TORCH: A large-area detector for precision time-of-flight measurements at LHCb

Similar documents
Status of the TORCH time-of-flight detector

TORCH. A Cherenkov based Time of Flight detector. Maarten van Dijk On behalf of the TORCH collaboration

SiPMs for Čerenkov imaging

Development of scalable electronics for the TORCH time-of-flight detector

GEANT4 is used for simulating: RICH testbeam data, HCAL testbeam data. GAUSS Project: LHCb Simulation using GEANT4 with GAUDI.

The LHCb upgrade. Outline: Present LHCb detector and trigger LHCb upgrade main drivers Overview of the sub-detector modifications Conclusions

A proximity focusing RICH with time-of-flight capabilities

TORCH - Cherenkov and Time-of-Flight PID Detector for the LHCb upgrade at CERN. Klaus Föhl, CERN

Timing properties of MCP-PMT

Performance of the MRPC based Time Of Flight detector of ALICE at LHC

The LHCb Upgrade. LHCC open session 17 February Large Hadron Collider Physics (LHCP) Conference New York, 2-7 June 2014

Design of the TORCH detector A Cherenkov based Time-of-Flight system for particle identification. Maarten Willibrord Uriël van Dijk

Cherenkov Radiation. Doctoral Thesis. Rok Dolenec. Supervisor: Prof. Dr. Samo Korpar

First results from the LHCb Vertex Locator

for the DESY/ ECFA study detector

The design and performance of a prototype water Cherenkov optical time-projection chamber

Preparation for the test-beam and status of the ToF detector construction

ATLAS ITk Layout Design and Optimisation

Time and position resolution of high granularity, high counting rate MRPC for the inner zone of the CBM-TOF wall

10 psec Time-Of-Flight Counter

Tracking and flavour tagging selection in the ATLAS High Level Trigger

Single-Volume Scatter Camera: simulation results

Progress in FDIRC & TOF

arxiv: v1 [physics.ins-det] 13 Jan 2015

Using Photons Drift Time to Reconstruct Nuclear Processes and PET Event Topologies. Andrey Elagin University of Chicago

Validation of the front-end electronics and firmware for LHCb vertex locator.

MCP Photodetector Development at Argonne. Lei Xia ANL - HEP

Straw Detectors for the Large Hadron Collider. Dirk Wiedner

Time of CDF (II)

Course Updates. Reminders: 1) Assignment #12 due today. 2) Polarization, dispersion. 3) Last HW (#13 posted) due Monday, May 3rd

First LHCb measurement with data from the LHC Run 2

Electron and Photon Reconstruction and Identification with the ATLAS Detector

The Progress of TOF on BESIII

A New Segment Building Algorithm for the Cathode Strip Chambers in the CMS Experiment

ATLAS, CMS and LHCb Trigger systems for flavour physics

Full Offline Reconstruction in Real Time with the LHCb Detector

Extremely Fast Detector for 511 kev Gamma

b-jet identification at High Level Trigger in CMS

Delayline Detectors. Imaging Detection of Electrons, Ions & Photons with Picosecond Time Resolution. e - I +

PoS(EPS-HEP2017)492. Performance and recent developments of the real-time track reconstruction and alignment of the LHCb detector.

Muon Reconstruction and Identification in CMS

Upgrading the ATLAS Tile Calorimeter electronics

PoS(ACAT08)101. An Overview of the b-tagging Algorithms in the CMS Offline Software. Christophe Saout

Modules and Front-End Electronics Developments for the ATLAS ITk Strips Upgrade

The performance of the ATLAS Inner Detector Trigger Algorithms in pp collisions at the LHC

Variation of Refractive Index inside an Aerogel Block

ALICE tracking system

Integrated CMOS sensor technologies for the CLIC tracker

Development of planar microchannel plate photomultiplier at Argonne National Laboratory

Fast pattern recognition with the ATLAS L1Track trigger for the HL-LHC

THE PANDA BARREL DIRC DETECTOR

CMS Conference Report

Adding timing to the VELO

PoS(EPS-HEP2017)523. The CMS trigger in Run 2. Mia Tosi CERN

PoS(High-pT physics09)036

THE PANDA BARREL DIRC DETECTOR

Studies of the KS and KL lifetimes and

Forward Time-of-Flight Geometry for CLAS12

Real-time Analysis with the ALICE High Level Trigger.

