Technical Data Sheet OPUS A8 ECO Full

Similar documents
Technical Data Sheet OPUS A8 ECO Basic

Technical Data Sheet OPUS A6 ECO Full

Technical Data Sheet OPUS A3 ECO Full

Technical Data Sheet OPUS A6 ECO Basic

Technical Data Sheet OPUS A8 STANDARD Full TDS OPUS A8sF,

Technical Data Sheet OPUS A6 STANDARD Full

Technical Data Sheet OPUS A3 STANDARD Basic

Technical Data Sheet OPUS A6 ECO Full TDS OPUS A6eF,

Technical Data Sheet OPUS A6 ECO Basic TDS OPUS A6eB,

Technical Data Sheet OPUS A6 STANDARD Full TDS OPUS A6sF,

Technical Data Sheet OPUS A6 ECO Basic TDS OPUS A6eB,

Technical Data Sheet OPUS A3 ECO Full

Technical Data Sheet OPUS A6 ECO Basic

Technical Data Sheet OPUS A6 STANDARD Full

Technical Data Sheet OPUS A3 STANDARD Full

MultiViu Flex 4 Data Sheet

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

Technical Data Sheet OPUS A3 ECO Basic

Technical Data Sheet OPUS A3 ECO Basic TDS OPUS A3eB,

I /O. OPUS A6s - For Perfectionists IP 65 IP "

Operating Manual HMI 4 HMI 4. Operating Manual Hardware Description INTER CONTROL GmbH & Co. KG

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 7 WVQA Sunlight Viewable Display

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

2 Control Equipment for General Applications

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

DSEM870. DSEControl PROGRAMMABLE DISPLAY FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY

Control Panel CP600-eCo CP604, CP604-B

IRMA MATRIX Release 2

Control Panel CP600 CP635, CP635-B, CP635-WEB

CCD1100S. Technical Data Sheet

IPCB42501 / IPCB42551

MRS Electronic GmbH. Datasheet CAN I/O & CAN PLC CAN I/O & CAN PLC. CAN I/O & CAN PLC Site 1 of 5 Version 1.0

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Control Panel CP600 CP651, CP651-WEB

Control Panel CP600 CP635-FB, CP635-FW

F1000 User's Manual. (Version: V1.01)

Operating instructions. Speed monitor D / / 2014

Operating instructions. Switching amplifier DN0210 DN / / 2015

CDC2000X. Technical Data Sheet

Inclination sensors 2-dimensional, measuring range up to ±90

DINALOG A 144 x 36 A1400 Light-Strip Indicator

NOVOHALL Transducer 5 up to 50 mm touchless. Series TFD-4000

LED W RGBA User Manual

Inclination sensors 1-dimensional, measuring range

General Operating, Maintenance and Installation Manual

MP211 HARDWARE MANUAL

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Absolute Encoders Multiturn

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

PCAN-TJA1054 Bus Converter High-Speed CAN to Low-Speed CAN. User Manual. Document version ( )

Faults on the system Proximity switch connection technology:

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Inclinometer. 4-20mA and RS232

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

Strain Gage Measuring Amplifier GSV-3

D E C E M B E R

USER MANUAL. For XLCD17-LED XLCD19-LED

L-LAS Series L-LAS-LT-55. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-55 (incl. Windows - software L-LAS-LT-Scope)

AMG 11. Features. Optional. Additional incremental output (TTL / HTL) AMG 11. Technical data - mechanical design. Technical data - electrical ratings

Operating instructions. Standstill monitor A / / 2011

AI561 Analog Input Module

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Electronic Control Unit RC

Linear Position Transducer HLT 1000-R2

Hardware Manual RM Display 2501 S01..S04

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

Features. Intel 45nm Atom Processor N270: 1.6 GHz

Installation instructions Process and dialogue module PDM360 NG CR1080 CR9223 CR1081 CR9224 CR CR1084 CR9226 CR1085 CR9227

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

CCPILOT PRODUCT CATALOG 2018 AN ACTUANT COMPANY

INSTRUCTION MANUAL. Tel. Fax. +49 (0) 4154 / (0) 4154 / Internet.

