G.M. International S.r.l. Via Mameli, Villasanta (MB) - ITALY

Similar documents
INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

SIL 2/3 Relays for all applications, with or without Line & Load Diagnostics. Product presentation

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Intrinsically Safe Barriers

SHORT FORM INTRINSICALLY SAFE, SIL CERTIFIED INSTRUMENTATION FOR HAZARDOUS AREAS

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

INSTRUCTION MANUAL. SIL 2 Switch / Proximity Detector Repeater, Open Collector Output DIN-Rail and Termination Board, Model D5231E

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Inductive sensor NI3-EG08K-Y1-H1341

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

LB Remote I/O. CEAG Sicherheitstechnik GmbH 256

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

5 Fieldbus Technology

APPLICATION GUIDE. Interface Modules IM Series.

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

PHOENIX CONTACT - 01/2008

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

PHOENIX CONTACT - 12/2007

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-24VDC

I/A Series HARDWARE Product Specifications

Backplane. System integration. Backplane

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

Backplane. Allen-Bradley. System integration. Backplane

G.M.International Termination Boards

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

Inductive sensor BI5-EM18-Y1X-H1141

Level gauges Series LS Level indicator, switch and transmitter for liquids

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

APS SCALE SERIES DIMENSIONS

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Series 3730 Type Electropneumatic Positioner

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

FieldLink process networking

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

S900 Remote I/O System Intrinsic safety in the field ABB

S800 I/O ABB Automation

Backplane. System integration. Backplane

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

General. Remote I/O A4/1.

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

Signal Conditioning Modules and Terminal Boards

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

Inductive sensor with analog output BI15-M30-LI-EXI

Series 3730 Electropneumatic Positioner Type

INSTALLATION INSTRUCTIONS

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

List of Components Versions for Safetec SFT-9000 systems

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

PSS SIL3 Power Supply System PSS1250, 24Vdc, A, Zone 2/Div Rack for up to 6 modules PSM1250

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Float Switches with Permanent Magnet For Vertical Installation Model RSM

SWC1090 configuration software for G.M. International Isolators series D1000 and E1000. Installation and use manual

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

MULTICHANNEL DATA RECORDERS

Digital electropneumatic Positioner SideControl

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

-Camille Bauer Div. of Absolute Process Instruments, Inc. Phone: Fax: J-1

Discrete I/O connected direct onto. Input and Output Function Blocks. Two built-in Solid State Relay Outputs. Discrete Function Blocks in the field

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

M-series Intrinsically Safe I/O

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions

Trident and Trident X2 Digital Process and Temperature Panel Meter

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Signal conditioners with Functional Safety The MACX ranges

Technical Data. General specifications. Rated operating distance s n 3 mm

Relays SAFETY RELAYS SERIES. High Integrity Safety Relays. Suitable for SIL 3 applications according to IEC and IEC D5000 / D1000 SERIES

IHP24. Intelligent Hydraulic Positioner D HP- PL

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

Transcription:

Notes NET = Net Pricing, NOT discountable SV = Special Version; Non Stock Delivery NA = Not Yet Available NC = Free of Charge D = Din Rail Mounting DB = Power Bus Mounting BR = Board Mounting R = Rack Mounting PA = Panel Mounting FL = Flush Mounting PO = Pole Mounting LP = Loop Power FF = Fully Fitted Enclosure: Including Bottom Plate, DIN Rail, Earthing Bar, FF = Fully Fitted Enclosure: Including Bottom Plate, DIN Rail, Earthing Bar, Wall Mounting Brackets, Double Terminals Blocks for Redundand Line Shield connections, DIN Rail Stoppers in Number and Type Specified. Sizes in mm SIL Rating according to IEC6508/65 G.M. International S.r.l. Via Mameli, 53-55 - 20852 Villasanta (MB) - ITALY Tel. : +39 039 2325 038 Fax : +39 039 2325 07 e-mail : info@gmintsrl.com Web Site : www.gmintsrl.com Price List 206 ( Rev. dated March st, 206 )

G.M. International srl Via San Fiorano, 70-20852 Villasanta (MB) - Italy Tel. : +39 039 2325038 - Fax : +39 039 232507 - E-Mail : info@gmintsrl.com - Web : www.gmintsrl.com Price List 206 ( Rev. dated March st, 206 ) Page # 2 ANALOGUE INPUT I.S. MODULES D00S Ch; Smart-Hart; Active-Passive Input; Sink-Source Output; SIL D00D 2 Ch; Smart-Hart; Active-Passive Inputs; Sink-Source Outputs; Duplicator; SIL 2 D00S-026 Ch; 4-20 ma Input; 0-20 ma / 0-0 V Output D00D-026 2 Ch; 4-20 ma Inputs; 0-20 ma / 0-0 V Outputs; Duplicator 2 D00S-046 Ch; Smart-Hart; Active-Passive Input; Sink-Source Output; Low I.S. Parameters; SIL D00D-046 2 Ch; Smart-Hart; Active-Passive Inputs; Sink-Source Outputs; Duplicator; Low I.S. Parameters; SIL 2 D00S-047 Ch; 4-20 ma Input; 0-20 ma / 0-5 V Output D00D-047 2 Ch; 4-20 ma Inputs; 0-20 ma / 0-5 V Outputs; Duplicator 2 D00S-054 Ch; -5 to +55 mv Input; 4-20 ma Output D00S-056 Ch; -5 to +35 mv Input; 4-20 ma Output D00S-057 Ch; -5 to +0 mv Input; 4-20 ma Output D02Q 4 Ch; 4-20 ma Passive non Isolated Inputs; 4-20 ma Source Outputs ; Factory Programmable Splitter 4 D04S Ch; Hart; 4-20 ma Passive Input; 4-20 ma Sink-Source Output; SIL D04S-060 Ch; Hart; 4-20 ma Passive Input; 4-20 ma Source Output up to KΩ Load; D04S-083 Ch; Hart; 4-20 ma Passive Input; 2-0 Volt Output; D04D-083 2 Independent Ch; Hart; 4-20 ma Passive Inputs; 2-0 Volt Outputs; 2 D04D 2 Independent Ch; Hart; 4-20 ma Passive Inputs; 4-20 ma Sink-Source Outputs; SIL 2 D50S Ch; 4-20 ma 2-Wire IN; 4-20mA Source OUT; Hart; SIL 2 D50D 2 Ch; 4-20 ma 2-Wire IN; 4-20mA Source OUT; Hart; SIL D504S Ch; 4-20 ma, 2/3-Wire IN; ma/v Sink/Source OUT; Hart; SIL 2 D504D 2 Independent Ch; 4-20 ma, 2/3-Wire IN; ma/v Sink/Source OUT; Hart; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs D505S Ch; 4-20 ma, 2/3-Wire IN; 4-20mA Source OUT; Hart; S/K/V Versions Available; SIL 2 D505D 2 Ch; 4-20 ma, 2/3-Wire IN; 4-20mA Source OUT; Hart; S/K/V Versions Available; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs D522Q 4 Ch; 4-20 ma IN/OUT; Configurable as Duplicator, Triplicator or Quadruplicator 4 ANALOGUE OUTPUT I.S. MODULES D020S Ch; Smart-Hart; Isolating Driver for I/P; 0/4-20 ma IN-OUT; SIL D020D 2 Independent Ch; Smart-Hart; Isolating Driver for I/P; 0/4-20 ma IN-OUT; SIL 2 D020S-027 Ch; Isolating Driver for I/P; Input 2-0 V; Output 4-20 ma D020D-027 2 Ch; Isolating Driver for I/P; Input 2-0 V; Output 4-20 ma 2 D020S-050 Ch; Isolating Driver for I/P; Input 0-0 V; Output 4-20 ma D020D-050 2 Ch; Isolating Driver for I/P; Input 0-0 V; Output 4-20 ma 2 D020S-067 Ch; Isolating Driver for I/P; Input - 5 V; Output 4-20 ma D020D-067 2 Ch; Isolating Driver for I/P; Input - 5 V; Output 4-20 ma 2 D0S Ch; Gas-Fire Detector Interface; Loop Powered -40 ma IN/OUT D0D 2 Ch; Gas-Fire Detector Interface; Loop Powered -40 ma IN/OUT 2 D5020S Ch; 4-20 ma, I/P Driver; Transparent Open-Short Circuit Alarm Function; Hart SIL 2 D5020D 2 Independent Ch; 4-20 ma, I/P Driver; Transparent Open-Short Circuit Alarm Function; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs

