Non-Contact Safety System CES-AZ

Similar documents
Safety Switches CES-AR/CET-AR

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

INDUSTRY. Ongoing dialog. Communication at Industry 4.0 level

More than safety. Operating instructions Non-contact safety system CES-A-AEA-02B/CES-A-AEA-04B (Unicode)

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Datasheet - SRB 402EM-24V

Non-Contact Safety System CES-AZ

Datasheet - MZM 100 B ST-1P2PW2REM-A

Datasheet - AZM 200SK-T-1P2PW

Operating Instructions

Magnetically Coded Safety Switches CMS

Contact protection relay

ETD-BL-1T-OFF-CC- 10S

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

QUINT-PS/ 1AC/24DC/ 5

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Product Overview Safety Engineering electronic

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Datasheet - CSS 11-30S-D-M-ST

Datasheet - AZM300Z-ST-1P2P-A

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Online data sheet. T40-E0101K T4000 Direct NON-CONTACT SAFETY SWITCHES

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Datasheet - AZM 200 BZ ST-T-AS P

ITEM ESM-BA301

Datasheet AZM 161 Z ST1 AS RA

MSR178DP. Description. Features. Specifications

Datasheet - SRB 301LC/B-24V

QUINT-PS AC/24DC/10

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

E-STOP relays, safety gate monitors

Operating Instructions

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

Datasheet SRB301ST 24V (V.2)

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

PSR UC/ESAM4/3X1/1X2/B

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

More than safety. Operating instructions Non-contact safety system CES-A-ABA-01/CES-A-ABA-01B (Unicode)

PNOZ s1. Safety relays. Operating Manual EN-07

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Original operating instructions Safety relay with relay outputs G1501S / / 2016

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

E-STOP relay, safety gate monitor

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

HR1S-AC Safety Relay Modules

Datasheet - RSS 36-D-R-ST

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

E-STOP relays, safety gate monitors

ø13,4 58,5 31 Resistant to chemicals of the rubber material: International abbreviation EPDM (APTK) ter polymer Resilience at 20 C:

Safety controller unit B1 /

Safe timer relay/contact expansion modules

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

PSR DC/ESP4/2X1/1X2

E-STOP relays, safety gate monitors

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

SITOP in the SIMATIC Design

Online data sheet. i10-e0454 Lock i10 Lock SAFETY LOCKING DEVICES

QUINT-PS/ 1AC/24DC/20/CO

E-STOP relays, safety gate monitors

RM35LM33MW liquid level control relay RM35-L V AC/DC

PNOZ s2. Safety relays. Operating Manual EN-07

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Non-Contact Safety System CMS. Magnetic Coding. More than safety.

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

SITOP 3-phase 24 V DC, 20 to 40 A

E-STOP relays, safety gate monitors

XPSMCMDO Digital output pairs expansion modules with screw term

Online data sheet. i10-m0233 Lock i10 Lock SAFETY LOCKING DEVICES

Two-hand control unit

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

E-STOP relays, safety gate monitors

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

E-STOP relays, safety gate monitors

MINI MCR-SL-PT100-UI-200

Two-hand control unit

PNOZ s9. Safety relays. Operating Manual EN-08

PI-EX-ME-2NAM/COC-24VDC

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

E-STOP relays, safety gate monitors

Safety Switches CES-AR/CET-AR

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Transcription:

