phoenix Upgrade Packages for SLM Model 4800/48000/8000/8100 Spectrofluorometers

Similar documents
Product Specifications

ihr Series horiba.com/osd Research Grade Spectrometers Simply the best imaging spectrometers with no compromise

Introduction to. 3D Scanning Confocal Microscope with Spectrometer

Single Photon Counting System

Standard Operating Procedure for the Horiba FluroMax-4

Prizmatix. Optical Specifications. Mic-LED-635 spectrum. BLCC-02 Benchtop LED Current Controller Specifications

FLUOVIEW FV1000/FV1200

MonoVista CRS+ Raman Microscopes

NDD FLIM Systems for Leica SP2 MP and SP5 MP Multiphoton Microscopes

External Triggering Options

TCSPC on Fluorolog Accessories

Minimizes reflection losses from UV - IR; Optional AR coatings & wedge windows are available.

Optical properties and characterization

SOLAR LIGHTLINE SERIES

Light Sources opmaak.indd :32:50

Raman Sample Holders

DMS 903 FEATURES GONIOMETER SYSTEM FOR COMPLETE DISPLAY CHARACTERIZATION

Imaging Spectrometers

Photo Emission Tech., Inc. 760 Calle Plano, Camarillo, CA USA Tel: (805) Fax: (805)

LASERS FOR ANALYTICAL INSTRUMENTATION

Thermo Scientific GENESYS UV-Vis Spectrophotometer Accessories. Make the most of every sample

Versatile laser Raman Spectrometer. RMP-500 series

The Anfatec Level AFM a short description. Atomic Force Microscopy - approved devices for affordable prices

DataMax version Operation Manual Fax: (33) 1/ U.K.: 020/ i

Spectrograph overview:

Technical Specifications for High speed PIV and High speed PIV-PLIF system

Chapter 3. Experimental Procedure

User Operation Manual

Certus Optic. NanoScanTechnology. Basic Datasheet. reasoned innovations. Integrated Optical and Scanning Probe Microscope

LASERS FOR ANALYTICAL INSTRUMENTATION

UV / VIS SPECTROPHOTOMETER

On-Line Instrument Systems, Inc. 130 Conway Drive, Suites A & B, Bogart, GA (800) (706)

UV-VIS Spectrophotometer

Time-Resolved measurements by FEL spontaneous emission: A proposal for sub-picosecond pumps & probe structural and spectrometric investigations

Series Spectrometers PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

TABLE OF CONTENTS PRODUCT DESCRIPTION CINCAM CCD TECHNICAL DATA SENSOR RESPONSE DIMENSIONS CINCAM CCD LARGE FORMAT TECHNICAL DATA SENSOR RESPONSE

Non-Descanned FLIM Systems for Olympus FV-1000 and FV-300 Multiphoton Microscopes

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Luminex Prima

Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

LIGHT SOURCE Quartz-iodine lamp 12V-20W.

Standard: 2 x 500 ml and 2 x 250 ml (safety) bottles with shut-off valve and 2 µm in-line filter. Built-in 4 channel He degasser.

Cary Fiber Optic Probes

Blade & Vibration Monitor Model Hood Technology Corporation 30 August 2009 Blade & Vibration Monitor Model Overview

SCALA. Scanning Laser Analyzer

TRiCAM APPLICATIONS KEY FEATURES. Time Resolved intensified CAMera. TRiCAM 13001A01 31/10/2013

PyLoN: Applications: Astronomy, Chemiluminescence, Bioluminescence, Phosphor Imaging, Ultra-low light Imaging and Spectroscopy.

Certus Light. NanoScanTechnology. Basic Datasheet. reasoned innovations. Entry Level Scanning Probe Microscope. Scanning Probe Microscope

Certus Standard. NanoScanTechnology. Basic Datasheet. reasoned innovations. Basic Configuration of Scanning Probe Microscope

Model FP-6500 Spectrofluorometer Instruction Manual. FP-6500 for Windows

PHYTO-PAM-II Multiple Excitation Wavelength Phytoplankton & Photosynthesis Analyzer. Differential Analysis of Mixed Algae Samples

