OSM PRODUCT GUIDE. OSM AUTOMATIC CIRCUIT RECLOSER 15kV, 27kV & 38kV Models

Similar documents
OSM PRODUCT GUIDE. OSM AUTOMATIC CIRCUIT RECLOSER 15kV, 27kV & 38kV Models

GMK GROUND MOUNT KIOSK PRODUCT GUIDE

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

OSM PRODUCT GUIDE OSM AUTOMATIC CIRCUIT RECLOSER SINGLE TRIPLE MODEL

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

NU-LEC. Loop Automation. Reclosers & Sectionalizers

Elastimold Molded Vacuum Recloser - MVR

OSM. The World s Safest Recloser AUTOMATIC CIRCUIT RECLOSER. PRODUCT GUIDE 15kV/27kV/38kV MODELS

Rapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS

S&C 6801M Automatic Switch Operator

Products Portfolio. Pole mounted Vacuum Recloser

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

Medium Voltage Distribution. U-Series Three-Phase Recloser/ W-Series Single-Phase Recloser with ADVC Controller

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

Vacuum-Break Switches

Siemens Fusesaver and Remote Control Unit 3AD8

Diamondback. Solid Dielectric Load Break Switch Catalog. Distributed By;

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch

POLE MOUNTED Load Break Switch

S Sectionalizers Types TVS15 and TVS27 Time Voltage Sectionalizer Installation and Operation Instructions. Contents

Siemens Vacuum Recloser 3AD. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches

2.1 The NOVA-TS Triple-Single Recloser and Form 6-TS control shall be designed in accordance with the following standards as applicable:

RT4F-110V/25A RECTIFIER

SACE Emax 2 Specification guide

VIP 40/45 VIP 400/410

Functional specification for Form 6 pole-mount recloser control

Form 6 Pole Mount Microprocessor-Based Recloser Control Technical Specifications

Reclosers. Functional Specification Guide PS280026EN. Form 6 Rack/Yard-Mount Recloser Control

SF6 GAS INSULATED PAD MOUNTED. Load Break Switch. SSPGS SERIES 15kV, 25.8kV 400A, 600A

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

RT12-240V/2.4kW Rectifier Specification

COOPER POWER. Types GN3E and GN3VE electronically controlled, manually closed sectionalizers SERIES. Sectionalizers Catalog Data CA270001EN

g Energy Multilin Recloser Controller DGCR Communications Protection Automation & Control Security & EnerVista Software Hardware Metering & Monitoring

Solid Dielectric Switchgear Catalog S-trid13

REC SERIES AUTOMATIC CIRCUIT RECLOSER REC15_AL / REC25_AL. ISO 9001:2008 certification ISO 14001:2004 certification

Ground Breaking MV Switchgear

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

MEDIUM VOLTAGE RING MAIN UNIT

Versa-Tech II Recloser

RT4F-120V/20A-WAC RECTIFIER

RT4F-48V/50A-WAC RECTIFIER

SERIES SD3800 / SD3810 SPECIFICATION

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

WiAutoLink Frequently Asked Questions

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

GRE130. Protection and Control for MV Systems

RT4B-110V/12A RECTIFIER

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

Protection relays.

DIAC/DIFC/DSFC. Single Phase Digital O/C. Single phase or ground overcurrent protection for industrial and utility power systems.

Autodaptive Capacitor Control M 2501B

Magnetic and Hydraulic-Magnetic Circuit Breaker

Protection Relays PHASE & RESIDUAL OVERCURRENT

Performance. Reliability. Simplicity. A smarter grid requires an intelligent recloser.

