUM-40 OPERATING MANUAL. Ma0 DYNAMIC STRUCTURES AND MATERIALS, LLC REV


Vapor Monitor Interface Module

Removal and Installation8

9823 Multifunction Calibrator Calibration Adjustment Procedure

INSTALLATION INSTRUCTIONS:

C-POWER AC AUTOMATIC CONTROL

Field Handbook Supervision

Transcription:

SM200 Soil Moisture Sensor Quick Start Guide Version 1.3 Delta-T Devices Ltd

SM200 overview 3 HH2 1 Cables 4 Data Loggers 2 Installation 2005 Delta-T Devices Ltd Page 2

1 Cables and Accessories Power V+ Signal Ground HH2 cable Extension cables Logger cable Extension cables can be joined up to a recommended maximum of 55m. 1.1m 5m 10m 25m 5m bare end Align the connectors carefully before pushing parts together. Screw together firmly to ensure the connection is water-tight. Insertion rods are available for installing the SM200 in an augered hole. 2 Installation Surface installation and spot measurements Clear away any stones. Pre-form holes in very hard soils before insertion. Push the SM200 into the soil until the rods are fully inserted. Ensure good soil contact. Best results are achieved by inserting the SM200 horizontally. If you feel strong resistance when inserting the SM200, you have probably hit a stone. Stop, and re-insert at a new location. Installing at depth Auger a 45mm diameter hole. ~10 to vertical is recommended. Fit insertion rod to SM200 - remember to pass the cable through the insertion rod and fit the connector first. Push the SM200 into the soil until rods are fully inserted. Ensure good soil contact. Backfill around the insertion rod. Alternatively Dig a trench, and install horizontally (see overview diagram). 2005 Delta-T Devices Ltd Page 3

3 HH2 Meter Connect the SM200 to the HH2 meter. Press Esc to turn the meter on, and if necessary press again until the HH2 displays the start-up screen. Set the meter to read from an SM200: Press Set and scroll down to the Device option. Press Set again and scroll down to select SM200. Press Set to confirm this choice. Device: v SM200 Make sure the HH2 is correctly configured for your soil type: At the start-up screen, press Set and scroll down to the Soil Type option. Press Set again and scroll down to the appropriate soil type (use Mineral for sand, silt or clay soils or Organic for peaty soils) Press Set to confirm this choice. Soil Type: v Mineral Choose the units you want for displaying readings. At the start-up screen, press Set and scroll down to the Display option. Press Set again and scroll down to select units. Press Set to confirm this choice. Press Read to take a reading. SM200 Store? 20.3%vol Press Store to save or Esc to discard the reading. Remove the SM200 from the soil and move to a new location... If you have saved data, connect your HH2 to a PC and run HH2Read to retrieve the readings. 2005 Delta-T Devices Ltd Page 4

4 Data Loggers GP1 2 SM200s can be connected to each GP1 - the SM200 should be connected as a single-ended, powered sensor. These details illustrate connections for Channel1: SM200 wiring Colour GP1 terminal Power V+ Red CH1 (PWR) Signal White CH1 (+) Ground Shield CH1 (GND) and CH1 (-) Configure the GP1 by choosing SM200 from the sensor menu in PC DeltaLINK or Pocket DeltaLINK. For configuration details see the GP1 Quick Start Guide. DL6 Up to 6 SM200s can be connected to each DL6 with each sensor connected as a single-ended, powered sensor. These details illustrate connection to Channel1: SM200 wiring Colour DL6 terminal Power V+ Red V+ Signal White IN+ Ground Shield INand 0V Configure the DL6 by choosing SM200 from the sensor menu in DeltaLINK. For configuration details refer to the DL6 User Manual. 2005 Delta-T Devices Ltd Page 5

