Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Similar documents
Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Speed monitor D / / 2014

Operating instructions. Standstill monitor A / / 2011

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions IO-Link master CabinetLine AL19xx

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions. Monitor FD / / 2013

Installation instructions Ethernet switch EC / / 2011

Operating instructions. Monitor FS-2 / FS-2N / / 2013

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Installation instructions Inclination sensor EC2019 EC / / 2013

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Operating instructions. Monitor FR-1 / FR-1N / / 2013

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Quick reference guide 3D sensor O3D3xx

Operating instructions Monitor FD-2 DR2005 DR / / 2007

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

Operating instructions. Monitor FS-1 / FS-1N / / 2013

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Operating instructions Optical distance sensor. OID20x / / 2014

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Operating instructions Optical distance sensor. OID25x / / 2014

Operating instructions AC010S Compact AS-i E-STOP safety module

Operating instructions. ProcessLine analogue module AC / / 2012

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GI712S

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Optical distance sensor. O5D15x / / 2014

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Operating instructions Optical distance sensor. OID20x / / 2015

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Extension module for lighting control

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

QUINT-BUFFER/24DC/24DC/40

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Hardware Manual RM CANview Gateway

System manual AS-i safety monitor AC041S /00 05/2013

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Assembly and Operating Instructions. M2 module for BDC-i440 control units

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Industrial motor controller for brushed DC motors 24 VDC

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018

PHOENIX CONTACT - 12/2007

Operating Instructions

AS-i Safety Relay Output Module with Diagnostic Slave

Industrial motor controller for brushed DC motors 24 VDC

Operating Instructions

TVAC25100 TVAC25110 User manual

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Hardware Manual RM CANview

Brief instructions Illumination unit O3M /00 09/2014

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Operating instructions Optical distance sensor O1D / / 2012

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

MINI-PS AC/10-15DC/8

Brief instructions Illumination unit O3M950 O3M /00 03/2016

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

MU110-6U. Analog output module 6 channel. User guide

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

MDM 011-Z1 Regen Resistor

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

AS-i Safety Relay Output Module with Diagnostic Slave

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Power manual for MACX Analog, MACX Analog Ex, MACX PL, MINI Analog, and MINI Analog Pro signal conditioners. User manual

Assembly instruction / User manual

Hardware Manual RM Display 2501 S01..S04

PI-EX-ME-2NAM/COC-24VDC

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Operating instructions RFID evaluation unit DTE / / 2011

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PHOENIX CONTACT - 07/2006

Digital Modules AS-i in IP20, 22,5 mm

Hardware Manual RM Display 2401

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

XTM1250SA DIN rail three phase four wire LCD display energy meter

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Transcription:

Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016

Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target group...4 2.3 Electrical connection...4 2.4 Handling...4 2.5 Location...4 2.6 Housing temperature...4 2.7 Tampering with the device...5 3 Functions and features...5 4 Operating and display elements...6 5 Operation / LEDs...6 6 Installation...7 6.1 Installation of the device...7 6.2 Remove the device...7 6.3 Mounting of the sensors...8 7 Electrical connection...8 7.1 Connection accessories...8 7.2 Terminal connection...8 8 Addressing...9 8.1 Addressing with the AC1154 addressing unit...9 9 Technical data...10 9.1 Scale drawing... 11 9.2 Approvals/standards... 11 10 Maintenance, repair, disposal...12 10.1 Servicing...12 10.2 Cleaning the housing surface...12 10.3 Repair...12 10.4 Disposal...12 2

1 Preliminary note This document is intended for specialists. These specialists are people who are qualified by their training and their experience to see risks and to avoid possible hazards that may be caused during operation, installation or maintenance of the device. Read this document before use to familiarise yourself with operating conditions, installation and operation. Keep this document during the entire duration of use of the device. WARNING Adhere to the warning notes and safety instructions. ( 2 Safety instructions). 1.1 Symbols used Instructions Cross-reference Important note Non-compliance may result in malfunction or interference. Information Supplementary note General warning Non-compliance may result in personal injury. 1.2 Warnings used WARNING Warning of serious personal injury. Death or serious irreversible injuries may result. 2 Safety instructions 2.1 General Follow the operating instructions. Non-observance of the instructions, operation which is not in accordance with use as prescribed below, wrong installation or incorrect handling can affect the safety of operators and machinery. The installation and connection must comply with the applicable national and international standards. Responsibility lies with the person installing the device. 3