CMS FPGA Based Tracklet Approach for L1 Track Finding

Performance of the GlueX Detector Systems

Plastic scintillator detector with the readout based on array of large-area SiPMs for the ND280/T2K upgrade and SHIP experiments

Charged Particle Tracking at Cornell: Gas Detectors and Event Reconstruction

arxiv:physics/ v1 [physics.ins-det] 18 Dec 1998

Beam test measurements of the Belle II vertex detector modules

Direct photon measurements in ALICE. Alexis Mas for the ALICE collaboration

TOF Electronics. J. Schambach University of Texas Review, BNL, 2 Aug 2007

Simulating the RF Shield for the VELO Upgrade

PoS(Baldin ISHEPP XXII)134

APPLICATIONS KEY FEATURES. High-speed intensified Camera Attachment

Expected Performances of the scintillator counters Time Of Flight system of the AMS-02 experiment

IEEE Proof Web Version

Scintillator-strip Plane Electronics

Construction of the Phase I upgrade of the CMS pixel detector

First Operational Experience from the LHCb Silicon Tracker

Velo readout board RB3. Common L1 board (ROB)

The GTPC Package: Tracking and Analysis Software for GEM TPCs

Tracking and Vertex reconstruction at LHCb for Run II

Level-1 Data Driver Card of the ATLAS New Small Wheel Upgrade Compatible with the Phase II 1 MHz Readout

Performance of the ATLAS Inner Detector at the LHC

Charged Particle Tracking at Cornell: Gas Detectors and Event Reconstruction

Production and Quality Assurance of Detector Modules for the LHCb Silicon Tracker

3d-Topological Reconstruction in Liquid Scintillator

PSEC-4: Review of Architecture, etc. Eric Oberla 27-oct-2012

Measurement of fragmentation cross-section of 400 MeV/u 12 C beam on thin targets

The CMS alignment challenge

Simulation Study for EUDET Pixel Beam Telescope using ILC Software

Tracking and compression techniques

arxiv:hep-ex/ v2 7 Aug 1995

PoS(IHEP-LHC-2011)002

SoLID GEM Detectors in US

Option G 1: Refraction

TPC digitization and track reconstruction: efficiency dependence on noise

Progress on G4 FDIRC Simulation. Doug Roberts University of Maryland

HLT Hadronic L0 Confirmation Matching VeLo tracks to L0 HCAL objects

Applying Machine Learning for bb-decay Identification

Klaus Dehmelt EIC Detector R&D Weekly Meeting November 28, 2011 GEM SIMULATION FRAMEWORK

PANDA EMC Trigger and Data Acquisition Algorithms Development

GEM TPC Anode Pad Shape Studies

CMS Alignement and Calibration workflows: lesson learned and future plans

Transcription:

TORCH: A large-area detector for precision time-of-flight measurements at LHCb Neville Harnew University of Oxford ON BEHALF OF THE LHCb RICH/TORCH COLLABORATION

Outline The LHCb upgrade TORCH concept & principles R&D commercial MCPs & customized readout electronics Conclusions and future 2

The LHCb Experiment LHCb is an experiment to the search for new physics in CP violation and rare decays of heavy flavours Optimized for the strongly forward peaked heavy quark production at the LHC Covers only ~4% of solid angle but captures ~40% of heavy-quark production cross section RICH-1 RICH-2 TORCH upgrade 3

The need for good PID : 2010 data Example of direct CP violation measurement (> 3s) observation Separate samples into B 0 and B 0 using particle identification from RICH CP violation B d 0 B s 0 4

