S900 Remote I/O System Intrinsic safety in the field ABB

Similar documents
General. Remote I/O A4/1.

remote I/O future inside

remote I/O future inside

Your Global Automation Partner. excom I/O System

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Intrinsically Safe Barriers

Symphony Plus S+ Control: AC 870P

Symphony Plus S+ Control & I/O: MR Series (Melody Rack)

S900 I/O DTM 6.x. System Version 6.0. Power and productivity for a better world TM

MTL8000-2/x Series Modular I/O

Control IT S800 I/O System

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Technical Description

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

General Specifications

LB Remote I/O. CEAG Sicherheitstechnik GmbH 256

Trusted Strategic Partners in Process Automation. Alliance Member

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Ruchiman Priatna (Control Technology) Freelance The easy-to-use distributed control system

M-series Profibus DP Series 2 Plus Interface Card

POINT I/O Family. Chapter. Overview

POINT I/O Family. Chapter. Overview

SIMATIC. Distributed I/O Device ET 200iSP. Preface, Contents. Product Overview Getting Started with Commissioning. Configuration Options.

CPU module for zone 2 Series 9442/35

POINT I/O Family. Chapter. Overview

M-series Intrinsically Safe I/O

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

GE Intelligent Platforms PAC8000 RTU

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Oomesh Maharaj, Freelance - MEA Region Product Manager, Control Technologies, Tech days Cape Town 2014

PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001

APPLICATION GUIDE. Interface Modules IM Series.

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Signal conditioners with Functional Safety The MACX ranges

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

General Specifications

S800 I/O DTM 6.0. System Version 6.0. Power and productivity for a better world

POINT I/O Family. Chapter. Overview

PROFIBUS and Integrated Safety architectures in Ex areas

Your Global Automation Partner. IM Interface Technology in Modular Housings

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Flow Measurement SITRANS F C

Backplane. Allen-Bradley. System integration. Backplane

SIRIUS Motor Management and Control Devices

M-series Profibus DP Series 2 Plus Interface Card

MLC 9000 Bus Compatible PID

AC 800M for Compact Product Suite Outline of all modules

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Breaking the Limits of Analog Technology. Key attributes of the technology that makes FOUNDATION fieldbus suitable for process control

Embedded systems extend automation

POINT I/O Family. Chapter. Overview

Compact Control Builder AC 800M and S800 I/O ABB

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Sense it! Connect it! Bus it! Solve it! REMOTE I/O excom

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

SOLUTIONS FOR THE PHARMACEUTICAL INDUSTRY Solutions for the Pharmaceutical Industry

INSTALLATION, OPERATION, CONFIGURATION AND MAINTENANCE MANUAL September/2016 VTT10-PH. HART TEMPERATURE TRANSMITTER panel model

Backplane. System integration. Backplane

System 800xA The Power of Integration. 800xA Device Management and Fieldbus Overview

S-series DeviceNet Interface Card

MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

Freelance Process Automation Made Easy

Control IT. Features and Benefits. Overview. Harmony Rack Input/Output

S800 I/O. Modules and Termination Units with Intrinsic Safety Interface. Power and productivity for a better world TM

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Operating Instructions

Refer to attachment for more details. Andreas Meyer

SIMATIC Distributed I/O Product information for the ET 200iSP Operating Instructions (A5E ) 01/2010

100mm Process Indicator Recorder

POINT I/O Family. Chapter. Overview

IS1 remote I/O. ready for the future

S800 I/O ABB Automation

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

RSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804 Digital Input Module with Time Stamp EP-12F4

PAC BI-DP BIM and 8701-CA-BI Carrier

ACT20X-(2)HTI-(2)SAO Temperature/mA converter. Safety Manual

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Intrinsically Safe Remote I/O System

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

Technical Information Fieldgate SFG500

Using the WirelessHART transmitter TTF300-W as repeater to extend the availability of a WirelessHART network