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

SLI 15 INVERTER SERIES, 1500 W

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

MiCOM P521. Fast Feeder Differential Protection

Testing Instruments Manufactured by

Surge Current Generators PG **-****

WIRELESS SERIES Single or Dual Axis MEMS Inclinometer

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Specification Voltage Limiting Device

SM100. On-Line Switchgear Condition Monitoring

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Magnetically Actuated Safety Interlock Switches

Feeder protection relay SPAA 121 C. Product Guide

Power Distribution Protection & Automation Equipment

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

GRD110 FEATURES APPLICATION

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

DIGITAL TEMPERATURE MONITOR MASTERTEMP ANSI I CATALOG

Solid Dielectric Switchgear

SECTION SWITCHBOARDS

Bus Bar Protection Relay B-PRO 4000

Feeder/ Motor Protection Relay VAMP 40

GRD130 - FEATURES APPLICATION

Medium Voltage Metal-Enclosed Power Capacitor Banks

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

MiCOM P521. Fast feeder differential protection

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

Grid Automation packaged solutions Optimal automation of medium voltage grids

Medium Voltage Distribution Catalogue N-Series. Three phase recloser with ADVC controller

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

g Energy Multilin Voltage Regulator Controller DGCV KEy BENEFITS APPLICATIONS FEATURES Metering & Monitoring Voltage Regulation Communications

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Specifications. S&C Loadbuster Disconnect Switches Outdoor Distribution (14.4 kv through 34.5 kv)

Transcription:

OSM PRODUCT GUIDE OSM AUTOMATIC CIRCUIT RECLOSER 15kV, 27kV & 38kV Models

1. Product Guide OSM Automatic Circuit Recloser 15kV 27kV 38kV Models Introduction INTRODUCTION The OSM15, OSM27 and OSM38 automatic circuit reclosers are designed for use on overhead distribution lines as well as distribution substation applications for all voltage classes up to 15kV, 27kV and 38kV respectively. The OSM tanks are manufactured from stainless steel and powder coated a light grey colour. The product is supplied complete with an RC control and communications cubicle. The RC control cubicle is a microprocessor based controller that provides all the protection, data logging and communications functions in a single device. The OSM has been designed for use as a stand alone device that is easily integrated into distribution automation and remote control schemes using the in-built communications capability. The product has been extensively type tested by independent laboratories to ensure long life and reliability under the harshest environmental conditions. The OSM automatic circuit recloser is the only solid di-electric insulated recloser to provide controlled arc fault venting and the independent testing provides verification of this important safety feature. The product uses technology developed and refined over the last decade. The in-built user configurable distribution automation OSM recloser and RC Control and Communications Cubicle functionality can be used with or without a communications system and will reduce outage time and increase profitability in your network. OSM15 Autorecloser OSM27 Autorecloser OSM38 Autorecloser

Introduction Product Guide OSM Automatic Circuit Recloser 15kV 27kV 38kV Models 2. 1. OVERVIEW The OSM15, OSM27 and OSM38 automatic circuit reclosers incorporate vacuum interrupters inside a polycarbonate and an aromatic epoxy resin housing within an arc vented stainless steel tank respectively. This ensures the maximum in life and reliability with a fully insulated arrangement inside the long life housing. Voltage is measured on all six (6) bushings using capacitively coupled screens. Current is measured on all three (3) phases using current transformers. The recloser mechanism is operated by three (3) separate magnetic actuators, one per phase. These magnetic actuators are mechanically interlocked to guarantee correct three (3) phase operation. The device is latched in the closed position by magnetic latching. Each magnetic actuator uses a single coil. The recloser can be mechanically tripped using the yellow mechanical hook stick operated lever in the base of the tank. The device Open/Close indication, also located in the base of the tank, uses a green 0 to designate contacts are open and a red I to designate contacts closed. The status of the recloser is also reflected by a microswitch connected to the control electronics. The electronic circuit board where the microswitch is fitted has no active elements which dramatically improves impulse immunity. The main circuit bushings are manufactured from UV stable polymer encapsulated in silicone rubber and have a silicone rubber bushing boot providing the required creepage distance. The magnetic actuators are operated from stored energy charged capacitors located in the RC10 control cubicle. There is a rating plate located in the base of the tank that provides tank rating details in accordance with the requirements of ANSI C37.60. There is an earthing point on the side of the tank. The OSM is supplied with tin plated brass cable connectors on each bushing. The cable connectors can be supplied in the form of tunnel terminals to suit cable up to 260mm 2 or 2 hole NEMA cable palms. The cross sectional diagram below details the OSM tank configuration and main components. 1. Bushing Connector 2. Silicone Rubber Bushing Boot 3. Polymer Bushing 4. Current Transformers 5. Capacitively Coupled Voltage Sensor 6. Stainless Steel Tank 7. Magnetic Actuator 8. Opening Spring 9. Auxiliary Switches 10. Insulated Drive Rod 11. Polycarbonate Housing 12. Vacuum Interrupter 13. Ceramic Breather 14. Mechanical trip Ring 15. Vacuum interrupter 16. Push rod - insulating 17. Actuator 18. Epoxy housing 19. Silicone bushing extension 20. Terminal 21. Tank 22. Auxiliary switches OSM15 OSM27 Cross Sectional Diagram OSM38 Cross Sectional Diagram

