VIDEO DOOR ENTRY FEBRUARY Quick Install Guide. tel: +44 (0) fax: +44 (0) web:

Similar documents
VDP RANGE. Quick Installation Guide. tel: +44 (0) fax: +44 (0) web:

ITC237-PU1A-IRHL. Quick Install Guide FEBRUARY tel: +44 (0) fax: +44 (0) web:

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

Best Practice. Cyber Security. tel: +44 (0) fax: +44 (0) web:

Fast operation of IP Villa System V 1.0

SVT-WIFI Video Intercom System C

2-Wire Residential Intercom

Residential IP Intercom Kit

1. NVR Connection Diagram Wizard Setup Access System Using Mobile Device Access System Using PC Client Software 5

Networking Fundamentals. An Introduction to Networks. tel: +44 (0) fax: +44 (0) web:

Agenda. August 23, 2017 Slide 2

Setting Up The HikVision Villa IP Intercom for The First Time

IP Apartment System Quick Start Guide

2-Wire ECL-VIP200 User s Manual

Setting Up Lift Control For The First Time

Digital Villa VTO (VTO2 series) User s Manual

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

DAHUA TRAINING. Course Notes. tel: +44 (0) fax: +44 (0) web:

Villa VTO (Version 3.1)

Unit Door Station User's Manual ----VTO12XX Series

INTELLIGENT BUILDING PRODUCTS VIDEO INTERCOM / ACCESS CONTROL / SMART LOCK Quarter

OnView Mobile Monitoring

VTO2000A Series User s Manual

Quick User Guide for DVR Camera System

App VTSS Mobile V2.0

EC-11 Ethernet Converter

RY-IP44. Input/Output Network Adaptor. Programming Manual. For use with IX Series, IS-IP Series, and IPW-1A

RY-IP44. Input/Output Network Adaptor. Programming Manual. For use with IX Series, IS-IP Series, and IPW-1A

INTELLIGENT BUILDING PRODUCTS VIDEO INTERCOM / ACCESS CONTROL / SMART LOCK Quarter

UP TO 25% OFF SELECTED DAHUA PRODUCTS

User manual. tel.+ (48)

Setting Up The Hikvision IP Intercom For The First Time

DIY Security Cameras. Hikvision. Intercom Setup Guide. February 2018

DAHUA IP INTERCOM TRADE ONLY

Setting Up IP Intercom For The First Time With WiFi Room Stations Only

Digital VTH (Version 3.1)

VTO2 Series User s Manual

Modular VTO (Version 3.1)

Digital VTH (Version 4.0)

Villa Series Door Station Module User Manual

Module VTO User s Manual

Version B Wi-Fi IP CAMERA

HD IP CAMERA USER GUIDE

APWIFIDS WI-FI DOOR STATION

IP Camera Quick Start Guide ==================== H Series V3.1

GV-Access for ios and Android Mobile Devices

Unit Door Station User's Manual ----VTO12XX Series

NETWORK SETUP. 1. From the IP-Modules Home page Click Login

WiFi Video Doorbell. User Manual

ST-HD-CVR4CH ST-HD-CVR8CH ST-HD-CVR16CH. Professional Digital Video Recorders QUICK START GUIDE

CHI Easy Access: Register From on the CHI Network

U9 Talk DDNS Server Instruction. -- Cloud Intercom

Standalone Access Control

VTO12XX Series User's Manual

Northern NVRPOE & TVIDVR Series How to Setup Guarding Vision (v3.0)

Technical Support Bulletin Setting up third-party SIP apps with the Communication agent in OS 2.7

User Instructions. For WiFi (PRO 2) Manual Version 1. For warranty, service and support, contact:

Villa VTO (Version 3.1)

RoboKind Tablet Apps

Welcome Contents Diagram

WiFi Wireless Video Door Phone. User Manual

Avantis AXI WEB SERVER MODULE USER MANUAL

VTO1210C_X User's Manual

JZTEK DVR Operation Manual

LonHand series product specification

Integration tool user manual

HD IP CAMERA USER GUIDE

CLOUD SERVICE / APP(COMViewerGLOBAL)

ZAVIO Indoor Box Camera. Quick Installation Guide

GV-AS200 Controller. Hardware Installation Guide

My Digital Basecamp. Learning App for BASF employees. Quick Guide for Android and ios

Digital Recorder End User Guide. Official UK distribution partner

RY-IP44. Input/Output Network Adaptor. Programming Manual. For use with IX Series, IS-IP Series, and IPW-1A

SIP IP VIDEO DOOR PHONE.

PrinterOn iphone and ipad app

NC COM GND Warning sensor. voice box. socket

JZTEK DVR Operation Manual

ShareLink 200 N Setup Guide

VTO3211D-P User s Manual

3G/4G OUTDOOR ROUTER Instruction Manual

Digital VTS1500A (2.0) User s Manual

Unit VTO (Version 3.1)

Signup for Multi-Factor Authentication

Amcrest 650 TVL DVR Quick Start Guide

This Job Aid will assist setting up the Outlook Application for use on iphones and Android phones.

