Installation & User Manual

Similar documents
Installation & User Manual V2.08

Contents Installation Instructions 3 Installation Diagrams System Overview Wiring Diagrams Network Diagrams

Installation & User Manual V1.0

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro 1500 Single Door IP Controller

Access control panel U-Prox IC E (Elevator control)

Access Control Technology Ltd. reserve the right to change the contents of this manual and the system it applies to without prior notice.

BioPointe Reader Installation Guide

pro ACTpro IOM INPUT/OUTPUT MODULE Installation and Configuration Instructions for the ACTpro IOM Input/Output Module ACT Product Code: ACTPRO IOM

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

Access control software SENATORFX. Quick start guide

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

GENERAL QUICK START GUIDE

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16

A-1300 Biometric Access Control System USER'S MANUAL

WiFi to RS-232 adapter user manual

180 Series Keypad. Handbook. Revision 2.1

IPassan Installation guide

Industrial Serial Device Server

T- P1000 HandSwipe guide. Table of Contents. Initial setting 3. Programming the HandSwipe 4. Service Menu (1) 5. Setup Menu (2) 6

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description


Docking Station DS-U4WEB with web server version 1 Instruction Manual

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

NETAFIM WILL NOT ACCEPT RESPONSIBILITY FOR DAMAGE RESULTING FROM THE USE OF NETAFIM'S PRODUCTS OR THE USE OF THIS MANUAL.

icam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box

ACCESS CONTROL SYSTEM

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Documentation on all Paxton products can be found on our web site -

UC-2000 Installation Manual Unicorn Computers Technology Limited

ievo ULTIMATE INSTALLATION GUIDE

Akcess BioMetrics Corporation. Bio2Touch. Access Control Fingerprint Reader. User's Manual. Akcess BioMetrics Corporation

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

User Manual. PCKeypad Wireless Keypad

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

ACTPRO ACCESS CONTROL. Specification Guide

H2i. s u p p o r f i n g e r t e c. c o m. H2i. Simple Fingerprint Door Access & Time Attendance System. User Guide

User Manual. cmt-svr Startup Guide

ACTsmart2 Product Range Operating and Installation Instructions

Digital Keypad Introduction

User Manual. cmt-svr Startup Guide

Installation Instructions (KF-2000)

GV-Card Reader. User s Manual

User s Guide. Ethernet Module for Barcode Printer

Simple Card Reader for Door Access & Time Attendance System. User Guide

Technical documentation

Quick Start Guide V5.0

GV-AS Controller. Installation Guide

SNAP, CLICK, DONE. Getting Started Guide

Quick Start Installation Guide

MorphoManager User Manual. Table of Contents

Entryphone. PinNet 4. Product manual. October 2010 R Granville Road, London SW18 5SD

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

CA111x-series Arming Station

MinitMan-FP Handbook (Installation for TimeMaster & MP-Lite) Revision 3.0

Startup Guide. NetAXS-123. Version 5.2

AIM- DAC System. DAC844 User Manual. Anviz Global Inc

REX F-0-9 Standalone or Access Controller

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Installation Instructions

Operation manual For NG BIOSINGLE Version 1.1

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01

CR3000 Copy Reader. Installation Guide

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

ELITE Test Systems. /Quick Start Wiring. Botron Company Inc.

Synergis Master Controller 2.2 Integration Guide for Mercury Interface Modules

Hardware. - (0191)

SNMP Web Management. User s Manual

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

Strike View 7.0 SERVER CLIENT SIMULATOR USER S GUIDE

Suprex RS-485 SPX-7500 Wired Reader-Extender

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Cardax FT Controller 3000

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

GV-AS200 Controller. Hardware Installation Guide

D/E Remote Relay Panel User Guide

Wireless Key fob, Key pad & Receiver Range

PCR43304R, PCR43304RE 4-Channel, 433MHz Penta Receiver with Frequency Hopping

AX3000 Platine Terminal Ethernet TCP/IP

ETH044-4 SSR (230VAC) and 4 Digital IO

Fingerprint Access Control F1. User Manual

PRO3200 Professional Modular Access Control Hardware

Installation and User Manual

VIS-3200 / VIS-3201 User Manual

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

Canlan INSTALLATION MANUAL

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Click Save to return to the main Setup screen.