Evaluation unit CE-AZ-AE-01B/ CE-AZ-UE-01B 1) 2) 1 read head can be connected 2 safety outputs (relay contacts with 2 internally connected NO contacts per output) tart button and feedback loop can be connected Plug-in connection terminals Category / PL e according to EN IO 189-1 Evaluation unit CE-AZ-AE-01B Dimension drawing 22,5 11 Cat. PLe 1 H11 H12 TT H1 UB 0V J afety Unit TATE OUT 5 6 Y 99 CE-AZ REET For possible combinations see page 2 13 O1 Y1 23 1 Y2 2 evaluation Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught-in by fitting a jumper. Multicode evaluation Every actuator is detected by the evaluation unit. Guard lock monitoring Evaluation units in the series CE-AZ make it possible to use read heads with integrated guard locking for the personal protection during overtravelling machine movements. For suitable read heads, please refer to the combinations table on page 2. Category according to EN IO 189-1 Due to two redundant safety paths (relay contacts) with 2 internal, monitored NO contacts per safety path, suitable for: Category / PL e according to EN IO 1389-1 Each safety path is independently safe. Block diagram 0V UB J TT CE-AZ-AE-01B 10770 uitable for 35 mm DIN rail according to DIN EN 50022-35 H1 O1 Readhead1 H11H12 EUCHNER K2 K1 23 2 13 1 Y1 Y2 LED display TATE tatus LED Diagnostics LED OUT tatus safety output Additional connections TT Input for self-test O1 Monitoring output (semiconductor) Diagnostics output Y1, Y2 Feedback loop tart button connection Important: The plug-in connection terminals are not included and must be ordered separately. Ordering table eries CE-AZ-AE-01B CE-AZ-AE-01B-EX CE-AZ-UE-01B Multicode Connection set for evaluation unit CE-AZ-.E-01B Category and PL according to EN IO 189-1 up to / PL e 1 Number of read heads Type Order no. / item 1) 3) 10 770 CE-AZ-AE-01B 2) 3) 105 12 up to / PL e 1 ATEX 2) CE-AZ-AE-01B-EX up to / PL e 1 Plug-in crew terminals 105 19 1) CE-AZ-UE-01B 10 756 CE-EA-TC-AK0-10756 1) BG approval pending 2) EX II (3) G [Ex nl] IIC (zone 2 gases), the evaluation unit is only allowed to be used outside potentially explosive atmospheres. 3) UL approval pending 26

Technical data evaluation unit CE-AZ-AE-01B Parameter Housing material Value min. typ. max. Plastic PA6.6 Dimensions 11 x 99 x 22.5 mm Weight 0.2 kg Ambient temperature at U B = DC 2 V -20-55 C Atmospheric humidity, not condensing - - 80 % Degree of protection Degree of contamination 2 Installation DIN rail 35 mm according to EN 50022-35 Number of read heads IP20 1 read head per evaluation unit Connection (plug-in screw terminals/coded) 0.1-2.5 mm² Operating voltage U B (regulated, residual ripple < 5 %) 21 2 27 For the approval according to the following applies Operation with UL-class 2 power supply only, or equivalent measures Current consumption I B (with relay energized) 1) - 150 - ma External fuse (operating voltage U B ) 0.25-8 A afety contacts witching current (relay outputs) 2 (relays with internally monitored contacts) - At switching voltage AC/DC 21... 60 V 1-300 - At switching voltage AC/DC 5... 30 V 10-000 - At switching voltage AC 5... 230 V (160 V ATEX) 10-2000 witching load according to Max. AC 30 V, class 2 / max. DC 60 V, class 2 External fuse (safety circuit) according to EN 60269-1 6 A gg or 6 A circuit breaker (characteristic B or C) Utilization category acc. to EN 6097-5-1 AC-12 60V 0.3A / DC-12 60V 0.3A AC-12 30V A / DC-12 30V A AC-15 230V 2A / DC-13 2V 3A - For ATEX version AC-12 60V 0.3A / DC-12 60V 0.3A AC-12 30V A / DC-12 30V A AC-15 160V 2A / DC-13 2V 3A Classification according to EN 6097-5-3 Rated insulation voltage U i 250 V Rated impulse withstand voltage U imp kv Rated conditional short-circuit current 100 A PDF-M Resilience to vibration In acc. with EN 6097-5-2 Mechanical operating cycles (relays) 10 x 10 6 witching delay from state change 2) - - 210 Time difference (between the switching points of the two relays) - - 25 Current via feedback loop Y1/Y2 5 8 10 ma Permissible resistance via feedback loop - - 600 W Ready delay 3) - 10 12 s Dwell time ) 3 - - s witching frequency max. 5) - - 0.25 Hz Repeat accuracy R according to EN IEC 6097-5-3 10 % Monitoring outputs (diagnostics, door monitoring output O1, semiconductor output, p-switching, short-circuit protected) - Output voltage 0.8 x U B - U B - Max. load - - 20 ma tart button input, test input TT - Input voltage LOW 0-2 HIGH 15 - U B - Input current HIGH 5 8 10 ma EMC protection requirements In acc. with EN 6097-5-3 Reliability figures according to EN IO 189-1 as a function of the switching current at 2 0.1 A 1 A A Category Performance level (PL) e PFH d 1.9 x 10-8 Mission time 20 years Number of switching cycles/year 760000 153000 3600 1) Without taking into account the load currents on the monitoring outputs. 2) Corresponds to the risk time according to EN 6097-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 6097-5-3, the switch-off delay can increase to max. 250. After a brief actuation < 0.25 s, the switch-on delay can increase to max. 3 s if this is followed immediately by further actuation. 3) After the operating voltage is switched on, the relay outputs are switched off and the door monitoring contact is set LOW during the ready delay. For the visual indication of the delay, the green TATE LED flashes at a frequency of approx. 15 Hz. ) The dwell time is the time that the actuator must be inside or outside the operating distance. 5) In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed. Unit ma 27