JZTEK DVR Operation Manual

power port make sure the ac adapter is plugged into the correct port Make sure to include at the beginning.

Enrolling Devices in Duo

Yale Smart WIFI CCTV FAQs

HD Pan Tilt IP Camera

Set Password. After you complete the setup, click OK button, system pops up the following interface for you to confirm. Click OK button to exit

VITEK VTD-TND4RMS FEATURES

MFA Pilot Instructions

pending Checking your just got easier. AGENT NET INFO MOBILE PENDING Android BlackBerry iphone View View View

Amcrest Eco HDCVI DVR Quick Start Guide

ClassHub for Teachers. A User Guide for the Classroom

BROADBAND 3G/4G MODEM Instruction Manual

IPCAMHD61 User Manual

Amcrest 960H DVR Quick Start Guide

USER'S MANUAL ZOOM SERIES WIFI SMART APP

Transcription:

FEBRUARY 2017 Quick Install Guide VIDEO DOOR ENTRY Official UK distribution partner tel: +44 (0)1457 874 999 fax: +44 (0)1457 829 201 email: sales@cop-eu.com web: www.cop-eu.com

Home System Configuration When configuring a home VDP system, all devices should first be connected together. Usually, this is done by connecting both the camera unit (VTO) and monitor unit (VTH) to the VTNS1060A PoE switch. The VTNS1060A is a 24v passive PoE unit, this is a different type of PoE than that seen on conventional IP devices. As such, both the VTO2000A and VTH1550CH can only be used with 24v passive PoE or by connecting a 12/24vdc power supply to the power input terminals on the units. VTO2000A VTNS1060A VTH1550CH 24v PoE 24v PoE VTO Connections Tamper Switch NET +12V/+24V GND 485_A 485_B GND +12V_OUT UNLOCK BUTTON FEEBBACK GND NO NC COM Inputs & Outputs Network Connection Tamper Switch Network Connection +12/24v GND 12v Out Unlock Button Feedback NO/NC/COM Sounds an alarm in the event that the VTO unit is tampered with Connect the supplied RJ45 adapter cable to this port Used when not powering the VTO via PoE, connect the 12v or 24v DC positive supply to this terminal Ground connection for 12v or 24v DC negative supply and other inputs DC 12v continuous output for auxillary device Input to connect a switch such as a push button for releasing the door lock Input for door contact to check if the door is closed before engaging lock Relay output used when unlocking door 2

VTO Camera Configuration With a PC or Laptop connected to the network switch, run the Dahua config tool to find the VTO unit. By default the VTO has an IP address of 192.168.1.110, this can be changed if required via the config tool or within the VTO web browser. Login to the VTO via the computers web browser. Username: admin Password: admin Select the Local Config tab and change Device Type to Villa Station. Click OK to save the setting. Select the Logout option on the left menu and click Reboot Device, this will restart the VTO. VTH Monitor Configuration To configure the VTH unit use the built in menu within the monitor itself. VTH units do not support web browser configuration. Select Settings > Project Settings and input the engineer password: 002236 (default) For DHI-VTH5221D units hold down the Settings button for 5 seconds and enter the engineer password: 888888 (default) The Product Info menu is used to set the room number of the VTH and to configure the unit as a Master or Extension unit. If only a single VTH is being used in the system, then this should be set to Master and a room number chosen. Adding multiple VTH units is covered on page 5. Tel: +44 (0)1457 874 999 Fax: +44 (0)1457 829 201 Email: sales@cop-eu.com Online: www.cop-eu.com 3

VTH Configuration (Continued) In the project settings menu select NetSet to configure the VTH network settings. When configuring the network address of the VTH it is vital to ensure the IP address range is within the same Subnet as the VTO. For both the VTO and VTH to communicate, each unit must have the IP address details of the other unit. To add the VTO unit to the VTH, select Network and input the VTO units IP address and set Enable Status to ON. To add the VTH to the VTO, revisit the VTO web browser and go to System Config > Indoor Manager > Add. Input a family name, first name and Nickname, these are purely for reference. Enter the VTH Short number. This number must match the Room Number set in the VTH Product Info page. Click OK to confirm the setting. At the top of the VTH screen the icon should disapear, this indicates that the VTO and VTH are now connected. To call the VTH from the VTO, press the button on the VTO unit and press Answer to initiate two way communication. 4

Adding Additional VTH Units When additional VTH units are to be added to the system, usually it is required that all VTH units are called by the VTO. To enable this feature and configure the additional VTH units; Login to the VTO web browser and go to System Config > LAN Config and tick the Group Call option. Click OK then select Logout > Reboot On the additional VTH unit, first configure the network address within the same range as both the VTO and existing VTH units. Go to Project Settings > Product Info and select Master, this will change the VTH to Extension mode. Input the room number of the master unit followed by -1, as an example if the room number is 1 enter 1-1 or 1-2, 1-3 etc for further additional units. In the Master IP field enter the IP address of the main VTH unit. Select OK to save the setting, the configuration is now complete. Tel: +44 (0)1457 874 999 Fax: +44 (0)1457 829 201 Email: sales@cop-eu.com Online: www.cop-eu.com 5