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Serial Interface Module

Transcription:

Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com Installation & User Manual

2 Technical Specification Technical Specs - Wi-Enterprise Controller Power Supply 230 VAC Current consumption 30mA Fuse Rating 230VAC 315mA T Moisture Resistance Indoor Use Only Dimensions W. 260mm D. 262mm H. 55mm Technical Specs - Wi-Enterprise s Power Supply 12 DC Current consumption 110mA Current consumption with load (max) 145mA Relay Contact Rating 5 Amps /230V ac Operating Temperature - 20 C to +60 C Moisture Resistance IP 67 ( IP65 on Wi-Bio ) Dimensions - Flush Mount W. 87mm D. 21mm H. 119mm - Surface Mount W. 87mm D. 35mm H. 119mm Features Doors controlled Users User Groups Time Zones Door Groups Reporting Facility Challenge Facility Logging Input/Output Mapping Supports Wireless & RS485 Networks Automatic Backup Facility Database Encryption 20 20000 128 128 128 Yes Yes Unlimited CCTV & Lift control Yes Yes Yes Installation Records Ctrl Door No. Door Type Door Location Name Walk Test 2 3 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 27

26 Installation Record Ctrl Door No. Door Type Door Location Name Walk Test 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 2 1 2 3 4 5 6 7 8 9 10 Installation Steps Installation Steps Page 1 Install the Controller using the Installation Diagrams 4-5 2 Wire the Controller using the Wiring Diagrams 8 3 Install and wire each. Refer to the Manual for instructions. 4 Connect the Controller to the PC using Network Diagrams 9-11 5 Restoring Factory Defaults 11 6 Setting up TCP-IP 12 7 Phase 1- Setting up the Controller via the PC application 14 8 Phase 2 - Configuring the Controller via the PC application 15 9 Phase 3 - Defaulting s 16 10 Phase 4 - Enrolling s 16-18 11 Phase 5 - Configuring Users 19 12 Phase 6 - Configuring Access Levels 20 13 Phase 7 - Downloading Configuration 20 14 Enrolling User Fingerprints 21 15 Correct Finger Placement techniques 22-25 3

4 Installation Diagrams Finger Placement Wi-BIO 25 Control Panel opening Incorrect Finger Placement remove screw cap remove retaining screw to remove cover pull forward on right and slide left

24 Finger Placement Wi-BIO Installation Diagrams 5 Correct Finger Placement Control Panel features mount hole access to rear void for wiring cable entry mount with 4 x 1.5 inch No. 8 Security Type screws spirit level mains pcb cable entry cable entry spare cap rear tamper switch mount hole mount hole cable entry

6 System Overview Finger Placement Wi-BIO 23 RS485 Connection to s Incorrect Finger Placement Note: If using a single Controller, an RS232 cable may be used. Max cable length 10 meters TCP-IP connection to Controllers or RS485 Network to Controllers Max number of Controllers 3 Max Cable Length 1.4 km Controller #2-3 Place a 120ohm Termination Resistor across A & B on the Controller Controller #1 Note: Incorrect placement : finger does not fully cover the sensor window. RS485 Network to s Max Cable Length 1.4 km. Daisy Chain Configuration Only. Note: Poor Quality image, No Fingerprint core on sensor window. Poor Quality Image Place a 120ohm Termination Resistor across A & B on the last in the chain. This can result in poor template quality that can lead to false rejection issues later when the user is trying to gain access. #1 #2 #3 #4-20

22 Finger Placement Wi-BIO Correct Finger Placement Wireless Connection to s System Overview 7 Note: If using a single Controller, an RS232 cable may be used. Max cable length 10 meters TCP-IP connection to Controllers or RS485 Network to Controllers Max number of Controllers 3 Max Cable Length 1.4 km Controller #2-3 Good Quality Image Controller #1 Note: Ensure that the core of finger is centered on the sensor window during the enrollment process. This will increase the quality of the fingerprint template. Ensure a value of at least 90% is achieved. #1 #3 #4 Note: Good Quality image, Fingerprint core is center of sensor window Note: The System does not store the finger print. It uses an algorithm to generate a binary representation using sample points from the fingerprint. It uses this information to then validate each users fingerprint. #2 Note: s can be installed within 30 meters of the Controller or within 30 meters of any other as each will function as a repeater. Each transmits data to/from the Controller. These distances are a guideline. The actual communication range depends on building shape and construction methods used. #5-20

