GV-AS200 Controller. Hardware Installation Guide
|
|
- Theresa Fisher
- 5 years ago
- Views:
Transcription
1 GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use.
2 2008 GeoVision, Inc. All rights reserved. Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of GeoVision. Every effort has been made to ensure that the information in this manual is accurate. GeoVision is not responsible for printing or clerical errors. GeoVision, Inc. 9F, No. 246, Sec. 1, Neihu Rd., Neihu District, Taipei, Taiwan Tel: Fax: Trademarks used in this manual: GeoVision, the GeoVision logo and GV series products are trademarks of GeoVision, Inc. Windows and Windows XP are registered trademarks of Microsoft Corporation. June 2008
3 Contents 1. Introduction Main Features Models AS200 Module Layout AS200 Controller Work Modes Installation and Wiring Connecting AS200 Controller to the PC Connecting Inputs Connecting Outputs Connecting Card Readers Connecting the Power AS200 Controller Operation How to reboot AS200 Controller How to reset AS200 Controller to factory defaults Status LEDs ASKeypad Installation Setting Parameter Displaying System Information AS200E Installing AS200E on a Network Fixed IP Connection DHCP Connection Connection over LAN Connection over Internet System Settings System Setup Updating Firmware Changing Login ID and Password Setting Controller ID and Work Mode Specifications Troubleshooting I
4 II
5 1 Introduction 1. Introduction 1.1 Main Features 2 doors expandable to 4 doors with optional Expansion I/O Module Support 4 Wiegand card readers of 26~40 bits Support up to 8 card readers via RS-485 connection Each door supports door opener, door status sensor, fire detector and tamper detector Each door supports electric lock and alarm relay output Door alarms including tamped alarm and door held open alarm RS-485 connection or optional Ethernet Module for programming Optional hot-swappable LCD keypad for a quick programming 1.2 Models The AS200 Controller has the following models: AS200-2 AS200-4 AS200-2C AS200-2E AS200-4E AS200-2CE - Support 2 doors - Expandable to 4 doors - Support 4 doors - Compact version of 2-door support - Support 2 doors - Expandable to 4 doors - Support TCP/IP communication with Ethernet Module - Support 4 doors - Support TCP/IP communication with Ethernet Module - Compact version of 2-door support - Support TCP/IP communication with Ethernet Module 1
6 1.3 AS200 Module Layout 12V + - GND TEMP2 12V D0 D1 GL RL BZ GND 12V D0 D1 GL RL BZ GND 12V D0 D1 GL RL BZ GND 12V D0 D1 GL RL BZ GND Fire Tamper GND Fire Tamper GND Fuse2 Wiegand D Wiegand C Wiegand B Wiegand A Door B Door A (Special Terminal) Door A Door B Door C Door D Reset Green: ON:Door Open Reset EN Flash:Hold Open Alarm Yellow: ON:Open Door Button Active Red: ON:Fire Alarm Flash:Force Alarm Door(A,B,C,D) Input type ON:NC type ON DIP OFF:NO type Force Fire Button Sensor Sensor Door A Force Fire Button Door C Door D Door B ECE ON Input Contact type.1. ECE 12V Voltage Input.1. ECE Dry Contact Input AS200 Default Door Relay type NC ON Connect to AS-Keypad ON ECE Default EN Ethernet External I/O ECE ECE ECE ECE Fuse1 TEMP1 GND V DC 12V - + Green: ON:Door Open Flash:Hold Open Alarm Yellow: ON:Open Door Button Active Red: ON:Fire Alarm Flash:Force Alarm Button 2 Button 1 Sensor 2 Sensor 1 Input Door - Door + Urgent 2 Urgent 1 DoorB Output Power - Power + Alarm - Alarm + Button 2 Button 1 Sensor 2 Sensor 1 Input Door - Door + Urgent 2 Urgent 1 DoorA Output Power - Power + Alarm - Alarm + ON:NC type OFF:NO type Door(A,B,C,D) Input type ON Tamper Fire Button Sensor DIP Tamper Fire Button Sensor Input Contact type.1. ECE 12V Voltage Input.1. ECE Dry Contact Input Door Relay type NC ON 2
7 2 AS200 Controller Work Modes 2. AS200 Controller Work Modes The AS200 Controller supports the four types of work modes for door-access control: One-way control: A door is equipped with one card reader for entry. For example, a user may swipe a card to open the door of office and push a button to leave from the same door. Two-way control: A door is equipped with two card readers. The outer reader is defined as entry reader and the inner reader is defined as exit reader. For example, a user may swipe a card to gain access to a laboratory, and swipe a card to exit from the same door. Mixed control: A mix of One-Way and Two-Way Control applications. Some doors are equipped with one card reader for entry and some doors are equipped with two card readers for entry and exit. For example, a building includes both office and laboratory applications. One-way traffic: Two doors are applied for entry and exit separately. For example, in a parking lot, a user may swipe a card at the entrance and swipe a card again at the exit. By default the AS200 Controller is set to one-way control. For the applications requiring more than 2 doors, the Expansion I/O Module can be added to expand two additional doors. 3
8 4
9 3 Installation and Wiring 3. Installation and Wiring Please open the AS200 Controller cabinet and wire the necessary connections to the AS200 Controller module. 3.1 Connecting AS200 Controller to the PC OR GND V RS-485 GV-HUB / GV-COM / GV-NET/IO Card V3.1 PC The connected computer is used to program the ASServer. The communication mode can be either RS-485 or Ethernet. The default value is set to RS-485 with 57600bps. For Ethernet mode, an optional Ethernet module is required. For RS-485 connection to the PC, the GV series products for RS-485/RS-232 converter can be applied, such as GV-Hub, GV-COM and GV-NET/IO Card V3. Note: The AS200 Controller is not compatible with GV-NET Card and GV-NET/IO Card of versions earlier than V3. The maximum of 16 AS200 Controllers can connect to the same COM port. 5