Upgraded LHCb experiment & PID Plan to upgrade in 2017/18: LHCb will increase data by an order of magnitude (from 5 fb -1 50 fb -1 ) Major trigger upgrade necessary for higher luminosity read out complete experiment at 40 MHz to CPU farm (software trigger) Current PID is provided by 2 RICH detectors, 3 radiators : aerogel, C 4 F 10, CF 4 RICH system will be retained but with photodetectors replaced Aerogel is less effective at high lumi due to its low photon yield & high occupancy. Propose to replace the aerogel with time-of-flight based detector (TORCH) 5

TORCH concepts & principles (1) TORCH (Time Of internally Reflected CHerenkov light) TORCH will provide positive identification of kaons up to p ~ 10 GeV/c, i.e. below the K threshold in the C 4 F 10 gas of RICH-1 DTOF (p-k) = 35 ps at 10 GeV over ~10 m flight path aim for ~15 ps resolution per track Cherenkov light production is prompt use quartz as source of fast signal Cherenkov photons travel to the end of the bar by total internal reflection time their arrival 6

TORCH concepts & principles (2) For fast timing measurement, need to correct for the chromatic dispersion of quartz : refractive index given by n group = n phase l (dn phase /dl) Photons emitted with Cherenkov angle cos q C = 1/ b n phase Photons with different l emitted with different cos q C Measure Cherenkov emission angle at the top of the bar reconstruct path length of photon through quartz The wavelength of the photon can be determined by this construction Measure arrival time: (t t 0 ) = L n group /c 1 cm thickness of quartz produces ~ 50 detected photons/track (assuming a reasonable quantum efficiency of the photon detector) ~ 70 ps resolution required per detected photon 7

Angular measurement Need to measure angles of photons, so their path length can be reconstructed (see also Dr. J.Schwiening PANDA, Dr. K.Nishimura - Belle II ToP, this session) ~ 1 mrad precision required on the angles in both planes Coarse segmentation (~1cm) sufficient for the transverse direction (q x ) q z q z q x q c 8

Focusing system To measure the angle in the longitudinal direction (q z ) Use a focusing block Measure the position of photon on the photodetector plane Linear array of photon detectors - dimensions match the Planacon MCP from Photonis 9

TORCH modular design Dimension of quartz plane is ~ 5 6 m 2 (at z = 10 m) Unrealistic to cover with a single quartz plate evolve to modular layout 18 identical modules each 250 66 1 cm 3 ~ 300 litres of quartz in total MCP photon detectors on upper edge 18 11 = 198 units Each with 1024 pads 200k channels total 10

Photon detection Micro-channel plate (MCP) - Planacon XP85022 comes close to matching requirements. Currently available with 32 32 anode pads. Test result from K. Inami et al [RICH2010]: s(t) = 34.2 ± 0.4 ps photon e.g. ~10 mm pores Faceplate Photocathode Dual MCP photoelectron DV ~ 200V DV ~ 2000V Gain ~ 10 6 DV ~ 200V Anode Anode pad structure can in principle be customed: We require a layout of 8 128 in discussion with manufacturers (Photek, UK). Lifetime of MCP is an issue 11

TORCH R&D: in progress Photon detectors: evaluate performance of existing MCP devices : 8 8-channel MCPs (Burle Planacons) single photoelectron response, efficiency and time jitter design and development of suitable anode pad structure Develop readout electronics speed - 40 MHz rate, resolution, cross-talk Simulation detailed simulation of TORCH tagging performance Letter of Intent submitted to the CERN LHCC [CERN/LHCC 2011-001] 12

MCP tests time resolution experimental setup Synch Pulsed laser diode Start Stop Fast amplifier + CFD MCP Time-to- Amplitude Converter Light-tight box Multi- Channel Buffer 13

MCP tests experimental setup Single channel NIM electronics Dark box Planacon MCP Laser light source 14

Counts Planacon 8x8 : pulse height spectrum fit Run at gain ~ 5x10 5 e - Blue laser, μ~0.51 Fit according to Poisson distribution P m (0) e - m A s total 2p surface Gaussian pedestal P(0) and resolution functions P m P y m ( N ) m A 0 e 0 2 1 x - x 0-2 s 0 N m - m ( N ) e N! s N s N 1 N e - m N! 0 A N total s N 2p surface 100000000 10000000 1000000 100000 10000 1000 100 10 1 Eff ~88% 0 500 1000 1500 2000 2500 Channel number 15