Price List 206 ( Rev. dated March st, 206 ) Page # 3 DIGITALI INPUT I.S. MODULES D030S Ch; + Relay Output SPDT (Duplication or LFD Alarm); Line Monitoring Function; SIL D030D 2 Ch; 2 Relay Outputs SPDT; Line Monitoring Function; SIL 2 D30S Ch; + Relay Output SPDT (Duplication or LFD Alarm); Line Monitoring Function; AC Power; SIL D30D 2 Ch; 2 Relay Outputs SPDT ; Line Monitoring Function; AC Power; SIL 2 D030S-08 Ch; + Relay Output SPDT (Duplication or LFD Alarm); Line Monitoring Function; 2VDC Power D030D-08 2 Ch; 2 Relay Outputs SPDT; Line Monitoring Function; 2 VDC Power Supply 2 D03D 2 Ch; 2+2 OC Transistor Outputs (Duplication or LFD Alarm); Line Monitoring Function; KHz Max; SIL 2 D03Q 4 Ch; 4 OC Transistor Outputs; Line Monitoring Function; KHz Max; SIL 4 D032D 2 Isolated Ch; 2+2 Relay Outputs SPST (Duplication or LFD Alarm); Line Monitoring Function; SIL 2 D032Q 4 Isolated Ch; 4 Relay Outputs SPST, Line Monitoring Function; SIL 4 D033D 2 Isolated Ch; 2+2 OC Transistor Outputs (Duplication or LFD Alarm); Line Monitoring Function; SIL 2 D033Q 4 Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function; SIL 4 D033D-052 2 Iso. Ch; 2+2 OC Trans. Out (Dupl. or LFD Alarm); Line Mon. Func; Common Negative; 2 D033Q-052 4 Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function; Common Negative; 4 D033D-058 2 Iso. Ch; 2+2 OC Trans. Out (Dupl. or LFD Alarm); Line Mon. Func; Common Positive; 2 D033Q-058 4 Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function; Common Positive; 4 D034S Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL D034D 2 Independent Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 2 D5030S Ch; SPDT Relay Output; Line Monitoring Function; SIL 2 D5030D 2 Independent Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL Note: Unit is field configurable as Duplicator: IN / 2 OUTs or IN - + OUT (DI + LFD) D503S Ch; NO/NC Solid State Output; Line Monitoring Function; SIL 2 D503D 2 Independent Ch; 2 NO/NC Solid State Out; Line Monitoring Function; SIL Note: Unit is field configurable as Duplicator: IN / 2 OUTs or IN - + OUT (DI + LFD) D523E 8 Ch; NO/NC Solid State Output; Line Monitoring Function; Fully Programmable; SIL 8 Note: Unit is field fully configurable as Duplicator; Triplicator; etc. : up to IN / 8 OUTs or any combinations. D5032S Ch; SPST Relay Output; Line Monitoring Function; SIL 2 D5032D 2 Independent Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL Note: Unit is field configurable as Duplicator: IN / 2 OUTs or IN - + OUT (DI + LFD) D5034S Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 2 D5034D 2 Independend Ch; Trasparent to Contact-Prox & Line Monitoring Function; SIL D5036S Ch; SPDT Relay Output; Line Monitoring Function; SIL; No G3 Coating. 2 D5036D 2 Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL; No G3 Coating. D5037S Ch; NO/NC Solid State Output; Line Monitoring Function; SIL; No G3 Coating. 2 D5037D 2 Ch; 2 NO/NC Solid State Outputs; Line Monitoring Function; SIL; No G3 Coating. DIGITALI INPUT NON I.S. MODULES D5093S Ch; AC (24 to 0 Vac/Vdc) Digital Input Module; SIL 2 D5093D 2 Ch; AC (24 to 0 Vac/Vd) Digital Input Module; SIL