3. Product Guide OSM Automatic Circuit Recloser 15kV 27kV 38kV Models Introduction RC10 CONTROL & COMMUNICATIONS CUBICLE The RC10 control and communications cubicle is a microprocessor based controller that provides a directional overcurrent, earth fault and sensitive earth fault relay, auto reclosing relay, instantaneous metering, event log, demand logger and remote terminal unit (RTU) for remote control in a single package. The operator control panel is provided with a large backlit LCD display and keypad to provide local control functions. The control cubicle has three (3) main modules: The operator panel module which provides the man machine interface. The Switchgear Interface Module (SIM) which provides the power supply battery charger and incorporates the capacitors that provide the tripping and closing energy to the OSM tank. The Relay module which provides the main microprocessor and DSP functionality. Temperature compensated float charging is provided to the sealed lead acid batteries located in the RC10 control cubicle. There is space provided inside the control cubicle to install any communications equipment to be connected to the inbuilt RTU or I/O module. The equipment has been designed for the RC10 control cubicle to operate over a temperature range of -40 to +55 C inside the IP65 sealed enclosure. The cubicle is constructed out of powder coated stainless steel for a long, maintenance free lifetime. RC10 Control & Communications Cubicle IP65/NEMA 4 Vandal proof cable housing The roof features a ceramic based insulating coating that provides a 16 C reduction in internal temperature when the cubicle is exposed to 1.1kW of solar radiation. The entry point for the control cable is housed within a vandal-proof enclosure and the cubicle door has a three point handle locking mechanism making it extremely difficult to break into.

Introduction Product Guide OSM Automatic Circuit Recloser 15kV 27kV 38kV Models 4. PROTECTION 4 Independent Protection Groups Directional over current and earth fault protection Current Setting Range 10-1280A Setting Resolution 1A Inverse Time Protection Independent Curve Selection for Forward & Reverse Direction 4 x IEC255 Curves 8 x ANSI Curves User Defined Curves 42 x Custom Curves Definite Time Protection 0-120 seconds Time Resolution 0.01 seconds High set Instantaneous element Directional Sensitive Earth Fault Protection Current Setting Range 4-80A 1-80A option available Setting Resolution 1A Definite Time 0-120 seconds Time Resolution 0.01 seconds Voltage Protection Element Phase undervoltage balanced element (UV1) 3 phase load shedding Multiplier setting range: 0.6-1 of system voltage Multiplier setting resolution: 0.01 Trip time range: 0-180 sec Trip time setting resolution: 0.01 sec Phase-to-Phase Undervoltage Element (UV2) Multiplier setting range: 0.6-1 of system voltage Multiplier setting resolution: 0.01 Trip time range: 0-180 sec Trip time setting resolution: 0.01 sec Loss of Supply (UV3) Trip time range: 0-180 sec Trip time setting resolution: 0.01 sec Reclose time: 0-180 sec Reclose time resolution: 0.01 sec Phase (OV1) & Line-to-Line (OV2) Over Voltage Trip time range: 0-180 sec Multiplier Setting Range: 1.00-1.20 Frequency Protection Element Under Frequency (UF) Pickup Range: 46-50Hz (50Hz system), 55-60Hz (60Hz system) Over Frequency (OF) Pickup Range: 50-55Hz (50Hz system), 60-65Hz (60Hz system) Frequency settings resolution: 0.01Hz Trip time range: 0-120 sec Trip time setting resolution: 0.01 sec Voltage reclose control with automatic back feed restoration provides loop automation functionality. Local Control Panel Zone Sequence Co-ordination Cold Load Pickup Cold load time ramp up: 1-400 min Cold load time ramp down: 0-60 min Cold load time resolution: 1 min Cold load multiplier: 1-5 times pickup current Cold load multiplier resolution: 0.1 Inrush Restraint Inrush time: 0.01-10 sec Inrush time resolution: 0.01 sec Inrush multiplier: 1-20 Inrush multiplier resolution: 0.1 Temporary Time Addition Provides a stepped time delay to automatically isolate faulted sections in a feeder or correct grading of devices in series. Duty Cycle O-0.1sec-CO-1sec-CO-1sec-CO-60sec recovery time Reclosing Times 1st reclosing time range 0.1-180 seconds 2nd reclosing time range 1-180 seconds 3rd reclosing time range 1-180 seconds Setting resolution 0.01 seconds Auto Reclose User configurable 1-4 trips to lockout, independently settable for overcurrent earth fault, sensitive earth fault and voltage protection. Live Line Function & Hot Line Tag Function