Evaluation unit CE-AZ-AE-02B 1) 2 read heads can be connected 2 safety outputs (relay contacts with 2 internally connected NO contacts per output) tart button and feedback loop can be connected Plug-in connection terminals Category / PL e according to EN IO 189-1 Evaluation unit CE-AZ-AE-02B Dimension drawing 5 11 Cat. PLe 2 13 TT 1 J1 J2 H11 H12 H1 UB H21 H22 H2 0V TATE OUT afety Unit 1 2 5 6 H1 H2 Y REET CE - AZ 99 For possible combinations see page 2 O1 O2 23 Y1 Y2 2 evaluation Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught-in by fitting a jumper. Multicode evaluation Every actuator is detected by the evaluation unit. Guard lock monitoring Evaluation units in the series CE-AZ make it possible to use read heads with integrated guard locking for the personal protection during overtravelling machine movements. For suitable read heads, please refer to the combinations table on page 2. Category according to EN IO 189-1 Due to two redundant safety paths (relay contacts) with 2 internal, monitored NO contacts per safety path, suitable for: Category / PL e according to EN IO 1389-1 Each safety path is independently safe. Block diagram TT CE-AZ-AE-02B 10775 O1 uitable for 35 mm DIN rail according to DIN EN 50022-35 O2 EUCHNER Readhead2 Readhead1 0V UB J1 J2 H1 H11H12 H2 H21H22 K2 K1 23 2 13 1 Y1 Y2 LED display TATE tatus LED Diagnostics LED OUT tatus safety output Additional connections TT Input for self-test O1, O2 Monitoring outputs (semiconductor) Diagnostics output Y1, Y2 Feedback loop tart button connection Important: The plug-in connection terminals are not included and must be ordered separately. Ordering table eries CE-AZ-AE-02B CE-AZ-UE-02B Multicode Connection set for evaluation unit CE-AZ-.E-02B Category and PL according to EN IO 189-1 up to / PL e 2 up to / PL e 2 Number of read heads Type Order no. / item Plug-in crew terminals 10 775 CE-AZ-AE-02B 105 10 CE-AZ-UE-02B 10 771 CE-EA-TC-AK06-10771 1) BG approval pending 28