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

Project Execution Best Practices

FICHA TÉCNICA DE PRODUTO

C160 Wall-/Pipe Mounted Universal Process Indicator

Backplane. System integration. Backplane

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

S-series Profibus DP Interface Card

Distributed Intrinsically Safe Fieldbus Applications

ABB Fieldbus Infrastructure and Network Devices An overview

Product Description. Altus S. A. 1

Transcription:

S900 Remote I/O System Intrinsic safety in the field ABB

2 S900 REMOTE I/O SYSTEM INTRINSIC SAFETY IN THE FIELD The S900 Remote I/O System 01 Example of Field housing FH660S in stainless steel with complete certification according to "ATEX". S900 is a remote I/O family designed for application with rated hazardous areas according to ATEX. The I/O system can be safely located directly in ATEX Zone 1 and 2, which can save immense wiring cost and makes the need of barriers obsolete. It also makes life easy in production phase, as maintenance of the I/O is easy as in non-rated areas. S900 I/O incorporates complete redundant networking capability, including redundancy in power supply, communication interface and PROFIBUS DP connection. Field housings For field mounting and mounting in hazardous areas, the S900 needs to be located into field housings with a protection class IP54 as minimum. For such cases, standard solutions with Field Housing series can be selected in the product range (refer to price list). The Field Housings are designed for wall-mounting and are certified in accordance with ATEX for installation in Zone 1. They consist of stainless steel and are ready-wired. Further information is available in I/O Datasheet Catalog. Main areas of application are in the chemical industry, the pharmaceutical industry and, the oil and gas industry. Throughout it s proven track record and wide temperature range and coating, the S900 I/O has been used in many areas where durable and long standing equipment is needed. Extended diagnostic functions and the use of HART -compliant field devices in the fieldbus system reduce the maintenance effort and therefore, lead to savings throughout the service life of the plant. For further information please contact your local ABB representative or visit our web. 01 The S900 I/O family is ideal for use in Process Control Systems and has proven track record with all of ABB s systems, like: System 800xA Advant Master AC 870P / Melody / Symphony Plus Freelance and many more. Three different versions of S900 are available, tailored to meet the needs of customers. Nevertheless, a uniform planning and engineering philosophy can be used both for the assembly of the certified S900 I/O in the various hazardous zones and for signaling. The following S900 series are available: S series for applications in Zone 1 hazardous areas B series for applications in Zone 2 hazardous areas N series for applications in non-hazardous areas Series Assembly Field devices / signals S series In Zone 1 In Zones 2, 1, and 0 (intrinsically safe signals) B series In Zone 2 In Zones 2, 1, and 0 (intrinsically safe signals) N series In safe areas In safe areas Hazardous area approval ATEX Zone 1 (Blue TU921S) ATEX Zone 2 (Blue TU921B) No* (Black TU921N) * Field devices mounted in Zone 1/Zone 0 can be connected to N- Series with additional IS barriers; a benefit of IS modules of S- and B-Series.

INTRINSIC SAFETY IN THE FIELD S900 REMOTE I/O SYSTEM 3 Advantages at a glance Designed for intrinsically safe applications in hazardous areas Integrated barrier function with hot pluggable modules and automatic slot addressing High availability due to redundancy in the power supply as well as in communication Minimum maintenance effort as a result of hot swap capability in rated hazardous areas, selfdiagnostics, remote engineering capabilities Simplified project handling with pre-installed, fully certified extended safety field housings Easy project planning and efficient engineering Customer benefits Installation close to production cell saves cabling cost Responsibility for explosion protection taken over by vendor (pre-mounted for installation in field housings including ATEX certification for Zone 1) No plant-specific documentation and engineering required Simplified Ex-acceptance test procedure for plants used in hazardous areas (pre-mounted field house including ATEX certification Zone 1) Straightforward preparation of offers NAMUR inputs Binary 48 V Binary Relay Analog Unipolar Temperature RTD Temperature T/C HART Intrinsic safety I/O Features S900 Digital I/O modules DX910,N* Digital output modules DO910,N* DO930N Pulse input modules DP910,N* Analog input modules AI910,N* AI930,N* AI931,N* AI950,N* Analog output modules AO910,N* AO920,N* AO930,N* * For details about S900 I/O please refer to the S900 catalog, document number 3BDD010420.