Application Set Up When configured as a home system, both the VTO2000A & VTO2221D-WP support P2P connections. Currently P2P is only supported for ios and Android devices. Download the mobile application to your mobile device by scanning the QR codes below or by searching for the app in your relative app store. iphone ipad Android Phone Android Tablet idmss - Free idmss HD- Free gdmss - Free gdmss HD - Free Connect using the app 1. Open DMSS app 2. Select Door 3. Tap the Device List icon 4. Tap +Add Device 5. Input a name (for your reference only) Press QR button 6. Scan the QR Code from the P2P page in the VTO web browser. 7. Select Push Notifications to enable video calls. 8. Tap Start Live Preview 9. View cameras 6

Modular System Configuration When installing a VDP system in an apartment/business setting, several modules are available. Each module has an IN and OUT connection, this links the various modules together. Regardless of which modules are to be used, the camera unit is always the master and is the first device in the chain. VTNS1060A VTO2000A-C Apartment 1 24v PoE 24v PoE Link Wire Apartment 2 VTO2000A-B 24v PoE Link Wire Apartment 3 VTO2000A-K 24v PoE VTO Module Configuration With a PC or Laptop connected to the network switch, run the Dahua config tool to find the VTO unit. By default the VTO has an IP address of 192.168.1.110, this can be changed if required via the config tool or within the VTO web browser. Login to the VTO via the computers web browser. Username: admin Password: admin Select the Local Config tab and change Device Type to Modularize Villa click Ok to save the setting. Select the Logout option on the left menu and click Reboot Device, this will restart the VTO. Tel: +44 (0)1457 874 999 Fax: +44 (0)1457 829 201 Email: sales@cop-eu.com Online: www.cop-eu.com 7

Module Configuration To configure the layout of the modular system, go to System Config > Local Config > Fascade Layout Click the Plus symbol in the location of the next module, then select the module type. Multiple modules can be aded to the layout. Click Save to confirm the settings, then select the Logout option on the left menu and click Reboot Device, this will restart the VTO. 8

VTH Monitor Configuration To configure the VTH unit use the built in menu within the monitor itself, VTH units do not support web browser configuration. Select Settings and input the engineer password: 002236 (default) The Product Info menu is used to set the room number of the VTH and to configure the unit as a Master or Extension unit. When configuring a modular system, each monitor will be configured as a Master. In the Room No field input the room number, such as 1 for apartment 1. Select Settings and then Project Settings, in the project settings menu select NetSet to configure the VTH network settings. When configuring the network address of the VTH it is vital to ensure the IP address range is within the same Subnet as the VTO. For both the VTO and VTH to communicate, each unit must have the IP address details of the other unit. To add the VTO unit to the VTH, select Network and input the VTO units IP address and set Enable Status to ON. Tel: +44 (0)1457 874 999 Fax: +44 (0)1457 829 201 Email: sales@cop-eu.com Online: www.cop-eu.com 9

VTH Monitor Configuration For both the VTO and VTH to communicate, each unit must have the IP address details of the other unit. To add the VTO unit to the VTH, select Network and input the VTO units IP address and set Enable Status to ON. To add the VTH to the VTO, revisit the VTO web browser and go to System Config > Indoor Manager > Add. Input a family name, first name and Nickname, these are purely for reference. Enter the VTH Short number This number must match the Room Number set in the VTH Product Info page. For details on self password see page 11. Click OK to confirm the setting. Repeat the process for additional monitors, each time setting the monitor to a unique IP address and Room Number. To program the module buttons, go to System Config > Local Config > Facade Layout. On the module images, click the relative buttons to assign a specific apartment number to it. 10

Keypad Configuration When using the keypad module, first add it to the layout as described on page 8. The keypad module has two primary functions, calling and password entry. To make a call to a specific room, simply enter the room number followed by the phone button. To configure password entry; There are two types of password that can be used, Self Password or Uniform Password. Configure which type of password is to be used in System Config > Local Config > Password Unlock Type Self password is an individual password given to each user, this is created when adding the VTH monitor in the Indoor Manager menu, as described on page 4. Uniform Password is a global password used for all users, rather than a password being issued on an individual basis. The uniform password is configured in System Config > Local Config > New Unlock Password. Once the password type has been selected and a Uniform Password set (if required), click OK to save the configuration. The format when entering the password on the keypad is # > Password > # as an example, a password of 888888 would be entered as #888888#. Tel: +44 (0)1457 874 999 Fax: +44 (0)1457 829 201 Email: sales@cop-eu.com Online: www.cop-eu.com 11

Cop Security Delph New Road, Dobcross, Oldham OL3 5BG