R507 I.S. Interface Module User Manual

Similar documents
W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

Introduction. General Ratings

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

LVX Control Unit. Features:

Installation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting

TRP-C06H User s Manual

Manual Fiber Optic Interfaces

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Measurement Systems Datascan Installation and User Guide

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

TRP-C07 User s Manual

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

CMU 100 RS485 to Ethernet Converter User Manual CMU 100 / CMU 100 / 1.M.9 CMU 100 / 1.L.9 CMU 100 / CMU 100 / 7.M.9 CMU 100 / 7.L.

Product Data Sheet. BMS/Graphics Interface. Features

Serial PROFIBUS Interface

5 Fieldbus Technology

Manual Industry Interfaces

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

ICF-1150 Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

L5353 Profibus-DP Communications Interface

Trendmaster* Galvanic Isolator

Interface and Supply module. IPC 3x0i / PSC 3x0i

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Serial Data DIN Fiber Link System

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

PCI Express 4-Port Industrial Serial I/O Cards

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

icex-cmtm General specs and Installation guide

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

How to calculate an Intrinsically Safe loop approval.

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

DL-FHD2 Quick Install Guide

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

CONVERTER OF RS-232/RS-485 INTERFACES PD51 TYPE USER S MANUAL

TCNM-ACBB1 Installation Manual

M-series Intrinsically Safe I/O

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

DTM Distributed Transmitter Monitor

Moxa TCC-100 Series User s Guide

Moxa TCC-100 Series Hardware Installation Guide

PHOENIX CONTACT - 10/2009

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

ADA User manual ADA RS-232 to Multidrop Fiber Optic Converter. 1 io_ada-7210_en_v3.17. Copyright CEL-MAR sp.j.

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

F1000 User's Manual. (Version: V1.01)

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

PCAN-Repeater 2-Channel CAN Repeater with galvanic isolation. User Manual V1.0.0

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

Analog display for resistance current

OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

RS-485 module. Data sheet. for electricity meters

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Unique Micro Design First Choice of Professional Systems Intergrators. Model 361 Terminal Keyboard Wedge User Manual

TRP-C08 User s Manual

C-Bus Network Bridge 5500NB. Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

TN-5308 Quick Installation Guide

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

MED102A. Industrial Serial to Single-mode Fiber Converter

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Sentry I.S. Card Reader User Manual

Faults on the system Proximity switch connection technology:

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

General Specifications

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

IMC-21 Quick Installation Guide

FL MC 2000E (SM40) LC

USER MANUAL FOR FIOA-0402-U-16

Product description Rev. 3 11/06/14

User Manual. cmt-svr Startup Guide

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

The AMG5715A1B9 is designed to be powered using an AMG2001 standalone power supply.

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Transcription:

R507 I.S. Interface Module R507 I.S. Interface Module User Manual

Contact Mercury HMI Ltd George House Derwent Road Malton North Yorkshire YO17 6YB Page 2 of 14 Tel: +44 (0) 1653 697200 Fax: +44 (0) 8700 667325 Email: sales@mercuryhmi.co.uk Web: www.mercuryhmi.co.uk Skype: mercuryhmi

Contents Contact... 2 Introduction... 4 Mounting... 5 Connections... 6 Cabling... 7 I.S. Wiring... 8 Safe Area Wiring... 9 RS 485 Wiring...10 RS 232 Wiring...11 Multidrop Wiring...12 ATEX Certificate...13 Specification...16 R507 Pin Description... 17 Page 3 of 14

Introduction Background The R507 is an interface module providing power and data to Intrinsically Safe (I.S.) equipment located in a zone 0 hazardous area, and providing galvanic isolation between the safe area and the I.S. hazard area connection. In the safe area, the communication ports provide both RS 232 for point to point communications or RS 422/485 with tri state control for point to point or multi drop systems. Power and data are transmitted over distances up to 1 km in the hazardous area. The R507 interface module is a critical safety component and should be installed by a competent person in accordance with EN 60079 14 Size The R507 I.S.Interface Module gives almost twice the packing density of its predecessor, the R007. The overall size, including the demountable connectors, but excluding the wiring, is 118mm by 122mm by 23.2mm, maximum. Page 4 of 14

