technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas
|
|
- Joleen Richards
- 5 years ago
- Views:
Transcription
1 technical datasheet technical datasheet MTL0 Displays Loop-powered indicators for hazardous areas Loop powered -0mA Field and panel mounting Environmental protection to IP7 Easy to configure Number of displayed digits configurable Backlight options Zone mounting The MTL, MTL, MTL and MTL digital indicators enable process variables to be displayed locally in hazardous and general purpose plant areas. A typical example would be the re-transmission of mass/flow computations from the safe area, through a suitable MTL IS interface to the indicator in the hazardous area. The displays are loop powered from the -0mA process signal and their low voltage drop allows them to be installed in almost any -wire, 0mA transmitter loop. All units can indicate measured values in a linear or a square root extraction mode; the latter being used, for example, to display flow from differential pressure measurement devices such as orifice plates, Dall tubes, or venturi. The MTL Field mounting unit is housed in a tough aluminium enclosure, suitable for wall or pipe mounting. For corrosive atmospheres use the MTL - the plastic case provides excellent resistance to harmful contaminents. The MTL is the panel mounted version and is IP, IP, IP7 and NEMA rated. MTLx IS indicators are classified as non-energy storing simple apparatus so they can be inserted into any IS loop without recertification. For Zone mounting, without the need for an IS barrier or isolator, the MTL-NA and MTL-NA are available. EPS0 RevH 07 enquiry@mtl-inst.com
2 MTL, MTL & MTL I.S. INDICATORS loop powered backlight 'B' option The MTLx range offers a variety of field and panel mounting IS indicators to display the current flowing in a 0mA loop. The small voltage drop of <V allows the loop powered display to be installed in almost any 0mA loop. The -NA versions permit mounting in Zone without an IS barrier or isolator. Configuration is carried out using the front panel switches (which can be password protected). Range units, upper and lower limits, decimal point positioning and number of digits displayed are all configured via the front panel. SPECIFICATION Unit location Zone 0, IIC, T hazardous area Display ½ digits - mm height (process value) Eleven 8mm digits (process units & current) Voltage requirements under all conditions <V, loop powered Ambient Temperature Operating: C to 70 C Storage: 0 C to 80 C Humidity -99%RH Input range -0mA Over-range 00mA maximum without damage Display Range to (Configurable) Number of digits after decimal point configurable Zero and span Setting: anywhere in range Scale direction Normal or reverse: software selected. Out of range indication "----- RANGE ERROR" displayed between. -.7mA "99999 RANGE ERROR" displayed at current >ma Operating modes Linear or square root extraction is software selectable. Accuracy at 0 C ± 0.0mA Effects of temperature on accuracy Zero: ± 0.00% of span / C Span: ± 0.0% of span / C Ripple rejection <0.0mA error with ma peak to peak ripple at 0Hz Electrical safety The input circuit of the indicator is designed such that it does not influence the intrinsically safe circuit to which it is connected. (In the USA the application is covered by the entity concept.) Input circuit (terminals & ) in type of explosion protection intrinsically safe Ex ia IIC, with the following parameters: Ui=0V, Ii=00mA, Pi=.W, Ci=0nF, Li=0mH only for connection to a certified intrinsically safe circuit not exceeding these values. Backlight (see Ordering Information & final page for details) Separately powered backlight from an IS power source (U o = 8V, I o = 00mA, P o = 0.9W max.) Dimensions See final page ordering information When ordering a MTL, MTL or MTL, use one of the following order codes to uniquely specify your requirement. Order code Type Backlight material Showing backlight Weight (nom.) style MTL Field No Aluminium 8g A MTLB Field Yes Aluminium 8g A MTL-NA Field No Aluminium 8g A MTLB-NA Field Yes Aluminium 8g A MTL Panel No Aluminium g B MTLB Panel Yes Aluminium g B MTL-NA Panel No Aluminium g B MTLB-NA Panel Yes Aluminium g B MTL Field No GRP 00g A MTLB Field Yes GRP 00g A The given data is only intended as a product description and should not be regarded as a legal warranty of properties or guarantee. In the interest of further technical developments, we reserve the right to make design changes. EUROPE (EMEA): (0)8 7 THE AMERICAS: ASIA-PACIFIC: 9888 enquiry@mtl-inst.com csinfo@mtl-inst.com sales.mtlsing@cooperindustries.com EPS0 RevH 07
