Three-dimensional dosimetry of small fields

Similar documents
Megan A. Wood, M.S. Under the direction of Larry DeWerd, Ph.D. University of Wisconsin Medical Radiation Research Center (UWMRRC)

Michael Speiser, Ph.D.

UNCOMPROMISING QUALITY

Air Kerma Strength Measurements and Monte Carlo based Dosimetric Characterization of a directional Pd 103 planar source array.

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

ELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Basics of treatment planning II

FAST, precise. qa software

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

Code of practice: Create a verification plan for OCTAVIUS Detector 729 in Philips Pinnacle³

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws.

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

Shielding factors for traditional safety glasses

Three-dimensional dosimetry of TomoTherapy by MRI-based polymer gel technique

S. Guru Prasad, Ph.D., DABR

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

Monte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

Transitioning from pencil beam to Monte Carlo for electron dose calculations

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

Output factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery system

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR

Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions

Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

Raising the Bar in IMRT QA

DUAL energy X-ray radiography [1] can be used to separate

GafChromic Protocol Multi-Channel Film Dosimetry + Gamma Map Analysis

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

CT vs. VolumeScope: image quality and dose comparison

Dynalog data tool for IMRT plan verification

Proton dose calculation algorithms and configuration data

TPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1

4 Measurement. and Analysis. 4.1 Overview and Underlying Principles 4-1

Introduction to Biomedical Imaging

Clinical implementation of photon beam flatness measurements to verify beam quality

Investigation of photon beam output factors for conformal radiation therapy Monte Carlo simulations and measurements

CBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Construction of Voxel-type Phantom Based on Computed Tomographic Data of RANDO Phantom for the Monte Carlo Simulations

Comparison of Two Phantoms for End-to-End SRS/SBRT Testing. Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center

87.55.K-, Gh, km, Ca. Agility, analytic model, Elekta, Monaco, Monte Carlo, virtual source

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm

Continuation Format Page

GPU Based Convolution/Superposition Dose Calculation

Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43

Implementation of a double Gaussian source model for the BEAMnrc Monte Carlo code and its influence on small fields dose distributions

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques

VALIDATION OF A MONTE CARLO DOSE CALCULATION ALGORITHM FOR CLINICAL ELECTRON BEAMS IN THE PRESENCE OF PHANTOMS WITH COMPLEX HETEROGENEITIES

PROVIDE A UNIFORM DOSE IN THE SMALL ANIMAL.

Effects of the difference in tube voltage of the CT scanner on. dose calculation

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Spectral analysis of non-stationary CT noise

Chapter 7 Feasibility Study for 3D Online Motion Compensation

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations

Goals. Scope/exclusions. Outline: follow outline of MPPG (plus rationale & some implementation experiences)

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Basic Radiation Oncology Physics

Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.

Monte Carlo investigation of collapsed versus rotated IMRT plan verification

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

THE SIMULATION OF THE 4 MV VARIAN LINAC WITH EXPERIMENTAL VALIDATION

ISOCS Characterization of Sodium Iodide Detectors for Gamma-Ray Spectrometry

Verification measurements of an emc algorithm using a 2D ion chamber array

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

Use of a commercial ion chamber detector array for the measurement of high spatial resolution photon beam profiles

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory

Dosimetric Analysis Report

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

8/7/2017. Disclosures. MECT Systems Overview and Quantitative Opportunities. Overview. Computed Tomography (CT) CT Numbers. Polyenergetic Acquisition

Machine and Physics Data Guide

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

15 Dose Calculation Algorithms

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

The MSKCC Approach to IMRT. Outline

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Influence of electron density spatial distribution and X-ray beam quality during CT simulation on dose calculation accuracy

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Quick Reference Datasheet For All RIT113 Packages

Room scatter effects in Total Skin Electron Irradiation: Monte Carlo simulation study

Source Model Tuning for a 6 MV Photon Beam used in Radiotherapy

2D DOSE MEASUREMENT USING A FLAT PANEL EPID

Facility Questionnaire PART I (General Information for 3DCRT and IMRT)

Initial Clinical Experience with 3D Surface Image Guidance

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code

Advanced Radiotherapy

Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms.