4 S900 REMOTE I/O SYSTEM INTRINSIC SAFETY IN THE FIELD The S900 building blocks The S900 interface family is based on a passive backplane suitable for assembly in control room or for field assembly in an appropriate housing, e.g. extended Safety Fieldhousing FH660S. The passive backplane contains all terminal units for field circuits, communication and power supplies. Interface modules are plugged into the backplane in up to 16 slots. The backplane has two slots for power supply units and two slots for communication interfaces to achieve a full communication and power supply redundancy. The interface modules have up to eight channels, while analog function modules can connect up to four channels. Therefore, up to 128 digital or 64 analog channels or any mix of both can be connected per station. In a standard cabinet layout in Non-Ex areas, about 400 to 600 channels can fit with a typical mix of I/Os. Some of the special features are: Flexibility for a large number of different applications: assembly in various hazardous areas or standard non-hazardous areas, as well as various variants and solutions Good price/performance ratio as external barriers for the field circuits have been removed and costs are cut in terms of cabling, installation, hardware, and maintenance High availability due to redundancy Simplified maintenance due to auto diagnostics and the provision of diagnostic data via the fieldbus as well as signaling through LEDs at the S900 station itself Easy configuration either using FDT/DTM or by means of GSD files, allowing connection to practically all process control systems Easy handling thanks to the hot-swap capability of all components during operation Description of the S900 system S900 provides input and output modules needed for intrinsically safe connection of field signals. In S900 modules, the field signals are digitized and electrically isolated then made available via PRO- FIBUS DP for the N-System or PROFIBUS DP-IS for the S-/B-System. Higher-level process control systems, programmable logic controls, or SCADA systems use this intrinsically safe fieldbus to communicate with the communication interface. One and the same fieldbus network is used for the configuration of the individual S900 stations, the cyclical data exchange, all acyclic services, and communication with HART field devices. When it comes to installation and maintenance, all input/output modules can be replaced easily and quickly as the modules and the optionally redundant communication interfaces of systems placed in Zone 1 can be removed and plugged in while operation is running, without affecting the communication of the remaining modules. Integrated, encapsulated disconnection mechanisms also allow the power supply units to be exchanged without switching off the power. As a result of its rugged, space-saving design, combined with protection against environmental influences, the S900 remote I/O system is the solution of choice for direct, cost-saving on-site deployment in Zone 1 or 2 hazardous areas as well as in non-hazardous areas.

INTRINSIC SAFETY IN THE FIELD S900 REMOTE I/O SYSTEM 5 Integration into the control system The S900 remote I/O can be configured and parameterized directly from the engineering tool integrated into the process control system. The configuration can be carried out using DTM interface or using GSD files. S900 Remote I/O is highly integrated in ABB s Process Control Systems. For Freelance, you have the option to either use DTMs or GSD based template technology. For System 800xA/ AC 800M controller, Hardware Definition file exists. This allows for easy engineering of the components as well as parameterizing connect HART field devices. Commissioning: Configuring the module types (which module in which slot and if HART secondary variables should be read out cyclically) Setting all module parameters (0/4..20mA; behavior in the event of an error, etc.) Automatically describing the I/O data (channels) to facilitate the connection to the function chart Monitoring and simulating the I/O data to support commissioning Passing the configuration data to the master s download mechanism Operation: Displaying all system specific, module specific, and channel specific S900 diagnostic information so that errors can be pinpointed effectively Displaying the diagnostic information of HART devices Maintenance: Possible to identify the components, e.g. displaying hardware and software versions or batch numbers No external signal conditioning or marshalling necessary S900 offers a large number of different input and output modules: Input modules both with and without integrated galvanic isolated barrier function. When used in hazardous areas, no additional barriers are needed. Input modules with a direct temperature signal input for 3-wire/4-wire resistance thermometers. Thermocouples with internal reference junction compensation. NAMUR inputs and outputs for binary contacts Output modules for directly controlling positioners, actuators, and solenoid drivers or for controlling valves, LEDs, and relays. S900 makes it possible to connect 2-wire field devices directly. Substantial savings can be achieved during installation thanks to the fact that the need for separate marshalling, provision of power, and fuse systems is eliminated. Using the HART technology The S900 I/O remote system enables you to benefit from the advantages and functions of any intelligent HART field devices you already have installed. Can be configured and parameterized using the fieldbus Cyclical scanning of secondary variables such as the feedback from positioners Reduced wiring effort and less hardware thanks to multi variable HART devices Support for HART status and diagnosis Access to maintenance functions of the HART field device