3 MTL I.S. INDICATOR loop powered backlight 'B' option The MTL is a DIN-standard, panel mounting, IS indicator to display the current flowing in a 0mA loop. The small voltage drop of <V allows the loop powered display to be installed in almost any 0mA loop. Configuration is carried out using the front panel switches (which can be password protected). Range units, upper and lower limits, decimal point positioning and number of digits displayed are all configured via the front panel. SPECIFICATION Unit location Zone 0, IIC, T hazardous area Display ½ digits - mm height (process value) Eleven 8mm digits (process units & current) Voltage requirements under all conditions <V, loop powered Ambient Temperature Operating: C to 70 C Storage: 0 C to 80 C Humidity -99%RH Input range -0mA Over-range 00mA maximum without damage Display Range to (Configurable) Number of digits after decimal point configurable Zero and span Setting: anywhere in range Scale direction Normal or reverse: software selected. Out of range indication "----- RANGE ERROR" displayed between. -.7mA "99999 RANGE ERROR" displayed at current >ma Operating modes Linear or square root extraction is software selectable. Accuracy at 0 C ± 0.0mA Effects of temperature on accuracy Zero: ± 0.00% of span / C Span: ± 0.0% of span / C Ripple rejection <0.0mA error with ma peak to peak ripple at 0Hz Electrical safety The input circuit of the indicator is designed such that it does not influence the intrinsically safe circuit to which it is connected. (In the USA the application is covered by the entity concept.) Input circuit (terminals & ) in type of explosion protection intrinsically safe Ex ia IIC, with the following parameters: Ui=0V, Ii=00mA, Pi=.W, Ci=0nF, Li=0mH only for connection to a certified intrinsically safe circuit not exceeding these values. Backlight (see Ordering Information & final page for details) Separately powered backlight from an IS power source (U o = 8V, I o = 00mA, P o = 0.9W max.) Dimensions See final page ordering information When ordering a MTL use one of the following order codes to uniquely specify your requirement. Order code Type Backlight material Weight (nom.) style MTL Panel No Aluminium 00g C MTLB Panel Yes Aluminium 00g C The given data is only intended as a product description and should not be regarded as a legal warranty of properties or guarantee. In the interest of further technical developments, we reserve the right to make design changes. EUROPE (EMEA): (0)8 7 THE AMERICAS: ASIA-PACIFIC: 9888 enquiry@mtl-inst.com csinfo@mtl-inst.com sales.mtlsing@cooperindustries.com EPS0 RevH 07
4 case dimensions (mm) Style 'A' front view side view rear view bottom view 0 (.7 ) 0 (. ) 0mm (. ) 7 (.9 ) (. ) mm (0.98 ) MTL - Threaded M0.mm (0.89 ) MTL - Drilled Æ 0 (0.79 ) Style 'B' front view side view panel cutout (0. ) 0 (.7 ) 98 (. ) (. ) 0 (. ) (. ) Style 'C' front view side view panel cutout 7 (.8 ) 0 (.8 ) 8 (.8 ) 8 (. ) (.7 ) (0. ) accessories Order code Description Used with WMP Wall mounting plate MTL/ PMA Pipe mounting adaptor MTL/ used with WMP PIP Pipe mounting kit MTL/ GAS0 Spare gaskets - pk of 0 MTL/ GAS Spare gaskets - pk of 0 MTL Recommended IS interfaces for powering display Input circuits (in series with transmitter) MTL, MTL, MTL7787 Output circuits (direct connected or in series with field device) MTLY, MTLY, MTL778P Recommended IS interfaces for powering backlight MTL, MTL, MTL778P EUROPE (EMEA): (0)8 7 THE AMERICAS: ASIA-PACIFIC: 9888 enquiry@mtl-inst.com csinfo@mtl-inst.com sales.mtlsing@cooperindustries.com EPS0 RevH 07
5 IS indicators /7 DISPLAYS IS display certified to ATEX High contrast LCD with backlight Communication from a safe area via a galvanic isolator Operator push-buttons or external switch inputs Two switch outputs IP front panel The /7 Serial Text Displays are intrinsically safe instruments that can display text and simple graphics in a hazardous area. Having a number of push-buttons and two solid-state switched outputs, they provide a low cost operator interface ideal for simple machine and process control applications. In addition to new installations, the legacy protocol enables existing MTL/ display systems to be easily upgraded. Data and power are normally supplied by a - wire serial data link from an MTL0 isolator in the safe area. This isolator, which can power and communicate with up to two /7 serial text displays, has a bi-directional RS or RS safe area port. Alternatively, a wire system may be used to communicate with up to four /7 text displays. The high contrast LCD incorporates a green backlight that is powered by the serial data link. Brightness and contrast are adjustable