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

PX Series Balances. Quick Start Guide. Please download the user manual from

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

DRTS 66 can test all the following relays

USER MANUAL. User Manual 17 / 19 LCD. NVP117 / NVP119 1U LCD Console Drawer. Options : - AV / DVI-D / HDMI / Audio - Full Range KVM - DC power

TM221ME32TK controller M IO transistor PNP Ethernet

MCX06C Programmable controller

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

TF501, TF521 Terminal Bases

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

HMG 11. Features. Optional Additional incremental output (TTL / HTL) HMG 11. Technical data - mechanical design. Technical data - electrical ratings

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

MODEL 805 USER MANUAL

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Mounting holes. Transmitter optics. 8-pol. fem. conn. Binder Series 712 (connection to PLC) Connecting cable: cab-las4/pc or cab-4/usb or cab-4/eth

GV204 Impulse Splitter for Incremental Encoders

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

L-LAS Series. L-LAS-TB-F-6x1-40/40-CL L-LAS-TB-F-1x6-40/40-CL. Design. L-LAS Series Laser Line Sensors. Product name:

Professional and Versatile 24" LED Monitor

PowerView Model PV485. Installation Manual Section 78

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

Hardware Manual RM Display 2401

TM221CE40R controller M IO relay Ethernet

Transcription:

Technical Data Sheet OPUS A8 ECO Full 21.09.2017 Errors and technical changes excepted

1 Notes and Warnings Attention! This description is not a substitution for the concerned product s documentation. Please do read the documentation including the manuals carefully before dealing with this product. If the safety instructions in the documentation are not followed dangerous situation can occur that can result in damages, injuries and/or death by high voltage or wrong handling. In case you do not have the correct documentation you can order it by contacting dl-opus-info@topcon.com. Only properly trained personnel with the correct qualification are allowed to handle the device. Attention! Do not open the housing to avoid danger to high voltages. Before touching the electric assemblies make sure that the electricity is switched off completely. If the front pane is broken the device needs to be taken out of service due to risk of injury. If perceivable damages on the device exist that can compromise the functionality, it must be taken out of service due to the danger of malfunctions. These particularly include damages to the LCD display, damages to the keyboard, damages that compromise the protection level and damages to the encoder knobs. Please note: All content is subject to change without notice. Errors and omissions excepted. Mounting and Handling 1. Do not use the cable as a handle to carry the device. 2. Mounting in clean working environment only. Dust and oil can harm the electric contacts and compromise the functionality.. Do not mount the device under the use of violence because it can cause damage.. The device must be mounted by trained personnel only into especially designed and tested systems. 5. The device must not be opened or disassembled. 6. The device is to be cleaned with a moist fuzz free cotton cloth. If necessary a mild cleaning agent can be used. Do not use acid or abrasive cleaning agents. 7. The device is to be stored in a cool and dry environment and to be protected against sun shine. 8. If the environmental temperature is beneath 10 C the reaction time of the display increases. 2 General Information Order Numbers This documentation is valid for OPUS A8 order numbers as follows: OPUSA8EN1CANF000 OPUSA8EN1CDSF000 OPUSA8EN1ISOF000 OPUS Projektor CoDeSys ISO-VT

Dimensions Housing Aluminium back-housing, plastic front-housing, colored light grey (RAL 705) with black rubber frame. Mounting Landscape or portrait Standalone In-dash

Display Type: TFT Color Graphic LCD with LED backlight Size: 12.1, 261 mm (W) x 16 mm (H) Resolution: 1280 x 800 px (WXGA), 16:10 Colors: 2 bit Brightness: typ. 00 cd/m² Contrast Ratio: typ. 1,000:1 Input Devices Touch PCT Indicators and Sensors Light sensor 1 Multicolor-LED Status-LED s 5 Electronics Processor platform CPU: Mass storage: 8 GByte RAM: RTC: Speaker Power supply Freescale I.MX6, quad core, 1 GHz 102 MByte Buffered by gold cap 80 db(a) in 1m distance @ 1 khz Operating voltage range: 9 6 V DC Protection: Short circuit protection Overvoltage resistance: 8V for max. 5 minutes Inverse polarity protection: Up to -8 V DC for max. 5 minutes Current consumption (without external load), max. Power Mode On Low-power Sleep Off Current at 1,5 V DC Current at 27 V 1,8 A 0,7 A Depending on config 0,2 A 0,1 A 2 ma ma