6 S900 REMOTE I/O SYSTEM INTRINSIC SAFETY IN THE FIELD The S900 Remote I/O System 01. Communication interface CI920AS/B/N Fieldbus protocol PROFIBUS DP V1 HART over PROFIBUS Line or media redundancy via two coupling modules Electrical isolation between field bus, power Diagnosis, configuration and parameterization via PROFIBUS 02. Digital I/O modules DX910S/B/N Input for dry contacts or proximity switches (NAMUR) Output for low power intrinsically safe valves Electrical isolation between input / bus and input / power Common return for all inputs / outputs Configurable as a mixture of inputs and outputs 8 I/O channel 03. Solenoid driver DO910S/B/N Output for intrinsically safe valves or alarms Integrated driving power Electrical isolation channel to channel 04. Relay output DO930N Relay output for higher switching power Output configurable as NO or NC contact Electrical isolation channel to channel Configurable as 4 x changeover contact Configurable as 6 x NO contact 05. Frequency input DP910S/B/N Frequency input for dry contacts or proximity switches Electrical isolation between input / bus and input / power Frequency measurement or counting applications 2 Function blocks Reset via fieldbus or control input Status outputs / Direction recognition 06. Analog input AI910S/B/N Power supply for 4...20 ma loop powered 2-wire trans mitters Electrical isolation between input / bus and input / power Common return for all inputs 01 02 03 04 05 06

INTRINSIC SAFETY IN THE FIELD S900 REMOTE I/O SYSTEM 7 07. Analog input, HART, AI930S/B/N Power supply for 4...20 ma loop powered 2-wire trans mitters Electrical isolation between input / bus and input / power Common return for all inputs Cyclic secondary HART variables Transmission of HART frames via the fieldbus 08. Analog input, HART, pass., AI931S/B/N Passive inputs for 0/4...20 ma Electrical isolation between input/bus and input/power Common return for all inputs Cyclic secondary HART variables Transmission of HART frames via the fieldbus 09. Temperature input AI950S/B/N Pt 100, Pt 1000, Ni 100, 0...3 kohm in 2-/3-/4- wire connection Thermocouple Type B, E, J, K, L, N, R, S, T, U, mv Internal or external cold junction compensation Electrical isolation between input/bus and input/power Electrical isolation channel to channel 10. Analog output AO910S/B/N Output signal 0/4...20 ma for actuators Output with common ground 11. Analog output, isolated AO920S/B/N Output signal 0/4...20 ma for actuators Electrical isolation channel to channel 12. Analog output, HART, AO930S/B/N Output signal 0/4...20 ma for actuators Output with common ground Cyclic secondary HART variables Transmission of HART frames via the fieldbus For further information please contact your local ABB representative or visit our web: https://new.abb.com/control-systems/system- 800xa/800xa-dcs/hardware-controllers-io/ s900-i-o 07 08 09 10 11 12

ABB abb.com/800xa abb.com/freelance abb.com/controlsystems 800xA is a registered or pending trademark of ABB. All rights to other trademarks reside with their respective owners We reserve the right to make technical changes to the products or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not assume any responsibility for any errors or incomplete information in this document. We reserve all rights to this document and the items and images it contains. The reproduction, disclosure to third parties or the use of the content of this document including parts thereof are prohibited without ABB s prior written permission. Copyright 2018 ABB All rights reserved 3BDD013133 en G