10 3.2 Connecting Inputs The AS200 Controller provides four digital inputs: - Button inputs, e.g. door opener - Sensor inputs, e.g. door status sensor - Fire inputs, e.g. fire detector - Tamper inputs, e.g. tamper detection sensor The factory defaults of Button inputs and Sensor inputs are set to wet contact; the defaults of Fire inputs and Tamper inputs are set to dry contact. The inputs are located at the bottom of the AS200 Controller module. Input Contact Switch Input Contact Switch Button 2 Button 1 Sensor 2 Sensor 2 Input The inputs are located at the top right of the AS200 Controller module. Door B Door A (Special Terminal) Button Inputs The Button inputs can connect to a door opener device for entry or exit. By using the Input Contact Switch next to the Button inputs, set your Button device to dry or wet contact. Refer to Input Contact Switches below. Senor Inputs The Sensor inputs can connect to a door s micro switch for door status monitoring. Triggering the Sensor inputs can generate the two alarm states: 6
11 3 Installation and Wiring Tamper alarm- when the door is forcibly opened by unauthorized persons. Door held open alarm- when the door is open for a period exceeding the lock strike programmed open time. By using the Input Contact Switch next to the Sensor inputs, set your Sensor device to dry or wet contact. Refer to Input Contact Switches below. Fire Inputs The Fire inputs can connect to a fire detection device such as smoke detector. The default setting is dry contact. Tamper Inputs The Tamper inputs can connect to a tamper switch to detect unauthorized opening of the door. The default setting is dry contact. Input Contact Switches For Sensor inputs and Button inputs, you can use the Input Contact Switches to change the contact type. 1 ECE 1 ECE 1 Default: Wet Contact (12 Voltage Input) Dry Contact Input NO and NC Switches Using the switches to set the four digital inputs for NO (normally open) or NC (normally closed) mode. ON ECE ECE ON:NC type OFF:NO type Door(A,B,C,D) Input type ON Tamper Fire Button Sensor DIP Tamper Fire Button Sensor 7
12 3.3 Connecting Outputs The AS200 Controller provides three relay outputs: - Door outputs +/-, e.g. electronic lock - Alarm outputs +/-, e.g. siren or bell - Urgent outputs, e.g. emergency door release button Door Relay Switch (2-in-1 set) Power - Power + Alarm - Alarm + Door - Door + Urgent 2 Urgent 1 Output This figure illustrates the wiring configuration for output relays when the door relay is set to be normally closed. Door Relay of Normally Closed FIRE 8
13 3 Installation and Wiring This figure illustrates the wiring configuration for output relays when the door relay is set to be normally open. Door Relay of Normally Open FIRE Door Outputs The Door outputs can operate a door-locking device such as electromechanical strikes and can be configured to operate in NC (normally closed) or NO (normally open) modes. To configure the NO mode, push one set of two Door Replay Switches downward. To configure the NC mode, push the switches upward. NC NO (Default) Alarm Outputs The Alarm outputs can connect to an alarm annunciator such as siren or bell. Urgent Outputs The Urgent outputs can connect to a button or device that forcibly open a door without reading a card. 9
14 Note: 1. If your output devices require more than 12V DC, connect the necessary power directly to the power terminals without using the AS200 Controller power converter. 2. The door-locking and alarm devices must use the same voltage, or device damage may occur. 3. If the door-locking device (Door +/-) is a grounded circuit type (NC), the emergency door release device (Urgent 1/2) must be configured as the same circuit type as well. 4. If the emergency door release device (Urgent 1/2) is not connected and the door relay is normally closed, please close the Urgent circuit. 5. If the door-locking device (Door +/-) and alarm (Alarm +/-) are the relay outputs of dry contact, please: - chain Urgent 1 and Door + together - chain Alarm + and Power + together FIRE 3.4 Connecting Card Readers The AS200 Controller supports two types of card readers: Wiegand and RS-485 interfaces. The two types of card readers can be used together to operate with the AS200 Controller. 10
15 3 Installation and Wiring 12V Wiegand Card Reader Wiegand D0 D1 GL RL Wiegand D BZ AND GND RS V Card Reader - + GND Wiegand Devices The AS200 Controller supports up to 4 Wiegand inputs (Wiegand A, B, C, D) for connection of Wiegand devices ranging from 26 to 40 bits. Please consult your Wiegand device documentation for wiring. The pin assignments for the Wiegand terminals are described as below: Pin 12V D0 D1 GL RL BZ GND Function 12V Power Supply Wiegand Data-0 Wiegand Data-1 Green LED Red LED Beeper GND of the Power Supply The maximum distance the Wiegand signal will travel is 500 feet. RS-485 Devices For long-distance connection and non-weigand card readers, you can use the RS-485 connectors. Via RS-485 connection, up to 8 card readers can be supported. Note: For RS-485 connection, you must set GV-Reader ID to Extended Wiegand by using ASKeypad. See 5.2 Setting Parameter. 11