enabling the display to be read in all lighting conditions from full sunlight to total darkness. Six push-buttons on the front panel of the (four on the MTL7) may be used for operator acknowledgments or controls. If larger industrial switches are required, these may be connected to the text display rear (MTL7 internal) terminals. When the remote switches are activated, the front panel push-buttons are disabled automatically. Two isolated switch outputs, which can control certified hazardous area loads such as sounders, lamps and valves, are included. The /7 text displays are normally controlled and interrogated by a safe area process computer or by a dedicated instrument such as a PLC or weighing system. The text displays may be used singly but up to four instruments can be multidropped on a hazardous area network. At a data rate of 900 bps, the cable between the safe area galvanic isolator and the /7 text display may be up to 00m long. The protocol, which uses ASCII characters, enables text to be written anywhere on the screen in five different font sizes, together with lines, boxes and bargraphs. Simple bitmap graphics may be downloaded to the display and all characters can be reversed or flashed. Information can also be written to a hidden screen which may be displayed when required. Five different operational modes are selectable, allowing the user to choose the appropriate level of communications security for each application. These range from immediate execution of a command with no message acknowledgement, to a bit CRC. The communications speed, number of stop bits and polarity of the parity bit can also be defined. The legacy protocol enables the or MTL7 to replace an MTL or MTL, in order to provide certification to ATEX and a display backlight. No software or galvanic isolator changes are required and the will fit into the existing panel cut-out. If required, simple modifications to the driver software will allow the enhanced features of the /7 to be used. EUROPE (EMEA) Tel: (0)8 7 Fax: (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: enquiry@mtl-inst.com Web site: July 007
6 SPECIFICATIONS Location Zone 0, or DISPLAY Type 0 x pixel liquid crystal. Display Size 8.mm x mm. Backlight Powered from serial link. Characters ASCII character set, font sizes each with computer definable soft characters. Hidden screen May be written to at any time and displayed when required. Switch cable length m max. OUTPUTS Two software controlled switch outputs. Contacts Isolated single pole solid state switch (certified as simple apparatus). R on less than Ω 0.7V R off greater than MΩ I.S. parameters Ui = 8Vdc, Ii = 00mA, Pi = 0.8W DATA Transmission Speed 0., 0.,.,.,.8, 9. or 9.k bps.* Cable length between isolator(s) & /7 00m max at Baud rate of 9.k bps* *Depends upon configuration & type of cable - see instruction manual. Format or stop bits; odd, even or no parity bit; 7 or 8 data bits. Protocol /7 or MTL/. CONTROLS Front panel : push-buttons which can be software interrogated. MTL7: push-buttons which can be software interrogated. Each button function may be displayed on the screen. Buttons may be disabled. External switches Control may be transferred to six external switches; front panel buttons are inhibited. ENVIRONMENTAL Operating temp 0 C to 0 C (certified for use at 0 C) Humidity To 0 C Enclosure Front IP Rear IP0 MECHANICAL Terminals Removable with screw clamp for 0. to.mm cable. Weight 0.7kg MTL7.kg ACCESSORIES Tag number Thermally printed strip on rear of instrument. Programming guide May be downloaded from APPROVALS For the latest certification information visit: Country (Authority) standards & ATEX Directive) standard) MTL7 Country (Authority) standards & ATEX Directive) standard) Standard EN 000: 00 EN 00: 997 EN 08: 999 EN 009: 980 Standard EN 000: 00 EN 00: 997 EN 08: 999 EN 009: 980 Certificate/ file no. ITS0ATEX7 Ex 0E9 -wire system Ex 0E9 -wire system Ex 0E9 -wire system Certificate/ file no. ITS0ATEX7 Ex 0E9 -wire system Ex 0E9 -wire system Ex 0E9 -wire system Approved for Group II Category G USA (FM) 0 entity 07 Class I, Div, Grps A-D Class, Zone 0 non-incendive Class I, Div, Grps A-D Class, Zone Approved for Group II Category G USA (FM) 0 entity 07 Class I,II,III, Div, Grps A-G Class, Zone 0 non-incendive Class I, Div, Grps A-D Class, Zone Class II, Div, Grps E-G Class III, Div EUROPE (EMEA) Tel: (0)8 7 Fax: (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: enquiry@mtl-inst.com Web site: July 007
