Assembly instruction / User manual

Similar documents
Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions. Speed monitor D / / 2014

Industrial motor controller for brushed DC motors 24 VDC

Operating instructions. Switching amplifier DN0210 DN / / 2015

Industrial motor controller for brushed DC motors 24 VDC

Operating and Maintenance Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

Operating instructions. Standstill monitor A / / 2011

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Operating Instructions Control Units for Belt Drives

MC 11 EB-2 Power supply cabinet with external bus, AC version

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

QUINT-BUFFER/24DC/24DC/40

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Rhino PSM Power Supplies. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Operating Instructions Differential Pressure Transducer PS27

SMVector Additional I/O Module Installation and Operation Manual

MINI MCR-SL-UI-REL(-SP)

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Solid State Remote Power Controller E /627

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Instruction Manual for 1-Phase 1Q-Power Controller Temvar GE_3

Controller Smart Box Translation of operating and installation instructions

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Model Number Structure

Power Supply HARTING pcon

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Installation Requirements for Conformance to Standards

Output Voltage* (nom.)(adjustable)

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

MINI-PS AC/10-15DC/8

2-PHASE STEPPING MOTOR DRIVER FE Z4 TRANSFER

VP ELECTRONIQUE MASSY - Tel

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Power Supply HARTING pcon

signo 727 SSI operating instructions

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

GS202 Encoder Switch

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

External level devices for conductive point level switch

USB I/O-CARD WITH 32 INPUTS

Installation, Operation and Maintenance Instructions

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Multifunctional time delay relay MFT U31S, MFT U41SE

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

MINI MCR-SL-CVS NC

Installation instructions Inclination sensor EC2019 EC / / 2013

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

USER MANUAL. WBV412U01 AC voltage transducer

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Faults on the system Proximity switch connection technology:

DENISON HYDRAULICS Jupiter Power Supply Accessory Series S

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Output Voltage* (nom.)(adjustable)

Switched Mode Power Supply Operating manual PAP800

Operating instructions Evaluation system for flow sensors VS / / 2013

Enclosed Power Supplies

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

Industrial Power Supplies

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Light Control SLS ADRIA

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Universal Power Supplies

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Content. Time delay relays mounting position. Multifunctional time delay relay Clock-pulse generator time delay relay... 3.

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

RТTH DUAL ROOM SWITCH

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Manual Control Unit GFC 32

Elo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum:

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

USER MANUAL. WBI412F41 AC current transducer

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Operating Instructions

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Transcription:

Assembly instruction / User manual 4-Q motor speed control unit digital, type DLR 24/xx-466 Technical data under reserve technical changes Please read these instruction before using and please keep safe for future. You may download further technical advice under www.eph-elektronik.de. Seite 1 von 10

Table of contents 1. Safety instructions and Safeguarding... 3 1.1. Installation note... 3 1.2. ESD-Protection / Hazard note... 3 2. Getting started DLS24/xx-466 with 19-pole poliger spring clamp terminal... 4 3. Technical feature... 5 4. Technical data... 5 5. Connecting... 6 5.1. Control connections... 6 5.2 Connecting diagram... 7 5.3. Overview DIP switch... 9 6. CE Declaration of Conformity... 9 Seite 2 von 10

1. Safety instructions and Safeguarding 1.1 Installation note An external mains adapter is required for the electrical supply of the speed controller EPH 466. If this mains adapter is itself supplied with a voltage >50V DC or >75V AC the following points have to be considered: The unit should only be installed by qualified specialist personnel. Installation and operation of the unit should comply with the local regulations for electrical installations as well as health and safety regulations. The protection of people and property must be warranted by applying the currently applicable safety regulations (VDE, electrical safety regulations, IEC, etc.). High start-up currents can occur at the moment of tuning on a controller device / mains adapter due to charging process of the intermediate circuit. An effective safeguard is therefore required on the mains input side (e.g. a C-Rated 16A line circuit breaker). The use of RCD circuit breakers before control unit / mains adapter is not recommended because of the leakage currents generated by EMC interference suppressing devices. The regulator card / mains adapter must not be operated without an effective connection to earth! The connection to earth must comply with local regulations. 1.2. ESD-Protection / Hazard note Attention during installation of the electronic board! Danger to burn - Beware! Danger to fire- Beware! Danger to life-beware! It must be warranted on your part that there is sufficient ESD-protection. Parts of this controller card can be reach a temperature up to 80 C. Increased risk at controller cards without protective cover. Unprofessional handling and installation can cause a fire. Parts of this controller card are under intermediate circuit voltage and remain energised >50VAC respectively 75VDC after turning main power off. Coming into contact with the terminals, lines and unit parts can cause serious injuries or result in death! Seite 3 von 10

2. Getting started DLR24/xx-466 with 19-pole spring clamp terminal 1. Select modes: put jumper 1 on 1-2 for internal speed reference (potentiometer 1) or on 2-3 for external speed reference (for internal reference put jumper 2 on 1-2 for value max. 5V DC) put jumper 2 on 1-2 for speed reference max. 5V or on 2-3 for max. 10V DC target value input. put jumper 3 on 1-2 for 12V motor or on 2-3 for 24V motor. put DIP switch 1 and 2 ON for inverted enables (no need of connecting terminal 15, 16 und 18) put DIP switch 3 to 8 Off 2. Turn potentiometer 2 (Imax) for current limitation to the right position. 3. Potentiometer 3 (IxR) compensation to left position. 4. Connection of the control wires see Connection diagram, page 7. 5. Connect DC motor to terminals 3 and 4. 6. Connect power supply: to terminal 1 Plus (ca. 10 36V DC), to terminal 2 GND. 7. Now turn on power supply. 8. LED green (power on) illuminates on the pcb. 9. With potentiometer 1 (n ref) the speed reference can be adjust from 0 to 100%, if jumper 1 is put on 1-2. 10. Motor direction can be changed witch a voltage (5 36V DC) on terminal 19 (e.g. bridge from clamp 17 to 19) Seite 4 von 10