16 Corresponding Tables between Doors and Card Readers The following tables show how and where each card readers should be placed based on different work modes. Wiegand Card Readers The default 2-door applications: Door A and Door B Work Mode Door A Door B In Out In Out One-way control Wiegand A Button inputs Wiegand B Button inputs Two-way control Wiegand A Wiegand C Wiegand B Wiegand D Mixed control Wiegand A Button inputs Wiegand B Wiegand D One-way traffic Wiegand A Non Non Wiegand B Using an optional Expansion I/O Module to add two additional doors: Door C and Door D: Work Mode Door C Door D In Out In Out One-way control Wiegand C Button inputs Wiegnad D Button inputs Two-way control Non Non Non Non Mixed control Wiegand C Button inputs Non Non One-way traffic Wiegand C Non Non Wiegand D RS-485 Card Readers The default 2-door applications: Door A and Door B Work Mode Door A Door B In Out In Out One-way control RS-485 No. 0 Button inputs RS-485 No. 1 Button inputs Two-way control RS-485 No. 0 RS-485 No. 2 RS-485 No. 1 RS-485 No. 3 Mixed control RS-485 No. 0 Button inputs RS-485 No. 1 RS-485 No. 3 One-way traffic RS-485 No. 0 Non Non RS-485 No. 1 Using an optional Expansion I/O Module to add two additional doors: Door C and Door D Work Mode Door C Door D In Out In Out One-way control RS-485 No. 2 Button inputs RS-485 No. 3 Button inputs Two-way control RS-485 No. 4 RS-485 No. 5 RS-485 No. 6 RS-485 No. 7 Mixed control RS-485 No. 2 Button inputs RS-485 No. 6 RS-485 No. 7 One-way traffic RS-485 No. 2 Non Non RS-485 No. 3 Note: The Work Mode is set by ASKeypad or via Ethernet connection when the Ethernet module is installed. 12
17 3 Installation and Wiring 3.5 Connecting the Power After all wiring is complete, power on the AS200 Controller. Plug one end of the supplied power cable into the 6-pin connector on the power converter, and the other end into the three power connectors on the AS200 Controller module: - Power Connectors: 12V DC +/ - - Door A Power Connectors: Power +/- - Door B Power Connectors: Power +/- The black line of the power cable represents negative (-); the red line of the power cable represents positive (+). Power Cables Door B Door A Output Input Output DC 12V+ DC 12V - Power - Power + Power - Power + Power Converter Power Cables Power on the power converter. Plug one end of the supplied power cable into the 2-pin connector on the power converter, and the other end into the power source. 13
18 14
19 4 AS200 Controller Operation 4. AS200 Controller Operation 4.1 How to reboot AS200 Controller To reboot AS200 Controller: 1. To reboot the AS200 Controller, press the Reset button located at the top right of the AS200 Controller module. 2. To reboot the Ethernet module, press the Reset EN button located in the middle left of the AS200 Controller module. 4.2 How to reset AS200 Controller to factory defaults To reset AS200 Controller, you must first reset the AS200 Controller module and then the Ethernet module if installed. To reset the AS200 Controller module: 1. Plug the ASKeypad to the AS200 Controller. This action is mandatory. 2. Remove the jumper cap from the 2-pin Default jumper. 3. Press the Reset button. 4. Replace the jumper cap back to the 2-pin Default jumper. To reset the Ethernet module: Press and hold the Default EN button for 6 seconds. Default AS200 Controller Values Parameter Value ID 0001 Work mode One-way control IP Password 1234 Username admin 3DES Code
20 4.3 Status LEDs Door A Door B Door C Door D LED Light On Flashing Green LED Door open Alarm: Door held open Yellow LED Door opener active Password Fire detector active Alarm: Tamper sensor active 16
21 5 ASKeypad 5. ASKeypad The ASKeypad is an optional device for an administrator to control and manage the AS200 Controller. An administrator can carry a ASKeypad around to access the AS200 Controllers installed at different locations. 5.1 Installation 1. Open the AS200 Controller cabinet. 2. Flip both clips of the 26-pin connector on the AS200 Controller module. 3. Use the supplied 26-pin ribbon cable to connect the ASKeypad to the connector. Note: The ASKeypad is a hot-swapping product. You can plug or unplug the 26-pin ribbon cable while the AS200 Controller is operating. 17
22 5.2 Setting Parameter The ASKeypad allows you to configure basic settings. 1. Press any buttons on the keypad, select Set Parameter, and press the button. 2. Enter the default password 1234, and use UP and DOWN arrow buttons to select one of these options for setup: Local Time Set: Set the time and specify the time zone of the AS200 Controller. Set AS200 ID: Set the ID of the AS200 Controller. Set Work Mode: Set one mode for control. For details on each mode (One-Way Control, Two-Way Control, Mixed Control or One-Way Traffic), see 2. AS200 Controller Work Modes. Set GV-Reader ID: This option is ONLY required when a card reader is connected to the AS200 Controller through RS-485 connection. Password Change: Modify the password of ASKeypad. 3. If you want to view another option, press the button to return to the main menu. 5.3 Displaying System Information In addition to configuration, you can view the system information of the AS200 Controller. 1. Press any buttons on the keypad, select Display System, and press the button. 2. Use UP or DOWN arrow buttons to select one of these options for setup: Door s Control: Displays the door is currently in one of these access mode: Card / Door s Pass: This mode requires the user presents his card to be granted access OR enters the door s password using the keypad to be granted access. Only Card Mode: This is the default mode. This mode only requires the user to present his card to be granted access. Release Mode: Keeps the door in an unlock status with the reader. Card+Password: This mode requires the user presents his card and then enters the card s PIN code on the keypad. 18