7 DIMENSIONS MTL7 DIMENSIONS Panel cut-out Recommended panel cut-out DIN / -0.0 x / -0.0 To achieve an IP seal between the instrument and the panel.0 0./-0.0 x. 0./-0.0 Four panel mounting clips must be used Information This instrument can display text in five font sizes P E 7 Information This instrument can display text in five font sizes TERMINAL CONNECTIONS 7 Three. Æ holes for cable entries S7 S S S S S S Two M clearance holes for surface mounting A A A A Rx Tx V sig 0V V External switches Switch outputs TERMINAL CONNECTIONS CONNECTIONS S S S S S S S7 A A A A Hazardous area Safe area V 0V V sig Tx Rx External switches Switch outputs CONNECTIONS Hazardous area Safe area P E S7 S S S S S S S S S S S S S7 MTL0 RS or RS P E MTL0 RS or RS 0 to V dc S S S S S S S7 0 to V dc S7 S S S S S S Optional external switches -wire system for or text displays Optional external switches -wire system for or text displays EUROPE (EMEA) Tel: (0)8 7 Fax: (0)8 8 AMERICAS Tel: Fax: ASIA PACIFIC Tel: Fax: enquiry@mtl-inst.com Web site: July 007
BA414DF Fieldbus indicator Single variable
FIELDBUS DISPLAYS BA4xx Series BA6xx Series Hazardous area Safe area NEW BA414DF indicator Single variable Shown with optional stainless legend plate Power Supply & Segment Coupler Host Intrinsically safe
More informationBA505C 2-wire 4/20mA manual setpoint station Issue 6
BA505C 2-wire 4/20mA manual setpoint station Issue 6 Issue: 6 3 rd December 2010 2 CONTENTS 1. Description 2. Operation 3. Electrical Systems Design 3.1 4/20mA loop 3.2 Optional Backlights 3.2.1 Separately
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationtechnical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur
technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur For Foundation fieldbus networks in hazardous areas Complete enclosure systems for 6 or 12 intrinsically
More informationBA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12
BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12 Issue: 12 25 th September 2008 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate
More information4 â RIA251. Technical Information. Process display Digital loop powered display for ma current loops
Technical Information RIA251 Process display Digital loop powered display for 4...20 ma current loops Application Plant and machine construction Control panels Laboratory fittings Process display, monitoring
More informationDTM Distributed Transmitter Monitor
Distributed Transmitter Monitor 96 Communication Module The 96 functions as an RS232 to RS485 convertor and / or enables (32) modules to be networked together via Modbus. Combined with the -CFG configuration
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationProcess display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.
Technical information TI 063R/09/en Mat. No. 510 00857 Process display RIA 251 Digital loop powered display for 4...20 ma current loops Application areas Plant and machine construction Control panels Laboratory
More informationBA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3
TR Automatyka Sp. z o. o. Tel. (+48 022) 886 10 16 www.trautomatyka.pl ul. Lechicka 14 ; 02-156 Warszawa Fax. (+48 022) 846 50 37 biuro@trautomatyka.pl BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationF11 Fieldbus Power Hub
technical datasheet technical datasheet F11 Fieldbus Power Hub power conditioner with terminators for fieldbus networks built-in fieldbus power conditioning 5 fieldbus device ports 30mA current per device
More informationM-series Intrinsically Safe I/O
DeltaV Distributed Control System Product Data Sheet M-series Intrinsically Safe I/O Features full system modularity Reduces system footprint Decreases installation time and expense Plug-and-play installation
More informationVariable Area Flowmeter DATASHEET
Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength
More informationTechnical Information RIA15
T004K/09/EN/04.4 759844 Products Solutions Services Technical nformation RA5 Loop-powered 4 to 0 ma with optional HART communication Compact with very low voltage drop for universal use to display 4 to
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationOperating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL
Operating Instructions 12/2010 MN04802006Z-EN MICRO PANEL 2 Device description 2.3 Device versions 2.3 Device versions Fig. 1 MICRO PANELs are available in the following versions: Basic device Display
More informationINSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F
PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4
More informationAssembly MAU. MUX 4 Channels 8 Channels Zone 1
Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.
More informationAssembly MAU. MUX 4 Channels 8 Channels Zone 1
Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.
