CardaxFT Reader I/O Interface

Similar documents
Controller 3000, dependent on reader technology and site configuration. All I/O functionality is provided on the Controller 3000.

Controller Cardax FT Controller The CardaxFT Controller 5000 is the intelligent field controller in the CardaxFT security system.

Gallagher GBUS Devices

The Cardax FT Controller 6000 can support up to 16 GBUS devices.

4 balanced inputs 1 relay output

Cardax Prox Plus Mifare Reader

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

Cardax FT Series 3 Command Centre

Cardax FT Controller 3000

Quick Start Installation Guide

Cardax FT XtraSec. System Catalogue ELM

TAC I/NETTM 1284, 1280, Security Control Unit

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

IEI emerge MicroNode Install and Setup Guide. Contents

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

VICON ACCESS CONTROL CONTROLLERS

Cardax FT Connectivity Guide

Installation guide for PR302 v2.0 Rev. E

Installation Instructions

Two Door Controller GEN-045

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

MR52 READER INTERFACE

GV-AS Controller. Installation Guide

TruPortal Output Expansion Board Quick Reference

Connecting a Cisco Input Module

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

SINGLE READER EXPANSION MODULE

Digital Keypad Introduction

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

SECTION SWITCHBOARDS

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

COGNEX. Checker SensorView. Quick Reference Guide

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

REX F-0-9 Standalone or Access Controller

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

PR602LCD v1.0 Installer Manual Rev. A

Quick Start Installation Guide

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

Hardware Manual RM CANview Gateway

Connecting a Cisco Output Module

Protégé Elite Suite Touch Screen Keypad (PRT-TLCD)

Secrure door control and I/O expansion. Installation Guide. (ver 1.0)

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Access Control Product Overview

RM35LM33MW liquid level control relay RM35-L V AC/DC

I-RK01 Radio Keypad. Installation Guide. 2 abc. 3 def. 4 ghi. 6 mno. 5 jkl. 8 tuv 9 wxyz. 7 pqrs

Documentation on all Paxton products can be found on our web site -

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

XUX9ARCNT16 photo-electric sensor - XUX - polarised - Sn 11m VAC/DC - terminals

INSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

Installation Instructions (KF-2000)

C5S120 Installation and Connection Guide

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

ACTsmart2 Product Range Operating and Installation Instructions

Installation Instructions

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

RM35LM33MW liquid level control relay RM35-L V AC/DC

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

NCH-1000 (Multiple Breaker Types) Installation Instructions

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

GV-AS200 Controller. Hardware Installation Guide

IntelliStripe 70 HYBRID INSERTION READER TECHNICAL REFERENCE MANUAL. Part Number JUNE 2003

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Installing Sentor. Hardware Installation

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Priva Blue ID Digital input module DI4/DI8/DI16

Key Switch. Document version: 1.5 (Updated 02 May 2017)

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Installation Manual. Contents

3500/53 Electronic Overspeed Detection System

TM3DI16G module TM3-16 inputs spring

Jul 28, Product data sheets

Aged Care Security Solutions. security.gallagher.com

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

ACCESS CONTROL SYSTEM

CA-A480-A Elevator Controller. Reference & Installation Manual

MRC350 Card Capture Reader

XGCS491B201 Standalone panel smart antenna

L-1 Fingerprint Reader Solutions. V-Flex 4G

Programmable controller MCX06C

Transcription:

CardaxFT Reader I/O Interface CardaxFT Reader I/O Interface provides I/O functionality and an interface for connecting Cardax readers to the CardaxFT system.

CardaxFT Reader I/O Interface provides an interface for connecting Cardax door readers, monitoring inputs, and controlling outputs to the CardaxFT system. is designed to provide an interface for up to 8 doors to the CardaxFT system. This device can also be used to monitor inputs and control outputs to meet other requirements. is configured as one of the 16 field devices on the CardaxFT Controller. Each CardaxFT Controller may be configured for a maximum of 8 doors, which matches the capacity of the CardaxFT Reader I/O Interface. If more than one CardaxFT Reader I/O Interface was connected to the CardaxFT Controller, then the total number of doors configured across all CardaxFT Reader I/O Interfaces must still not exceed 8. The remaining field devices on the CardaxFT Controller can include any other Local Bus Units, including CardaxFT Reader I/O Interfaces used for I/O functionality. Integrating Cardax Readers connects to the CardaxFT Controller over an RS485 data cable. Each of the door readers connects to the CardaxFT Reader I/O Interface using 4-core cable. only supports Cardax door readers. These include: Cardax Prox (125, Mifare and TIRIS Series) Cardax Prox Plus (125, Mifare and TIRIS Series) Cardax Prox LR (TIRIS Series) Cardax Swipe (Magstripe) Cardax Swipe Plus (Magstripe) Controlling Inputs and Outputs Making no high level decisions, the CardaxFT Reader I/O Interface monitors the state of the balanced inputs and switches the output relays as instructed by the CardaxFT Controller. Inputs The three balanced inputs per door (24 total) on the CardaxFT Reader I/O Interface are designed to be used as follows: monitoring Door Closed state monitoring Door Locked state Push button exit control The inputs can alternatively be used as normal input connections for other devices. Connectivity Diagram: CardaxFT Reader I/O Interface RS485 Comms from CardaxFT Controller or previous device RS485 Comms to next device CardaxFT Reader I/O Interface Power 13.6V DC ±15% Door 1 Cardax Entry Reader Cardax Comms Door 1 Strike Output Door 1 Position Status Door 1 Lock Status Intruder Alarm Input (or can be used as Door 1 Push Button Exit) Door 1 Cardax Exit Reader This diagram shows connectivity for one door. Up to 16 Cardax readers (entry or exit) can be connected to the CardaxFT Reader I/O Interface for the access control of 8 doors.