23 5 ASKeypad Door s Event: Displays what kind of event happened at the controlled door. Memory s State: Displays the memory usage of the unit. Capacity: Shows the total number of the events that can be recorded. Note that the number limit of recorded events is 65536, and the system will rewrite the oldest events when the limit is reached. When the AS200 Controller is connected to ASServer, the event data will be uploaded to the server and the buffer of AS200 Controller will be cleared. Used in: Displays the number of events that has been recorded. ID & IP Address: Displays the ID to access AS200 Controller and the IP address of AS200 Controller. Display Version: Displays the firmware version of AS200 Controller. 3. If you want to view another option, press the button to return to the main menu. 19
24 20
25 6 AS200E 6. AS200E The AS200E Controller, equipped with the Ethernet Module, can communicate with ASServer over the network. The following sections describe how to install the AS200E on the network and how to configure the AS200E over the network. 6.1 Installing AS200E on a Network The AS200E Controller is able to support two network environments: Fixed IP and DHCP. Depending on your network, choose Fixed IP for a static IP address, or DHCP for a dynamic IP address such as those assigned by an ISP or other DHCP server Fixed IP Connection If your network environment supports a static IP address, the wiring is illustrated as below: Card Reader LAN or INTERNET AS200E Controller ASServer Door 21
26 To assign the AS200E Controller to a fixed IP: 1. Open an Internet browser, and type the default IP address This dialog box appears. Figure 1 2. In the User Name and Password fields, type default value admin and 1234 respectively. Click OK. This page appears. Figure 2 22
27 6 AS200E 3. In the Machine Name field, name the connected AS200E Controller. 4. Click Disable. Type the static IP address information, including IP Address, Subnet Mask, Default Gateway and Domain Name Server. 5. Click Submit. When the connection is established, the Status field indicates Register Success. Note: If you like to use the domain name instead of IP address, you may use Domain Name Service as well. For details on domain name service, refer to DHCP Connection below DHCP Connection If your network environment is using the dynamic IP address from a DHCP server, please use one of the following DDNS servers to map a dynamic IP address to a static domain name or device name: For LAN connection, GV LocalDDNS Server is provided. For Internet connection, two DDNS servers are supported: GeoVision DDNS Server and Dynamic Network Services Inc. (DynDNS). 23
28 Connection over LAN The GV-developed LocalDDNS Server can map a device name to the varying IP address of your AS200E Controller, by which the ASServer can access the AS200E Controller by the device name. The Local DDNS Server can be installed in either ASServer or a separate computer. The wiring of the LocalDDNS application is illustrated as below. Card Reader LAN (DDNS Server) AS200E Controller ASServer Door Note: The Local DDNS Server can be installed in (1) ASServer OR (2) a separate computer. Installing LocalDDNS Server To install the LocalDDNS Server in a computer, insert the Software CD. It will run automatically and a window appears. Select Install GeoVision V1.0 Access Control System, click GeoVision Dynamic DNS Service and follow the on-screen instructions. After Installation, the program will be minimized to the system tray. 24
29 6 AS200E Configuring AS200E on LAN After running the LocalDDNS Server, configure the AS200E Controller on LAN: 1. Open an Internet browser, and type the default IP address The login dialog box (see Figure9) appears. 2. In the User Name and Password fields, type default value admin and 1234 respectively, Click OK. The Network Configuration page (see Figure 2) appears. 3. Click Enable, and select Send to Local DDNS. 4. In the Server IP field, type the IP address of the LocalDDNS Server. 5. In the Device Name field, keep the default setting or change it to match that of the ASServer. Figure 3 25
30 6. Click Submit to send the information to the LocalDDNS Server. When the connection is established, the Status field indicates: Register Success. Note: The default value of the device name is user. If more than one AS Contorller is connected to the ASServer, assign each device a different name Connection over Internet DDNS (Dynamic Domain Name System) provides another way of accessing the AS200E Controller when using a dynamic IP. DDNS assigns a domain name to the AS200E Controller, so the ASServer can always access the AS200E Controller by the domain name. To enable the DDNS function, you should first apply for a domain name from the DDNS service provider s website. There are 2 providers listed in the AS200E Controller: GeoVision DDNS Server and DynDNS.org. To register at the GeoVision DDNS Server, see the following instructions. For details on DynDNS, please consult them at Card Reader Internet (DDNS Server) AS200E Controller ASServer Door Note: Two DDNS servers are supported: (1) GV Dynamic DNS Server and (2) DynDNS. 26