8 Wiring Diagrams Wiring Diagrams Warning : Installation should only be carried out by a suitably qualified person only. Operation Instructions Enrolling User FingerPrints Note: Make sure the USB Fingerprint reader is attached to the PC 21 Cable Tie retaining clips Cable Tie Neutral Earth Live 1. On the Users Tab, Select a User for fingerprint enrolment 2. Click on the Fingerprints button. Note : Used LY for Wired 485 Network Connections. Door Network PC Network Connections can be used for multiple controllers See page 10 for wiring PC Direct Fuse Rating : 230VAC 315mA PC Network 3. Click on + button to begin and place finger on the enrolment reader. An image of the fingerprint will appear on the screen. Ensure that the image quality is good and a value of at least 90% is achieved. Refer to section Finger Placement for correct finger placement and example of good quality image. Repeat this process if this is not achieved on first attempt. Two fingerprint templates can be saved for each user. Main Input Cable 230VAC Remove Battery Tab Inputs/outputs IP1 IP2 0V IP3 IP4 12V OP1 OP2 A B COM A B COM TX RX Pull 4. Click Save using a good quality template only. Poor Quality templates can lead to false rejections later when trying to gain access Inputs/outputs OP3 OP4 0V VOUT DAT CLK SEN 3V Lithium TCP_IP

20 Operation Instructions Phase 6 - Configuring Access Levels Network Diagrams for Single Controller Network Diagrams 9 Access Levels are controlled by creating UserGroups and assigning the UserGroup to a User as described in section Configuring Users. 1. UserGroups are created by combining pairs of DoorGroups with Timezones. Each UserGroup can have up to 6 pairs of DoorGroups and Timezones. Select DoorGroups and Timezones from the drop-down menus to add to the current UserGroup. 2. Timezones are the periods of time for each day of the week that access will be granted. Select times and tick the days of the week this time is valid. 4 time periods can be created for each timezone. Select Holiday Access to grant access for holiday periods. Double click on the Holiday Access to add days to the holiday periods. Use the calendar to select these days. 3. DoorGroups are created by grouping doors together. e.g. all the entry and exit doors could be grouped together as Peremiter Doors. Select a Door from the All Available Doors window and drag it to the Doors in Current Group to add it to the Door Group. Repeat for adding doors as desired. Connect DB9 cable to serial port on PC Maximum cable length 10 meters PC Direct Connection can be used, when using LY one GSD Controller. Set the Direct address to ALL dip switches (see below ) DB9 Female Serial Cable 6 7 8 9 1 2 3 4 5 PC Network PC Direct Door Network A B 0V TX RX A B 0V Phase 7 - Downloading Configuration After all users, access levels and door control settings have been finalised, a full download to the controller should be carried out. 1. Go to the Settings tab and click on Download Configuration. A pop-up window will appear, tracking the status of the download. All settings will be downloaded to the Controller and s. Direct Connect - All Dip Switches See page 11 on Configuring Controller Communication to setup the application for serial communications

10 Network Diagrams Network Diagrams for Multiple Controllers Phase 5 - Configuring Users Operation Instructions 19 1. Enable a User by ticking the Enabled box for each User RS485 Converter 12V Controller 1 2. Assign a Name to the User Connect using RS232-RS485 cable to serial port on PC PC Network Connections, when using more than one GSD Controller. 19200 9600 Set Baud Rate to 19200 12V - 1 0V - 2 B - 3 A - 4 Daisy Chain each controller 0V B A PC Network PC Direct A B 0V TX RX 3. Assign a UserGroup from the drop-down menu. The UserGroup will determine the access levels for this User. Refer to section on page 20 Configuring Access Levels for information on User Groups. 4. Assign a Card, PIN number and enroll FingerPrints for the User. Refer to section FingerPrint Enrolment on page 21 Click save to transmit these changes to the Controller. Daisy chain the PC network A, B, 0V to each controller. Set an individual address for each controller between 1 & 3 using the dip switches (see below ) Controller 2 Controller 1 Controller 2 PC Network PC Direct A B 0V TX RX Controller 3 Address 1 - Set SW1 Address 2 - Set SW2 Address 3 - Set SW3