Input to sensor connection with tamper Input to sensor connection without tamper 5 V 5 V Input Tamper Switch R1 Input R1 0 V R2 PIR Detector Relay GND R2 Alarm Sensor Relay Output to door strike connection Relay Output to siren connection 12 V 12 V Output Output Common Normally Closed Normally Open Common Normally Closed Normally Open Door Strike Siren Key features of the CardaxFT Reader I/O Interface Power and Comms In Reader A Connection Reader B Connection Balanced Inputs Power Out Relay Output Connectors

The inputs on the CardaxFT Reader I/O Interface are 4-state balanced inputs. The four states monitored are: Open Closed Short Circuit (Tamper) Open Circuit (Tamper) Two 4K7 Ohm resistors must be connected to monitored inputs (as illustrated in the Input to sensor connection diagrams). The two resistors (R1 and R2) allow a tamper switch as well as a sensor output to be wired to each input. The inputs on the CardaxFT Reader I/O Interface are primarily to provide door status monitoring for up to 8 doors and for Request to Exit door control switches. Inputs not required for these functions may be used for: Access controlled doors Passive Infra-Red detectors (PIRs) Uncontrolled doors Equipment alarms Any other devices that provide a clean contact Outputs contains 8 relays, primarily for use as door control relays. Relays not required for this function may be used as: Alarm outputs, e.g. to activate sirens (as illustrated in the Relay Output to siren connection diagram) Logic activated outputs, e.g. to switch on air conditioning Time activated outputs, e.g. to switch on lighting CardaxFT Cabinet The CardaxFT Cabinet is a secure enclosure for the CardaxFT Reader I/O Interface. It provides cost-effective housing and includes many features designed to make installation and servicing easier. The design of the CardaxFT Cabinet enables several Cabinets to be installed side by side, neatly fitting together. Each Cabinet has a lockable door that can be installed, on site, to hinge from any side. When the Printed Circuit Board (PCB) is installed in the CardaxFT Cabinet, optical tamper protection is provided. The front optical tamper detector will sense when the Cabinet door is opened. The rear optical tamper detector will sense if the Cabinet is being removed from the wall. Manufactured from a strong polycarbonate/abs plastic alloy, the CardaxFT Cabinet has a UL94 flame rating of HB. must be mounted in a CardaxFT Cabinet following the directions in the installation instructions to comply with international emission standards such as C-Tick, FCC and CE. CardaxFT Cabinet (with Reader I/O Interface)

April 2002 TECHNICAL SPECIFICATIONS CardaxFT Reader I/O Interface Power Supply Voltage 13.6 V DC ± 15% Current (all relays operated) 300 ma Number of Ports RS485 1 Reader ports for Cardax readers 16 Communications To CardaxFT Controller RS485 at 187.5 Kbits per second To Cardax readers Cardax proprietary Cable Specifications Communications to: CardaxFT Controller Cardax readers Power Two wire Cat 5 (or better) Data Cable 4-core cable Dependent upon distance from power supply Max Cable Lengths From CardaxFT Controller 500 m To Cardax readers 200 m Inputs/Outputs Inputs (4-state balanced) 24 Relay Outputs 8 Electrical Outputs Specifications Supported ID Technologies Housing Relays are capable of switching the following loads: 3 Amps at 24 V DC/AC resistive load 1 Amp at 24V DC/AC inductive load Cardax Magnetic Stripe Cardax Proximity Cardax Smart Card CardaxFT Cabinet Height Width Depth 280 mm 280 mm 94 mm Weight (nominal) PCB and Cabinet 1862 grams Environmental Data Temperature range -10 to +55 C Fire Resistance Flame rating of Cabinet UL94 HB Compliance Standards complies with C-Tick, CE, and FCC approvals. Compliance with other international standards will be proven during 2002/2003. Please contact Cardax for the latest list of approvals. All CardaxFT PCBs must be mounted in CardaxFT Cabinets following the directions in the installation instructions to comply with international standards.

Whilst every effort has been made to ensure accuracy, neither Cardax (International) Limited nor any employee of the company, shall be liable on any ground whatsoever to any party in respect of decisions or actions they may make as a result of using this information. In accordance with the Cardax policy of continuing development, design and specifications are subject to change without notice. Developed and manufactured by Cardax (International) Limited, an ISO 9001 certificated supplier. Cardax is a registered trademark of Cardax (International) Limited. Cardax (International) Limited is a subsidiary of Gallagher Group Limited. Patents pending. http://www.cardax.com Copyright Cardax (International) Limited 2002. All rights reserved. Cardax (International) Limited Kahikatea Drive Private Bag 3026 Hamilton New Zealand Phone +64-7-838 9851 Fax +64-7-838 9801 Email cdxsales@cardax.com Cardax Offices are located in: Australia China New Zealand South Africa United Kingdom United States of America 6J0666 04/02