The system installer is responsible for the safety of the system into which the device is integrated. 2.2 Target group The device must only be installed, connected and put into operation by a qualified electrician. 2.3 Electrical connection Disconnect the unit externally before handling it. Make sure that the external voltage is generated and supplied according to the requirements for safety extra-low voltage (SELV) since this voltage is supplied without further measures near the operating elements and at the terminals for the supply of connected sensors. The wiring of all signals in connection with the SELV circuit of the device must also comply with the SELV criteria (safety extra-low voltage, safe electrical isolation from other electric circuits). If the externally supplied or internally generated SELV voltage is externally grounded, the responsibility lies with the user in accordance with the applicable national installation regulations. All statements in these operating instructions refer to the unit the SELV voltage of which is not grounded. The consumption of current which exceeds the value given in the technical data is not allowed. An external main switch must be installed for the unit which can switch off the unit and all related circuits. This main switch must be clearly assigned to the unit. 2.4 Handling Be careful when handling the unit once power is applied. This is only allowed by qualified personnel due to the protection rating IP 20. 2.5 Location For the correct operation the device must be mounted in a housing which can only be opened using a tool or in a locked control cabinet (both protection rating IP 54 or higher) as an enclosure. 2.6 Housing temperature As described in the technical specifications below the device can be operated in a wide ambient temperature range. Because of the additional internal heating the 4

operating elements and the housing walls can have high perceptible temperatures when touched in hot environments. 2.7 Tampering with the device In case of malfunction of the unit or queries please contact the manufacturer. Any tampering with the device can seriously affect the safety of operators and machinery. This is not permitted and leads to the exclusion of any liability and warranty claims. 3 Functions and features The devices act as digital input and output modules in the AS-i network.they connect max. 4 sensors (2-wire or 3-wire sensors) and max. 4 actuators each with the AS-i master. AC3200: sensor supply via AS-i 200 ma AC3201: sensor supply via AUX 1 A Maximum number of modules per master: 62 (A/B slave) AS-i profile S-7.A.7 The devices can only be operated in conjunction with a version 3.0 master (master profile M4). 5

4 Operating and display elements 4 LED 1 LED 2 3 LED 3 2 1 1. Connector with cage clamps 2. Panel for labelling 3. Addressing socket 4. DIN rail mounting LED 1: switching status indication sensor inputs I1...I4 LED 2: AS-i, FAULT, AUX LED 3: switching status indication actuator outputs O1...O4 5 Operation / LEDs LED 1 yellow LED lights: LED 2 AS-i green lights: LED 2 FAULT red lights: LED 2 FAULT red flashes: LED 2 AUX green lights: LED 3 yellow lights: inputs (I1...I4) switched AS-i voltage supply OK AS-i communication error, slave does not participate in the "normal" exchange of data, e.g. slave address 0 peripheral fault, e.g. sensor supply / output overloaded or shorted external voltage supply OK output (O1...O4) switched 6

6 Installation 6.1 Installation of the device Install the device on a 35 mm DIN rail. Leave enough space between the unit and the top and bottom of the control cabinet to enable air circulation and to avoid excessive heating. Take into account the internal heating of all devices when mounting several devices side by side and observe the environmental conditions for every device. 6.2 Remove the device 7

6.3 Mounting of the sensors Follow the manufacturer s installation instructions. 7 Electrical connection 7.1 Connection accessories The unit is supplied including the connectors. You can find more information about the available accessories at: www.ifm.com Data sheet search Article number Accessories 7.2 Terminal connection IN AS-i Addr. A+ A- I+ I1...I4 I- 3-wire only AUX E+ E- O1...O4 OUT Load O- (2x) I1 I2 I3 I4 I- I+ O- O- I-: sensor supply 0 V I+: sensor supply +24 V O-: switching output actuator 0 V I1...I4: switching input sensors 1... 4 O1 O2 O3 O4 A+ A- E+ E- O1...O4: switching output actuators 1... 4 A+: AS-i + A-: AS-i - E+: external voltage supply (AUX) for actuators +24 V E-: external voltage supply (AUX) for actuators 0 V 8