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

Anthropomorphic Verification of the Eclipse AAA Algorithm for Spine SBRT Treatments Involving Titanium Implants

Monitor Unit (MU) Calculation

Transcription:

Three-dimensional of small fields Travis J. McCaw Medical Radiation Research Center Department of Medical Physics University of Wisconsin, Madison, WI NCCAAPM 2013 Fall Meeting 10 October 2013 Medical Radiation Research Center

Outline 3D Fricke gel Polymer gel PRESAGE Small field Alfonso formalism Applications for 3D Radiochromic film stack dosimeter 2

Fricke gel Radiation-induced conversion of ferrous ions to ferric ions Different NMR relaxation rates permit MR readout Incorporate ferrous sulphate solution into organic gel matrix to measure spatial dose distribution Postexposure ionic diffusion introduces error High electrical conductivity strongly attenuates RF pulses during MR readout 3

Polymer gel Numerous variants BANG, MAGIC, PABIG, VIPAR Highly toxic acrylamide monomer Radiation-induced polymerization Alters NMR relaxation rates Produces optical change Inhibited by oxygen 4

PRESAGE Radiochromic plastic Optical contrast due to absorption No container required Reduced edge artifacts Courtesy of presage3d.com 5

Problems with small field How small is small? Field size Detector size Range of secondary electrons Source occlusion Breakdown of FWHM field size definition Reduced source output results in field size overestimation Loss of CPE with relatively large electron ranges Use of cavity theory Charged particle fluence perturbation by detector Dependent on energy and field size I. J. Das, G. X. Ding, and A. Ahnesjö, Med. Phys. 35, 206-215 (2008). 6

Alfonso formalism Proposed formalism for of small and composite fields Established pathways from conventional reference conditions to nonstandard fields R. Alfonso, P. Andreo, R. Capote, et al., Med. Phys. 35, 5179-5186 (2008). 7

Small-field polymer gel Compared OF and profiles measured with gel, PinPoint chamber, diode array and diamond detector Pros Tissue equivalence No fluence perturbation (gel is phantom and dosimeter) Good resolution No positioning errors due to measurement of full distribution Cons High uncertainty in smaller voxels Improves with larger voxels, but volume averaging increases Inconsistencies in preparation Differences in calibration and experimental geometries E. Pappas, I. Seimenis, A. Angelopoulos, et al., Phys. Med. Biol. 46, 783-797 (2001). E. Pappas, L. Petrokokkinos, A. Angelopoulos, et al., Med. Phys. 32, 1513-1520 (2005). E. Pappas, T. G. Maris, A. Papadakis, et al., Med. Phys. 33, 3700-3710 (2006). E. Pappas, T. G. Maris, F. Zacharopoulou, et al., Med. Phys. 35, 4640-4648 (2008). 8

Profile measurements E. Pappas, I. Seimenis, A. Angelopoulos, et al., Phys. Med. Biol. 46, 783-797 (2001). E. Pappas, L. Petrokokkinos, A. Angelopoulos, et al., Med. Phys. 32, 1513-1520 (2005). E. Pappas, T. G. Maris, A. Papadakis, et al., Med. Phys. 33, 3700-3710 (2006). E. Pappas, T. G. Maris, F. Zacharopoulou, et al., Med. Phys. 35, 4640-4648 (2008). 9

Output factor measurements E. Pantelis, C. Antypas, L. Petrokokkinos, et al., Med. Phys. 35, 2312-2320 (2008). E. Pantelis, A. Moutsatsos, K. Zourari, et al., Med. Phys. 37, 2369-2379 (2010). E. Pantelis, A. Moutsatsos, K. Zourari, et al., Med. Phys. 39, 4875-4885 (2012). 10

Film stack Previous investigations of radiochromic film stack [1,2] Considered several characteristics: Water equivalence Energy dependence [3] Orientation dependence [4] Measurement uncertainty 1. S. Chiu-Tsao, T. L. Duckworth, N. S. Patel, et al., Med. Phys. 31, 201-207 (2004). 2. S. Chiu-Tsao and M. F. Chan, Med. Phys. 36, 2074-2083 (2009). 3. J. G. H. Sutherland and D. W. O. Rogers, Med. Phys. 37, 1110-1116 (2010). 4. N. Suchowerska, P. Hoban, M. Butson, et al., Phys. Med. Biol. 46, 1391-1397 (2001). 11

Phantom development TLD phantom Film stack dosimeter phantom Film and ionization chamber phantom Cylindrical phantom housing 12

Film stack dosimeter Circular films with semicircular tabs on the outer diameter Tabs fix azimuthal orientation of films Films were laser cut [1] with a tolerance of 0.08 mm Positioning uncertainty within phantom of 0.19 mm 1 mm-thick Virtual Water [2] spacers interleaved between films Reduces air gap created by film burr Film stack dosimeter specifications: 3.8 cm diameter 2.7 cm height 22 films and 21 spacers 0.02 mm air gaps 1. Laserage Technology Corporation, Waukegan, IL 2. Med-Cal, Inc., Verona, WI 13