Price List 206 ( Rev. dated March st, 206 ) Page # 4 DIGITAL OUTPUT I.S. MODULES 4 Separated Channels; + + + 72 ma Imax; 334 Ω; SIL 4 D040Q 2 + 2 Channels in parallel; 2 + 2 44 ma Imax; 67 Ω; SIL 2 3 Channels in parallel; 26 ma Imax; Ω; SIL 4 Channels in parallel; 288 ma Imax; 84 Ω; SIL D04Q 4 Channels to drive LEDs; + + + 49,6 ma Imax; 484 Ω; SIL 4 4 Separated Channels, + + + 88,2 ma Imax; 273 Ω; SIL 4 D042Q 2 + 2 Channels in parallel, 2 + 2 76,4 ma Imax; 37 Ω; SIL 2 3 Channels in parallel, 264,6 ma Imax; 9 Ω; SIL 4 Channels in parallel, 352,8 ma Imax; 68 Ω; SIL 4 Separated Channels, + + + 49,6 ma Imax; 484 Ω; SIL 4 D043Q 2 + 2 Channels in parallel, 2 + 2 99,2 ma Imax; 242 Ω; SIL 2 3 Channels in parallel, 48,8 ma Imax; 6 Ω; SIL 4 Channels in parallel, 98,4 ma Imax; 2 Ω; SIL D045Y 2 Channels for ATOS Valve 249/307 ma Imax; 8/68 Ω (Alternating Channels) D046Y 2 Channels for WANDFLUH Valve 366 Imax; 68 Ω (Alternating Channels) 2 D048S Ch; NE Loads; Loop Powered; Line & Valve Monitoring Function; Selectable Output; SIL D049S Ch; NE Loads; Bus Powered; Line & Valve Monitoring Function; Selectable Output; SIL D5048S D5049S Ch; Solenoid Driver; Loop Powered; Transparent Line & Load Alarm Function; SIL Note: Unit has three field selectable Valve power Outputs; Both Open and Short Circuit Fault Detection Ch; Solenoid Driver; Bus Powered; Line & Load Alarm Function; SIL Note: Unit has three field selectable Valve power Outputs; Both Open and Short Circuit Fault Detection 2 2 D5040S Ch; Solenoid Driver; Loop Powered; SIL Note: Unit has two field selectable Valve power Outputs; D5040D 2 Ch; Solenoid Driver; Loop Powered; SIL Note: Unit has two field selectable Valve power Outputs; D5240T 3 Ch; Solenoid Driver; Bus Powered; SIL 3 Note: Unit has three field selectable Valve power Outputs; DIGITAL OUTPUT / RELAY OUTPUT I.S. MODULES D044S Channel; SPDT Relay Output to Hazardous Location D044D 2 Channel; 2 SPDT Relay Outputs to Hazardous Location; SIL 2 D5244S Channel; SPDT Relay Output to Hazardous Location; SIL D5244D 2 Channel; 2 SPDT Relay Outputs to Hazardous Location; SIL 2

Price List 206 ( Rev. dated March st, 206 ) Page # 5 SIGNAL CONDITIONERS & TRIP AMPLIFIERS I.S. MODULES D052S Ch; ma, V - Input, Output; Fully Software Programmable; D052D 2 Ch; ma, V - Input, Output; Fully Software Programmable; 2 D052X Input-2 Outputs Ch; Duplicator; ma, V - Input, Output; Fully Software Programmable D052Y 2 Ch; ma, V - Input, Output; High-Low Selector / Adder / Subtractor; Fully Software Programmable 2 D053S Ch; ma, V - Input, Output + 2 Trip Amplifiers; Fully Software Programmable; SIL D053S-02 Ch; ma, V - Input, Output + 2 Trip Amplifiers; Fully Software Programmable; 2 Vdc Power Supply; D054S Ch; Smart-Hart; 0/4-20 ma Input; ma-v Output + 2 Trip Amp; Fully Software Programmable; SIL D5254S Ch; Smart-Hart; 0/4-20 ma Input; ma-v Output + 2 Trip Amp; Fully Software Programmable; SIL 2 TEMPERATURE INPUT I.S. MODULES D072S Ch; TC-RTD-Tx Pot Input; ma-v Output; Fully Software Programmable; SIL D072D 2 Ch; TC-RTD-Tx Pot Input; ma-v Outputs; Fully Software Programmable; SIL 2 D072S-024 Ch; 0-80 or 6-80 mv Input / Output; D072D-024 2 Ch; 0-80 or 6-80 mv Input / Output; 2 D072D-028 2 Ch; Input & Output According to APN0008 2 D073S Ch; TC-RTD-Tx Pot IN; ma-v Output + 2 Trip Amplifiers; Fully Software Programmable; SIL D073S-0 Ch. TC-RTD-Tx Pot IN; ma-v Output + 2 Trip Amp; Fully Software Programmable; 2Vdc Power Supply D5072S Ch; TC-RTD-Tx Pot Input; ma plus Burnout Alarm Outputs; Fully Programmable, SIL 2 D5072S-087 Ch; RTD Input; RTD Output; 2 D5072D 2 Ch; TC-RTD-Tx Pot Input; ma Outputs; Fully Programmable, SIL Note: Unit is field configurable as Duplicator IN - 2 OUT D5273S Ch; TC-RTD-Tx Pot Input; ma Outputs; + 2 Trip Amplifiers; Fully Programmable, SIL TEMPERATURE INPUT NON I.S. MODULES D072D-059 2 Ch; TC-RTD-Tx Pot Input; ma-v Outputs; Fully Software Programmable; 2 FREQUENCY INPUT I.S. MODULES D035S Ch; Contact-Prox-LL-Magnetic Pick-up Input; 0-50 KHz Range; Pulse (Open Collector) Output D060S Ch; Cont-Prox-LL-Magnetic Pick-up Input; 0-50 KHz Range; Pulse + ma-v + Trip Ampl. Outputs; Note: Fully Software Programmable D060S-049 Ch; Cont-Prox-LL-Magnetic Pick-up Input; 0-50 KHz Range; Pulse + ma-v + Trip Ampl. Outputs; Note: Special Version with Clamping Diode; Fully Software Programmable D5060S Ch; 0-50 KHz Frequency Input; Analog Output plus Pulse Repeat or Alarm Output 2 D06S D06S-077 D062S D5062S SERIAL LINE I.S. MODULES FieldBus / ModBus Isolated Interface; Communication speed up to,5 M bit/sec; Note: Hazardous Areas: RS485, RS4; Safe Areas: RS485, RS4, RS232 FieldBus / ModBus Isolated Interface; Communication speed up to,5 M bit/sec; Note: Hazardous Areas: RS485, RS4; Safe Areas: RS485, RS4, RS232; Lower Safety Parameters VIBRATION INPUT I.S. MODULES Vibration Monitor Sensors Isolated Interface; Note: Input from Bentley Nevada, BK & Vibrometer Sensors Vibration Monitor Sensors Isolated Interface; SIL Note: Input from Bentley Nevada, BK & Vibrometer Sensors 2