DL2e Up to 60 SM200s can be connected to each DL2e with each sensor connected as a single-ended, powered sensor. These details illustrate connection to Channel 58 using the LAC1 input card configured in 15-channel mode, and warm-up channel 63: SM200 wiring Colour DL2e terminal Power V+ Red 63 NO Signal White 58+ Ground Shield 58- and 61- Configure the DL2e by choosing one of the SM200 sensor codes from the LS2Win sensor library, according to your soil type. For configuration details see the DL2e User Manual. Other data loggers The SM200 should be connected as a single-ended, powered sensor. Configure the logger input as a voltage sensor, approximately 0 to 1.0 volts corresponding to ~0 to 60% water content see next section. The SM200 has been optimised for a 1 second warmup period (minimum period 200ms). It is recommended that the sensor is not powered continuously. 2005 Delta-T Devices Ltd Page 6

5 Convert SM200 voltages to soil moisture readings Note: The SM200 output is automatically converted to soil moisture when using an HH2 meter or Delta-T data loggers. Example Take a reading with the SM200 V = 0.294 volts either Convert the reading to ε using the polynomial or ε = 3.62 linearisation table below. Then convert ε to soil moisture, θ, using the soil θ = 24.0% calibration values (a 0, a 1 ). or (for mineral soil) Convert directly for mineral or organic soils θ = 24.0% Conversion to ε Polynomial (use for SM200 readings from 0 to 1.1 Volts) ε = 2 3 4 5 1.0 + 16.103V 38.725V + 60.881V 46.032V + 13.536V where V is the SM200 output in volts Linearisation table (use for SM200 readings from 0 to 1.2 Volts) V ε V ε V ε V ε V ε 0.000 1.011 0.120 2.461 0.260 3.442 0.820 5.936 1.150 7.661 0.030 1.447 0.150 2.718 0.310 3.700 0.960 6.586 1.200 8.039 0.060 1.832 0.180 2.946 0.400 4.105 1.040 6.991 1.220 8.264 0.090 2.168 0.220 3.211 0.600 4.953 1.100 7.333 1.800 9.000 Conversion from ε to Soil Moisture θ = ε a 0 a Soil moisture ( ) 1 a 0 a 1 Mineral 1.6 8.4 Organic 1.3 7.7 Use these generalised soil calibration values for mineral and organic soil types, or carry out a soilspecific calibration to derive your own values see SM200 User Manual. Multiply x100 to convert soil moisture from m 3.m -3 to % volumetric. Direct conversion for Mineral and Organic soils θ θ 2 3 4 mineral =.071 + 1.917V 4.61V + 7.248 5.48V + 1. 611 0 V 2 3 4 organic =.039 + 2.091V 5.029V + 7.907V 5.978V + 1. 758 0 V 5 5 2005 Delta-T Devices Ltd Page 7

6 Specifications Range and Notes Accuracy* ± 3 %vol 0 to 50 %vol Salinity errors ± 3.5 %vol 0 to 40 %vol, over Power requirement 5 to 14V 15mA typical 50 to 500 ms.m -1 (0.5 to 5 ds.m -1 ) 1 second warm-up recommended 200ms minimum Output signal 0 to 1.0V Nominal 0 to 60 %vol Environmental sealing IP68 Sensor buriable, sealed to IP68 Operating range -20 to +60 C Readings in frozen soil are not meaningful * Accuracy figures apply to calibration soils and over 0 to 60 C. Percentages quoted as %vol are % volumetric water content. 7 Care and Safety The rods of the SM200 are sharp in order to ease insertion. Care must be taken and handling precautions followed. Avoid touching the rods or exposing them to other sources of static damage. Keep the SM200 in its protective tube when not in use. Take care when attaching cables to ensure that the connectors are clean, undamaged and properly aligned before pushing the parts together. Screw together firmly to ensure the connection is water-tight. If the connector is damaged, apply a light smearing of silicon grease to maintain sealing. Do not pull the sensor out of the soil by its cable. If you feel strong resistance when inserting the SM200 into soil, it is likely you have encountered a stone. Stop pushing and re-insert at a new location. Notices All parts of the SM200 design and documentation are the exclusive property of Delta-T Devices and covered under international copyright law, 2005. Patent(s) pending. The SM200 product is CE compliant, conforming to EN61326:1997. Delta-T Devices Ltd 128 Low Road Burwell Cambridge CB5 0EJ England (UK) Tel: +44 1638 742922 Fax: +44 1638 743155 E-mail: sales@delta-t.co.uk Web: www.delta-t.co.uk