6 Interfaces CAN Bus 2 x CAN-Interfaces ISO 11898, CAN-specification 2.0 B active Up to 1 Mbit/s (default 250 Kbit/s, 500 Kbit/s, 750 Kbit/s and 1 Mbit/s) RS22 1 x RS22-Interface Type: EIA22 (only RxD, TxD, GND) Speed: max. 115 Kbps USB Main connector: Inputs 1 x High speed configurable analog/digital inputs Input impedance: > k Ohm Resolution: 10 bit (102 digits, 1 digit = 11,7 mv) Input range: 0 12 V, -20 ma, 0-20 ma Max. protectable input voltage: 6 V DC Protection: Short circuit protection Frequency: Max. signal frequency 50 Hz Outputs digital outputs Short circuit protection: Up to 6 V I max 00 ma open drain at 12V R DS,on < 1 Ohm > 100 kohm R DS,off Audio 1 x Audio output (left, right, GND) AC97 compatible Output power: approx. 65 mw @ 2 Ohm Video-Interface analog video inputs, 1 V ss 2 live streams Camera control output (open drain) for special functionality (mirror, shutter, heating etc.), 00mA @ 12V DC Ampacity 500mA @ 12V DC Ethernet-Interface 1 x 10/100 Mbit/s Base T 7 Connectors Connectors Main: Tyco-AMP -17290-7 Video: M12 round connector, female, 5-pole, B-coded acc. to EN 61076-2-101 Ethernet: M12 round connector, female, -pole, D-coded acc. to EN 61076-2-101

8 Software Operating System Linux.x Application Programming OPUS Projektor Optional: Codesys-Tools (.5) Optional: ISO-VT Optional: C/C++ 9 Testing and Verification CE-Compliance EU Directive 201/0/EU (EMC) according to EN 12895: Industrial Trucks Electromagnetic compatibility EN 109: Construction machinery Electromagnetic compatibility of machines with internal electrical power supply EN ISO 1982: Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteria E1 - Type approval EU Directive ECE R10 Protection Level (IP Code) IP 65 and IP 66 according to ISO 2065: Road Vehicles Degrees of protection (IP-Code) Protection of electrical equipment against foreign objects, water and access Electrical 12 and 2V-Systems according to: ISO 16750-2: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Electrical loads ISO 1500: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions Mechanical According to ISO 16750-: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Mechanical loads, Code L ISO 1500: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions Mechanical Shock: Level 2 Random Vibration: Level 2 Sinusoidal Vibration: Level 2 Climate ISO 16750-: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Climatic Loads Operating Temperature Range: -0 +65 C Storage Temperature Range: -0 +85 C ISO 1500: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions

10 Pinout Main connector pinout Pin. No. 1 2 5 6 7 8 9 10 11 12 1 1 15 16 17 18 19 20 21 22 2 2 25 26 Assignment VCC Ignition Input GND CarGND AUDIO_L AUDIO_R AUDIO_GND CAN1H CAN1L CAN2H CAN2L USB_VCC USB_GND USB_D- USB_D+ RS22 RxD RS22 TxD RS22 GND A/DI A/DI1 A/DI2 A/DI or WoI SERV_EN DO DO1 DO2 Description supply voltage +; terminal 0 ignition input; terminal 15 supply voltage - ;terminal 1 Car GND AUDIO_L AUDIO_R AUDIO_GND CAN 1 high CAN 1 low CAN 2 high CAN 2 low USB +5V supply USB supply GND USB Data - USB Data + RS22 receive data RS22 transmit data RS22 GND analog/digital input analog/digital input 1, full frequency analog/digital input 2 analog/digital input service enable digital/analog output digital output 1 digital output 2 View on rear side of the A8 1 7 8 1 1 19 20 26

Video connector pinout Ethernet connector pinout 1 2 5 Round Connector, 5 pins, M12 VidSig+ Mirror Camera+ Camera - VidSig GND 1 2 Round Connector, pins, M12, acc. To IEC 61076-2-101 TD+ RD+ TD- RD- Video connector, M12, female, 5 pins, b-coded, view on rear side of the A8 Ethernet connector, M12, female, pins, d-coded, view on rear side of the A8 1 2 1 2 5