Price List 206 ( Rev. dated March st, 206 ) Page # 6 D063S D064S to 4 parallel 350 Ohm Load Cell Input; 5V, 80 ma total capability; 6-Wire IN-OUT; Note: Fully Transparent; 30.000 Division Accuracy to 4 parallel 350 Ohm Load Cell Input; 5V, 80 ma total capability; 6-Wire Input; 4-20 ma & Modbus Output; Note: 30.000 Division Accuracy; Automatic Bridge Calibration System D5263S to 4 parallel 350 Ohm Load Cell Input; 5V, 80 ma total capability; 6-Wire IN-OUT; SIL Note: Fully Transparent; 30.000 Division Accuracy D5264S to 4 parallel 350 Ohm Load Cell Input; 5V, 80 ma total capability; 6-Wire Input; 4-20mA & Modbus Out; SIL Note: 30.000 Division Accuracy; Automatic Bridge Calibration System LOAD CELL INPUT I.S. MODULES ANALOG INPUT NON I.S. MODULES D00D-002 2 Ch; 0-5 Vdc Input; 4-20 ma Output; Fix Range 2 D00S-00 Ch; -30 + 30 Vdc Input; 4-20 ma Output; Fix Range D00S-05 Ch; 0-50 Vdc Input; 4-20 ma Output; Fix Range D00S-06 Ch; 0-20 mvdc Input; 4-20 ma Output; Fix Range D00S-07 Ch; -0 + 0 Vdc Input; 4-20 ma Output; Fix Range D00S-023 Ch; -5 + 5 Vdc Input; 4-20 ma Output; Fix Range D00D-029 2 Ch; -20 + 20 ma Input; 0-20 ma Output; Fix Range 2 D00D-030 2 Ch; 0-0 Vdc Input; 4-20 ma Output; Fix Range 2 D00D-035 2 Ch; 0-5 Vdc Input; 4-20 ma Output; Fix Range 2 D00S-038 Ch; -50 + 50 Vdc Input; 4-20 ma Output; Fix Range D00S-055 Ch; 0-70 Vdc Input; 4-20 ma Output; Fix Range D00D-06 2 Ch; 0-40 Vdc Input; 4-20 ma Output; Fix Range 2 FLAMMABLE LIQUID DETECTOR INPUT I.S. MODULES D080D 2 Ch; Relay Output SPDT; Suitable for 3 Wire probes 2 D08D 2 Ch; O.C. Transistor Outputs; Suitable for for 3 Wire probes 2 D80D 2 Ch; Relay Output SPDT; Suitable for for 3 Wire probes; AC Power Supply 2 POWER SUPPLY MODULES PSD000 Zone 2 Power Supply; 24 VDC - 0,6 A Output; For AC power of D000 Modules PSD000F Power Supply; 24 VDC - 0,6 A Output; For AC power of D000 Modules with Alarm PSD00 I.S. Power Supply; 4 Parallelable Outputs each with 5 V - 20 ma; SIL 4 PSD00C I.S. Power Supply IIB-IIA Group; 3.5 V -00 ma Output ; SIL PSD520 I.S. Power Supply IIB-IIA Group; 4.5 V -50 ma Output ; SIL PSD200 Series PSD20/IP66 Zone 2 Power Supply; II 3 G EEx na IIC T4; 24 V - 0 A Output; IP66; SIL 200 PSS200 Series PSW250 Zone 2 Power Supply Module; 24 V - 50 A Output; Wall Mounting (DinRail aval.); SIL 6 PSW230 Zone 2 Power Supply Module; 24 V - 30 A Output; Wall Mounting (DinRail aval.); SIL 6 PSM250 Zone 2 Power Supply Module; 24 V - 50 A Output; Rack Mounting; SIL - - PSO250 Zone 2 Power Supply Display/Diagnostic Module; RS-485 ModBus Output. Rack Mounting; Optional - - PSS250-HS-7--D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2 Hot swapping; 50+50 Amps - 482 PSS250-HS-7-2-D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2 Hot swapping; 00+00 & 50+50 Amps - 482 PSS250-HS-7-3-D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2 Hot swapping; N 3 x 50+50 Amps - 482 PSS250-7--D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2; 50+50 Amps - 482 PSS250-7-2-D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2; 00+00 & 50+50 Amps - 482 PSS250-7-3-D 9" Rack for N 6 PSM250 + N PSO250 Module; Zone 2; N 3 x 50+50 Amps - 482 PSS250-HS-3-D 9" Rack for N 2 PSM250 + N PSO250 Module; Zone 2 Hot swapping; 50+50 Amps - 482 PSS250-3-D 9" Rack for N 2 PSM250 + N PSO250 Module; Zone 2; 50+50 Amps - 482 MCHP 8 Blank Panel for empty position of PSS250 rack series - -