WARNING To ensure protection rating IP20 for the housing and the terminals, connect terminals to all the unused connector contacts. WARNING Only for connection with an isolating transformer with a UL approved 10 A upstream fuse at AUX (E+). Alternatively, a class 2 power supply can be used to supply AUX. Please note the technical data concerning the AUX supply. AC3200 Do not connect the I1...I4 und I+, I- connections to external potential. The switch-on and switch-off capacity for triggering solenoids is rated up to 20 W (according to IEC 60947-5-2, utilisation category DC-13). 8 Addressing The address is set to 0 at the factory. 8.1 Addressing with the AC1154 addressing unit When mounted and wired the module can be addressed with the addressing cable (E70213) via the integrated addressing interface. If a slave is used in combination with a master of the new generation (version 2.1), it is possible to select an address between 1A and 31B with the AC1154 addressing unit. If a slave with the ID code "A" (extended address mode possible) is used in combination with a master of the 1st generation (version 1), -- the parameter P3 must be 1 and the output bit D3 must be 0.* The output bit D3 must not be used. -- an address between 1A and 31A must be assigned to this slave. * Default setting 9

9 Technical data SmartLine module Electrical design 10 AC3200 / AC3201 4 digital inputs / 4 digital outputs Operating voltage [V] 18 31.6 DC (AS-i), 20 30 DC (AUX) Total current consumption from AS-i [ma] AC3200: < 250 AC3201: < 30 Current rating per module [A] 4, > 50 C: 2 Inputs PNP (type 2 to IEC 61131-2) Sensor supply AC3200: AS-i AC3201: external to SELV Voltage range inputs [V] 16...30 DC Max. current load for all inputs total Outputs [ma] AC3200: 200 AC3201: 1000 Transistor PNP Switching voltage per output [V] 24 DC (20 30 DC), external to SELV Current rating per output [A] 1 Utilisation category DC-13; utilisation category DC-12: 700 ma. The switch-on and switch-off capacity for the triggering of solenoids is rated up to 20 W (to IEC 60947-5-1). Protection housing / terminals IP 20 / IP 20 Ambient temperature [ C] -25 65 Max. permissible relative [%] 90 (not condensing) humidity Maximum operating altitude [m] 2000 above sea level AS-i profile S-7.A.7 AS-i version 3.0 (extended address mode) Connection To supply AUX, an isolating transistor with a UL approved 10 A upstream fuse at AUX (E+) must be used. Alternatively, AUX can be supplied via a class 2 power supply. Maximum cable length [m] 30 on inputs and outputs Device 4-pole terminal blocks with 5.0 mm pitch

SmartLine module Connectors (all connectors are supplied with the device) AC3200 / AC3201 1x4-pole twin connector with cage clamp connection from Phoenix contact, type TVFKC 1,5/4-ST BK 0.2 1.5 mm² (AWG 24 16) Data sheets are available at www.ifm.com. 3x4-pole connector with cage clamp connection from Phoenix Contact, type 1,5/4-ST BK 0.2..2.5 mm² (AWG 24 14) 9.1 Scale drawing 25,4 59,3 95,4 129,3 35,5 71 9.2 Approvals/standards EC declarations of conformity, approvals etc. are available at www.ifm.com. 11

10 Maintenance, repair, disposal 10.1 Servicing The unit is maintenance-free. 10.2 Cleaning the housing surface Disconnect the device. Clean the device from dirt using a soft, chemically untreated and dry cloth. Micro-fibre cloths without chemical additives are recommended. 10.3 Repair The device must only be repaired by the manufacturer. Observe the safety instructions ( 2.7 Tampering with the device). 10.4 Disposal Dispose of the device in accordance with the national environmental regulations. 12

13