31 6 AS200E Registering a DDNS Domain Name To obtain a domain name from the GeoVision DDNS Server: 1. In the left menu pane, click Network Setting and click the GeoVision DDNS button (see Figure 2). Or open an Internet browser, and type the web address This page appears. Figure 4 2. In the Username field, type a name. Username can be up to 16 characters with the choices of a ~ z, 0 ~9, and -. Note that space or - cannot be used as the first character. 3. In the Password filed, type a password. Passwords are case-sensitive and must be at least 6 characters. Type the password again in the Re-type Password field for confirmation. 4. In the Word Verification section, type the characters or numbers shown in the box. For example, type i8ucy in the required field. Word Verification is not case-sensitive. 5. Click the Send button. When the registration is complete, this page appears. Figure 5 Note: The registered name will be invalid when it is not used for one month. 27
32 Configuring AS200E on Internet After registering a domain name on the DDNS Server, configure the AS200E Controller on Internet: 1. Follow the Steps 1 to 2 in Fixed IP Connection. The Network Configuration page appears. 2. Click Enable, and select Send to DDNS. 3. Type the information of Host Name, User Name and Password that are registered on the DDNS Server. If you select GeoVision DDNS, the system will automatically bring up the Host Name. Figure 6 4. Click Submit to send the information. When the connection is established, the Status field indicates: Register Success. 28
33 6 AS200E 6.2 System Settings You can execute certain system operations, change login password and view the version information of the firmware System Setup In the left menu pane, click Other Setting. This page appears. Figure 7 3DES Code 1-3: Stands for Triple DES (Data Encryption Standard). Type up to three different keys for data encryption. The default 3DES Code1 is Device Port: Keeps the default value Or modify it to match that of the ASServer. Mac Address: Indicates the MAC address of the network medium. Firmware Version: Indicates the current firmware version of the AS200E Controller. Reboot System: Performs a warm boot of the AS200E Controller. This operation will keep the current configuration. Default Value: Resets all configuration parameters to their factory settings. This may take 5 seconds to complete. 29
34 6.2.2 Updating Firmware To update the firmware of the AS200E Controller: 1. In the left menu pane, click Firmware Update. This page appears. Figure 8 2. Click the Browse button to open the firmware file (*.bin) 3. Click the Upload button. This update procedure may take 60 seconds to complete. 4. When the Update is complete, a dialog box appears and asks you to reboot the system. Figure 9 5. Click OK. The AS200E Controller starts the Reboot operation. Note: It is required to reboot the AS200E Controller after updating the firmware. Without rebooting, the firmware update is not complete. 30
35 6 AS200E Changing Login ID and Password To change the login ID and password: 1. In the left menu pane, click Security Setting. 2. On the Security Configuration page, modify the login name and password. The password is case sensitive and is limited to 4 characters with the choices of a ~ z and 0 ~ 9. Figure Setting Controller ID and Work Mode The setting page allows you to modify the ID of AS200E Controller and set one work mode for control. For details on each mode (One-Way Control, Two-Way Control, Mixed Control or One-Way Traffic), see 2. AS200 Controller Work Modes. Figure 11 31
36 32
37 7 Specifications 7. Specifications Model (Default) CPU User Card Number Event Buffer Power Reader Port AS200 8 Bit RISC Microprocessor 10,000 Cards 65,536 Events and Log Data 100~250V AC, 50~60Hz 4 Wiegand Interfaces and External RS-485 for GV-Reader 26~40 Bit Format Wiegand Interface 12V DC Power Supply Red LED, Green LED and Beeper Control Communication Door Number Sensor Port (every door) Output Device (every door) LED Indicator (every door) Operating Temperature Operating Humidity Dimensions Weight Certification RS-485 (Max. 255 Channels) 2 Doors Exit Button / Door Sensor / Fire Sensor / Reader Tampered Electric Lock / Alarm Device / Emergency Device 3 LED Indicating Door s Sensor State and Door s Event 0~65 C (32 ~ 149 F) 10% ~ 90% RH (Non-Condensing) 300 (W) x 420 (H) x 50 (D) mm 4 Kg CE, FCC, RoHS Optional Product ASKeypad Door (Total) TCP/IP Module 2 Lines x 16 English Characters for AS200 Operation 4 x 4 Key for AS200 Operation GV-Extension I/O Module (4 Doors) GV-Ethernet Module 33
38 8. Troubleshooting The card reader does not respond after being installed. If the card reader does not respond, it may be due to the power problem. Try these steps: 1. To verify the problem, remove the paper covered on the AS200 Controller module and check if the power light of the card reader is ON. 2. If the card reader is connected over a long distance, use two additional resistors of 10K ohms to solve the problem. Insert one resistor between D0 and 12V and insert the other resistor between D1 and 12V. GND BZ RL GL D1 D0 12V Power Light 10K 10K Resistor I cannot reset AS200 Controller to factory defaults. 1. Make sure you have plugged the ASKeypad to the AS200 Controller. 2. If the Ethernet module has been installed, make sure also to reset the Ethernet module. 34
The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.
GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O
More informationContents. GV-I/O Box 8 Ports Key Features Compatible Software Packing List Overview DIP Switch...
Contents GV-I/O Box 8 Ports...2 1. Key Features... 2 2. Compatible Software... 2 3. Packing List... 2 4. Overview... 3 5. DIP Switch... 3 6. Connections to PC... 4 6.1 Installing USB Driver... 5 6.2 Assigning
More informationGV-AS Controller. Installation Guide
GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.