Price List 206 ( Rev. dated March st, 206 ) Page # 7 SIL 3 RELAY MODULES D092S D092S-069 D092D D092D-069 D093S Ch; SIL3 Relay; Out: N 2 SPST NO Relay ( for NE Loads & for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or Energized Relay / Energized Load; Not Comp. to L.M. Pulses. Ch; SIL3 Relay; Out: N 2 SPST NO/NC Relay ( for NE Loads & for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or De-energized Relay / Energized Load; Not Comp. to L.M. Pulses. 2 Ch; SIL 3 Relay; Out: N 4 SPST NO Relay (2 for NE Loads & 2 for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or Energized Relay / Energized Load; Not Comp. to L.M. Pulses. 2 Ch; SIL 3 Relay; Out: N 4 SPST NO/NC Relay (2 for NE Loads & 2 for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or De-energized Relay / Energized Load; Not Comp. to L.M. Pulses. Ch; SIL3 Relay; Out: N 2 SPST NO Relay ( for NE Loads & for ND Loads); SIL Note: With Line Open Circuit Detection for NE or ND Loads; Note: Safety Function is De-energ. Relay / De-energ. Load or Energized Relay / Energized Load; Not Comp. to L.M. Pulses. 2 2 D5090S D5090S-086 D509S D5094S D5095S D5096S D5097S Ch; SIL3 Relay for NE Load; SPST NO 5 Amps contacts plus Service Output; SIL Note: Safety Function is De-energized Relay / De-energized Load. Ch; SIL3 Relay for NE Load; SPST NC 5 Amps contacts plus Service Output SIL Note: Safety Function is Energized Relay / De-energized Load. Ch; SIL3 Relay for ND Load; SPDT 5 Amps contacts with Service Output; SIL Note: Safety Function is Energized Relay / Energized Load or De-energized Realy / Energized Load. Ch; SIL3 Relay for NE or ND Load; SPST NO 5 Amps contacts; SIL Note: Safety Function is De-energ. Relay / De-energ. Load or Energ. Relay / Energ. Load; Fault Tolerant for increased availability. Ch; SIL3 Relay for NE or ND Load; SPST NO 5 Amps contacts; SIL Note: Safety Function is De-energ. Relay / Energ. Load or Energ. Relay / De-energ. Load; Fault Tollerant for increased availability. Ch; SIL3 Relay for NE or ND Load; SPST NO 5 Amps contacts; SIL Note: With Line-Load Open and Short Circuit, Supply Voltage; Note: Safety Function is De-energ. Relay / De-energ. Load or Energ. Relay / Energ. Load; Fault Tolerant for increased availability. Ch; SIL3 Relay for NE or ND Load; SPST NO 5 Amps contacts; SIL Note: With Line-Load Open and Short Circuit, Supply Voltage; 2 2 2 2 2 2 2 Note: Safety Function is De-energ. Relay / Energ. Load or Energ. Relay / De-energ. Load; Fault Tollerant for increased availability. D5098S Ch; SIL3 Relay for NE Load; SPST NO 5 Amps contacts plus Service Output; SIL Note: Safety Function is De-energized Relay / De-energized Load. Current consumption limited to 20 ma 2 D5098D 2 Ch; SIL3 Relay for NE Load; SPST NO 5 Amps contacts plus Service Output; SIL Note: Safety Function is De-energized Relay / De-energized Load. Current consumption limited to 20 ma 2 D5290S D5290S/SA D5290S-078 D5290S-078/SA D5290S-079 D5290S-080 D5290S-084 D5290S-09 D529S D5292S Ch; SIL3 Relay for NE Load; SPST NO 0 Amps contacts plus Service Output; SIL Note: Safety Function is De-energized Relay / De-energized Load. Ch; SIL3 Relay for NE Load; SPST NO 0 Amps contacts plus Service Output; SIL Note: Safety Function is De-energized Relay / De-energized Load / Safe Area only / Not Compatible to L.M. Pulses. Ch; SIL3 Relay for NE/ND Load; 2 SPDT + 2 SPST NO 5 Amps contact; SIL Note: Safety Function is De-energ. Relay/De-energ. Load or Energ. Relay/Energ. Load or De-energized Relay/Energized Load. Ch; SIL3 Relay for NE/ND Load; 2 SPDT + SPST NO 5 Amps contacts; SIL Note: Safety Function is De-energ. Relay/De-energ. Load or De-energ. Relay/Energ. Load / Safe Area only / Not Comp. to L.M. Pulses. Ch; SIL3 Relay for NE/ND Load; 2 SPDT + 2 SPST NO 5 Amps contacts; 5Vac Coil ; SIL Note: Safety Function De-energ. Relay/De-energ. Load or De-energ. Relay/Energ. Load Safe Area only / Not Comp. to L.M. Pulses. Ch; SIL3 Relay for NE Load; SPST NO 0 Amps contacts plus Service Output; 5Vac Coil; SIL Note: Safety Function is De-energized Relay / De-energized Load / Safe Area only / Not Compatible to L.M. Pulses. Ch; SIL3 Relay for NE/ND Load; 2 SPDT + 2 SPST NO 5 Amps contacts; 0Vdc Coil ; SIL Note: Safety Function De-energ. Relay/De-energ. Load or De-energ. Relay/Energ. Load Safe Area only / Not Comp. to L.M. Pulses. Ch; SIL3 Relay for NE Load; SPST NO 0 Amps contacts plus Service Output; 230Vac Coil; SIL Note: Safety Function is De-energized Relay / De-energized Load / Safe Area only / Not Compatible to L.M. Pulses. Ch; SIL3 Relay for ND Load; SPDT 0 Amps contacts with Service Output; SIL Note: Safety Function is Energized Relay / Energized Load or De-energized Relay / Energized Load. Ch; SIL3 Relay; Out: N 2 SPST NO Relay ( for NE Loads & for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or Energized Relay / Energized Load; D5292S-093 D5292D D5292D-093 D5293S D5294S Ch; SIL3 Relay; Out: N 2 SPST NO/NC Relay ( for NE Loads & for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or De-energized Relay / Energized Load; 2 Ch; SIL 3 Relay; Out: N 4 SPST NO Relay (2 for NE Loads & 2 for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or Energized Relay / Energized Load; 2 Ch; SIL 3 Relay; Out: N 4 SPST NO/NC Relay (2 for NE Loads & 2 for ND Loads); SIL Note: Safety Function is De-energ. Relay / De-energ. Load or De-energized Relay / Energized Load; Ch; SIL3 Relay for NE Load; + SPST NO 4 Amps contacts plus Fault Output; SIL Note: With Line-Load Open and Short Circuit, Supply Voltage, & Relay Coil Short Circuit Detection; RS485 Output; Note: Safety Function is De-energized Relay / De-energized Load. Ch; SIL3 Relay for ND Load; 2 +2 SPST NO 4 Amps contacts plus Fault Output; SIL Note: With Line-Load Open and Short Circuit, Supply Voltage, Hearth Leakage & Relay Coil Short Circuit Detection; RS485 Output; 2 2 Note: Safety Function is De-energ. Relay / De-energ. Load or Energ. Relay / Energ. Load; Fault Tolerant for increased availability. Ch; SIL3 Relay for ND Load; 2 +2 SPST NC 4 Amps contacts plus Fault Output; SIL D5295S Note: With Line-Load Open and Short Circuit, Loss of Power, Earth Leackage Detection; RS485 Output; Note: Safety Function is De-energ. Relay / Energ. Load or Energ. Relay / De-energ. Load; Fault Tollerant for increased availability.

Price List 206 ( Rev. dated March st, 206 ) Page # 8 HART MULTIPLEXER D5400 Series D5400 Hart Multiplexer Master; Compatbile with Hart Multiplexer boards TB-D5000-HRT-00 & 002; SIL - 2 SURGE PROTECTION DEVICES D9000 Series D9024S Ch; Floating signal circuit SPD (AI,AO,DI,DO); Din-rail version; disconnect knife; Nom.Volt. 24 VDC; SIL 6 D9324S Ch; Floating signal circuit SPD (AI,AO,DI,DO); Screw-on version; IP67; Nominal voltage 24 VDC; SIL - ISOLATORS FOR NON IS APPLICATIONS D6000 Series D605S Ch; 4-20 ma, 2/3-Wire IN; 4-20mA Source OUT; Hart; S/K Versions Available; SIL 2 D605D 2 Ch; 4-20 ma, 2/3-Wire IN; 4-20mA Source OUT; Hart; S/K Versions Available; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs D604S Ch; 4-20 ma, 2/3-Wire IN; ma/v Sink/Source OUT; Hart; SIL 2 D604D D622Q 2 Independent Ch; 4-20 ma, 2/3-Wire IN; ma/v Sink/Source OUT; Hart; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs 4 Ch; 4-20 ma IN/OUT; Configurable as Duplicator, Triplicator or Quadruplicator Note: Unit is field configurable as Duplicator, Triplicator or Quadruplicator; IN - 2,3 or 4 OUTs 2 4 2 D6020S Ch; 4-20 ma, I/P Driver; Transparent Open-Short Circuit Alarm Function; Hart SIL 2 D6020D 2 Independent Ch; 4-20 ma, I/P Driver; Transparent Open-Short Circuit Alarm Function; SIL Note: Unit is field configurable as Duplicator IN - 2 OUTs D6030S Ch; SPDT Relay Output; Line Monitoring Function; SIL 2 D6030D 2 Independent Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL Note: Unit is field configurable as Duplicator: IN / 2 OUTs or IN - + OUT (DI + LFD) D603S Ch; NO/NC Solid State Output; Line Monitoring Function; SIL 2 D603D 2 Independent Ch; 2 NO/NC Transistor Out; Line Monitoring Function; SIL Note: Unit is field configurable as Duplicator: IN / 2 OUTs or IN - + OUT (DI + LFD) D623E 8 Ch; NO/NC Solid State Output; Line Monitoring Function; SIL 8 D6034S Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 2 D6034D 2 Independend Ch; Trasparent to Contact-Prox & Line Monitoring Function; SIL D6036S Ch; SPDT Relay Output; Line Monitoring Function; No G3 Coating; SIL 2 D6036D 2 Ch; 2 SPST Relay Outputs; Line Monitoring Function; No G3 Coating; SIL D6037S Ch; NO/NC Solid State Output; Line Monitoring Function; No G3 Coating; SIL 2 D6037D 2 Ch; 2 NO/NC Solid State Output; Line Monitoring Function; No G3 Coating; SIL D6254S Ch; Smart-Hart; 0/4-20 ma Input; ma-v Output + 2 Trip Amp; Fully Softw. Program; SIL D6072S Ch; TC-RTD-Tx Pot Input; ma plus Burnout Alarm Outputs; Fully Programmable, SIL 2 D6072S-087 Ch; RTD Input; RTD Output, SIL 2 D6072D 2 Ch; TC-RTD-Tx Pot Input; ma Outputs; Fully Programmable, SIL Note: Unit is field configurable as Duplicator IN - 2 OUT D6273S Ch; TC-RTD-Tx Pot Input; ma Outputs; + 2 Trip Amplifiers; Fully Programmable, SIL I.S. DISPLAY MODULES T3000 Series T300S 4-20 ma Intrinsically Safe 4.5 digit Indicator; Loop Powered; IP 65; Size 44x44x6 mm; 44 Note: 20 mm high Display; Suitable for Wall Mounting; Flush or Pipe mounting using OPT3092-OPT3093 OPT3092 Stainless Steel Bracket set and Gasket for Flush-Panel Mounting - - OPT3093 Stainless Steel Bracket set for 50-70 mm Pipe Mounting & SS set for Flush-Panel Mounting - -