DC - Devices and Controller

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Affordable Lab Technology

Cecil Dissolution 4/9/06 4:51 pm Page 1 DISSOLUTION SYSTEMS

DMS 201 FEATURES LOW-COST MANUAL GONIOMETER SYSTEM

OPTICAL BLOCKS OPTO MECHANICS. Optical Components for Optical Measurement OVERVIEW FEATURES USING EXAMPLE

ksa ICE - Integrated Control for Epitaxy

High-Accuracy LIBS with Nanosecond and Picosecond Time Resolution Enabled by Ultrasensitive emiccd Technology

Monochromator & Imaging Spectrograph

PIXIS: 512 IMAGING GROUP

15 Discovery Way, Acton, MA Phone: (978) , Fax: (978) Web Site: Acton SpectraHub TM

Lightsheet Z.1. Light Sheet Fluorescence Microscopy by Carl Zeiss. Fabrice Schmitt, Sales Manager Carl ZEISS France

Leica TCS SPE. Spectacular Imaging! Technical Documentation

SPECTRUM. The world s first fully automated Raman AFM. AFM - confocal Raman - SNOM - TERS AFM KPFM. Raman. AFM-Raman characterization of PS-PVAC

PI-MAX 4: 1024 x 256

Nonlinear optics and two photon microscopy. Table of contents. Sam Whiteley and Seth Parker PHYS 173/BGGN 266 July 13, 2014

THE LOGICAL INTERFACE

CHAPTER 2: THREE DIMENSIONAL TOPOGRAPHICAL MAPPING SYSTEM. Target Object

Pressure Sensitive Paint (PSP)/ Temperature Sensitive Paint (TSP) Part 2

Two slit interference - Prelab questions

Extended Spectroscopic Systems

S800 Spectrawave Visible Diode Array Spectrophotometer

LASERS FOR ANALYTICAL INSTRUMENTATION

Cell-based FLIM Energy-Transfer Measurements Using Alba

User Manual SX20 Stopped Flow Spectrometer

Raman Lab - Laser 1 operation

Familiar, and yet very surprising

LIFA KEY FEATURES APPLICATIONS. Fluorescence Lifetime Attachment LIFA 15001A02 16/03/2015

APPLICATIONS KEY FEATURES. High-speed intensified Camera Attachment

pco.1600 cooled digital 14 bit CCD camera system

2011 Optical Science & Engineering PhD Qualifying Examination Optical Sciences Track: Advanced Optics Time allowed: 90 minutes

PI-MAX 4: 1024 x 256 SPECTROSCOPY GROUP

SPECTROMETERS USER MANUAL. Ver. 1.2_09/16. Making spectroscopy brighter

Spraybase Technical Specifications Sheet

IMAGING GROUP. 512 x 512 imaging array; 24 mm x 24 mm pixels Scientific grade CCD All-metal, hermetic vacuum seals; Lifetime vacuum guarantee

TRIAX Series Spectrometers

Development of automated ultraviolet laser beam profiling system using fluorometric technique

The Autopol VI Automatic Polarimeter

ecovis Krypton Light Source Installation and Operation Manual Document Number

PI-MAX 4: 1024 EMB. Applications:

Edif Instruments Srl - ECHO CONSUMABLES CATALOGUE rel.1.2. EE0201B Standard host cable (ECHO XPC Windows)

HCImage. Image Acquisition and Analysis Software. Light... Camera... Acquisition...

SYNCERITY TM 1024 x 256

Sepacore X10 / X50 system Technical data sheet

Fluorescence Microscope with Spinning Disk Confocal and Total Internal Reflection Fluorescence Modules

Thermo Scientific Spectronic 200 Visible Spectrophotometer. The perfect tool. for routine measurements

Fluorimeter User s Booklet

DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A...

Engineered Diffusers Intensity vs Irradiance

POWERSIGHT LASER DOPPLER AND PHASE DOPPLER MEASUREMENT SYSTEMS

Transcription:

Upgrade Packages for SLM Model 4800/48000/8000/8100 Spectrofluorometers

Phoenix: The Upgrade Packages for SLM Model 4800/48000/8000/8100 Spectrofluorometers The Phoenix Upgrade Packages are designed to modernize the instruments manufactured by SLM Instruments, using the state of the art ISS hardware and software for instrument control, data acquisition and data analysis. Two types of upgrades are available: A: Upgrade to a steady-state instrument. The upgraded instrument will be capable of acquiring excitation and emission spectra, synchronous spectra, polarization (anisotropy) measurements, measurements of intensity at single points and measurements of kinetics using the Vinci Multidimensional Fluorescence Spectroscopy Analysis software for WindowsME/XP acquiring data in photon counting mode on two or three independent channels. B: Upgrade to time-resolved fluorescence instrument. The upgraded instrument will be capable of multifrequency operations using the ISS proprietary Fast-Fourier-transform frequency-domain data acquisition technology. The instrument will be capable of multiple decay times resolution, the measurement of rotational correlation times and the determination of time-resolved spectra with picosecond resolution. A variety of options are available for the SLM spectrofluorometer. For example, a computer-controlled sample compartment and a computercontrolled shutter can automate the data acquisition; additionally, a third photomultiplier tube can be added for simultaneous data acquisition on two emission channels. Finally, the SLM spectrofluorometer can utilize a variety of fluorescence accessories designed by ISS for the most unique fluorescence applications. PAGE 1

Upgrade to Steady-State Fluorescence Operations When this upgrade package is implemented, the SLM data acquisition unit and the monochromator s controller are replaced by ISS electronics and the circuitry of each PMT housing is replaced by a modern-design voltage divider. The resulting instrument features 100 MHz pre-amplifier discriminators giving the instrument a high dynamic range in photon counting acquisition mode. FIGURE 1 SLM spectrofluorometer equipped with ISS data acquisition and processing electronics, as well as ISS xenon arc lamp and power supply. Data acquisition is performed with the Vinci Multidimensional Fluorescence Spectroscopy software and the PCMC data acquisition card using a personal computer. The table on the following page lists the components included in the Steady-State Upgrade Package. Also listed are some of the optional components that can be added to the SLM spectrofluorometer. PAGE 2

Required Components Optional Components PX01 HB-16 PCMC Data Acquisition Card (version 2) PMT Housings Computer UNIT The Vinci Multidimensional Fluorescence Spectroscopy Analysis software for WindowsME/XP Replacement of xenon arc lamp and lamp power supply two-cuvette sample compartment three-cuvette sample compartment Accessories for Fluorescence applications DESCRIPTION The signals from the photomultipliers are diverted into this unit, which includes the preamplifier discriminators. The unit outputs both a TTL signal which is directed into the PCMC card, and an analog signal which is directed to the A2D analog card. The HB-16 is a stepper motor controller. It controls the movements of the SLM monochromators, polarizers, shutters and sample compartment. The card is for data acquisition in photon counting mode of up to three (3) independent channels. Some of the card s features are: five 16-bit counters, one A/D converter, and I/O ports for automatic control of the instrument. The PCMC card allows the user to acquire fast kinetics in photon counting mode (in conjunction with a stopped-flow device). The SLM housings are replaced with the ISS housings for PMTs that feature a voltage divider with a higher dynamic range. A Pentium-2 GHz Personal Computer, with 128 MB RAM, 20.0 GB EIDE hard drive, one 1.44 MB 3.5 floppy drive, one CD-ROM drive, and a high-resolution color VGA monitor. Vinci controls the instrument s automation and its interface to computer-controlled external devices such as a titrator, a temperature bath, or a pressure pump. Vinci includes routines for the automatic acquisition of unidimensional data files (excitation and emission spectra; polarization and anisotropy spectra; synchronous luminescence spectra; slow and fast kinetics studies) and multidimensional data files (intensity and polarization versus excitation and emission wavelengths, time, temperature, lifetime). Raw data is stored in ASCII format along with the experimental parameters. The analysis portion of the software includes data manipulation (operations between spectra, smoothing, correction, derivative and integration). The graphical display allows for 2D and 3D plots as well color display of user defined functions with zooming and rotation capabilities, statistical operators, and plot export to popular formats (metafile, bitmap). The lamp and the power supply are replaced with ISS components. The accessories list includes: the High Pressure cell; the TIRF cell; vacuum chamber, Dewar. TABLE I: Components of the Steady-State Upgrade Package. PAGE 3