More informationGV-Card Reader. User s Manual
GV-Card Reader User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. READER-B 2016 GeoVision, Inc. All rights
More informationGV-I/O Box 4E. Contents
GV-I/O Box 4E Contents 1.1 Key Features... 2 1.2 System Requirements... 2 1.3 Packing List... 2 1.4 Overview... 3 1.5 Connecting to PC... 4 1.5.1 RS-485 Wiring... 4 1.6 Assigning Device ID to GV-I/O Box
More informationGV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C
More informationGV-I/O Box 8 Ports. Overview. Key Features. System Requirements. Packing List. DIP Switch
GV-I/O Box 8 Ports Overview The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both and output voltages. Key Features 8 inputs and 8 outputs are provided. Up to 9 pieces of GV-I/O
More information5.5 AS Layout. GeoVision Technical Handbook 77
5.5 AS400 5.5.1 Layout GeoVision Technical Handbook 77 5.5.2 Wiegand Reader Connection AS400 supports up to eight Wiegand 26 ~ 64bit readers Wiegand connection has a distance limitation of 30m (~ 100ft)
More informationGV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASEV-H 2016 GeoVision, Inc. All rights
More informationQuick Start Guide. GV-CS1320 Camera Access Controller
Quick Start Guide GV-CS1320 Camera Access Controller Thank you for purchasing GV-CS1320 Camera Access Controller. This guide is designed to assist the new user in getting immediate results from the controllers.
More informationQuick Start Guide. GV-AS / EV Controller
Quick Start Guide GV-AS / EV Controller Thank you for purchasing GV-AS / EV Controller (GV-AS100 / AS110 / AS120 / AS210 / AS400 / AS410 / AS810 and GV-EV48). This guide is designed to assist the new user
More informationTechnical Manual Nova: Cabinet Security Management System (CSMS)
Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova
More informationGV-IP Decoder Box Plus User s Manual
GV-IP Decoder Box Plus User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. DBPV10-UM-A 2015 GeoVision, Inc.
More informationINSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3
INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4
More informationGV-RK1352 and GV-R1352 Card Reader
GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured
More informationFinger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot
Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches
More informationQuick Start Guide. GV-Video Server. 1 Introduction. Packing List
Introduction Quick Start Guide GV-Video Server Welcome to the GV-Video Server Quick Start Guide. In the following sections, you will learn about the basic installations and configurations of the GV-Video
More informationGV-Keyboard. User's Manual V2.0
GV-Keyboard User's Manual V2.0 Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2007 GeoVision, Inc. All rights reserved.
More informationQuick Start Guide. 1 Introduction. GV-Box Camera GV-BX120D / 220D / 320D. Packing List
1 Introduction Welcome to the GV-Box Camera Quick Start Guide. In the following sections, you will learn about the basic installations and configurations of the GV-Box camera (GV-BX120D / 220D / 320D).
More informationQuick Start Guide. GV-Video Server
Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist the new user in getting immediate results from the GV-Video Server. For advanced information
More informationNET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2
NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission
More informationStartup Guide. NetAXS-123. Version 5.2
NetAXS-123 Startup Guide Version 5.2 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)
More informationAR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description
SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud
More informationQuick Start Guide. GV-Fisheye IP Camera. 1 Introduction. Packing List
1 Introduction Welcome to the GV-Fisheye IP Camera Quick Start Guide. In the following sections, you will learn the basic installations and configurations of GV-Fisheye IP Camera. For the detailed user
More informationGV-I/O Box 4 Ports V1.0 / V1.1
GV-I/O ox 4 Ports V1.0 / V1.1 small but a capable device, the GV-I/O ox 4 Ports provides 4 inputs and 4 relay outputs. It supports both DC and C output voltages, and provides a US port for PC connection.
More informationPoseidon 4002 MANUAL
Poseidon 4002 MANUAL Poseidon 4002 MANUAL POWER input 12VDC supply (jack or terminals) INPUTS Binary inputs 1 6 (for contacts) OUTPUTS Two 50V rated switchover relay contacts ETHERNET 10 or 100/10 Mbps
More informationNCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL
NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT
More informationUser Manual. Before using this device, read and follow all instructions for safety
User Manual Before using this device, read and follow all instructions for safety Copyrightc 2014 KJTECH Co., Ltd. All rights reserved. It is provided for informational purposes only in this manual. All
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationAccess Control Integration Host User s Manual
Access Control Integration Host User s Manual V1.1.0 Table of Contents 1 1 Overview... 0 2 Device Structure and Installation... 1 3 System Strcuture... 5 3.1 System Structure... 5 3.2 Wiring... 5 4 Function
More informationNCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL
NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT
More informationBF-630X/BF-830X WEB SCREEN. Access Control/Time Attendance. User s Manual
BF-630X/BF-830X Access Control/Time Attendance WEB SCREEN User s Manual Table of Contents CHAPTER 1 INSTALLATION... 2 Requirement...2 Procedure...2 CHAPTER 2 WEB SETUP DESCRIPTION... 3 Login Web...3 Preparation...3
More informationSynergis Master Controller 2.2 Integration Guide for Axis Interface Modules
Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules This guide supplements the Synergis Master Controller Configuration Guide and explains how to configure Axis interface modules
More informationQuick Start Guide. GV-Video Server
Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist new users in getting immediate results from the GV-Video Server. For advanced information on
More informationINDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor
Innovative Electronics for a Changing World NPM-R10-SNMP Remote Network Power Monitor Optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM BATTERY CONNECTIONS 3. SERIES CONNECTED BATTERIES
More informationCRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09
CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.
More informationILF-100WD User Manual. Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending
ILF-100WD User Manual Router Watchdog / Connection Monitor 2007 Stealth Laboratories, LLC Patent Pending Rev. 1.17 02/24/2009 Table of Contents Installation and Configuration...3 Network Configuration...4
More informationC5S120 Installation and Connection Guide
C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before
More informationInnovative Electronics for a Changing World INDEX
Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.