Price List 206 ( Rev. dated March st, 206 ) Page # 9 OPTIONS & ACCESSORIES BUS Extra Price for Power Bus Housing; Add: " /B " to model number - OPT096 Kit For Bus Mounting Include: N 2 MOR06, N MOR07, N MOR0, N 2 MCHP065 - - OPT097 Kit For Bus Mounting Include: N MOR05, N MOR0, N 2 MCHP065 - - MOR 009 2.5sqmm Terminal Block 4p, Blue Color (RAL505); Number Marking to be specified - - MOR 00 2.5sqmm Terminal Block 4p, Gray Color (RAL7042); Number Marking to be specified - - MOR 06 Din Rail Stopper - 0 MOR 05 Plug-in terminal block male, vertical out, for Power Bus - - MOR 07 Plug-in terminal block male, horizontal out, for Power Bus - - MOR 0 Plug-in terminal block female, horizontal out, for Power Bus - - MOR 046/2 Terminal Block for APN0005: Passive output for D05XX / D060S / D07XX ( for each channel) - 5 MOR 058 Terminal Block for PLC Pulse Damping of D09X relay - 5 MOR 062 Terminal Block with resistors KR Serie/0KR Parallel for LFD; Blue, Screw Connection; L70xH65xW5.2mm - 5 MOR 062/C Terminal Block Cover for MOR 062, blue; one needed for each group - 2 MCHP 044 D000 Serie Enclosure Gray; Marking to be specified - MCHP 06 D000 Serie BUS Enclosure Gray; Marking to be specified - MCHP 065 Din Rail Anchor for terminal block side of the Power Bus - 0 PPC090 Pocket Portable Configurator required to configure programmable units; includes CABF004 - - PPC092 PC Adapter to configure D000 series programmable units; Include CABF004-00, USB Adapter & SWC090 - - SWC090 Software for modules configuration via PPC092; Available on our web site free of charge - - CABF004 RJ 6 Poles Male-Male cable for connecting PPC090-PPC092 to D000 Serie Modules; - - CABF00 Sub D 9 Poles Female-Female Nul-Modem; 800 mm lenght - - CABF02 Load cells cable with N 3 twisted & screened sqmm pairs + overall screen (price x meter) - - USB adapter USB to serial line RS-232 Adapter; - - OPT09 Cold Junction Compensator to be ordered for THCs Inputs; One required for each input - GEST_CONF Extra Price for Module Configuration according to Customer Specification - - MCHP 064 Tagplate in policarbonate material - - MCHP 090 72 mylar white lables for tagging (A4); Software for compilation on our web site free of charge - - MCHP 39 5 mm Spacer for spacing of modules on DIN Rail TS 35-5 MCHP 06/3 Dummy Bus module with Bus connector removed - D000D Dummy module to be used with custom boards PBCO series - D09S Common Alarm Module for with Fault Output, SPDT Relay Output D002S Redundant Power Connection & Common Alarm Module (SPST) for ; Max 4 Amp CABF030 Cable Assembly for PBCO; Connect Module Safe Area terminals to Board - - D000R 9" Rack unit, 3 units High, suitable for 6 D000 series modules - 482 D5000, D6000 & D9000 Series JDFT 049 2 mm Power Bus Connector for DIN Rail Mounting; One needed for each BUS Module D5000-D6000-2 JDFT 050 mm Power Bus Connector for DIN Rail Mounting; One needed for each BUS Module D5200-D6200 - MCHP96 Bus End Stopper; One for each end of Bus Required - 0 OPT5096 Kit For Bus Mounting Include: N MOR07, N MOR0, N 2 MCHP96 Note: One needed for each group of modules - - MOR 07 Plug-in terminal block male, horizontal out, for Power Bus - - MOR 0 Plug-in terminal block female, horizontal out, for Power Bus - - MOR 04 2.5sqmm Terminal Block 4p, Blue Color (RAL505) D5200-D6200; Number Marking to be specified - - MOR 05 2.5sqmm Terminal Block 2p, Blue Color (RAL505) D5000-D6000; Number Marking to be specified - - MOR 052 2.5sqmm Terminal Block 2p, Gray Color (RAL7042) D5000-D6000; Number Marking to be specified - - MOR 053 2.5sqmm Terminal Block 4p, Gray Color (RAL7042) D5200-D6200; Number Marking to be specified - - MOR 062 Terminal Block with resistors KR Serie/0KR Parallel for LFD; Blue, Screw Connection; L70xH65xW5.2mm - 5 MOR 062/C Terminal Block Cover for MOR 062, blue; one needed for each group - 2 MCHP 39 5 mm Spacer for spacing of modules on DIN Rail TS 35-5 MCHP83 Blue Terminal Block Plug 2 mm D5000 - - MCHP84 Grey Terminal Block Plug 2 mm D5000-D6000 - - MCHP85 Blue Terminal Block Plug mm D5200 - - MCHP86 Grey Terminal Block Plug mm D5200-D6200 - - MCHP242 End Cover for D9024S - 2 LABL0 Front Label Blue Colour (RAL505) 2mm, Page of 60 pcs D5000 - - LABL02 Front Label Yellow Colour (RAL08) 2mm, Page of 60 pcs D5000 - - LABL03 Front Label Blue Colour (RAL505) mm, Page of 60 pcs D5200 - - LABL04 Front Label Yellow Colour (RAL08) mm, Page of 60 pcs D5200 - - LABL06 Front Label Gray Colour (RAL7042) 2mm, Page of 60 pcs D5000-D6000 - - LABL07 Front Label Gray Colour (RAL7042) mm, Page of 60 pcs D5200-D6200 - - D5000D Dummy module with Hazardous Area & Safe AreaTerminal blocks; 2 mm - 2 D5200D Dummy module with Hazardous Area & Safe Area Terminal blocks; mm - D5000D/TBH Dummy module with Hazardous Area Terminal blocks; 2 mm - 2 D5200D/TBH Dummy module with Hazardous Area Terminal blocks; mm - D5000D/ENC Dummy module without Terminal blocks; 2 mm - 2 D5200D/ENC Dummy module without Terminal blocks; mm - D6000D Dummy module with Field & Control Room Terminal blocks; 2 mm - 2 D6200D Dummy module with Field & Control Room Terminal blocks; mm - D520S Common Alarm Module (SPST) for D5000/D6000 Series; D5202S Redundant Power Connection & Common Alarm Module (SPST) for D5000/D6000 Series; Max 4 Amps SWC5090 Software for configuration available on our web site free of charge - - PPC 5092 PC Adapter to configure D5000 & D6000 series programmable units; Include SWC5090 Software. - - G3_D5000 Extra Price for G3 coating for Non Coated SIL 2 modules; Add: " /G " to model number - - G3_TB Extra Price for G3 coating for Termination Boards; Add: " /G " to model number - - GEST_CONF Extra Price for Module Configuration according to Customer Specs. - -