Introduction Mounting Rail Type The R507 I.S. Interface Module is designed to be mounted on standard 35mm symmetrical top hat rail to EN50022 (formerly DIN Standard 46277). The R507 is rated to IP54 and is intended to be mounted in a control panel, a cubicle or rail mounted enclosure. Mounting To mount the R507, tilt the module as shown, engage the lower portion on to the top hat rail and while applying light pressure, lower the R507 until it is horizontal. Release the lateral pressure and the R507 should now be secured to the rail. Repeat this process for all subsequent R507 modules. Removing To remove the R507 from the top hat rail, apply gentle lateral pressure in the direction indicated by arrow No.1, and tilt the far end upward. The unit will then come away from the rail. Page 5 of 14

Connections Segregation The R507 I.S. Interface Module is designed so that all the safe area connections are on one side, the left hand side in the illustration below, and the Intrinsically Safe wiring to the hazardous area is connected on the right hand side of the module. This makes the layout and cable segregation simple. The safe area wiring is made to terminals 1 to 8 and the hazardous area wiring is made to terminals 13 to 16. Terminals 9 to 12 are not used and are not connected within the R507 module. WARNING Page 6 of 14 Care must be taken to ensure that the plug (orange plug supplied with later modules) carrying the 24V power, intended for the upper terminals on the safe area (5 to 8) is not plugged into the lower safe area terminals 1 to 4, which are used for the RS 422 communication. The R507 can be damaged if 24V power is applied to the RS 422 communications ports.

Cabling Intrinsically Safe Connections The R507 I.S. Interface Module provides a voltage and current limited power source for the equipment mounted in potentially hazardous areas while also providing bi directional communications and multi drop control using a quad core or two twisted pairs of a cable. The R507 is designed to drive Mercury 2, Mercury 2e or Mercury 2+ Operator Terminals as well as the Sentry Card Reader WARNING Power must be disconnected before connecting or inspecting the IS interface module. No Intrinsically Safe earth is required as the unit is galvanically isolated. Cable Safety Description The inter connection cable between the safe area IS Interface Module and the hazard area equipment requires four cores, which may be either two twisted pairs or a quad. Where a quad is used, diagonally opposite cores should be paired to reduce any communications cross talk. Each pair is restricted to the following maximum parameters: Loop Resistance Capacitance L/R Ratio 40 Ohms 125 nf max 30 micro H / Ohm For example, a 1 Square millimeter quad cable has approximately the following parameters. Resistance Capacitance L/R Ratio Inductance 38 Ohms/ km (loop) 55 nf / km 12.5 micro H / Ohm 0.48 milli H / km For a cable length of 1km, this would satisfy safety and operating requirements. Page 7 of 14

I.S. Wiring The 4 core Intrinsically Safe wiring can be extended from the safe area, where the barrier is mounted up to 1km into the hazardous area to any of the Mercury 2 family of Operator Terminals or the Sentry Card Reader. The wiring schedules are shown below: Mercury Wiring Sentry Wiring Barrier Pin No & Name Mercury Name & No R507 Pin 13 Rx2 RX2 J5 Pin 4 R507 Pin 14 Rx1 RX1 J5 Pin 3 R507 Pin 15 Tx2+ <==== TX2+ J5 Pin 2 R507 Pin 16 Tx1+ <==== TX1+ J5 Pin 1 Barrier Pin No & Name Sentry Name & No R507 Pin 13 Rx2 A J5 Pin 4 R507 Pin 14 Rx1 B J5 Pin 3 R507 Pin 15 Tx2+ <==== B+ J5 Pin 2 R507 Pin 16 Tx1+ <==== A+ J5 Pin 1 Mercury IMC Limited recommend that no power is supplied to the R507 I.S. Interface Module while hazardous area wiring is being terminated at either the R507 or the Mercury / Sentry in the field. WARNING Page 8 of 14 The R507 I.S. Interface Module is a critical safety component and should be installed by a competent person in accordance with EN 60079 14