FSD characterization: Simulations MCNP simulations used 6 MV point source Spectrum from BEAMnrc model of UWMRRC linac Orientation dependence Simulated dose to cylindrical volume at center of film stack Rotated source about longitudinal axis of tally volume Investigated the impact of air gap size Water equivalence Simulated PDD in a cylindrical water phantom for comparison with film stack dosimeter measurements 14

FSD characterization: Simulations (2) Energy dependence EBT2 absorbed-dose energy dependence exceeds 10% [1] Incident spectrum varies with field size Simulated and compared photon energy spectrum in calibration and film stack geometries 1. J. G. H. Sutherland and D. W. O. Rogers, Med. Phys. 37, 1110-1116 (2010). 15

FSD characterization: Measurements PDD profile measurements Phantoms positioned in cylindrical phantom housing for reproducibility Separate measurements with film stack dosimeter oriented perpendicular and parallel to beam axis Dose at depth measured with Exradin A1SL ionization chamber [1] Slit field dose distribution Measured with film stack dosimeter and TLD microcubes 1. Standard Imaging, Middleton, WI 16

Film Films were read with Epson Expression 10000XL flatbed scanner [1] Immediately before and seven days after exposure Masks center films in scan bed and reduce extra-film scatter Elevated films to eliminate Newton s ring artifacts Monitored scanner stability with neutral-density filters 1. Epson America, Long Beach, CA 17

Results: Orientation dependence Orientation dependence less than 1.5% for smaller air gaps Under-response of 3% at parallel incidence for larger air gaps Statistical uncertainty of 0.5% (k = 1) T. McCaw, J. Micka, and L. DeWerd, Med. Phys. 40, 223 (2013) 18

Results: Water equivalence Simulated PDD profile converted to dose using ion chamber measurement Film stack measurements normalized to max simulated dose Measurements and simulation agree within 2% T. McCaw, J. Micka, and L. DeWerd, Med. Phys. 40, 223 (2013) 19

Results: Energy dependence 3D Visibly different photon energy spectra in calibration and film stack geometries Resulting absorbed-dose energy response less than 0.1% 20

Slit field measurement geometry z y 0 x 21

Results: Slit field profiles x = -0.6 cm x = 0 cm x = 0.6 cm y = -0.9 cm y = 0 cm y = 0.9 cm 22 T. McCaw, J. Micka, and L. DeWerd, Med. Phys. 40, 223 (2013)

Development of IMRT plans Two SBRT lung procedures were prepared using Philips Pinnacle 3[1] Spherical PTV with 2.5 cm diameter Prescription: 50 Gy/5 fractions Energy: 6 MV Step-and-shoot delivery Five-field plan Seven-field plan 1. Philips Healthcare, Andover, MA, USA 23

CT phantom development CT dataset of cylindrical phantom housing was created using MATLAB [1] 2 mm slice thickness 1.35 1.35 mm 2 pixel size ρ CPH = 1.03 g/cm 3 ρ film = 1.00 g/cm 3 1. MathWorks, Natick, MA, USA 24

IMRT DQA measurements Reduced prescribed MU by a factor of 5 for a dose at isocenter of ~2-3 Gy Initial DQA of plans performed with Delta 4 diode array detector [1] 99% passing rate using gamma criteria [2] of 3% and 3 mm Two measurements of each plan were made with the film stack dosimeter Seven-field plan also measured with TLD phantom Compared measured and calculated dose distributions 1 1 1 mm 3 calculated dose grid resolution 1. ScandiDos, Uppsala, Sweden 2. D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, Med. Phys. 25, 656-661 (1998) 25

Seven-field results Sagittal plane Transverse plane Coronal plane Exposure 1 Pinnacle T. McCaw, J. Micka, and L. DeWerd, Med. Phys. Int. 1, 242 (2013) 26

IMRT QA analysis Gamma analysis of film stack measurements using criteria of 3%/3 mm Greater than 97% agreement with calculation Consistent with TLD and Delta 4 measurements Repeatability Five-field plan: 96% of points agree within 5% Seven-field plan: 93% of points agree within 5% Overall film measurement uncertainty is 5.3% (k = 2) T. McCaw, J. Micka, and L. DeWerd, Med. Phys. Int. 1, 242 (2013) 27

Conclusions Polymer gel has strengths and weaknesses for small field Tissue equivalence, good resolution, no fluence perturbation Poor reproducibility, high uncertainty Radiochromic film stack dosimeter provides an alternative 3D dosimeter Maintains strengths of gel dosimeter Improved reproducibility and uncertainty 28

Dr. Larry DeWerd John Micka Acknowledgements Ben Palmer Cliff Hammer Scott Johnson (Med-Cal, Inc.) Dr. Jennifer Smilowitz UWMRRC students and staff UWADCL customers for their continued support of our research program 29