18 Operation Instructions Phase 4 - Enrolling s 4. Once all s are enrolled onto the network go back to the PC application and click Secure Network button. this safeguards the systems and secures the network. 4. Select each Door on the application and configure individual settings such as Door Name, Timed Actions, Relay Times, Ajar Times, Door Option and Alarm Options etc. Configuring Controller Communications 1. On the Controller Tab, set the Connection - Type to Serial 2. On the Settings tab in the communications section, Select the Serial Port number from the drop-down list connected to the Controller. Setting the Controller address Network Diagrams The Controller Address is set by configuring the Dip switches as shown below. 11 Timed Actions: IMPORTANT: A timezone must be selected in Timed Actions for one of the options: Card and PIN, Any Card, Card or PIN, or PIN only. If all of these are set to inactive then access will be denied for all cards and PINs on that. Example: To Enable PIN codes only on a Wi-PIN&Prox: Set the Timed Action Card or PIN to Inactive and set the Timed Action PIN Only to All day,every Day. This will grant access for PIN codes and deny access for cards and fobs. Direct Connect - All Address 1 - Set SW1 Address 2 - Set SW2 Note: Address 3 - Set SW3 only Restoring Factory Settings To restore the factory default setting, Set ALL Dip Switches 1,2,3 & 4 to the position and then power-up the Controller. Example: All Dip Switches are set to the position. Note: Factory Default settings will be restored after powering up the controller with All dip-switches. The dip-switches s should then be set to the controller address as shown above in section Setting the controller address

12 Operation Instructions Operation Instructions 17 Setting up TCP-IP - DHCP 1. Default the Controller. See Restore Factory settings on page 11. The default TCP/IP mode will then be set to DHCP. 2. Set the Controller address to address 1. See page 11 for details. Connecting the Controller to your DHCP LAN. 1. Connect the Controller to your LAN using an ethernet cable. The Controller will be assigned an IP address automatically by your DHCP server. 2. Open the GSDWin application. On the Controller tab, Select TCP/IP with the DHCP option and enter the MAC address of the Controller and click Apply. The MAC address of the controller can be found on the box or printed on the Controller PCB. The Controller icon will turn blue when it comes online. Phase 4 - Enrolling s 2. The controller is now ready to allow s to enroll onto the Network Go to the Controllers tab and Click on Wireless Network and then click Allow Doors to Join. This opens the network and starts the controller scanning for any new doors that do not already have an address only s without an address can be enrolled. Note: For Wired 485 s, right click on the Controller on the right hand side of the application and select Manually Assign Address from the drop down menu. Once all new s are found by the Controller they will all beep with the number of the next available address/door position on the Controller. e.g. if door 2 is the next available address then all s will beep at the same time with 2 beeps. This is basically saying that any door can be assigned to this address it s up to the installer to decide which one. Also you will notice that the Key back light of the keypad s will be illuminated with the next available address as well. i.e. Key 2 will be illuminated for this example. 3. Go to the Door control that you want to make door 2 on the network system (it should be beeping 2 times). Press any key on this keypad and the system will automatically assign this door control to door 2 address on the system. Present a card if the is Prox Only. Note: All other s will now start beeping with the next available address i.e. 3 beeps (address 3) in this instance and so on every time you enroll a new. The key back light will also correspond to each address as the system fills up. E.g. The 3 key will light up to indicate address 3.