5. Product Guide OSM Automatic Circuit Recloser 15kV 27kV 38kV Models Introduction MEASUREMENT Voltage is measured on all six (6) bushings and current is measured on all three (3) phases of the OSM recloser using capacitively coupled voltage sensors and current transformers. Phase to Earth Voltage: Range 0.3-22.0kV, Accuracy ± 1% or ± 0.1kV Phase to Phase Voltage: Range 0.5-38.0kV, Accuracy ± 2% or ± 0.1kV Phase Current: Range 0 -, Accuracy ± 1% or ± 4A Residual Current: Range 0-100A, Accuracy ± 5% or ± 0.5A Active, Reactive and Total Power: Range 40 -, 4.5-38kV, Accuracy ± 2% Single and Three Phase Active, Reactive and Total Power: Range 0 - kw/kvar/kva, Accuracy ± 2% Frequency: Range 46-55Hz, 55-65Hz Accuracy at df/dt < 0.2Hz/s: ± 0.025Hz Range 46-55Hz, 55-65Hz Accuracy at df/dt < 0.5Hz/s: ± 0.05Hz Power Factor: Range 0-1, Accuracy ± 0.02 EVENT LOG The RC10 control provides two method to access the event logs time and date stamped to a 0.01 sec resolution. The following parameters are logged separately for both positive and negative power flow. Up to 10000 events can be stored in the memory which corresponds to a 417 day, 60 minute, integration period. CMS can be used to upload and plot the data. REMOTE CONTROL A USB front panel interface is provided to connect to a PC running CMS. This provides full settings and data management facilities. An RS232 RTU interface offering 300-19.2k & 3xUSB port baud, full and half duplex modes, is provided to connect to remote control systems. DNP3 communications protocol is provided in the standard product combined with our ability to engineer new protocols to meet specified customer requests. The control cubicle has space to mount a radio or modem. The onboard radio power supply is rated at 12V 20W continuous duty, 30 watts 50% duty cycle. I/O modules with eight (8) user configurable inputs and eight (8) user configurable outputs can be ordered as options in the RC10 control. Up to two I/O modules can be fitted extending this to sixteen inputs and sixteen outputs. Three (3) user configurable sanitated inputs are included as standard. The first is method is from the RC LCD display, it provides critical operations data for the linesman and includes close/open operations, fault types, phase and peak level of fault current. The second is method is by PC upload using CMS. It provides a full log of all operational history including setting changes, operations and fault history. The fault history logs include 50 cycles of pre-trip history to allow analysis of the fault propagation. LOAD PROFILE LOG The Load Profile is logged with a user configured integration period of either 1, 5, 10, 15, 30, 60 and 120 minutes.