Planacon 8x8 : time resolution distribution s~41.6 ps Back-scatter tail Time ps 16

MCP Connection Readout electronics Starting with 8-channel NINO chips and HPTDC (high resolution mode), developed for the ALICE TOF Jitter measured to be 14-20 ps RMS Test-beam studies foreseen for later this year Planacon Ext Clk 2 NINO chips Trigger NINO Hits HPTDC JTAG Clk Buf HPTDC JTAG FPGA JTAG Shared data bus Spartan 3AN SPI Flash NINO Hits HPTDC Control bus Gigabit Ethernet PHY SRAM / SDRAM Optional 17

Efficiency TORCH expected performance Simple simulation of the TORCH detector & interfaced to a full simulation of LHCb, plus pattern recognition Calculated Obtain a start time t 0 from the other tracks in the event originating from the primary vertex The intrinsic arrival time resolution per p.e. is 50 ps giving a total resolution per detected p.e. of 40 ps [MCP] 50 ps [intrinsic] 70 ps, as required Excellent particle ID performance achieved, up to and beyond 10 GeV/c (with some discrimination up to 20 GeV/c) LHCb Monte Carlo Track momentum GeV/c 18

Conclusions & future plans TORCH is a novel detector concept proposed for the upgrade of LHCb. Given a per-photon resolution of 70 ps, excellent K-p separation can be achieved up to 10 GeV/c and beyond (with TOF resolution of ~15 ps per track) R&D is in progress, starting with the photodetector and readout electronics Impact of the TORCH is under study with detailed simulation Letter of Intent for the LHCb upgrade already submitted; Technical Design Report in ~2 years time. 19

Spare slides from here on 20

PID calibration samples f K s L D from D* Samples allow PID calibrations in efficiency and purity to be evaluated with data 21

Synch Fanout MCP tests pulse height experimental setup Pulsed laser diode Optical fibre Shaping amplifier Light-tight box MCP Gate Scope Charge preamplifier Multi- Channel Buffer 22

Specifications of 8 8-channel MCPs XP85012/A1 MCP-PMT planacon 8x8 array, 5.9/6.5mm size/pitch 25um pore diameter, chevron type (2), 55% open-area ratio MCP gain up to 10 6 Large gaps: PC-MCPin: ~4mm MCPout-anode: ~4mm 53mmx53mm active area, 59mmx59mm total area -> 80% coverage ratio Total input active surface ratio 44% bialkali photocathode rise time 600ps, pulse width 1.8ns Photoni s-burle 23

TOF over 9.5m flight distance 24

Aerogel & high lumi running Flavour tagging (distinguishing B from B) is one of the primary requirements for low-momentum particle ID in LHCb (2 10 GeV) currently provided by aerogel 1 st Phase Upgrade 25

HPTDC-NINO Board status Board layout Layout completed, under final review Sourcing components for 14 boards 2 NINO chips 2 HPTDC chips FPGA 26

Readout electronics - general assembly drawing 4 boards connected to Planacon - 8x8 channels 27

Spread of arrival times 1 cm thickness of quartz is enough to produce ~ 50 detected photons/track (assuming a reasonable quantum efficiency of the photon detector) ~ 70 ps resolution required per detected photon However, spread of arrival times is much greater than this, due to different paths taken by photons in the bar 3 m Photon arrival time 25 ns 28

Effect of edges Reflection off the faces of plate is not a problem, as the photon angle in that direction (q z ) is measured via the focusing system In the other coordinate (x) position is measured rather than angle reflection off the sides of the plate gives ambiguities in the reconstructed photon path Only keep those solutions that give a physical Cherenkov angle only ~ 2 ambiguities on average Effect of the remaining ambiguities is simply to add a ~ flat background to reconstructed time distribution 29

Pattern recognition Event display illustrated for photons from 3 different tracks hitting plane 30