Technical data evaluation unit CE-AZ-AE-02B Parameter Housing material Value min. typ. max. Plastic PA6.6 Dimensions 11 x 99 x 5 mm Weight 0.25 kg Ambient temperature at U B = DC 2 V -20-55 C Atmospheric humidity, not condensing - - 80 % Degree of protection Degree of contamination 2 Installation DIN rail 35 mm according to EN 50022-35 Number of read heads IP20 Max. 2 read heads per evaluation unit Connection (plug-in screw terminals/coded) 0.1-2.5 mm² Operating voltage U B (regulated, residual ripple < 5 %) 21 2 27 For the approval according to the following applies Operation with UL-class 2 power supply only, or equivalent measures Current consumption I B (with relay energized) 1) - 150 - ma External fuse (operating voltage U B ) 0. - 8 A afety contacts witching current (relay outputs) 2 (relays with internally monitored contacts) - At switching voltage AC/DC 21... 60 V 1-300 - At switching voltage AC/DC 5... 30 V 10-000 - At switching voltage AC 5... 230 V 10-2000 witching load according to Max. AC 30 V, class 2 / max. DC 60 V, class 2 External fuse (safety circuit) according to EN 60269-1 6 A gg or 6 A circuit breaker (characteristic B or C) Utilization category acc. to EN 6097-5-1 AC-12 60V 0.3A / DC-12 60V 0.3A AC-12 30V 6A / DC-12 30V 6A AC-15 230V 2A / DC-13 2V 3A Classification according to EN 6097-5-3 Rated insulation voltage U i 250 V Rated impulse withstand voltage U imp kv Rated conditional short-circuit current 100 A PDF-M Resilience to vibration In acc. with EN 6097-5-2 Mechanical operating cycles (relays) 10 x 10 6 witching delay from state change 2) - 2 activated actuators - - 290-1 activated actuator - - 210 Time difference between the switching points of the two relays (with 2 activated actuators) - - 25 Manual start operating mode - Duration of operation of start button 250 - - - tart button response delay - 200 300 Current via feedback loop Y1/Y2 5 8 10 ma Permissible resistance via feedback loop - - 600 W Ready delay 3) - 10 12 s Dwell time ) 3 - - s witching frequency max. 5) - - 0.25 Hz Repeat accuracy R according to EN IEC 6097-5-3 10 % Monitoring outputs (diagnostics, release 01...02, semiconductor output, p-switching, short circuit-protected) - Output voltage 0.8 x U B - U B - Max. load - - 20 ma tart button input, test input TT - Input voltage LOW 0-2 HIGH 15 - U B - Input current HIGH 5 8 10 ma EMC protection requirements In acc. with EN 6097-5-3 Reliability figures according to EN IO 189-1 as a function of the switching current at 2 0.1 A 1 A A Category Performance level (PL) e PFH d 1.9 x 10-8 Mission time 20 years Number of switching cycles/year 760000 153000 3600 1) Without taking into account the load currents on the monitoring outputs. 2) Corresponds to the risk time according to EN 6097-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 6097-5-3, the switch-off delay can increase to max. 30. After a brief actuation < 0. s, the switch-on delay can increase to max. 3 s if this is followed immediately by further actuation. 3) After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green TATE LED flashes at a frequency of approx. 15 Hz. ) The dwell time is the time that the actuator must be inside or outside the operating distance. 5) In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed. Unit ma 29

Evaluation unit CE-AZ-AE-0B 1) read heads can be connected 2 safety outputs (relay contacts with 2 internally connected NO contacts per output) tart button and feedback loop can be connected Plug-in connection terminals Category / PL e according to EN IO 189-1 Evaluation unit CE-AZ-AE-0B Dimension drawing 5 11 Cat. PLe 13 TT 1 J1 J2 H11 H12 H1 UB H21 H22 H2 0V TATE OUT afety Unit H1 H2 H3 H Y REET CE - AZ 99 O1 O2 O3 O H31 H32 H3 For possible combinations see page 2 23 Y1 Y2 2 H1 H2 H evaluation Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught-in by fitting a jumper. Multicode evaluation Every actuator is detected by the evaluation unit. Guard lock monitoring Evaluation units in the series CE-AZ make it possible to use read heads with integrated guard locking for the personal protection during overtravelling machine movements. For suitable read heads, please refer to the combinations table on page 2. Category according to EN IO 189-1 Due to two redundant safety paths (relay contacts) with 2 internal, monitored NO contacts per safety path, suitable for: Category / PL e according to EN IO 1389-1 Each safety path is independently safe. Block diagram TT CE-AZ-AE-0B 10780 O1 uitable for 35 mm DIN rail according to DIN EN 50022-35 EUCHNER O2 O3 O 0V UB J1 J2 H1 H11H12 H2 H21H22 H3 K2 K1 23 2 H31H32 13 1 H Y1 Readhead Readhead1 Readhead2 Readhead3 H1H2 Y2 LED display TATE tatus LED Diagnostics LED OUT tatus safety output Additional connections TT Input for self-test O1...O Monitoring outputs (semiconductor) Diagnostics output Y1, Y2 Feedback loop tart button connection Important: The plug-in connection terminals are not included and must be ordered separately. Ordering table eries CE-AZ-AE-0B CE-AZ-UE-0B Multicode Connection set for evaluation unit CE-AZ-.E-0B Category and PL according to EN IO 189-1 up to / PL e up to / PL e Number of read heads Type Order no. / item Plug-in crew terminals 10 780 CE-AZ-AE-0B 105 11 CE-AZ-UE-0B 10 776 CE-EA-TC-AK08-10776 1) BG approval pending 0