Upgrade to Time-Resolved Fluorescence Operations This Phoenix upgrade package includes the units required for the steady state portion and the units specific to the lifetime mode of operation. The SLM spectrofluorometer becomes a Multifrequency Phase and Modulation fluorometer equipped with Fast-Fourier-transform data acquisition, which enhances the instrument s sensitivity. Table II below lists the components included in the time-resolved upgrade package. The optional components that can be integrated into the SLM are also listed. Required Components Optional Components UNIT DCA2D200K Data Aquisition Card Vinci and Global Analysis Software Replacement of frequency synthesizers Replacement of RF amplifiers two-cuvette sample compartment three-cuvette sample compartment DESCRIPTION The ISS-DCA2D200K acquisition card for Fast-Fourier-Transform acquisition of frequency domain data operating with computer selectable cross-correlation frequency up to 15 KHz and variable-bandwidth digital filter. It features two acquisition channels, with 16-bit A/D converters and on-board DSP. The package includes the electronics and acquisition software. The complete software package includes routines for the acquisition and determination of multiple fluorescence decay times; the acquisition and determination of rotational correlation times in isotropic, anisotropic and hindered rotators; the measurement of time resolved spectra with picosecond resolution. The standard ISS frequency synthesizers, working in the range 9 KHz up to 1.2 GHz, replace the signal generators supplied with the instrument. ISS RF amplifiers for the Pockels cell and the PMT replace the original RF amplifiers. TABLE II: Components of the Time-Resolved Upgrade Package. FIGURE 2 ISS Monochromators controller and data processing unit for the SLM spectrofluorometer. The unit provides both a digital output (photon counting) and an analog output (fast kinetics and lifetime determinations). PAGE 4

Optional Upgrades and Fluorescence Accessories for SLM Spectrofluorometers The Optional Upgrades available for the SLM spectrofluorometers are user friendly and designed to boost the instrument s performance and sensitivity. The compact ISS xenon arc lamp increases the sensitivity of the instrument as it delivers a higher intensity than the original 450 W SLM lamp. Moreover, the linear power supply allows the user full control of the light intensity irradiating the sample. The instrument can be automated for the acquisition of lifetime measurements with the addition of a computer-controlled sample compartment and shutter. The standard ISS modulation electronics widen the frequency response of the instrument that can be equipped with mode-locked lasers. FIGURE 3 The ISS lamp and power supply replace the original components. The collimated beam of the ISS xenon arc lamp increases the sensitivity of the instrument. FIGURE 4 The ISS three-cuvette sample compartment. The sample compartment can be utilized for any lifetime or steady-state measurement. The primary use for the three-position sample compartment is to perform an automated blank subtraction routine during lifetime measurements. PAGE 5

copyright 2003 iss, inc. all rights reserved. ISS provides a variety of accessories for fluorescence applications that are readily integrated in any SLM spectrofluorometer. A list of the accessories includes special sample holders, PMT housings, polarizers and fiber optics. Sample Compartments and Sample Holders One-cuvette, Peltier-controlled, sample compartment. Two-cuvette, computer-controlled sample compartment with flow through system for temperature control. Three-cuvette, computer-controlled sample compartment with flow through system for temperature control. Four-cuvette, Peltier-controlled, sample compartment. Dewar flask for liquid nitrogen temperatures. Vacuum chamber. High pressure cell. Total Internal Reflection Fluorescence (TIRF) Flow Cell. Variable-angle, front surface sample holder for solid and high-turbidity samples. Variable-angle coverslip holder for the study of cells that adhere to the glass surface of a coverslip. PMT Housings Housing for PMT, for steady-state, high-sensitivity photon counting detection and for frequency domain fluorometry applications. The housing includes the high voltage power supply with manual/automatic voltage control. Cooled housing for side-on PMT. Includes power supply, thermo-electric cooling unit with related electronics, circuit for external liquid circulation (requires a bath circulator). Polarizers UV Glan-Thompson prism polarizers, 10x10 mm aperture. UV Glan-Taylor prism polarizers, 14x14 mm aperture. Titrator and Stopped-Flow Apparatus Computer controlled titrator. Stopped flow package for SLM spectrofluorometer (working with stopped-flow devices by Applied Photophysics, Hi-Tech, Molecular Kinetics and OLIS). Fiber Optics Bifurcated fiber optic bundle, in quartz, 1.5 m long, with adapter for SLM, for in-situ fluorescence measurements. Chemically activated fiber tip and fiber optics, complete with XY control and dichroic mirror. Specifications are subject to change without prior notice. October 2003 ISS, Inc. 1602 Newton Drive Champaign, Illinois 61822 USA 217 359 8681 PHONE 217 359 7879 FAX www.iss.com WEB