16 Operation Instructions Operation Instructions 13 Phase 3 - Defaulting s All s should be installed at this point and powered up. 1. All s must be defaulted before joining a network. Note: s will be shipped with their factory default settings. Enter Engineer mode on each Keypad in the following way A. Press X followed by 6666 B. Enter 55 to default C. Press the tick to confirm the keypad will now go through the process of defaulting itself. D. The process could take 20-30 seconds. The LED will flash once every second when it is complete E. Repeat the process for all keypad s Enter Engineer mode on each Wi-Bio in the following way A. Enter 6666 B. Enter 55 to default C. Scan Finger to confirm the will now go through the process of defaulting itself. D. The process could take 20-30 seconds. The LED will flash once every second when it is complete. E. Repeat the process for all Wi-Bio s Enter Engineer mode on each Prox Only in the following way A. Add a programming card to the by presenting a card twice on power-up. The security wing must be removed first! B. Present this new programming card to enter Engineer mode. C. Present the programming card again to select Default mode. D. Present any other card once to default the. E. The process could take 20-30 seconds. The LED will flash once every second when it is complete Setting up TCP-IP - Static IP 1. Default the Controller. See Restore Factory settings on page 11. The Controllers default IP address is 169.254.1.1. 2. Set the Controller address to address 1. See page 11 for details. 3. Connect the Controller directly to a PC to using an ethernet cable. Connecting the Controller directly to a PC using default IP address.. 4. Connect an Ethernet cable between the Controller and the PC. (The default IP address of the Controller is 169.254.1.1) 5. Set the IP address on the PC to a similar IP address e.g. 169.254.1.2 Note: If there is no LED activity on your PC s ethernet interface then the PC requires a cross-over cable between the PC and the Controller. 6. Open the GSDWin application. On the Controller tab, Select TCP/IP with Static option and enter the default Controller IP address of 169.254.1.1 and click apply. The Controller icon will turn blue when it comes online. A new IP address can then be sent to the Controller using the Controller TCP/IP Configuration button. Sending a new IP address to the Controller e.g. 192.168.1.26. 7. Make sure the controller is online and click on the Controller TCP/IP Configuration button. 8. Choose Static IP mode and enter the IP address, Netmask and Default Gateway assigned by your network administrator. Click Send new settings to Controller. The Controller will now go offline as the new IP Address settings are applied. 9. Connect the PC and Controller to your LAN and enter the new IP address to allow the application to communicate with the Controller. Note: Reset the IP address on your PC to its original setting for your LAN.

14 Operation Instructions Phase 1 - Setting up the GSD Controller Phase 2 - Configuring the GSD Controller Operation Instructions 15 1. Install the main TS SMART Controller and power up 2. Begin by Defaulting/Restore Factory Settings on the controller via the dip switch settings (see instructions on page 11) 3. Important! Once powered up and the controller has completed the default the process reset the dip switches to the correct address positions. (see instructions on page 11) 4. Follow instructions on the CD provided to install the GSD PC application. To download the latest drivers, enter the following link in your web browser. http://www.globalsecurity.ie/userfiles/files/gsdwin Access en-us.zip Note: Make sure the USB enrollment reader is not connected to the PC before the GSD application is installed. 5. Launch the application: A. Launch the application by clicking the GSDWin icon on the desktop. The Site Database Management will appear. B. Click on Create New Site, then click Create New Wi-Enterprise Site and save the name of the new installation site. The application will then launch. C. Log in to the application as the Engineer (not the administrator) with the password 6666. D. Connect to the Controller. Refer to page 12 & 13 for setting up DHCP or Static IP addresses E. The Controller icon will change colour from gray (off-line) to green (on-line) to show that the Controller is communicating with the application. F. Go to the 'Current Events' tab to view the current log messages from the Controller 1. Open the Doors tab in the main menu to add the required number of new doors to be part of this network. One door will already be added by default. Click on the + button to add new doors. - to remove doors. 2. Make sure all doors are Enabled and then click Save. 3. Open the Settings Tab and do a Configuration Download to the Controller this gives the Controller a clean set of instructions before beginning to enroll doors onto the network. 4. Create a New Wireless Network. WARNING! A New Network should only be created on first installation. Creating a new network will overwrite any existing network information and any enrolled s will be un-enrolled. All s will have to be defaulted and re-enrolled on the new network that has just been created! A new network is now ready to be created. Go to the Controllers tab and Click on Wireless Network and then click on Create New Network. Click Yes on the pop-up to proceed. Note: It will take about 20-60 seconds to complete. a pop-up will appear when the network has been created.