Price List 206 ( Rev. dated March st, 206 ) Page # 0 DOCUMENTATION DOC_CERT_SAFETY Copy of I.S. Complete Certificate; Specify certificate type (IEC-Ex; ATEX; FM, UL, GHOST;..) - - DOC_CERT_TEST Copy of Individual Test certificate; One per each ordered instrument - - DOC_MANUAL Copy of Instruction Manuals in English Language; - - DOC_CONFORMITY Copy of EC Declaration of Conformity; - - DOC_CD_GM Copy of complete documentation set on CD Rom; One free copy included with each order; - - DOC_CERT_ORIGIN Certificate of Origin; Available only for export area outside of EC - - DOC_CERT_ORIG_GMI Certificate of Origin issue by GMI; Available only for export area outside of EC - - DOC_POSTER_EX Poster Intrinsic Safety Applications - - DOC_POSTER_SIL Poster SIL Applications - - DOC_SHORT_FORM_GM Short Form Catalogue - - Note Certificates, Data Sheets, Instruction Manuals free from our web site: www.gmintsrl.com TEMPERATURE AND DIGITAL I.S. MULTIPLEXER D200M D20M D2030M D2050M 6 Analog-temperature Input channels Intrinsically Safe Multiplexer unit, Note: For installation in hazardous Areas, in congiunction with the D2050M unit, Note: Din Rail Mounting. Up to n 4 D200M modules can be connected to a D2050M unit 6 Analog-temperature Input channels Intrinsically Safe Multiplexer-Expander unit, Note: For installation in hazardous Areas, in congiunction with the required D200M unit, Note: Din Rail Mounting, Up to n 3 D20M modules can be connected to a D200M unit. 32 Digital Input channels Intrinsically Safe Multiplexer unit, Note: For installation in hazardous Areas, in congiunction with the D2050M unit, Note: Din Rail Mounting, Up to n 4 D2030M modules can be connected to a D2050M unit Supply Interface unit with redundant comunication up to 4 Multiplexer units D200M-D2030M, Note: For installation in Safe Areas, Din Rail Mounting, Note: RTU Modbus redundant output line RS485 D2000 Series 6 0 6 0 D2052M 32 Relay Output Module to repeat D2030M input, connection to D2050M 32 0 D2053M 32 Transistor Output Module to repeat D2030M input, connection to D2050M 32 0 OPTIONS & ACCESORIES D2000 Series 32 0 256 0 D090Q 4 Channels Shunt Module for ma inputs of D200M & D20M Units 4 D094Q 4 Channels Divider Module for V inputs of D200M & D20M Units 4 OPT209 Cold Junction Compensator to be ordered for THCs Inputs Mounted on Terminal Block - Note: compensator per each D200M - D20M units OPT2094 Wall Mounting KIT for GM 2300 Series Enclosures - - OPT2095 Front Door Mounting KIT for GM 2300 Series Enclosures - - MOR 06 Din Rail Stopper - 0 MOR 035 2.5sqmm Terminal Block 4p, Blue Color (RAL505); - - MOR 045 Double Terminal Block to anchor CABF008 Line wires & shield - - CABF005 5 cm flat cable to interconnect D200M - D20M units - - CABF006 30 cm flat cable to interconnect D200M - D20M units - - CABF007 50 cm flat cable to interconnect D200M - D20M units - - CABF008 Cable to interconnect D2050M with D200M or D2030M units (price per meter), - - CABF0 5 cm flat cable to interconnect D2050M - D2052M - D2053M units - - CABF023 30 cm flat cable to interconnect D2050M - D2052M - D2053M units - - CABF024 50 cm flat cable to interconnect D2050M - D2052M - D2053M units - - CABF00 Sub D 9 Poles Female-Female Nul-Modem, 800 mm lenght for RS-232 connection - - SWC2090 Software for configuration available on our web site free of charge - - PRE-ASSEMBLED & FULLY WIRED ENCLOSURES D2000 Series GM2320-SS-08- Stainless Steel Enclosure, for installation of N D2050M Module. GM2320-SS-20- Dim.: 400x300x200 mm. With a total of N 4 M20-DN07 + N 4 M20-DN. Nichel Plated Brass Cable Glands. Note: Suitable for N - D2050M module Stainless Steel Enclosure, for installation of N D200M Module. GM2320-SS-36- Dim.: 400x300x200 mm. With a total of N 6 M20-DN07 + N 4 M20-DN. Nichel Plated Brass Cable Glands. Note: Suitable for N - D200M module Stainless Steel Enclosure, for installation of N D2030M Module. GM2330-SS-36- Dim.: 400x300x200 mm. With a total of N 32 M20-DN07 + N 4 M20-DN. Nichel Plated Brass Cable Glands. Note: Suitable for N - D2030M module Stainless Steel Enclosure, for installation of N 2 D200M or N D200M & N D20M Modules. Dim.: 600x400x200 mm. With a total of N 32 M20-DN07 + N 4 M20-DN. Nich. Plated Brass Cable Glands + 32 NB Caps. Note: Suitable for N - D2030M module or N 2 - D200M modules or N - D200M + N D20M modules GM2330-SS-52- Stainless Steel Enclosure, for instal. of N D200M & N D2030M Modules or N D200M & N 2 D20M Mod. Dim.: 600x400x200 mm. With a total of N 48 M20-DN07 + N 4 M20-DN. Nich. Plated Brass Cable Glands + 6 NB Caps. Note: Suitable for N 3 - D200M module or N - D200M + N 2 D20M modules or N - D200 + N - D2030 modules GM2330-SS-68- Stainless Steel Enclosure, for installation of N 4 D200M / D20M or N 2 D2030M Modules. Dim.: 600x400x200 mm. With a total of N 64 M20-DN07 + N 4 M20-DN. Nichel Plated Brass Cable Glands. Note: Suitable for N 2 D2030M mod. or N 4 D200M mod. or N D200M+N 3 D20M mod. or N 2 D200M+N 2 D20M mod.