More informationProduct Summary. Display instrumentation for use in hazardous and safe areas. visit our website Loop Powered Indicators.
Product Summary Loop Powered Indicators Display instrumentation for use in hazardous and safe areas Panel Meters Set Point Stations [Generators] Rate Totalisers Counters Tachometers Timers or Clocks Serial
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationIndicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED
Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure
More informationTFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5
EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on
More informationUFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design
UFD 5 Technical Datasheet Display for ALTOSONIC 5 Configurable display for ALTOSONIC 5 Easy installation Durable design KROHNE 04/2015-0.00000.00.00 CONTENTS UFD 5 1 Product features 3 1.1 Local display
More informationIntrinsically Safe Explosion Proof Barriers
Safety Intrinsically Safe Explosion Proof For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos &
More informationTermination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.
Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous
More informationADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.
EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationCombiView DFON Graphical display
Main features with backlight Showing errors and limits by steady or flashing colours Fits Baumer CombiSeries TM (Ø80 mm FlexHousing) Hygienic design Option: Two configurable relay outputs Programmable
More informationINSTRUCTION MANUAL MODEL RTI-EC RESISTANCE TEMPERATURE INDICATOR TABLE OF CONTENTS 1. GENERAL DESCRIPTION PAGE 1
DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com INSTRUCTION MANUAL MODEL RTI-EC RESISTANCE TEMPERATURE INDICATOR TABLE OF CONTENTS
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationTechnical Information RIA16
TI00144R/09/EN/02.13 71217088 Products Solutions Services Technical Information Field indicator Loop-powered field indicator for looping into the 4 to 20 ma current circuit Application Oil & gas Petrochemical
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationDigital Output Module 8-Channel Version for Zone 1 Series 9475/
www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationIndicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator
Hazardous-Area 830 X R Loop-Powered 16 830 X S1 Loop-Powered 16 830 X S2 Loop-Powered 16 15 Loop-Powered Digital 830 X Loop-Powered 830 X R 830 X S1 830 X S2 The 830 X loop-powered digital indicators are
More informationINSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069
D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according
More information2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions
2 Device description 2.1 Function 2 Device description 2.1 Function MICRO PANELs can be used as HMI devices or as integrated HMI/PLC devices. 2.2 Intended use MICRO PANELs are primarily used in machine
More informationSafety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.
Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff
More informationDATASHEET F043 - TEMPERATURE MONITOR
TEMPERATURE MONITOR WITH ONE HIGH / LOW ALARM OUTPUT. DATASHEET F043 TEMPERATURE MONITOR Features Displays actual temperature and alarm values. Two alarm values can be entered: low and high temperature
More informationTermination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.
Termination Board HiCTB08-SCT-C-SC-RA Features Assembly For 8 modules V DC supply Supported signal types: DI/DO/AI/TI/AO Hazardous area: screw terminals, blue Safe area: screw terminals, black Function
More informationBA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3
BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3 Issue: 3 23 rd June 2011 2 CONTENTS 1. Description 1.1 Documentation 2. Operation 2.1 Error messages
More informationSIY. Features. PC-Programmable Signal Isolator/Converter
September 2017 Description Moore Industries Signal Isolator/Converter combines smart digital technology with advanced analog operation to deliver superior reliability, accuracy, and ease of use. The highly
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More informationTechnical Information Promonitor NRF560
TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo
More informationPD765 TRIDENT. Trident Series Process & Temperature Meters.
PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow
More informationInductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position
More informationPHOENIX CONTACT - 12/2007
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel
More informationPI-EX-ME-2NAM/COC-24VDC
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC
More informationOperating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505
Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating
More informationMGate 5105-MB-EIP Quick Installation Guide
MGate 5105-MB-EIP Quick Installation Guide Edition 2.2, March 2019 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationHow to calculate an Intrinsically Safe loop approval.