3. Technical features Power supply Ue: 10V DC 36V DC (with inverse-polarity protection) High frequency f>20 khz, this results in low-noise operation Electric connection via spring clamp terminals High level of effectiveness by using Power Mosfets Mounting: mounted with screws or on a 35mm mounting rail The dispose of this product has to be done via separate electrical- and electronic equipment disposal. 4. Technical data type Supply Voltage Armature voltage U A Armature current I N Mechanical power P ab DLR 24/ 05 10-36V DC 0-12/24V DC 0-5A approx. 75W DLR 24/ 10 10-36V DC 0-12/24V DC 0-10A approx. 150W Model: DLR 24/xx/P: screw mounting DLR 24/xx/M: screw mounting or mounting rail 35mm DLR 24/xx/G: screw mounting or mounting rail 35mm with yellow cover Protection: external fuse: DLR 24/05 5AT DLR 24/10 10AT Environment temperature: 5 to 45 C Relative air humidity: 18% to 85% (non-condensating) Control range: up to 1 : 30 Speed control through EMF control with I x R compensation. Seite 5 von 10

5. Connecting 5.1. Control connections Speed reference value: terminal 11: 5V DC terminal 12: wiper external potentiometer (10kOhm) terminal 13: GND Controller enable 1: terminal 15: Input 5-36V DC Controller enable 2: terminal 16: Input 5-36V DC Speed reference enable: terminal 18: Input 5-36V DC Motor direction: terminal 19: Input 5-36V DC Output 1 (ready for operation) terminal 9: turns on voltage 10V-36V DC (<50mA), when the controller is ready Output 2 (Overload): terminal 10: turns on voltage 10V-36V DC (<50mA), at the current is longer than 3 sec. at the current limit. Resetable by selecting 0V at speed reference value (terminal 12) or disable speed reference (terminal 18) Seite 6 von 10

5.2 Connecting diagram Seite 7 von 10

Seite 8 von 10

5.3. Overview DIP switch Different modes are selectable by using the DIP-switch (mode changes work only, when the power supply is turned off and on). DIP 1 DIP 1 DIP 2 DIP 2 DIP 3 DIP 3 Off ON Off ON Off ON Controller enable not inverted (terminals 15 and 16 must be connected, for working motor in the wanted direction) Controller enable inverted (terminals 15 and 16 must not be connected, for working motor in the wanted direction) Speed ref. enable not inverted (terminal 18 must be connected, for a working ref. Speed value) Speed ref. enable inverted (terminal 18 must not be connected, for a working ref. Speed value) Speed ref. value 0 to 5V/10V means motor voltage: 0 to + +12V/+24V (motor voltage) Speed ref. value 0 to 5V/10V means motor voltage: -12V/-24V to +12V/+24V (half speed value -> motor voltage=0vdc) DIP 4 Off Ramp for motor voltage 1 sec., when DIP5 and DIP 6 are Off DIP 4 ON Ramp for motor voltage 2 sec., when DIP5 and DIP6 are Off DIP 5 Off Ramp for motor voltage 1 sec., when DIP4 and DIP6 are Off DIP 5 ON Ramp for motor voltage 3 sec., when DIP4 and DIP6 are Off DIP 6 Off Ramp for motor voltage 1 sec., when DIP4 and DIP5 are Off DIP 6 ON Ramp for motor voltage 5 sec., when DIP4 and DIP5 are Off DIP 7 Off Motor turns not off after 3 sec. on current limit (motor overload) DIP 7 ON Motor turns off after 3 sec. on current limit (motor overload) DIP 8 Off No function DIP 8 ON No function Seite 9 von 10

6. CE Declaration of Conformity The manufacturer EPH elektronik Produktions- und Handelsgesellschaft mbh Rudolf-Diesel-Straße 18 DE-74354 Besigheim-Ottmarsheim Tel.: +49(0)7143/81 52-0 herewith declares that the product: Product: 4-Q motor control unit digital Type DLR 24/xx/P 466 DLR 24/xx/M 466 DLR 24/xx/G - 466 is conform to the mentioned EC-regulation in connection with the test peripheral devices: Regulation 2014/30/EU EMC-directive The following harmonised standards are applied: DIN EN 55011 VDE 0875-11:2011-04 DIN EN 61000-6-2 VDE 0839-6-2:2006-03 EMI emission EMI immunity The transistor controller`s conformity to the mentioned standards doesn t concern the complete system. An extra EMC-test would be necessary to get the conformity for the complete system. If the transistor controller is integrated in a machine, the machine has to comply with regulation 2006/42/EG (machines directive). If not operating is not allowed. If the supply voltage of the machine is > 50V AC respectively 75V DC, the regulation 2014/35/EC (low voltage directive) is to be observed. Name authorised person: Reiner Mannsperger Address authorised person: see address of the manufacture Professional Competence: manager development Date: 30 th June 2017 Seite 10 von 10