Technical data evaluation unit CE-AZ-AE-0B Parameter Value min. typ. max. Housing material Plastic PA6.6 Dimensions 11 x 99 x 5 mm Weight 0.25 kg Ambient temperature at U B = DC 2 V -20-55 C Atmospheric humidity, not condensing - - 80 % Degree of protection IP20 Degree of contamination 2 Installation DIN rail 35 mm according to EN 50022-35 Number of read heads Max. read heads per evaluation unit Connection (plug-in screw terminals/coded) 0.1-2.5 mm² Operating voltage U B (regulated, residual ripple < 5 %) 21 2 27 For the approval according to the following applies Operation with UL-class 2 power supply only, or equivalent measures Current consumption I B (with relay energized) 1) - 150 - ma External fuse (operating voltage U B ) 0. - 8 A afety contacts 2 (relays with internally monitored contacts) witching current (relay outputs) - At switching voltage AC/DC 21... 60 V 1-300 - At switching voltage AC/DC 5... 30 V 10-000 - At switching voltage AC 5... 230 V 10-2000 witching load according to Max. AC 30 V, class 2 / max. DC 60 V, class 2 External fuse (safety circuit) according to EN 60269-1 6 A gg or 6 A circuit breaker (characteristic B or C) Utilization category acc. to EN 6097-5-1 AC-12 60V 0.3A / DC-12 60V 0.3A AC-12 30V 6A / DC-12 30V 6A AC-15 230V 2A / DC-13 2V 3A Classification according to EN 6097-5-3 PDF-M Rated insulation voltage U i 250 V Rated impulse withstand voltage U imp kv Rated conditional short-circuit current 100 A Resilience to vibration In acc. with EN 6097-5-2 Mechanical operating cycles (relays) 10 x 10 6 witching delay from state change 2) - activated actuators - - 50-3 activated actuators - - 370-2 activated actuators - - 290-1 activated actuator - - 210 Time difference between the switching points of the two relays (with activated actuators) - - 25 Manual start operating mode - Duration of operation of start button 250 - - - tart button response delay - 200 300 Current via feedback loop Y1/Y2 5 8 10 ma Permissible resistance via feedback loop - - 600 W Ready delay 3) - 10 12 s Dwell time ) 3 - - s witching frequency max. 5) - - 0.25 Hz Repeat accuracy R according to EN IEC 6097-5-3 10 % Monitoring outputs (diagnostics, release 01...02, semiconductor output, p-switching, short circuit-protected) - Output voltage 0.8 x U B - U B - Max. load - - 20 ma tart button input, test input TT - Input voltage LOW 0-2 HIGH 15 - U B - Input current HIGH 5 8 10 ma EMC protection requirements In acc. with EN 6097-5-3 Reliability figures according to EN IO 189-1 as a function of the switching current at 2 0.1 A 1 A A Category Performance level (PL) e PFH d 1.9 x 10-8 Mission time 20 years Number of switching cycles/year 760000 153000 3600 1) Without taking into account the load currents on the monitoring outputs. 2) Corresponds to the risk time according to EN 6097-5-3. This is the maximum switch-off delay for the safety outputs following removal of the actuator. In case of EMC interference in excess of the requirements in accordance with EN 6097-5-3, the switch-off delay can increase to max. 750. After a brief actuation < 0.8 s, the switch-on delay can increase to max. 3 s if this is followed immediately by further actuation. 3) After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set LOW during the ready delay. For the visual indication of the delay, the green TATE LED flashes at a frequency of approx. 15 Hz. ) The dwell time is the time that the actuator must be inside or outside the operating distance. 5) In case of monitoring with feedback loop, the actuators must remain outside the operating distance, e.g. with a door open, until the feedback circuit is closed. Unit ma 1