Price List 206 ( Rev. dated March st, 206 ) Page # DSC Euro Each GMI Eq. ELCON'S ADAPTERS 000 SERIES Note: TO ORDER PLEASE SPECIFY COMPLETE ORIGINAL PART NUMBER IN EXAMPLE: "025-A-0-0242-AA" Analog Input, Power Supply Repeaters 0 V - ma Input / V - ma output fullly programmable 25 02 V - ma Input / V - ma output fullly programmable 2 25 020 2/4W TX Supply and Repeat, Setpoint Trip Amplifier, Relay Output 2 x SPDT, Smart Tx Compatible 25 02 Analog Input Repeater, Smart Tx Compatible, (non Honeywell Compatible) 25 0 Analog Input Repeater, Smart Tx Compatible, (non Honeywell Compatible) 2 25 023 Analog Input Repeater, Floating Output 25 025 Analog Input Repeater, Smart Tx Compatible 25 025G Analog Input Repeater, Smart Tx Compatible, 3 Port Isolation, Isc=93mA 25 026 Analog Input Repeater, Smart Tx Compatible 2 25 026G Analog Input Repeater, Smart Tx Compatible, 3 Port Isolation, Isc=93mA 2 25 027 Tx or Current Source Repeater, 2 Setpoint Trip Amplifier, Relay Output 2 x SPST, Smart Tx Compatible 25 029 Analog Input Repeater, Smart Tx Compatible, Sink/Source Output, Isc=93mA 25 030 Analog Input Repeater, Smart Tx Compatible, Sink/Source Output, Isc=93mA 2 25 Analog Output, Powered Isolating Drivers for I/P 03 Analog Output Repeater, Bus Powered 25 032 Analog Output Repeater, Bus Powered 2 25 033 Analog Output Repeater, Loop Powered 25 034 Analog Output Repeater, Loop Powered 2 25 037 Analog Output Repeater, Bus Powered for Smart I/P and Positioner 25 038 Analog Output Repeater, Bus Powered for Smart I/P and Positioner 2 25 Anolog Signal and Temperature Converters Fully Programmable 06 TC or mv Input, Linear 4-20 ma/-5 V Output; Including C.J. Compensator 25 062 TC or mv Input, Linear 4-20 ma/-5 V Output; Including C.J. Compensator 2 25 065 TC or mv Input, Linear mv Output; Including C.J. Compensator 25 066 TC or mv Input, Linear mv Output; Including C.J. Compensator 2 25 07 RTD or Tx Pot Input, Linear 4-20 ma/-5 V Output 25 072 RTD or Tx Pot Input, Linear 4-20 ma/-5 V Output 2 25 073 RTD or Tx Pot Input, Linear 4-20 ma/-5 V Output, 3 Port Isolation 25 074 RTD or Tx Pot Input, Linear 4-20 ma/-5 V Output, 3 Port Isolation 2 25 090 Strain Gauge or Load Cell Input, 0-20/4-20 ma, 0-5/-5/0-0 V Output 25 Analog Signal and temperature Trip Amplifiers Fully Programmable 30 V/mA Input, 2 Setpoint, Relay Output, 2 x SPDT 25 3 V/mA Input, 2 Setpoint, Relay Output, 2 x SPDT 25 360 TC /mv Input, 2 Setpoint, Relay Output, 2 x SPST, including Compensator 25 36 TC /mv Input, 2 Setpoint, Relay Output, 2 x SPST, including Compensator 25 370 RTD/Pot Input, 2 Setpoint, Relay Output, 2 x SPST 25 37 RTD/Pot Input, 2 Setpoint, Relay Output, 2 x SPST 25 90 Tx or Current Source Repeater, 2 Setpoint Trip Amplifier, Relay Output 2 x SPST, Smart Tx Compatible 25 Digital Input Contact-Proximity Repeater 82 Namur Prox/Contact Input Repeater, Relay Output ( x DPDT) 25 8 Namur Prox/Contact Input Repeater, Relay Output (2 x SPDT) 2 25 84 Namur Prox/Contact Input Repeater, Transistor Output 25 842 Namur Prox/Contact Input Repeater, Transistor Output 2 25 86 Safe Area Contact Input Repeater, Relay Output ( x SPDT) 25 862 Safe Area Contact Input Repeater, Relay Output (2 x SPDT) 2 25 Digital Output Drivers for Solenoid Valves, LEDs, Horns 87 Digital Output Repeater for Solenoid Valves 25 872 Digital Output Repeater for Solenoid Valves 2 25 872 Digital Output Repeater for Solenoid Valves, ONLY CODE 872-U-0-0070-WW (with Series D5000 Adapter) 2 25 873 Digital Output Repeater for Solenoid Valves 25 874 Digital Output Repeater for Solenoid Valves 2 25 874 Digital Output Repeater for Solenoid Valves, ONLY CODE 874-U-0-0070-WW (with Series D5000 Adapter) 2 25 88 Digital Output Repeater for Solenoid Valves 25 882 Digital Output Repeater for Solenoid Valves 2 25 Note CHECK VALVE I.S. AND FUNCTIONAL PARAMETERS FOR PROPER BARRIER SELECTION D04*Q Frequency to Analog Converter + Pulse Repeater 89 Pulse Input, Prox or Mag Sensor, 4-20mA/-5 V Output, Pulse Repeater 25 893 Pulse Input, Prox or Mag Sensor, 4-20mA/-5 V Output, Pulse Repeater 25