Safe Area Wiring The R507 I.S. Interface Module requires a nominal 24V supply of two watts. The voltage can be in the range of 20 to 32 Volts, but it should be a smoothed and regulated supply with low ripple Power Power Name R507 Name & No. 24V Supply +24V In 5 0V Return 0V 6 Comms The R507 is designed to work with several physical serial communications standards. These are RS 232 for simple point to point communications, point to point RS 422, multidrop RS 422 (also known as four wire RS 485) and two wire RS 485. RS 422 Or 4 wire RS 485 Host Signal Name R507 Name & No. RS 422 Host Tx+ Rx+ 1 RS 422 Host Tx Rx 2 RS 422 Host Rx+ <==== Tx+ 3 RS 422 Host Rx <==== Tx 4 Page 9 of 14

RS 485 Wiring It must be remembered that since two wire RS 485 is a half duplex transmission medium, you cannot use point to point mode in conjuction with RS 485, since the transmit to and reception from the Mercury 2 family or Sentry are completely asynchronous events. As RS 485 can only transmit information in one direction at a time, unlike RS 232, RS 422 and four wire RS 485 (also known as multidrop RS 422) which are full duplex transmision media, it requires that a protocol to control the flow of information and to enable the transmitters and receivers to be disabled and enabled as required. RS 485 is more of a communications bus than a simple point to point connection. If you are not familiar with two wire RS 485 and the difficulties of debugging RS 485 communications, we recommend the use of a full duplex connection. Host Signal Name Page 10 of 14 R507 Name & No. RS 485 Host TxRx+ <===> Tx+ & Rx+ 1&3 RS 485 Host TxRx <===> Tx & Rx 2&4

RS 232 Wiring RS 232 is a very reliable communications medium over short distances. When utilised up to 25 Metres and 115,200 baud, no problems should be experienced as long as cables are segregated carefully, and care is taken to eliminate noise from the 0V terminal. The PC 9 way (DE 9) pin number is shown in brackets Host Signal Name R507 Name & No. RS 232 TxD (3) RxIn 7 RS 232 RxD (2) <==== TxOut 8 RS 232 Gnd (5) <===> GND 6 Page 11 of 14

Multidrop Wiring When a number of Mercury Terminals or Sentry Card Readers need to be connected to a single port on a host PC, a DCS or other control system, the multi drop facility can be used. Multi drop RS 422 (four wire RS 485) or two wire RS 485 should be selected as the communications protocol. Each piece of hazardous area equipment needs its own R507 module in the safe area, and the R507s should be connected to the same host port. Each Sentry or Mercury Terminal will need to be configured to have a unique address. Page 12 of 14

Specification Part Number R507 I.S. Interface Module Part Number 8185070 Certification EPSILON 06ATEX2107 The R507 must be mounted in a safe area Physical Data Connections Overall Dimensions Height Width Depth Weight Material Colour IS Terminals IS Earth Isolation Communications 20V, 100 Ohm nominal, galvanically isolated. See page 7 35mm transverse rail EN50022 20 35V d.c. 2W maximum. Nominal 80mA at 24V. Not Required. 2 galvanically isolated ports. RS 232, RS 422 and RS 485 Operating Temperature Storage Humidity Protection Location 20 to +60 C. 40 to +70 C. 95% non condensing. IP 54. Safe Area. IS Cabling Mounting Power Environmental Conditions 122mm. 118 mm, including connectors. 23.2 mm. 160 grams, including connectors. Plastic Black. Page 13 of 14

R507 Pin Description Safe Area Differential Comms Power & RS 232 Comms Not Used Hazardous Area Wiring Page 14 of 14 Pin No. Name Description Pin 1 RS 422 Rx Input to the active low differential receiver Pin 2 RS 422 Rx + Input to the active high differential receiver Pin 3 RS 422 Tx Input to the active low differential transmitter Pin 4 RS 422 Tx + Input to the active high differential transmitter Pin 5 + 24V In Positive power input terminal Pin 6 0V The 0 volt power return and RS 232 Common Pin 7 RxIn RS 232 Receiver input Pin 8 TxOut RS 232 Transmitter output Pin 9 Not Used No internal connection Pin 10 Not Used No internal connection Pin 11 Not Used No internal connection Pin 12 Not Used No internal connection Pin 13 Rx2 MIMC IS Power & Comms Pin 14 Rx1 MIMC IS Power & Comms Pin 15 Tx2+ MIMC IS Power & Comms Pin 16 Tx1+ MIMC IS Power & Comms