Introduction Product Guide OSM Automatic Circuit Recloser 15kV 27kV 38kV Models 6. OSM38 Terminal Connectors OSM15 and OSM27 Pole Mounting Arrangement OSM15 and OSM27 Terminal Connectors OSM38 Pole Mounting Arrangement Earthing should be in accordance with the technical manual. Earthing required is a main earth bond from the tank to ground and a tee-off to the RC10 control cubicle from this main earth bond. Minimum 35mm 2 earth cable should be used. Each HV terminal on the OSM has a tinplated brass connector at the end with options for cable connection as follows: A Tunnel terminal arrangement suitable for cable sizes from 40mm 2 to 260mm 2. Cables are secured in the connector with two hexagon socket screws. Two hole cable palms with NEMA spacing. The cable palms are supplied with two (2) M12x25mm stainless steel bolts together with flat and spring washers. Tunnel Connector OSM15 and OSM27 Two Hole NEMA Pad Option Pole mounting brackets and surge arrester mounting brackets are provided standard. Full installation details are provided in the technical manual, this diagram is provided to show a typical arrangement only. OSM38

Part Number Current Sensing Voltage Sensing Control Type Rated Maximum Voltage Rated Continuous Current Fault Make Capacity RMS Fault Make Capacity Peak Fault Break Capacity Mechanical Operations Full Load Operations Fault Break Capacity Operations Short Time Current Withstand Mainly Active Breaking Capacity Cable Charging Current Line Charging Current Impulse Withstand Phase to Earth & Phase to Phase Impulse Across the Interrupter Power Frequency Withstand Phase to Earth (Dry) Across the Interrupter Ambient Temperature Humidity Altitude Weight of the Tank OSM15-16-630 3 x Current Transformers 6 x Voltage Screens RC10 15.5kV 16kA 40kA 16kA 200 16kA/4 secs 25A 10A 110kV 110kV 50kV 50kV -40 C to +55 C 0-100% 3000M 85kg OSM27-12-630 3 x Current Transformers 6 x Voltage Screens RC10 27kV 12.5kA 31.5kA 12.5kA 200 12.5kA/4 secs 25A 5A 125kV (150kV option) 125kV (150kV option) 60kV 60kV -40 C to +55 C 0-100% 3000M 85kg OSM38-12-630 3 x Current Transformers 6 x Voltage Screens RC10 38kV 12.5kA 31.5kA 12.5kA 200 12.5kA/3 secs 40A 5A 195kV 170kV 70kV 70kV -40 C to +55 C 0-100% 3000M 140kg Altitudes above 1000m should be derated in accordance with ANSI C37.60-2003 NOJA Power AustrAlia NOJA Power Switchgear Pty Ltd 16 Archimedes Place, Murarrie Brisbane Qld 4172, Australia Phone: +61 7 3907 8777 Fax: +61 7 3399 6777 Email: sales@nojapower.com.au Web: www.nojapower.com.au NOJA Power BRAZIL NOJA Power do Brasil Ltda Rua Alcântara, 825A São Paulo SP CEP 02110-011, Brasil Phone: +55 (11) 2615 4788 Email: vendas@nojapower.com.br Web: www.nojapower.com.br NOJA Power UK NOJA Power Limited 4 Stalyhill Drive, Mottram Rise Stalybridge, Cheshire SK 15 2TR Phone: +44 (01865) 58 9499 Fax: +44 (01865) 58 9400 Email: sales@nojapower.co.uk Web: www.nojapower.co.uk Scan to view NOJA Power website NOJA Power is a registered trademarks of NOJA Power Switchgear Pty Ltd. This document is copyright and is intended for users and distributors of NOJA Power Switchgear product. It contains information that is the intellectual property of NOJA Power Switchgear and the document, or any part thereof, should not be copied or reproduced in any form without written permission from NOJA Power Switchgear. NOJA Power Switchgear applies a policy of continued fundamental research and development and reserves the right to change designs and specifications of this product without notice. NOJA Power Switchgear does not accept any responsibility for loss or damage incurred by anyone as a result of acting or refraining from action based on information in this Product Guide. NOJA-560-01