More informationFingerprint Access Standalone User s Manual
Fingerprint Access Standalone User s Manual V1.1.1 1 Table of Contents 1 Overview... 1 2 Device Structure and Installation... 2 2.1 Device Structure... 2 2.2 Device Installation... 3 3 System Structure...
More informationACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:
ACCESS CONTROL QUICK INSTALL GUIDE tel: +44 (0)1457 874 999 fax: +44 (0)1457 829 201 email: sales@cop-eu.com web: www.cop-eu.com WIRING CONFIGURATION - ACS CONTROLLERS CONNECTIONS Dahua access controllers
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More informationInstallation Guide. Avigilon ACM Embedded Controller
Installation Guide Avigilon ACM Embedded Controller 2016, Avigilon Corporation. Portions 2003-2014 HID Global Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER and ACM
More informationROHS AND WEEE COMPLIANCE
210Z ROHS AND WEEE COMPLIANCE All lead-free products offered by the company comply with the requirements of the European law on the Restriction of Hazardous Substances (RoHS) directive, which means our
More informationInstallation Instructions (KF-2000)
VERSION 2005. 10 Installation Instructions (KF-2000) Keico Hightech, Inc. Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone +82-2-853-9000 Fax +82-2-830-7809
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationGV-Joystick. User's Manual
GV-Joystick User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. JKV10-C 2012 GeoVision, Inc. All rights reserved.
More informationAccess control panel U-Prox IC E (Elevator control)
1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter
More informationSuprex Ethernet SPX-7200 Ethernet Reader-Extender
Suprex Ethernet SPX-7200 Ethernet Reader-Extender Product Manual 1 SPX-7200_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems
More informationIndustrial Serial Device Server
1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device
More informationSingle Door Standalone Access Control User Manual
Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self
More informationHIGH STORAGE MODELS WITH CD-RW DRIVE
208 CPD HIGH STORAGE MODELS WITH CD-RW DRIVE CPD505HC_CPD507HC_QUICK_V1.2 1. OVERVIEW 1.1 Product Description With the high storage capacity feature, this MPEG-4 DVR model is designed to accommodate up
More informationProgramming through Web browser:
Connection Details Digital Inputs: There are 8 isolated digital inputs. Digital inputs will work from 5V to 24V DC. Every input has LED indications on top. LED will be ON when proper input is provided.
More informationWiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:
Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact
More informationHardware Installation
LOLM366912 The ipio-8 is a network attached, IP addressed digital input and output device. The ipio-8 can be controlled and monitored with a standard web browser. Multiple ipio-8 devices can communicate
More informationIPassan Installation guide
IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...
More informationQuick Start Installation Guide
istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers
More informationF3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K
F3102 / F3107 / F3110 / F3115 / F3210 / F3215 86085K3000020 PN: 86085K3000030 Zavio F3102/F3107/F3110/F3115/F3210/F3215 Quick Installation Guide Please follow the installation steps below to set up F3102
More informationSPX-7200 Series SPX-7200 EXP Operations Manual. Suprex Reader Extender - Ethernet SPX-7200_MAN_082112
SPX-7200 Series Operations Manual Suprex Reader Extender - Ethernet SPX-7200 EXP-2000 SPX-7200_MAN_082112 Cypress Suprex SPX-7200 Series Overview This manual covers the operation and setup of the Cypress
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationPortals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16
PROS LITE User Manual Version 2.0.0 www.visual-plus.com Table of Contents Getting Started 5 Starting PROS Lite 5 Create a Portal 5 Adding a control panel 6 Adding a user 7 Upload users to a controller
More informationSerial to Ethernet Converter
Serial to Ethernet Converter User s Manual Version 1.1 2004 Infosystem Technology Corporation Disclaimers The information in this manual has been carefully checked and is believed to be accurate. Infosystem
More informationUser Manual Anybus Serial Server
User Manual Anybus Serial Server Rev. 1.20:1 HMS Industrial Networks AB Germany Japan Sweden U.S.A UK + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 + 44 (0) 1908-359301 ge-sales@hms-networks.com
More informationCP150B Vandal & Weather Resistant Keypad Security Systems
Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected
More informationACTpro Single Door IP Controller. Operating & Installation Instructions
ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control
More informationwificam User's Guide Report Version: Date: November
User's Guide Report Version: 2.0.3 Date: November 9 2004 3JTech Co., Ltd. 342 Fu-Hsing N. Rd., 2F Taipei, Taiwan Tel: +886-2-2500 6919 e-mail: info@3jtech.com.tw 1 Revision History Version Date Changes
More informationQuick Start Guide GV-Panoramic PTZ Camera
Quick Start Guide GV-Panoramic PTZ Camera Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. PPTZV10-QG-A 2016 GeoVision,
More informationPoseidon MANUAL
Poseidon2 3266 MANUAL Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested and is supplied
More informationINDEX. Network Power Monitor R10 SNMP
Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX Amended 21 March 2017: Add user defined Password see page 13 Add wire Connection
More informationW Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2
W Series Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W1 & W2 Features * Standard 2.8-inch TFT LCD, 512MB Flash, industrial high speed CPU * Touch keypad & touch active sensor
More informationEMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual
EMC-1 TM Ethernet Meterbus Converter Installation and Operation Manual DIMENSIONS [inches (millimeters)] 4.85 ( 123 ) For the most recent manual revisions, see the version at: www.morningstarcorp.com 3.37
More informationUser Manual A08. User Manual
A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...