MIE TALK - October 2016 How to calculate an Intrinsically Safe loop approval. EXPLOSIVE ATMOSPHERES Compile by: Gary Friend BSc PrEng, CEng MIET, Sales DirectorExtech Safety Systems (MTL, Beka Associates,
More informationExCos-P Pressure sensor 20 Pa Pa
ExCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical, explosion-proof pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue output EC type-approved in acc. with ATEX
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More informationR507 I.S. Interface Module User Manual
R507 I.S. Interface Module R507 I.S. Interface Module User Manual Contact Mercury HMI Ltd George House Derwent Road Malton North Yorkshire YO17 6YB Page 2 of 14 Tel: +44 (0) 1653 697200 Fax: +44 (0) 8700
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationMPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS
MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationDINALOG A 144 x 36 A1400 Light-Strip Indicator
DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to
More informationOperating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX
Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without
More informationCP 502. Piezoelectric pressure transducer. IECEx. » From the Vibro-Meter product line» Operating temperature range: 70 to 560 C ( 94 to F)
Piezoelectric pressure transducer FEATURES» From the Vibro-Meter product line» Operating temperature range: 70 to 560 C ( 94 to 1 040 F)» Pressure capability: up to 100 bar (1450 psi)» Pressure sensitivity:
More informationGeneral Specifications
General Specifications Field Wireless Communication Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Communication Module. This product is based on the industrial
More informationLevel gauges Series LS Level indicator, switch and transmitter for liquids
Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm
More informationTechnical Information RIA16
TI00144R/09/EN/04.14 71251374 Products Solutions Services Technical Information RIA16 Field indicator Looppowered field indicator for looping into the 4 to 20 ma current circuit Application Oil & gas Petrochemical
More informationOperating Instructions
Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail
Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL
More informationtechnical datasheet technical datasheet MTL5995 isolated power supply for fieldbus systems
technical datasheet technical datasheet MTL99 isolated power supply for fieldbus systems Straightforward clip-on DIN-rail mounting Low cost per fieldbus segment High packing densities Simplified installation
More informationTermination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.
Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R
More informationSIY. New. Features! Features. PC-Programmable Signal Isolator/Converter
September 2003 New Features! Data Sheet 2.55 Description Moore Industries Signal Isolator/Converter combines smart digital technology with advanced analog operation to deliver superior reliability, accuracy,
More informationDräger Polytron 8200 Stationary gas detector (CatEx)
Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationProduct data sheet accessories control and regulation Accessories AIRWIN
Product data sheet accessories control and regulation BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching,
More informationD1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S
D109S INSTRUCTION MANUAL SIL Relay Output Module with Line and diagnostics DINRail Model D109S D109 SIL Relay Output Module with Line and diagnostics ISM0096 SIL Applications For Safety Related System
More informationOperating Instructions
Operating Instructions t i SPAN NOT USED - - 4...20mA DISPLAY t i SPAN END POINT DISPLAY Ð - 4...20mA p Safety information, Note Ex area Safety information Please read this manual carefully, and also take
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationPI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationMGate 5111 Quick Installation Guide
MGate 5111 Quick Installation Guide Edition 1.0, December 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationTR Series Vibration Transmitter. User Manual. Installation, operation, maintenance
TR Series Vibration Transmitter User Manual Installation, operation, maintenance Table of Content TR4101 Proximity Loop-powered Transmitter for Shaft Vibration... 3 Introduction... 3 Installation... 5
More informationApplication The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.
DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential
More information4 â Active barrier RN221N with optional HART diagnosis. Technical Information
Technical Information Active barrier with optional HART diagnosis Active barrier with power supply for safe separation of 4 to 20 ma current circuits Application Galvanic isolation of 4 to 20 ma current
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi
ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring
More informationHIGH-VOLTAGE DC METER
HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationSDY. PC-Programmable Signal Isolator/Converter with Display
June 2006 Data Sheet 2.45 Description Moore Industries Signal Isolator/Converter with Display combines smart digital technology with a large display to deliver an accurate signal that is easily monitored
More informationOperating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX
Operator Interface for panel mounting 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without additional enclosure
More informationRT2Y Compact temperature switch intrinsic safety
ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications
More informationICF-1150 Series Quick Installation Guide
ICF-1150 Series Quick Installation Guide Fifth Edition, July 2015 2015 Moxa Inc. All rights reserved. P/N: 1802011500014 1802011500014 Overview Introduction ICF-1150 series fiber converters have a multi-interface
More informationTRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output
More informationThe Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
Acquisition Measurement Control The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationMODCELL 2050R Single Loop Controllers
Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile
More informationVibration Transducer Interface
Vibration Transducer Interface Description The Vibration Transducer Interface (VTI) is a galvanic isolation solution provided by GE s Bently Nevada product line. With the use of galvanic isolation, an
More informationExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)
Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC
More informationHigh Voltage DC Meter
High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More information