More informationInstallation Guide V8.3
Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. Installation Guide V8.3 2009 GeoVision, Inc. All rights reserved. Under
More informationQuick Installation Guide
Quick Installation Guide DL-200 Cellular Data logger V1.2_201610 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 4 1.1 CONTENTS LIST... 5 1.2 HARDWARE INSTALLATION... 6 1.2.1 WARNING... 6 1.2.2 SYSTEM REQUIREMENTS...
More informationF18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed
F18 Features: 1. 2.4 TFT LCD color screen 2. Standard Wiegand Input and Output interfaces are compatible with most all 3 rd party 26 bit Wiegand readers and access control panels. 3. USB HOST port makes
More informationAccess Control System Document Number: , Rev. D. Installation Guide. Essential Essential Plus Elite 36 Elite 64
Essential Essential Plus Elite 36 Elite 64 Access Control System Document Number: 620-100239, Rev. D Installation Guide USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800)
More informationKey Switch. Document version: 1.5 (Updated 02 May 2017)
Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationC1002 IP Camera. Quick Installation Guide. Solwise Ltd., 1
C1002 IP Camera Quick Installation Guide Solwise Ltd., www.solwise.co.uk, sales@solwise.co.uk 1 Trademarks and/or registered trademarks are the property of their respective owners The information presented
More informationGLOSSARY. See also: Access point
GLOSSARY A Access level A set of access points, each with a corresponding time schedule, that determine where and when a badge holder has permission to pass through an access point. See also: Access point
More informationConnecting a Cisco Reader Module
CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco
More informationAvantis AXI WEB SERVER MODULE USER MANUAL
Avantis AXI WEB SERVER MODULE USER MANUAL CONTENTS CHAPTER 1: SYSTEM LOGIN AND WEB PAGE LAYOUT 1.0 ACCESSING THE WEB PAGE 1.1 USER AUTHORITY 1.1.1 MASTER USER 1.1.2 USER/ GUEST SETTING 1.1.3 INSTALLER
More informationKnowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers
Knowledge Base Article Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Copyright 2009-2013 ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION...
More informationGV-IR LED. User's Manual
GV-IR LED User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2010 GeoVision, Inc. All rights reserved. Under
More informationDocking Station DS-U4WEB with web server version 1 Instruction Manual
Page 1 of 15 Docking Station DS-U4WEB with web server version 1 Page 2 of 15 Table of contents 1 Overview... 3 2 Description... 3 2.1 Connector identification... 3 2.2 Probe inputs... 4 2.3 Logical inputs
More informationPoseidon MANUAL
Poseidon2 4002 MANUAL www.hw-group.com 2 Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested
More informationIP Apartment System Quick Start Guide
IP Apartment System Quick Start Guide Version 1.0.0 Welcome Thank you for purchasing our device! This quick start guide will help you become familiar with our device in a very short time. Before installation
More informationWebpass IP Reader. WEB Configuration Manual
Webpass IP Reader WEB Configuration Manual WEBPASS version : v0.09 Aug-24 th -2009 (HW.1.0) WEBPASS Web version : v1.4 Build date : Aug-18 th -2009 Revision History 1. Newly added Event Type : Alarm and
More informationGV-I/O Box 4 Ports V1.2
GV-I/O Box 4 Ports V1.2 small but a capable device, the GV-I/O Box 4 Ports V1.2 provides 4 inputs and 4 relay outputs. It supports both and output voltages, and provides a USB port for P connection. Key
More informationWelcome. Unleash Your Phone
User Manual Welcome Unleash Your Phone For assistance with installation or troubleshooting common problems, please refer to this User Manual or Quick Installation Guide. Please visit www.vonage.com/vta
More informationQUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.
More informationACX Series. Access Controller for Ethernet
Access Controller for Ethernet The controllers are the industry s most powerful all-in-one access controllers designed for both critical government and private sector security applications. 0 Features
More informationDS-K2600 Series Access Controller. Quick Setup Guide. Ness V1.0
DS-K2600 Series Access Controller Quick Setup Guide Ness V1.0 This is a Quick Setup Guide for Ness Version of Hikvision DS-K2604 4 Door Access Controllers. For full details refer Ness Full User Manual
More informationQuick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0
Quick Start Guide ProBio & ProFAC + ZKBioSecurity 3.0 CONTENT 1 Safety Precautions...2 On Using Face Recognition Device...3 Device Overview...5 Product Dimensions & Installation...6 Power Connection...7
More informationACTpro 1500 Single Door IP Controller
ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply. Operating & Installation Instructions 18-00085 Issue 2 This manual refers to the ACTpro 1500
More informationGV-ASManager. User's Manual V1.1
GV-ASManager User's Manual V1.1 2008 GeoVision, Inc. All rights reserved. Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of GeoVision. Every effort
More informationAccess Control Unit User s Guide
NetAXS Access Control Unit User s Guide The configurations described in this document have not been reviewed by Underwriters Laboratories Inc. June 2007 2007 Honeywell. All rights reserved. 800-00233,
More informationInstallation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT
Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,
More informationGUIDE. EIPR Skorpion IP Router EIPR
a p p l i c a t i o n GUIDE EIPR EIPR Skorpion IP Router The EIPR links two Internet Protocol (IPv4) networks together passing appropriate traffic while blocking all other traffic. One of the networks
More information900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note
*44487080* 44487080 DANGER To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board. 900- Option Board Installation Instructions 900- Specifications Inputs
More information